Design of Combined Footing for Tied Columns - Tagalog Tutorial
Vložit
- čas přidán 3. 11. 2022
- This tutorial video will guide the viewer on how to design a combined footing that supports tied columns. It starts from calculating preliminary size in order to achieve soil pressure, then followed by analyzing critical shear and bending moment.
Finally, once critical stresses Vmax and Mmax are calculated, next step are sizing of footing thickness plus the required rebars along main axis.
Have fun watching and learn!
Another tutorial episode.Thanks for sharing
Sir ano po ung ginamit nyo na value ng " b " para makuha ung 505mm na effective depth
Thank you big help as reference course
How about combined rectangular footing with eccentric load po? Pano po yun idesign
sir what if nasa corner at edge ang dalawang columns?
Pwde po ba kayo mag tutorial for strip foundation when designing a foundation with constraints given area for the foundation. Many thanks, po.
Hello po. Saan po galing yung width na 1.40m? Salamat po!
Gud eve po sir, Nscp or aci po ito?
js design po baa and js contractor same company po???ty
Sir lodi, 3units of footing magkakalapit (space lng nila in between 0.40m) need ba maging combined footing. And nakatop and bottom rebars po sya? Thank you po. Newly follower nyo po.
Okay lang maging isolated, but for convinience in construction you can combine them together. Thanks
Sir quick question lang po. Kailangan pa rin ba mgkarron ng tie footing sa low rise building say ground pius 1 floor or plus 2 floor? Salamat po sire. More power sa channel ninyo.
Hindi mo kailangan ng tie beam kung shallow footing. Standard depth 1.20m
Isa pa, nag lalagay lang tayo ng tie beam kung mataas yung ground to second floor para hindi slender yung column. Standard height 3.00m
sir usually ba walang moment nagooccur sa footing design? kasi lahat ng theoretical computations is axial loading lang and samples
Yes meron kaya nag lalagay tayo ng rebars. Thanks
Sir ano po ginamit nyo na "b" bakit 505mm yung depth. Salamat sa pagresponse
nag kamali yata sya intead of b=1400 naging 1800mm
Good day good sir, have you ever encountered a corner combined footing? Okay po ba ang ganun na footing sa actual?
Yes it happens when building is constructed along property line.
Eccentric footing, we can reduce eccentricity by providing tie beam.
sir what if theres bending moment present came from column?
Bending from column will be partially absorb by footing, that means you have to add that effect in your point load. Thanks
Good day po! Kailangan po ba mag moment from left hand side at right hand side para po sa moment diagram or kung saan lang po pinakamalapit yung lever arm dun lang po tayo mag momoment?
You can choose in either left or right hand side, whichever is easier to perform the equation. Thanks
@@jsdesign_engineeringtv3633 good day po! Different po kasi ang nakukuha sa right at sa left, based po dun sa book ni Engr. Mark Castro.
In that case, use the max. value