Off Grid Because We Can!

Sdílet
Vložit
  • čas přidán 27. 03. 2024
  • Installing one of the biggest off grid systems we've ever done!
    Pytes V5 Lithium batteries:
    practicalpreppers.com/product...
    Buy a Sol-Ark 15k!
    practicalpreppers.com/product...
    Let's discuss your solar goals:
    practicalpreppers.com/consult...
    Order KB Solar modules
    practicalpreppers.com/product...
    Get an EMP hardened DIY kit:
    practicalpreppers.com/product...
    Our pressure canners are back in stock and in fun new colors!
    bit.ly/3IdOgWJ
    Get an eBike:
    Join our Discord server!
    / discord
    Follow me!
    / practprepllc
    / engineer775
    / simplysustainabl. .
    / practicalpreppers
  • Zábava

Komentáře • 169

  • @engineer775
    @engineer775  Před 3 měsíci +20

    Installing one of the biggest off grid systems we've ever done!
    Pytes V5 Lithium batteries:
    practicalpreppers.com/product/pytes-v5-lfp-battery/
    Buy a Sol-Ark 15k!
    practicalpreppers.com/product/sol-ark-15k-120-240-208v-hybrid-solar-inverter-all-in-one-pre-wired-outdoor-rated/
    Let's discuss your solar goals:
    practicalpreppers.com/consultation/
    Order KB Solar modules
    practicalpreppers.com/product/kb-solar-450w-solar-panel/

    • @Pahrump
      @Pahrump Před 3 měsíci +1

      How is the Keto going?

    • @Theycallmeernie88
      @Theycallmeernie88 Před 3 měsíci +1

      Have you guys looked at the numbers/specs of an electric excavator or tractor to run the post tool thing. You could charge with the solar array while it’s out there as savings to you and the customer. 🤷‍♂️ It’d be cool if the numbers added up to give it a shot.
      Noah the ebikeschool guy seems to have found some decent looking ones.

    • @engineer775
      @engineer775  Před 3 měsíci +1

      @@Theycallmeernie88I have only seen small machines. The machines weigh less than my post driver. They would never pick it

  • @ThePirateGod
    @ThePirateGod Před 3 měsíci +61

    That customer needs to mass produce those racks. So clean and solid.

  • @chadengemann8237
    @chadengemann8237 Před 3 měsíci +74

    I would keep this guy on retainer for the next rack build

    • @brians8664
      @brians8664 Před 3 měsíci +2

      That’s what I was thinking. I would imagine turning up a production process for those is going to be expensive, even if he already has a fab shop. Volume brings cost per rack down, but they would have to move some serious product to bring it down significantly.

    • @sspyder181
      @sspyder181 Před 3 měsíci

      Super nice racks!

  • @spiralout112
    @spiralout112 Před 3 měsíci +21

    Beautiful setup! That rack of batteries... OMG

  • @AdamDeLay07
    @AdamDeLay07 Před 3 měsíci +9

    Beautiful install! Thanks for sharing! I always get lots of ideas when I see what all y'all do!

  • @TheVaga9
    @TheVaga9 Před 3 měsíci +12

    Needs more heat sink on the rack! Really do!!! Slots, vents, something!! Great setup though, and the best solar contractor on planet earth!!!

  • @hogwild9408
    @hogwild9408 Před 3 měsíci +9

    Besides venting in the races I would recommend leaving 6 to 8 inches off the floor for first batteries. Looks good.

  • @michaelchownyk5255
    @michaelchownyk5255 Před 3 měsíci +8

    That is such a Beautiful installation. Good job. you have a good crew.

  • @rei9915
    @rei9915 Před 3 měsíci +3

    Nice Project! Nice to see that in the US are Pioneers like that. I appreciate

  • @ftlaud911
    @ftlaud911 Před 3 měsíci +18

    Wow - nice build. Only thing I would have done differently was put racks on a stand or built a bigger gap at the bottom. The batteries on the bottom rows seem really close to the floor. Any type of flooding would make me extremely nervous.

