MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD

Sdílet
Vložit
  • čas přidán 29. 08. 2024
  • MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD

Komentáře • 87

  • @amirhussain4637
    @amirhussain4637 Před 6 měsíci +1

    Kys bt hai bht acha Tariqa r zbrdast Information maza agya

  • @amitpagare5946
    @amitpagare5946 Před 3 lety +1

    Very informative video 🙏🙏👍

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety

      Thank you sir 😊
      please support the channel...
      subscribe and share

  • @pramodsahoo1375
    @pramodsahoo1375 Před 3 lety +1

    Thank you sir, valuable video. But it's a standard software. Plz make a video hoist software.

  • @technogamergaming1504

    thanks sir for your for making this vidio please make more this type of full vidio on all vfd and mainly yaskawa and danfoss and delta

  • @akhtarshamim2424
    @akhtarshamim2424 Před rokem +1

    Love brother

  • @sujitsutar4953
    @sujitsutar4953 Před 3 lety +1

    Thank you sir....🙏🙏

  • @veereshh1824
    @veereshh1824 Před 8 měsíci +1

    Dear Sir
    Drive is tripping on overcurrent fault.
    But actually no overcurrent, taking Normal current while tripping.
    Please suggest how to solve the problem.

    • @bishantkumar12589
      @bishantkumar12589  Před 8 měsíci

      Put the drive to scalar mode and check veeresh Anna

    • @veereshh1824
      @veereshh1824 Před 8 měsíci

      @@bishantkumar12589 Sir it is not Tripping immediately, it is tripping after sometime.

    • @veereshh1824
      @veereshh1824 Před 8 měsíci

      How to set control Board temperature and it can Bypassed?

  • @ranjangupta5700
    @ranjangupta5700 Před 2 lety +2

    Sir How to set minimum speed that motor will achieve while starting VFD? and sir what is "1- 89.1%" written in the Top of the digital display?

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      In parameter 11.04 - set the minimum speed which is required, in there video, it's 0, set as required.
      &
      On HMI - 1-89.1% is the reference given by control room to run the VFD (out of 100%)

    • @ranjangupta5700
      @ranjangupta5700 Před 2 lety

      Thank You Sir! I have one more doubt ,What is meant by Jog speed or when we select Jog speed ?

  • @rakesh78070
    @rakesh78070 Před 3 lety +2

    Thank you Sir...I have one doubt how can i clear maximum fan running hours alarm in ABB ACS 800 VFD

  • @arunvishwakarma6812
    @arunvishwakarma6812 Před 3 lety +1

    Sir plz make a video over dtc mode selection and parameters for dtc mode and how to set range of torque

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety +1

      Sir. As per my knowledge, DTC mode is selected only for applications where high precision of movement is needed. For general,scalar mode is okay.
      Torque is generally unchanged : -300 to +300 is set

    • @arunvishwakarma6812
      @arunvishwakarma6812 Před 3 lety +1

      @@bishantkumar12589 okay sir

  • @pramodsahoo1375
    @pramodsahoo1375 Před 3 lety +1

    As I know, torque is different in star and delta but why motor always connect in delta for vfd control.

    • @bishantkumar12589
      @bishantkumar12589  Před 3 lety

      Sir. It's very thoughtful observation u did. Great.
      As of now I don't know surely y its VFD motor r connected in delta but...
      In my observation,
      I have seen only HT motors (6.6kv) are connected in Star , they need very high torque while starting of equipment.
      Else all LT motors are connected in delta.
      Still, I'll check for better results and revert ASAP sir. TQ

  • @sanjaykesarkar1918
    @sanjaykesarkar1918 Před rokem +1

    Why can't given information about ID run. Its important Parameter.

