PLUMBING REPAIRS | NAVIEN NCB 210 | 3 WAY VALVE REPLACED

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • A navien combi boiler ncb 210 has error code E.001. A wrestling match. Check this one out.
    Subscribe- / chuckbarron
    kit.co/ChuckBa...
    Every day plumbing repairs and installs featured all while my two sons CB2 and Angelo learn the plumbing trade.
    Subscribe- / chuckbarron
    Follow us on social Media
    / charles.barron.9
    / chuckbarron6
    / chuckbarron6
    DISCLAIMER: This video is for entertainment purposes only. This video also contains affiliate links which if you click on link and make a purchase I may receive a small commission. This helps support the channel and helps us continue to bring you new video's like this one. Thank you so much for the support. Plumb on!
    Check out some of our gear-chuckbarronplum...
    #plumber
    #plumbing
    #plumbers
    #plumbingapprentice
    #plumbingrepairs
    #journeymanplumber
    #serviceplumbing
    PLUMBING REPAIRS | NAVIEN NCB 210 | 3 WAY VALVE REPLACED

Komentáře • 80

  • @thomasfallon6656
    @thomasfallon6656 Před měsícem

    I'm a service plumber in NJ, this video helped me out a lot. Thank you Sir!

  • @philz7542
    @philz7542 Před 2 lety +1

    Excellent video on replacing the 3 way valve. Thank you sooo much for the tip about reusing the old brass mount plate. Took the new washer, left off the new brass plate and reconnected the 3 way. I replaced the pump while I was at it. The clip that secures the pump was a bit of a bugger to get back into place, and I would recommend that if you're replacing the pump, that you should pre-screw the holes on the bottom around where the pump drain plug goes, so that the screws go in easily to secure it to the cabinet. I didn't really want to replace the pump, but the level 2 tech at Navien said that for sure the 3 way was pooched because we were getting bleeding back into the heating loop, when no heat was called for. The tech said that although the pump may be working, the pressure numbers coming back on the display said that the pump may be having an intermittent issue, or beginning to fail. Your video with explanation, was phenomenal. Thank you
    Is there a repair kit for these pumps? How do you test the pump to see if really pooched? The pumps have a screw out for the bearings , I think. They look very similar to a Grundfos heating pump.

  • @jakevalis6242
    @jakevalis6242 Před 3 lety +2

    Been in the trade a couple of years now, always reference your videos to help me learn. This is the most in-depth channel I’ve ever seen. Feels like I’m standing right next to you learning first hand. Thank you from Toms River.

  • @Reese_Young
    @Reese_Young Před 3 lety +3

    My love for plumbing was tested 2 weeks ago or so having to replace the same 3 way valve. Still love it but was not happy that day. I will have to keep that idea of reusing the old brass plate because thats where i ran into troubles to thanks for the tip. That would have saved a lot of swearing lol.

  • @se032131
    @se032131 Před 3 lety +1

    Take a look at mikey pipes on youtube about navien heat exchange issues. I saw some indicators in your videos too.

  • @Ted_E_Bear
    @Ted_E_Bear Před 3 lety +2

    Your work is beyond reproach !!

  • @frankvon3980
    @frankvon3980 Před rokem +1

    CB, Nice job! Its seems like i'm standing right next to you while your doing the job.! The manufacture should have that valve facing to the left side of the panel, along with an easy access panel for easy replacement.

  • @traderpete007
    @traderpete007 Před 3 lety +3

    Seems more like a car mechanic on a compact car vs plumbing & heating.

  • @watomb
    @watomb Před 5 měsíci

    Older model but that error drove me crazy. It would work most of the time. But every so often give that error. Although replacement parts where free

  • @ptech88
    @ptech88 Před 9 měsíci

    I have replaced many of of these. They suck to replace. I am at the point now where i remove the boiler from the wall and replace the three way then reinstall it on the wall. It is much easier access

  • @JE27898
    @JE27898 Před 3 lety +2

    Maybe someday they'll make extra access panels.
    Nice job Chuck

  • @billriga2825
    @billriga2825 Před 3 lety +1

    Great job Chuck, also camera work is exceptional!!!

  • @johnadams2630
    @johnadams2630 Před 3 lety +1

    Brave soul!! I’ve been pro Navien for about 5 years. I haven’t had any issues with proper maintenance of flushing the unit. Well designed but costly. I wish they had a parts kit at our local vendors. They don’t give them away even with proper training. That’s the only downfall I have found with this Roles Royce

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      Thanks for sharing

    • @greekmaster1001
      @greekmaster1001 Před 2 lety

      I've seen alot of complaints on the naviens and I mean ALOT of issues especially the ncb models

  • @woody9052
    @woody9052 Před 3 lety +4

    These systems seem to be more trouble than they are worth.

    • @jasonyeager9102
      @jasonyeager9102 Před 3 lety +1

      Agreed; just the smallest thing can mess them up. And require annual maintenance. Definitely a pain to work on.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      not if serviced and install correctly. Trust me I have learned from my mistakes.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      true that.