    • @evil17
      @evil17 Před 3 měsíci +2

      Good idea and with opening top & bottom would potentially help airflow too.

    • @puirYorick
      @puirYorick Před 3 měsíci +1

      I was checking to see if anyone else saw those potential issues.

  • @ozark1981
    @ozark1981 Před 3 měsíci +2

    I've done IT for a number of years. A 4 post server rack with slide out rails is what you should look for. The 2 post even for IT use is only good for light things. They make some beefy rails since some servers can be 200 lbs or more.

  • @amateurwizard
    @amateurwizard Před 3 měsíci +5

    We love to see it, we love to see it.

  • @davelindgren5245
    @davelindgren5245 Před 3 měsíci +1

    Really clean looking install. Nice job on it.

  • @robertduffy5805
    @robertduffy5805 Před měsícem

    I love the layout, clean and professional.

  • @antronx7
    @antronx7 Před 3 měsíci +44

    $32k solar+racking, $21k inverters, $74k batts = $127k equipment cost plus hardware, install. Divided by 20 years expected lifetime that's $6350/yr annual equipment cost. Solar array will generate 55,000 kWh/yr = 11.5 cents / kWh electricity cost (not including labor + BOS hardware). 30% federal tax credit will pay for install cost and chunk of equipment cost. So final electricity price will be slightly less than utility and you are protected against cost increases. And this system uses premium equipment. A DIY system using less expensive inverters and a battery assembled from single cells can be had for half the price.

    • @zr1411
      @zr1411 Před 3 měsíci +3

      I'd really appreciate some suggestions from you for less expensive equipment for a DIY system (just started my research on this, which is why CZcams brought me here).

    • @antronx7
      @antronx7 Před 3 měsíci +8

      @@zr1411 6x Growatt 5000es would provide same power as 3 solarks but for $4500 total vs. $21k. They are not as nice as solarks for sure. You can build your own equivalent battery using 240x LF280K battery cells for $24k plus BMS cost vs. $74k for Pytes. Just few examples.

    • @hcjpbluesky9916
      @hcjpbluesky9916 Před 3 měsíci +4

      If it can make sense at 11.5 cents/KWh, imagine 3X'ing your payback speed by doing this where some pay 30c.

    • @LittleSpot
      @LittleSpot Před 3 měsíci +4

      @@hcjpbluesky9916 in Germany the kWh price is in 2024 around 30 to 50 ct. Depending of the region where you life.

    • @MitchOfCanada
      @MitchOfCanada Před 3 měsíci +1

      $0.30/kwh in canada after fees and that is $0.11 base +fees....

  • @kylesinclair5350
    @kylesinclair5350 Před 3 měsíci +4

    ENGINEER 775 with the T-775 Skid-steer. Good Combo for success!

  • @pytesecho1876
    @pytesecho1876 Před 3 měsíci +1

    great installation!

  • @Greg-bx4id
    @Greg-bx4id Před 2 měsíci

    Very clean. Gives me some great ideas.

  • @LeviWritesBooks
    @LeviWritesBooks Před 3 měsíci +2

    Beautiful!

  • @martingregg9970
    @martingregg9970 Před 3 měsíci +1

    Awesome look - very neat, absolutely beautiful

  • @merlesomero7807
    @merlesomero7807 Před 3 měsíci +3

    Looking good!

  • @chadengemann8237
    @chadengemann8237 Před 3 měsíci +5

    Would love this dream system

  • @sspyder181
    @sspyder181 Před 3 měsíci +1

    Clean job!

  • @RolandW_DIYEnergyandMore
    @RolandW_DIYEnergyandMore Před 3 měsíci +1

    Beautiful job!

  • @hendersonsobers396
    @hendersonsobers396 Před 4 dny

    This setup is really impressive.

  • @stili774
    @stili774 Před 3 měsíci +4

    Is this not just a rebranded deye Inverter?

  • @twinshobbytwinshobby3863
    @twinshobbytwinshobby3863 Před 2 měsíci +1

    Awesome JOB !