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      It's big topic sir and there's a complete separate video on it. U may check my ABB playlist for all the details

  • @kevin00861
    @kevin00861 Před rokem +1

    Dear Sir,
    Thank you for your video,
    I kindly need your help,
    ABB VFD ACS800-01 , some parameter groups do not show up on the local control panel, the only parameter groups that show are 10, 11, 14, 16, 33 the rest do not show. And also the language selection which should be in group 99; it shows in group 33.
    I could not find any related setting in the drive manual.
    any clarification, please

    • @bishantkumar12589
      @bishantkumar12589  Před rokem +1

      You must speak with your ABB service engineer.
      I am also a field engineer, do not know that much in details.
      If you still need help I can talk to my ABB service engineer but he is chargeable.

    • @kevin00861
      @kevin00861 Před rokem

      @@bishantkumar12589
      Yes please,
      I would be so grateful to you Sir
      would you share your email or WhatsApp number so i can send you the photos and video

  • @NICE_LIFE1986
    @NICE_LIFE1986 Před 2 lety +1

    Sir,
    If I operate drive to MCC panel.
    Is put same parameters according yo this video pls confirm.

  • @terus_belajar-
    @terus_belajar- Před 2 lety +1

    I have Acs800, I have problem that acs800 have fault BR Wiring (7111), can you tell me how to fix it?

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      Sure sir. I'll check and let you know

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      BR WIRING
      (7111)
      3.17 FW 5 bit 1
      Wrong connection of brake resistor Check resistor connection.
      Ensure brake resistor is not damaged.

  • @rashadmuhammad8554
    @rashadmuhammad8554 Před rokem

    How I can increase rpm hz settings while drive is running on profibus mode

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Sorry, I don't have that information. Pl contact your service engineer

  • @durgeshkadu8181
    @durgeshkadu8181 Před 2 lety +1

    I want 440volt output voltage at 27HZ nominal frequency I have set I have set all parameters as per name plate data in para. 99 ... The voltage is still 415-420 volt output what should be done else for getting 440volt output at 27Hz freq output frequency.

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      I believe these drives are designed for 0-50hz frequency only with 0 Hz= 0 V and 50 Hz = 415V,
      But, you can change the minimum and maximum speed in the limit parameter, you will get the desired voltage at 27Hz.
      Try this, if u don't get, text me back

    • @durgeshkadu8181
      @durgeshkadu8181 Před 2 lety +1

      @@bishantkumar12589 I have checked in limit parameter 20 here min freq. I setted 0 hz and maximum 27hz then also output voltage is 415volt as I set 440volt nominal voltage in para 99...here I m not seems minimum and maximum RPM setting

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      @@durgeshkadu8181 what's the speed at 27Hz. ?

    • @durgeshkadu8181
      @durgeshkadu8181 Před 2 lety

      @@bishantkumar12589 currently I am testing without load and I seems voltage does not boosted to 440volt and I have tested 4pole motor with this parameter nominal voltage 440volt nominal frequency 27hz and motor design for 415v, 50hz due to motor gets overloaded at this stage even at no load .. It was trial at 4pole motor actually I want to test 440volt , 27hz , 12pole motor which is under production

  • @praveenkumar-uu6ht
    @praveenkumar-uu6ht Před 3 lety +1

    How to ser drive parameter using vfd drawing

  • @user-nl4yc5vq3y
    @user-nl4yc5vq3y Před rokem +1

    Assalamu alaikum
    Hamare pas ACS800 drive hay jes may group 99.1 se direct 99.9 pe chala jata hay motor data nahe araha parameter stat group 14 se ho jata please help
    Younas cherat cement

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      namaste ... aapke drive me kisi ne parameters ko lock kar diya hoga... parameter number - 16.02 PARAMETER LOCK , check karo aap. agar 65535 hai too lock hai, 0 hona chahie.

    • @user-nl4yc5vq3y
      @user-nl4yc5vq3y Před rokem

      @@bishantkumar12589 janab shukreya check kar ke aap se contact kar longa. Unlock ka koe pascode hay??

