IB Signal/IB Signal at On - Lesson 21

Sdílet
Vložit
  • čas přidán 15. 03. 2022
  • 1. IB Signal
    2. IB Signal at On
    a. Loco Pilot Prewarned
    b. Loco Pilot not Prewarned
    c. IB phone out of order
    #IndianRailways
  • Věda a technologie

Komentáře • 38

  • @pramodkoligudde6393
    @pramodkoligudde6393 Před 2 měsíci +2

    Thank you sir ji

  • @pramodkoligudde6393
    @pramodkoligudde6393 Před 2 měsíci +2

    Sir ji super

  • @gopalpandey3634
    @gopalpandey3634 Před rokem +3

    Sir ap bahut Accha batate hai you are great more knowledge

  • @vijendrameena5828
    @vijendrameena5828 Před rokem +3

    Very Very Thanking you for without doubted clarification

  • @jaisinghjaisingh6717
    @jaisinghjaisingh6717 Před rokem +2

    बहुत अच्छा समझाया sir बहुत बहुत आभार आपका JAI SINGH/GTL

  • @mangalaprasadojha5328
    @mangalaprasadojha5328 Před 2 lety +4

    Thank you all for your affection and support.
    Please like, subscribe and share (LSS) in your groups & Facebook.

  • @pramodkoligudde6393
    @pramodkoligudde6393 Před 2 měsíci +1

    Sir ji Aap ka notes milega

  • @rammeena3043
    @rammeena3043 Před 9 měsíci +1

    Very useful sirji thanks

  • @shivanididis1400
    @shivanididis1400 Před 7 měsíci +3

    If LP not prewarned then block working is suspended??

    • @mangalaprasadojha5328
      @mangalaprasadojha5328 Před 7 měsíci

      Not pre warned means any written Authority is not given to LP at the Station.
      It means train is going on Signal.
      Then why are you thinking that block working is suspended.

  • @aneelk15
    @aneelk15 Před 2 lety +2

    Tq very much sir

  • @VIKASHKUMAR-no1ut
    @VIKASHKUMAR-no1ut Před rokem +2

    Nice sir, Vikash Kumar from gaya

  • @kamalkumar2904
    @kamalkumar2904 Před rokem +2

    Thank you sir

  • @PARMESHWARLALLAL
    @PARMESHWARLALLAL Před 2 lety +1

    Great work sir thanks 🙏🙏

  • @yadavpintuBihari
    @yadavpintuBihari Před 3 měsíci +1

    IB signal Defective ke bare me bataye sir

    • @mangalaprasadojha5328
      @mangalaprasadojha5328 Před 2 měsíci +1

      इस वीडियो में जो IB Signal at On बोला गया है, at On का मतलब Defective IB Signal hi hota hai
      Dono same hai

  • @patibandlasuresh1018
    @patibandlasuresh1018 Před 2 lety +2

    Thnk u sir

  • @swadhinpaul3084
    @swadhinpaul3084 Před 9 měsíci +2

    Sir, in the case of LP was prewarned that ib signal at on, what purpose do the plct serve? Does the plct give the private number that the rear sm got from next sm as a consent to start a train into axle counter section? Why is not only to take t369(3b) sufficient? You also said that rear sm will make sure that no level crossing gates are open before giving plct. Does that mean gate signals are also suspended like ibs signal? Then should LP ignore the 'ON' aspect of gate and ibs signals upto next station in this case?
    My another issue is that a few days back at a station starter and advanced starter were green, and only t369(3b) (no another form of plct was given) was given for upcoming defective ibs signal with a private number written at the space where in that form it is printed that " ** in case of failure of advanced starter signal / last stop signal..." So my question here is as advanced starter was given green from red, then to write a private number in t369(3b) at the space for failed advance starter makes no sense to me. Please again clarify what is the purpose of private number in t369(3b) and private number in plct serve? And in my case was the sm should have issued a plct a mandatory thing? Was it a wrong procedure to not to issue plct? Should the LP demand plct from the SM in the prewarned case even after the SM says the LSS is not defective as he can put it from red to green to start the train?

    • @mangalaprasadojha5328
      @mangalaprasadojha5328 Před 8 měsíci +1

      As per G&SR rules if any one failed (Axle Counter/Adv Starter/IB Sig/Block Instrument), IB working should be suspended & both the Section should be treated as one Section.
      LP should be given
      PLCT +T/369(3b)
      Speed-normal
      If SM is using Adv Starter when IB Sig is not working, it is short cut method and not permitted in the rules.
      When SM is giving PLCT, he will ensure closing of all LC gates.
      As a LP we have to follow the Gate Signal if any.
      Since IB working is suspended & IB signal at on, therefore any IB connected gate signal will be non interlocked & Gateman has to close, LP has to follow gate rule

  • @sk-rw4xt
    @sk-rw4xt Před 2 měsíci +1

    Who will take off signal of IB rear or advance station master

  • @ajayv3566
    @ajayv3566 Před 10 dny

    Sir plz upload one video about all authorities and speed restrictions

  • @RupeshKumar-nq5dz
    @RupeshKumar-nq5dz Před 5 měsíci +2

    Passing IB signal is on condition speed is 15/10 in G & SR. Is it is wrong sir.

  • @sumitsalve5095
    @sumitsalve5095 Před 8 měsíci +1

    Thank you sir, for this vdo, sir
    What is piloting section, and what is handicapped section

    • @mangalaprasadojha5328
      @mangalaprasadojha5328 Před 7 měsíci

      Piloting means train is being received on written Authority.
      Handicapped section, as I think, means where train movement is having some problems

  • @mangalaprasadojha5328
    @mangalaprasadojha5328 Před 2 lety +1

    In case of any doubt, please write your comments or suggestions here, Thank you for watching and subscribing 😊

  • @startsnownewlife1303
    @startsnownewlife1303 Před rokem +1

    Thanks sir