  • @anniesfarmhousebarngrill446

    Chuck barron "THANK YOU Thank you THANK YOU" FOR YOUR PERFECTLY EXPLAINED HAVIEN 3 VALVE SWITCH REPLACEMENT video. Havien said being I'm a woman that I had to have a licensed plumber call there technical support to do the job. SO I did plumber came no parts said he ordered it overnight.comes back next day.rips it apart no gaskets.my advise always replace gaskets o rings always.But no he is a professional right. Wrong. So long story short plumber leaves aggravated parts all over the place screws everywhere.House with no heat or hot water now.Temperatures in 30s 2 small children and a 80 yr old mother cold and can't shower.i call plumbing places for parts locate a place 2 hr away round trip.Great part of story wish I had someone to video tape me.I come home Watched your video 😀 Started putting it back. Together you would be proud of me and your video Chuck because I was so confident I even figured out a trick to show you how to replace the brass piece without a disaster or bigger headache. Put in all new greased o rings.Took me a little over an hour. I purged it all out to clean it And in excitement to all HEAT AND HOT WATER. 🔥 Again thank you Chuck 2 thank God for my small hands. And HAVIEN THANK PEOPLE LIKE CHUCK AND DONT TREAT WOMEN LIKE THERE STUPID BECAUSE AT LEAST NOW IM A PRO THANKS TO CHUCK. 👍 AND CAN FIX YOUR HAVIEN BETTER THEN YOUR SO CALL MALE PLUMBERS. THAT TALKED TO HAVIEN SUPPORT GOT AGGRAVATED CAUSE YOU MAKE EVERYTHING LOOK COMLICATED AND THET QUIT. HAVIEN WHEN YOU WONT EVEN GIVE A HOMEOWNER AN AVERAGE TIME FOR LABOR AND PARTS NO WONDER EVERY HOMEOWNER WANTS TO THROW YOUR PRODUCT IN TRASH. ITS A GREAT WATER HEATER AND HEAT.VERY WARM GREAT HOT WATER BUT HAVING CONTRACTORS CHARGE THOUSANDS OF DOLLARS FOR A JOB THAT TAKES AN HOUR AND PARTS WAY UNDER A 100.00 DOLLARS HIGHWAY ROBBERY .SHAME ON YOU HAVIEN. AND PUT ACCESS PANELS ON THE SIDE IT DOESNT COST YOU ANYTHING MORE GREAT PRODUCT IF YOU STOP CONTRACTORS FROM RIPPING OFF YOUE CUSTOMERS. HAVIEN IF IT REALLY TAKES YOUR LICENSED CONTRACTORS 3-12 HOURS FOR A ONE HOUR JOB AND IM JUST A BEGINNER MY 1ST TIME CALL ME INSTEAD TO ALL THE CRY BABY MEN WATCH CHUCKS VIDEOS AMAZING.AND TO ALL THE WOMEN DONT LISTEN TO HAVIEN. YOU CAN DO ANYTHING TO THANKS TO UTUBE AND CHUCK.Havien should sale your own parts also because if you didn't send me on a wild goose chase looking for parts on line like you said I never would have found Chuck 😉 and if anyone wants parts go to Roche plumbing supplies lake Ariel highway honesdale pa. Low prices also. Proud of my havien once again

  • @toddcook2016
    @toddcook2016 Před 3 lety +1

    nice job chuck

  • @miketo5828
    @miketo5828 Před 3 lety

    Thanks buddy, be safe

  • @rainmaker3700
    @rainmaker3700 Před 6 měsíci

    Good video Chuck, but you guys make this job way to hard. I have replace dozens of these, it's not the actual spring valve that fails, it's the cheap plastic cam and motor that fails from constantly actuating when in recirc mode. You can replace the motor, cam assembly without pulling the pump and 3way valve body, its just 4 screws on the top of the valve body. You do have to remove the pump venting and piping to the exchanger and get them out of your way. Pull the motor off of the top and replace it along with the contacts and cam, plug in the new connectors. Relatively easy repair. 99% of the time, the spring valve is working fine, but you can test it by depressing it with your finger when you remove the motor assembly.

  • @throttlebottle5906
    @throttlebottle5906 Před 3 lety +2

    if that was in my own, I'd be mad enough to cut the side of case and bend it out of the way for permanent easy valve access lol.
    you'll probably be about that mad at it when it fails again sooner than later too.

  • @jeffreybear7067
    @jeffreybear7067 Před 3 lety +1

    CB 1 love your videos!. Have a ? We bought a outdoor Rinnai tankless hot water heater. We live in Montana where it can get down to -20 or more with wind chill. Is there a way you can install these outside with cold temps. Like this. It’s hard to find a good plumber here and I know you know your stuff thank you .

    • @throttlebottle5906
      @throttlebottle5906 Před 3 lety +1

      I would never put an outdoor unit where average winter temps and the 100 years low would go below freezing. one long power outage and it's history ;)

    • @ChuckBarron
      @ChuckBarron  Před 3 lety +1

      actually we have a housing project that built diamond plated insulated units to house a bank of naviens to prevent freezing.