  • @SkypowerwithKarl
    @SkypowerwithKarl Před 3 měsíci +8

    I think that since this is a garage that I would have bollards in front of the batteries to protect them. Probably some thermostatically controlled fan to remove the combined/accumulated heat from the racks (with a thermal fire fuse) or allowance for convection cooling. A combination ionic and photoelectric smoke detector plus a heat detector above the batteries and inverter tied into the house network or internet would be a nice touch.

  • @showaltermicro
    @showaltermicro Před 3 měsíci +1

    Looks Great

  • @jamestiberiuskirk5994
    @jamestiberiuskirk5994 Před 3 měsíci +1

    Great job!!!

  • @SolarTechFL
    @SolarTechFL Před 3 měsíci +1

    Nice work man

  • @chutch332
    @chutch332 Před 3 měsíci +1

    SPEECHLESS!! Nice work!!

  • @Roll2Videos
    @Roll2Videos Před 3 měsíci +2

    That is beautiful; come up to Canada 😂 Great job.

  • @4evermetalhead79
    @4evermetalhead79 Před 3 měsíci +3

    This is the dream.

  • @diySolarPowerFunWithRay
    @diySolarPowerFunWithRay Před 3 měsíci +1

    So cool. That's a nice system! Do you know what just the equipment side of things would cost for this build?

  • @wdwtx2.0
    @wdwtx2.0 Před 3 měsíci

    Big job.

  • @mattgirgenti3595
    @mattgirgenti3595 Před 3 měsíci +1

    wow. What a great system, but the wow is for the install, organization, and attention to detail. Very impressive!! Curious the value/need for the transfer switch. Seems like both solar and generator are direct wired to the Sol-Arks all the time, yes? Trying to follow the wiring paths in my mind.

  • @margarita8442
    @margarita8442 Před 3 měsíci

    massive system

  • @awbean5254
    @awbean5254 Před 3 měsíci +2

    SCOTT, YOU & YOUR TEAM DO GREAT WORK! [as you stated trough wire management is a bit challenging]
    THANK YOU AGAIN FOR SHARING YOUR AWESOME PROJECTS! WE LOOK 👀 FORWARD TO THEM! 👍 👍

  • @TheRedneckprepper
    @TheRedneckprepper Před 3 měsíci +3

    Man that much stored power Ied put a Halon System in !

  • @Ted_E_Bear
    @Ted_E_Bear Před 3 měsíci +2

    Beautiful work ! Are these Solar Panels safe in a heavy hail storm?

  • @ScheldonR
    @ScheldonR Před 3 měsíci

    That's one sexy installation

  • @defjamsgreen
    @defjamsgreen Před 3 měsíci +1

    INCREDIBLE SOLAR INSTALLATION !🤗MAY THE SOLAR BE WITH YOU .

  • @solarforfuture
    @solarforfuture Před 3 měsíci +1

    Beast mode! i only have one battery... wow..

  • @daniellinville4637
    @daniellinville4637 Před 3 měsíci +1

    Be nice to get that one

  • @dogandhisboomer
    @dogandhisboomer Před 3 měsíci

    What type of surge protection do you use if any and do you put at the Sol-Ark and Array ?

    • @engineer775
      @engineer775  Před 3 měsíci +1

      It is an EMP hardened system. That is the only protection installed.

  • @ALink2Zelda
    @ALink2Zelda Před 3 měsíci +2

    yolo hope everyone is doing great

  • @markp9083
    @markp9083 Před 3 měsíci

    as others have suggested I would put bollards inside and on the external wall seems like everything on a farm will get backed into at some point.

  • @OG_Gamers_Live
    @OG_Gamers_Live Před 3 měsíci

    Do wish I had the means to do something like this on my two lots next door.

  • @robertsteich7362
    @robertsteich7362 Před 3 měsíci +1

    I would fabricate a protection bar/face for that rack. Especially since it’s in an open garage rather than a mechanical room.

  • @fadhilally-bb8oo
    @fadhilally-bb8oo Před 3 měsíci

    Proud of it, I like to be some of your Team😅

  • @Wasthatreal76
    @Wasthatreal76 Před 3 měsíci +1

    I like the way David Pozs makes videos.