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      @@user-nl4yc5vq3y ye too apke company ka incharge ya abb service engineer wala hi bata sakta hai kya set kiya hua tha

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      agar aapko mere videos saahi lagte hai too please apne electrical dosto k sath v share kare is channel ko. thank you

    • @user-nl4yc5vq3y
      @user-nl4yc5vq3y Před rokem

      @@bishantkumar12589 zaroor karonga

  • @rishinathreghu579
    @rishinathreghu579 Před 2 lety

    hi sir, my abb acs 600 drive have i/o comm fault.what is the reason and how to troubleshoot and solve.

  • @NICE_LIFE1986
    @NICE_LIFE1986 Před 2 lety +1

    Sir,
    I have Acs 800 drive how to speed control by Protections meter.
    Kindly share Basis parameters Acs 800 drive.

  • @nikhilmishra3951
    @nikhilmishra3951 Před rokem +1

    Sir acs800 vfd me encoder ko bypass kaise kre

  • @9368737888
    @9368737888 Před 2 lety +1

    How to reset complete parameter

  • @omkarkumar5000
    @omkarkumar5000 Před 2 lety +1

    Sir abb ACS 1000 main water temperature reference setting kon se parameters group main milega please reply

  • @Fire_palace
    @Fire_palace Před rokem +1

    ABB ACS 800 vfd parameter UPLOAD & DOWNLOAD using Drive 🪟. Please make 🙏 a video please 🙏 Sir.

  • @aghashahzad460
    @aghashahzad460 Před 2 lety +1

    Bro kindly explain master slave parameter of acs800 kindly share

  • @earntechsv5384
    @earntechsv5384 Před 2 lety +1

    Moter stop hone ke bad reverse aa rha hai ky falt ho skata

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      Motor reverse run ho raha h kya ?

    • @earntechsv5384
      @earntechsv5384 Před 2 lety

      Ha sir rukne ke bad thoda reverse ghum rha hai kis parameter ka problem ho skata hai sir please tell us

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      @@earntechsv5384 pump application hai kya ?

    • @earntechsv5384
      @earntechsv5384 Před 2 lety

      Nhi sir EOT CRANE ME ABB ACS 800 DRIVE LAGI HAI USKA USE FORWARD REVERSE MOTION HAI USI KI PROBLEM Hai

    • @bishantkumar12589
      @bishantkumar12589  Před 2 lety

      @@earntechsv5384 okay main check karta hu

  • @PintuVerma-cv9uk
    @PintuVerma-cv9uk Před 3 lety +1

    सर ACS लिखा हैं मॉडल मे उसका मतलब या फूल फॉर्म क्या होता हैं

  • @vaibhavdave1016
    @vaibhavdave1016 Před 2 lety

    Sir hamare pass ACS 800 hai.. usme fiber optic thi mod bus ke sath hoke PLC ma communication jata hai..
    Abhi fiber optic ka light thik hai fir fir bhi communication nhi mil raha or..
    Eroor hi ata hai.. communication module 7510 vala

  • @sujitsutar4953
    @sujitsutar4953 Před 3 lety

    Danfoss drive ka video kijiye.

  • @user-rj7hs6lm1e
    @user-rj7hs6lm1e Před 14 dny +1

    Hello sir 🙏 app k what's up number chahe sir Mai Nigeria Mai Job Kar hoo mera question tha Discussion Karn hai plz Sir. From odisha Jay Jagannath 🙏

    • @bishantkumar12589
      @bishantkumar12589  Před 14 dny

      Hello bhai. Kya problem hua h. Batao. Kaun si company me ho waha ? Quantum group?

  • @mdmasumbellah6487
    @mdmasumbellah6487 Před rokem

    Sir how to contact with you...plz

    • @bishantkumar12589
      @bishantkumar12589  Před rokem

      Pl ask ur doubt. Here

    • @shrikantha76
      @shrikantha76 Před rokem

      @@bishantkumar12589 in my case I am getting fault in LT drive as ACS800 Temperature fault when we operate above 2nd step speed where as Temperature is normal inside E room. Please suggest what is the remedy? Thank you..

    • @mdmasumbellah6487
      @mdmasumbellah6487 Před rokem

      @@bishantkumar12589 I want to send a problem video clip