  • @BrianBeamers
    @BrianBeamers Před rokem

    I wonder what my issue with my Navien. I don’t get an error code.

  • @jorgeub27
    @jorgeub27 Před 3 lety +1

    If you dont mind me asking. What are the symptoms what is the reason you are changing it?

    • @J-Colt
      @J-Colt Před 3 lety +1

      It is a piston valve and probably stuck in partially open position.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety +1

      no hot water was this system. Dr. Tech support sent me in right direction.

  • @mikedefilippis7837
    @mikedefilippis7837 Před 8 měsíci

    Just had one of those shoot the same error code 001 and it was because of a gas leak on the top of the heat exchanger. I would shoot the code intermittently. All I do is repair These junkie units.

  • @suckamc3232
    @suckamc3232 Před 3 lety +2

    Have done a couple 3 way replacements not fun they need to make easier moving board, circ just to get to it

  • @RES_Plumbing-Drain
    @RES_Plumbing-Drain Před 3 lety +1

    I had exact same error code and symptoms on brand new unit, then it started to work normally, go figure.
    How fast can you get spare parts for Navien? readily available?

    • @jasonyeager9102
      @jasonyeager9102 Před 3 lety +2

      If you are or have Navien certified techs you can get what is essentially a large tool box that has various different pieces and parts excluding a heat exchanger.

    • @jasonyeager9102
      @jasonyeager9102 Před 3 lety +1

      However, if the system is still under warranty they don’t like you just changing parts; typically we get them next day from Navien

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      we have local supply houses that handle them.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      on my hot list to do....a must. I gotta get there.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      true that jason. they are great.

  • @throttlebottle5906
    @throttlebottle5906 Před 3 lety +1

    she's spitting ducks at ya, did you forget the header service valves shut? that leaves the expansion tank and rest of system isolated with no where for water to expand when it fired.
    that would rapidly expand and skyrocket the water pressure inside the boiler making it spit ducks out the relief.
    either always open the service valves first or better yet shut the gas supply off, power it up and purge the air out, run domestic hot water so it diverts and purges the heat exchanger also. probably have to go through a couple lockout/reset cycles, then open all valves, turn gas on and reset for the last time.

    • @throttlebottle5906
      @throttlebottle5906 Před 3 lety +1

      actually, they may have some sort of service menu with purge function. then again over engineered cruft.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      a real duzzy

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      mental job right here.

  • @brewmule6799
    @brewmule6799 Před 3 lety

    Bloody knuckles and Chuck hearing her suck all the air!!! Be good to Daddy! Lol

  • @jasonyeager9102
    @jasonyeager9102 Před 3 lety +1

    Lots and lots of small screws in all those Naviens

  • @mfplumbing9341
    @mfplumbing9341 Před 3 lety +1

    open pressure releif valve when filling maybe sounds like air

  • @Brad-jg9vh
    @Brad-jg9vh Před 3 lety +1

    How do you buy a hoodie from Barron? Huh Chuck? :)

    • @ChuckBarron
      @ChuckBarron  Před 3 lety +1

      The boss supposed to set up store...we so busy. Its coming i just do not know when

    • @Brad-jg9vh
      @Brad-jg9vh Před 3 lety

      @@ChuckBarron Thanks!

  • @mikev.1034
    @mikev.1034 Před 3 lety +1

    👍👍

  • @jamescordes8673
    @jamescordes8673 Před 3 lety +1

    Please people. Don’t get Navien’s. They suck and even suck more to work on. Also avoid getting combi units of any kind. Those 3 way valves always go. Get a nice burnham alpine.

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      I love me some naviens but ok.

    • @jamescordes8673
      @jamescordes8673 Před 3 lety

      @@ChuckBarron just bad experiences lol. We had one summer half of our installs were Navien warranted swap outs. So many leaking heat exchangers. Navien tried to blame the water but we have customers on everything imaginable. One guy even has city water with a UV system. And their customer support is either really good or really bad. Had one time a relief valve was blowing cause whenever it switched to hot water the heating side pressure would increase and blow the relief valve. Their customer support recommended replacing the pressure sensor....I tried explaining to them I had a mechanical safety going off and the sensor is working cause it’s at 29 and won’t go higher because of that valve and he didn’t seem to understand and hung up on me.

  • @keithbrueton
    @keithbrueton Před 3 lety +1

    No safe Isolation CB just get in there

  • @JamesBrown-db9pk
    @JamesBrown-db9pk Před 3 lety +1

    put the gloves on 1st then play with the hot stuff

  • @keithbrueton
    @keithbrueton Před 3 lety +1

    8.12 LOL CB

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      what up brother. lets do a live 5 am....i know your up then...ha

  • @JamesBrown-db9pk
    @JamesBrown-db9pk Před 3 lety +1

    thats y me and lav dont sell that crap

    • @ChuckBarron
      @ChuckBarron  Před 3 lety

      James give me your cell.....lets chat brother....email me....barron9650@gmail.com