  • @johnmiggins9431
    @johnmiggins9431 Před 3 měsíci

    nice as usual, question does the micro air also help in surges when system is on or heat strips? two separate quesitons. I know it helps with start up surge, for heat pump that is not that bad but it also surges when heat strips come on. They may be more of a constant load but is there a surge when they come on too? thanks

  • @mfaulk6526
    @mfaulk6526 Před 3 měsíci

    Thanks for what you do. I have a battery question. In your opinion which is the better purchase, Pytes or HomeGrid? Connecting to SolArk 15.

  • @maverickmacgyver
    @maverickmacgyver Před 3 měsíci

    “Moment truth… little glitch… “. I’m glad not all the smoke came out something… 😳🤓😂

  • @simonpaine2347
    @simonpaine2347 Před 3 měsíci +1

    Being as though the Sol-Arks ask for 2 battery connections on each input, I wonder with the amount of power flowing through the battery cables, whether it would be better to run 6 positives and 6 negatives from the busbars to the inverters. After all Sol-Ark presumably put a double input there for a reason?

  • @mattbrew11
    @mattbrew11 Před 3 měsíci +1

    What the peak output of this system and time to fill batteries from empty with no load?

  • @whitlockbr
    @whitlockbr Před 3 měsíci

    Do you all install heat pumps, heat energy storage, wind, or hydro power? Once those batteries are full and all the loads are satisfied what happens to excess energy?

  • @estesfamily6761
    @estesfamily6761 Před 3 měsíci +1

    Looks good but perhaps it would be prudent to cleanup and label the wires in the trough. Just a suggestion from someone with mild OCD. Appreciate your videos!

  • @greengooseman
    @greengooseman Před 3 měsíci

    What is a good ratio for set up like this?
    I see your battery bank to inverter size is about 5 to 1.
    Did you say how many panels @ what wattage?
    What daily use did you use to come up with this size system?

  • @raptormatt21
    @raptormatt21 Před 3 měsíci

    Looks beautiful, and those DC busbars look sweet! Who makes them?

    • @nathanphay
      @nathanphay Před 3 měsíci

      Those look like Blue Sea 1000A bus bars.

  • @StevenC1961
    @StevenC1961 Před 3 měsíci +3

    It’s time to move to 30k Sol Ark with high voltage batteries, way to much wire cost

  • @samgillis6224
    @samgillis6224 Před 3 měsíci

    I know how great the Solark is, but do you ever use low frequency based inverters in your builds? Would they not be better/more durable for high surge loads like those AC units?

  • @Tugedhel
    @Tugedhel Před 3 měsíci +1

    Is that guy going to build battery racks for you as clients want them?

  • @MisterPikol
    @MisterPikol Před 3 měsíci

    that's some MASSIVE storage amount hoooly

  • @RhacsandMTG
    @RhacsandMTG Před 3 měsíci

    Nice install, how much it cost them?

  • @richardoder3459
    @richardoder3459 Před 29 dny

    I would be interested in knowing the charging difference from the top battery and the bottom battery since they are not connected to a bus bar along the side with short cables.

  • @niktak1114
    @niktak1114 Před 3 měsíci

    Very similar usable capacity to the Silverado EV (214kWh)

  • @MrAlejandro787
    @MrAlejandro787 Před 3 měsíci

    Hi keep loading videos , got questions last week took training with Pytes over here Puerto Rico then say only three batteries together bus bar only hold 300amp

  • @HarryL2020
    @HarryL2020 Před 3 měsíci

    LiFe batteries have come down in price so much it's insane, actually very affordable to go off-grid these days considering the insane energy prices (UK)

  • @VidarTeiseniHeisen
    @VidarTeiseniHeisen Před 3 měsíci

    I didn’t see any hrc fuses, isn’t that needed? What is this banks short circuit current? And won’t the batteries in each end of the racks get more cycles when they’re not balanced 100%?

