Section E - Fault diagnosis and rectification - AM2 pre assessment manual

Sdílet
Vložit
  • čas přidán 26. 12. 2020
  • In this video I continue talking you through the AM2 assessment using the NET pre-assessment manual, available off of the NET website.
    I discuss the types of fault, apply them to a ring or a radial circuit, and discuss the reasoning behind the location description, rectification method and the need to test and prove the repair works.
    I also talk you through a simple heating and hot water installation using a flow chart, which will not only help you diagnose where the faults might be, but may also help you get your head around how they are connected.
    I’m not 100% happy with this video, as I think I could have done it better, so I’m going to tweak it slightly later on.
    But for now, this will get you started.

Komentáře • 128

  • @EW00AW04
    @EW00AW04 Před 2 měsíci +2

    If you don’t want to buy the XS training videos for the whole AM2 prep course then this guy is your best best bet

  • @paulkabanda4360
    @paulkabanda4360 Před 9 měsíci +5

    I don't ever comment on CZcams videos but I had to send out a massive thank you to Adrian. I failed my fault finding the first time. I found this channel and it has been so helpful. I passed it on second attempt. No nerves at all going it as your explanation of how to fault find was on point. Thanks again

    • @Pure_electrical_training
      @Pure_electrical_training  Před 9 měsíci +1

      Thank you so much for your positive feedback, and congratulations on passing your AM2 🤗👊

  • @MitchellAlastair
    @MitchellAlastair Před měsícem

    Brilliant video, very helpful! Thank you Adrian!

  • @TheDecagon247
    @TheDecagon247 Před 3 lety +6

    love the whole series of AM2 videos your doing massive help :)

  • @craiglewis3726
    @craiglewis3726 Před 3 lety +6

    Great informative video Adrian. You explain things very well! Thank you so much for taking the time to make these videos. Keep up the good work mate 👍🏻

  • @caffeine9317
    @caffeine9317 Před 2 lety +9

    Passed the Am2s, had to resit fault finding - your videos helped a ton, thanks!

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety +1

      Congratulations 👏

    • @Alexander_sparky
      @Alexander_sparky Před rokem

      I’m
      Rewiring my fault finding soon stressing out 😂😂

    • @caffeine9317
      @caffeine9317 Před rokem

      @@Alexander_sparky you got this, just remember you're allowed to use your book if you're stuck but you should be sweet :-)

  • @jameslong966
    @jameslong966 Před 3 lety +2

    Sitting my Am2 in afew weeks, Great video! 👍

  • @Shukovsky
    @Shukovsky Před 3 lety +2

    This is the most informative video I've seen on electrics, its the night before my inspection and testing/fault finding am2s day, so thanks mate

    • @Pure_electrical_training
      @Pure_electrical_training  Před 3 lety +2

      You are more than welcome, spread the word and hopefully I can help others in the same situation

    • @Shukovsky
      @Shukovsky Před 3 lety

      @@Pure_electrical_training i will mate count on it 👍🏻

  • @aaronsmart7896
    @aaronsmart7896 Před 9 měsíci +1

    Awesome content! AM2S next week, glad I found these videos. Thank you!

  • @morgandevereux2028
    @morgandevereux2028 Před 7 měsíci +1

    Very good video. Thank you very much for taking the time to run through those important points!

  • @drsamuelbeckett2998
    @drsamuelbeckett2998 Před 2 lety +1

    Thankyou for this video Adrian it was an awesome video and helped massively with me passing my AM2.

  • @TheFella172
    @TheFella172 Před rokem +2

    Another fantastic video, this will help with setting yourself up for the AM2 exam and applying the knowledge you should already have. I am currently watching this video series through first, and will then watch the series again from the begininning with paperwork and reference textbooks as advised. My only other comment is the books have now changed since these videos were recorded to the BS7671 2018:2, (brown book/brown flash), so the page numbers are different to what is said in the video.
    Top job Adrian! Thank you. (Brent).

    • @Pure_electrical_training
      @Pure_electrical_training  Před rokem

      Thank you for the great feedback Brent 🤗
      I should have thought about the page numbers bring different in future BS7671 editions 🤦‍♂️

  • @Iceman030591
    @Iceman030591 Před 2 lety +1

    Smashed my fault finding re-sit, your video was a lot of help thanks mate, keep up the good work.

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety

      Thank you and well done 👏

    • @dasbeatz4512
      @dasbeatz4512 Před rokem

      @@Pure_electrical_training Are you allowed to do a insulation resistance test on the fault finding?

  • @zilvinas05
    @zilvinas05 Před 2 lety +6

    Super informative and helpful videos, as my am2 exam is coming very soon. Probably best preparation you can find on youtube! Highly recommended to all learners and for people who are working already, to be sure they doing it in right way. All the best of luck Adrian!