  • @Subgunman
    @Subgunman Před 3 měsíci

    Are those microstart units available for use on European 230 volt 50 Hz systems?
    Does this customer think of fabricating and selling these racks? They are not cheap BUT well worth the money if they do a good job for those rack mount batteries.

  • @Foxfried
    @Foxfried Před 3 měsíci +2

    How is this allowed? the UL Rules say max 20KW / unit and then it must have a 12' space also max 50 KW in a house. I just wanted to know.

  • @h2opower
    @h2opower Před 3 měsíci

    You should have placed them a lot higher above the ground so that the ground underneath can have other uses for the owner other than just sitting there doing nothing. Think of those parking type setups where the panels are above the cars and trucks making that land have more than one use for the owner of the land.

  • @NewLightEnergy
    @NewLightEnergy Před 3 měsíci

    The USA rules. We are only allowed max 80kw battery in Canada. I run 45 kw which is awesome, wouldn’t mind another 15kw.

  • @dbird29
    @dbird29 Před 3 měsíci +2

    Any fire suppression for the battery racks?

    • @freighter1097
      @freighter1097 Před 3 měsíci

      Most people don't have fire suppression in their home.

  • @robertmatthews4285
    @robertmatthews4285 Před 3 měsíci

    At 13:33 are those donuts noise cancellation magnets? What drives the need for them. Don’t recall seeing them before on other installations.

    • @onthelake9554
      @onthelake9554 Před 3 měsíci

      Part of the EMP hardening . Ferrite cores .

  • @SkypowerwithKarl
    @SkypowerwithKarl Před 3 měsíci +3

    I didn’t notice a main DC disconnect or any fuses. Yes each battery has a current limiter, but the overall combined current output is massive. Could probably vaporize 4/0. Perhaps a T class fast blow fuse between each vertical sever row and the buss. From the buss to main DC disconnect then a T class fast blow to each inverter. Maybe not necessary for code in your area, but it would make me feel better if it was mine.
    Yeah I know a UL DC disconnect costs as much as an inverter but some DEHOOL makes breakers rated up to 630 amps and 1500 Volts DC for under 250$ (Amazon) could easily be fitted into the wire way. I have used these breakers and they are very well made, but take care not too over torque the terminals. When you manually operate the breaker it makes a clunk that’ll wake the dead.

    • @antronx7
      @antronx7 Před 3 měsíci

      Combined DC disconnect is unnecessary. Each battery has 100A electronic "disconnect". Each inverter has it's own DC breaker.

    • @SkypowerwithKarl
      @SkypowerwithKarl Před 3 měsíci

      @@antronx7
      I don’t think you understand. Each battery IS rated at 100 amps continuous AND 180 amps for 15 seconds, probably a lot more inrush for shorter periods. The bms is not user configurable so the current can’t be individually reduced for a lower overall. That means 42 rack batteries times 180 amps = 7560 amps for 15 second. There looks to be three 4/0 cables so each one would attempt to carry 2520 amps, however thou that would be a possible but unlikely scenario, it would probably be a more exciting as only one 4/0 would potentially be shorted. Probably just blow the crap out of anything that accidentally gets in the way or turn the 4/0 into a smoky glow worm joining with everything in contact. Most inverters have the chassis ground bonded with battery negative to what extent is unknown. The vertical short conduits between inverter and wire way plus the inconsequential little bonding ground means that the wire way is also by de facto not just grounded but also NEGATIVE.
      So you see my concern if someone got a wrench in the works so to speak?

    • @antronx7
      @antronx7 Před 3 měsíci

      @@SkypowerwithKarl BMS trips in under 1ms when current is > 250A. That's 10kA * 50V * 0.001s = 0.14 watt/hours of energy induced into a fault. It will make a spark and that's it. It will not even trip a mechanical breaker rated for 1kA. BMS will trip first.

    • @SkypowerwithKarl
      @SkypowerwithKarl Před 3 měsíci

      @@antronx7
      Now times that by 42 rack batteries

    • @antronx7
      @antronx7 Před 3 měsíci

      @@SkypowerwithKarl nope that already includes 42 batts. 250a*42=10.5kA.