  • @trevorhall9377
    @trevorhall9377 Před 3 lety +1

    Thanks for your video found it so helpful I failed twice watched your video put me at ease helped me stop getting confused under pressure thanks again Easy to remember on the day under pressure many thanks

  • @ryanjholden
    @ryanjholden Před 3 měsíci +1

    Never comment on videos but this is top tier 👍🏻 cheers

  • @addygbwfc
    @addygbwfc Před 3 lety +7

    Great video nice one, passed all AM2 apart from fault finding, just re sitting in a couple week and found this has eased some pressure🤝

  • @HhhGgg-iy1mk
    @HhhGgg-iy1mk Před 3 lety +1

    Very good roundup. Thank you mate, top job

  • @Jonjo999
    @Jonjo999 Před 4 měsíci +1

    Passed everything on my AM2S first time and only failed just my fault finding section by 2 bloody marks, right now is sunday late evening, got my resit tomorrow (monday), just watching your video to recap has helped me alot. Everyone wish me luck! Thanks Adrian!

    • @tayloryoung3130
      @tayloryoung3130 Před 4 měsíci

      How do you know u failed by 2 marks ?

    • @Pure_electrical_training
      @Pure_electrical_training  Před 4 měsíci

      Good luck 🙌

    • @Jonjo999
      @Jonjo999 Před 4 měsíci

      @@tayloryoung3130 got a call from the assessment centre and they told me

    • @Jonjo999
      @Jonjo999 Před 4 měsíci

      @@Pure_electrical_training i passed mate, thank you soo much 🙏🏼

    • @Jonjo999
      @Jonjo999 Před 4 měsíci

      @@tayloryoung3130 i got a call from the centre where i did my exam

  • @mrsid4208
    @mrsid4208 Před rokem +2

    This video helped me so much in my AM2E 🙏🏼 and I have Smashed it 😍.

  • @lokiop345
    @lokiop345 Před 3 lety

    Great vid mate... very hard subject.. very very hard subject.. got my fault finding tomorrow and will almost certainly fail. Difficult subject well explained... but it doesn't change the difficulties!!! Damn it ! 😪

  • @martinogrady6268
    @martinogrady6268 Před 3 lety +8

    I’m actually in the middle of my am2s now. Practical was yesterday. Fault find today and inspection, testing an online exam tomorrow. Thanks for the videos! Great help!

  • @Sergey3023
    @Sergey3023 Před 3 lety +1

    Great video!
    Thank you for sharing 👍🏻

  • @gyasikrasineb4808
    @gyasikrasineb4808 Před rokem +2

    Excellent presentation so much to take in.

  • @macoveivasile75
    @macoveivasile75 Před rokem +1

    Thank you for your videos, help me a lot !!!

  • @krazylad84
    @krazylad84 Před 3 lety +1

    Cheers Adrian, very helpful video.

  • @davidlewis4162
    @davidlewis4162 Před 2 lety +1

    This is a great video, Thanks

  • @sbmorris2k6
    @sbmorris2k6 Před 3 lety +5

    I was told simple things like using the wrong words in some test centres can fail you so, instead of cross connection it has to be cross polarity and things like that. Good video though really helpful got my am2 coming up 👌

  • @ef7480
    @ef7480 Před 2 lety +1

    Brilliant.....

  • @sunshine3187
    @sunshine3187 Před rokem +1

    This is hands down the best video ive seen for the AM2.
    I have mine next week. I have two questions dude.
    1, can you open the accessories on the am2 fault finding section?
    2, can you use the long lead test for polarity on ring final?
    Cheers.

    • @Pure_electrical_training
      @Pure_electrical_training  Před rokem

      Thank you 🤗
      You can open the accessories to disconnect cables, but the cabling will look correct as the faults are introduced behind the scenes, which can throw a lot of people off.
      You could use the long lead method to test conductors through the circuit if you wanted too. The installation is so small that you wouldn’t actually need a long lead, the normal leads are long enough

  • @nickiwell1159
    @nickiwell1159 Před 2 lety +1

    Very helpful

  • @Big-T-
    @Big-T- Před rokem +1

    Got my reset for section E, failed it by 2 marks, gonna smash it today, cheers.

  • @pinaconorth007
    @pinaconorth007 Před rokem +1

    Thank you 😊

  • @bernardcharlesworth9860
    @bernardcharlesworth9860 Před rokem +2

    Nice chap

  • @jamiemaxted2371
    @jamiemaxted2371 Před 2 lety +2

    Your video is so good and im currently revising for my AM2 fault finding that i need to resit at the end of the month. Personally this has been very good for my learning of fault finding especially with the boiler breakdown and also intermediate switching and ring finals, my only thing that i tend to struggle with at the moment is going with what test to start with ( IR or Continuity) would you tend to go straight for the IR test if you was for example getting an MCB tripping? with an MCB tripping it could also be a misconnection as well as a short circuit, im interested to know what route you would take first in regards to what test you would do as i struggle with this if im honest and want to obviously find the fault in good time to enable me to have more time on those more difficult faults, thank you for your video very helpful. Jamie

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety +3

      You are more than welcome Jamie 🙏
      They aren’t trying to trip you up, so keep it simple.
      If the circuit breaker is operating, then exactly as you say, you have a short circuit fault, so straight to IR tests 👍

    • @jamiemaxted2371
      @jamiemaxted2371 Před 2 lety +1

      @@Pure_electrical_training thank you so much for getting back to me so quick. keep up the good work

  • @ek6868
    @ek6868 Před 3 lety +2

    Tanx for the upload i bet it's not that straightforward and easy in the real world,especially if your going into smelly and dirty customers house's.

  • @rallyjaymuhindo6399
    @rallyjaymuhindo6399 Před 3 lety +2

    one thing to consider is that the same board has been used for fault rectification several times by several people. If I find a fault that was left by a previous person but its not the fault they expected me to find in the exam, Do I get marked down or do I still get a mark? Because people are racing against the clock during the exam and they may leave some points loose or misconnected when they put staff back together and move onto the next fault. Some people have across this.

  • @jamesjackson2998
    @jamesjackson2998 Před 10 měsíci +1

    Got my AM2s coming up soon. Just a quick question…..
    I was told on the pre-assessment that we would have to fault find on a piece of CAT-5. No problems there, but….there was no mention of testing the continuity of the CAT-5 during inspection and testing. As we are testing our own installation, and CAT5 being part of that installation, would the CAT-5 circuit need to be tested during the continuity stage of inspection and testing?

    • @Pure_electrical_training
      @Pure_electrical_training  Před 10 měsíci

      That is a great question and I would say absolutely.
      Otherwise, how would you prove this was working and it might cause you to fail when they strip your install down.

  • @mpbuilder
    @mpbuilder Před rokem +1

    Lovely

  • @grahamhamlin674
    @grahamhamlin674 Před rokem +1

    Great video , I’ve failed my fault finding twice now, out on site I can do it no problem but not on am2 , I can’t get my head around the heating fault they do it says programmer calls for heat but doesn’t work I messed it up both times , how would I find it would I just start with basic testing

    • @Pure_electrical_training
      @Pure_electrical_training  Před rokem +1

      Try this and let me know how you get on
      Boiler wiring made easy
      czcams.com/video/rAYc64MsUYI/video.html

  • @harrycharters9607
    @harrycharters9607 Před 6 měsíci +1

    Great video,
    Would an open circuit on earthing conductor be classed as earth fault or open circuit ?

  • @salty8627
    @salty8627 Před 5 měsíci

    When you spoke about the mis conection with the continuity tester, would it pick up short between L-N too? Or does it just beep on continuity of conductos? Meaning if i had a fault and i thought it was a short, but i use the tester and it beeps on L/N then the short is now ruled out and now it is a mis connection? Hope this makes sense!

    • @Pure_electrical_training
      @Pure_electrical_training  Před 4 měsíci +1

      If you use a continuity tester between line and neutral, you may pick up the resistance of any loads connected in the system, a low ohm resistance tester will give you more feedback due to the readings, rather than just a beep that could mean anything.

  • @faysalmehrban2161
    @faysalmehrban2161 Před 9 měsíci +1

    good vid 10/10

  • @rhysmorgan3057
    @rhysmorgan3057 Před 2 lety +2

    Wicked video👍🏻 not sure if you know but you get bonding faults and D.O.L motor faults too just wondering if you can cover these aswell.
    Cheers

  • @gbelectricks
    @gbelectricks Před 3 lety +2

    I sat my am2 quite some time ago!!! Has the wording been changed from reverse polarity to mis-connection?
    Great video btw👍

  • @ryanvesey8645
    @ryanvesey8645 Před rokem +1

    Hey, would a cross connection give you the same reading on a IR test as a short circuit ? Eg cross polarity live and neutral ? Thank you.

    • @Pure_electrical_training
      @Pure_electrical_training  Před rokem

      Quite possibly because anytime line and neutral are connected together with a resistance of negligible impedance, you get a dead short

    • @ryanvesey8645
      @ryanvesey8645 Před rokem

      Thanks for the reply , what is the best approach to determine if it’s a dead short or a cross connection ?

    • @Pure_electrical_training
      @Pure_electrical_training  Před rokem

      @@ryanvesey8645 In the assessments a dead short is obvious and will be the most likely choice for that type of fault.
      A misconnection is more likely to be something that isn't working correctly, like on the boiler or two-way switching.
      If there was a short circuit due to a misconnection, the fault would be proved by testing end-to-end and realising that the connections are incorrect.
      Most likely, can also be operated by a switch.

  • @adamnazihmurray8874
    @adamnazihmurray8874 Před 2 lety +1

    I had my am2 last Sunday and I have been out of the tools for a long time due to personal reasons . I have six month to complete the NVQ and the Am2 . I have not received my results yet but I really struggled and I didnt complete two sections of the installations due to some mistakes that I made. I didnt complete the fault finding because I got stuck on a fault and I took too long on it. I would like to ask you when your testing for a fault and you get a reading how do you know which fault it is ? Sorry it may sound like a stupid question. If you get no reading between a conductor than I take it s its an open circuit but what about the other faults ? is there anyway you can practice fault finding ?

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety

      Why do you only have 6 months to complete the NVQ and AM2?
      Fault finding and testing are intrinsically linked, when you are testing R1+R2 and R1+RN you are checking for continuity and proving polarity. When you are testing insulation resistance, you are testing between line and neutral for short circuits and live to earth for earth faults.
      You do that before you put a circuit into service and that is fault finding.

    • @adamnazihmurray8874
      @adamnazihmurray8874 Před 2 lety

      ​@@Pure_electrical_training well they are changing the
      qualification experience interest do you know anyone who failed the whole modules on the first attempt ?

    • @adamnazihmurray8874
      @adamnazihmurray8874 Před 2 lety

      They are changing the qualification criteria now, during the new year you will need at least five years experience, 18 edition and the initial verification qualification,

  • @michaelcostello6991
    @michaelcostello6991 Před 2 lety +1

    If a socket has wrong polarity L&N does it cause a problem if an appliance is plugged in ? Does anything trip etc . Would the customer have any issues ?

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety +2

      Most appliance can run in reverse polarity and you would never know.
      Where it makes a difference is with switching, isolation, over current and protective devices.

    • @michaelcostello6991
      @michaelcostello6991 Před 2 lety

      @@Pure_electrical_training Thanks. I knew about over current safety issues. The fact that most appliances run without issue and customer would not know is scary. Also having no isolation is scary. Great information.

  • @paulgerrard2529
    @paulgerrard2529 Před 2 lety +1

    Hi do you have or know of a video helping with the professional discussion, just after a bit of advice.

  • @MrAvosetta1
    @MrAvosetta1 Před 10 měsíci +1

    When you say test the pump, how do you go about doing that would that not be classed as sensitive equipment?

    • @Pure_electrical_training
      @Pure_electrical_training  Před 10 měsíci

      You can still pass 250V across line to Neutral, Line to Earth, Neutral to Earth.
      Or
      A low Ohm Resistance test to prove their is the correct resistance between line and neutral on the windings.

  • @jamiemaxted2371
    @jamiemaxted2371 Před 2 lety +1

    Hi Adrian,
    Sorry mate me again :) something has been bugging me ever since i've contacted you a day ago and i just wanted to see if you could clear it up for me as i know you'll have the simple answer.
    during the AM2 there was a number of fault finding situations where the circuit breaker had tripped, as we discussed in my previous post i would initially look at an Insulation Resistance test for a short circuit etc however IF the IR test was good and all cables were fine, would you then start to look at a potential misconnection/polarity fault? If were going by the 4 faults they have in the AM2 (Open Circuit, Short Circuit, High Resistance and Misconnection) am i right in saying the only other fault it could possibly be is a misconnection due to the MCB operating?
    Thank you Jamie

    • @Pure_electrical_training
      @Pure_electrical_training  Před 2 lety +1

      I don’t know the exact faults that NET have put into their assessment, but it is a possibility that you may have to check for a misconnection.

  • @beatnik1989
    @beatnik1989 Před 3 lety +1

    Does anyone know if C&G 8202 is the first step to becoming an electrician? This is the only college course I can find that does part time.

    • @Pure_electrical_training
      @Pure_electrical_training  Před 3 lety +1

      The 8202 course has taken over from the 2365 course, and it is the first step on the self funded route

    • @beatnik1989
      @beatnik1989 Před 3 lety

      Thanks Adrian! That helps me a lot. It’s a minefield out there when looking to switch careers.

  • @95555219
    @95555219 Před rokem +1

    Will there be a fault that “light always on “in AM2?

  • @wilfbrocklebank133
    @wilfbrocklebank133 Před 3 lety +2

    I have to sit this in the next few weeks, fail last time on rectification

  • @drpantastic1969
    @drpantastic1969 Před rokem +1

    499 i wanted to be like 500