  • @smacfe
    @smacfe Před 11 dny

    This is pure off grid with generator back up. How would a hybrid system be different where the grid was also used as a secondary backup on a system this size?

  • @theps3fanzz
    @theps3fanzz Před 3 měsíci

    What kind of waistline phone holder is he using at 10:26?

  • @EngOne
    @EngOne Před měsícem

    How much does a system like this cost ??

  • @Tezza66
    @Tezza66 Před 2 měsíci

    Amplifier racks as used in audio industries. Look int those

  • @xzibit8614
    @xzibit8614 Před 3 měsíci

    I would have replaced that packaged unit’s aging capacitor

  • @TheWolfster001
    @TheWolfster001 Před 3 měsíci

    With that much power, wouldn't it be better to sell the excess power back to the grid..
    I seen a video, about a year ago. They spent over 1 million dollars, had a few array's that were all solar tracking, all the panels were top of the line, there was 3 houses a pole barn and a machine shop was powering, they were connected to the grid only to sell unused back, they estimated they would, in a couple years make upwards of $1,000.00 a month in revenue..
    Is that really possible, to make money on selling excess power..
    Loved watching.. Thank you for sharing...

  • @yourpcmd
    @yourpcmd Před 2 měsíci

    When the solar costs more than the house!

  • @klaatu2
    @klaatu2 Před 3 měsíci

    I put the batteries in a separate structure, one I can afford to lose to fire and distant enough not to spread to other structures. Even if they are Iron Phosphate, if and when they fail, they produce tremendous amounts of Hydrogen gas...think Hindenburg. You can mitigate this with a clear path for the hydrogen to escape upwards, as opposed to a confined sealed space

  • @FullSpectrumWarrior
    @FullSpectrumWarrior Před 2 měsíci

    Here I thought my planned 92kwh battery install was big

  • @mwilhelmpa
    @mwilhelmpa Před 3 měsíci +1

    Beautiful installations but Pytes flexible Busbar are rated 300 Amps and you are connecting 12 x100Amp V5 in parallel.

    • @antronx7
      @antronx7 Před 3 měsíci

      Inverter will not pull more than 300A continuously so each outermost busbar will be within max rating.

    • @mwilhelmpa
      @mwilhelmpa Před 3 měsíci

      @@antronx7 1 Inverter Yes, but I see 3 in parallel 900 Amp then

    • @antronx7
      @antronx7 Před 3 měsíci

      @@mwilhelmpa you also see 3 battery stacks in parallel giving you 900A total and

  • @ronwatkins5775
    @ronwatkins5775 Před 3 měsíci

    Im running a 1MW facility off the grid currently. We have been discussing Solar as an option for some of that consumption. The issue we face is that Solar is roughly 8 hours/day, and we would only decrease our grid usage during the daylight hours. Im wondering what a batter solution might look like which could handle some of our capacity during a 24-hour window.

    • @isovideo7497
      @isovideo7497 Před 3 měsíci

      1 MW continuous? 24MWh each day! 16MWh overnight in Winter. 5KWh per typical LFP battery, so 3200 batteries needed. At say $1400 each, that's $4,280,000 in batteries, though you may get a quantity discount ;^) Or maybe four Tesla Megapacks (3.9MWh each)?

    • @ronwatkins5775
      @ronwatkins5775 Před 3 měsíci

      @@isovideo7497 Yes, incremental is the best approach. Im not convinced about batteries though. They are a consumable, so need to be replaced periodically. They have a cycle life, which is limited. So that factors into the cost of the electric over time.

  • @curacao11
    @curacao11 Před 3 měsíci

    😎

  • @UK-Expat-in-USA
    @UK-Expat-in-USA Před 3 měsíci

    Curious why you use individual Inverters and do not use Enphase Mini Inverters, for more redundancy, is it because you want to stay with DC to charge the batteries and not have the loss of converting from AC to DC?

  • @gncl7599
    @gncl7599 Před 3 měsíci +1

    I would have made the first bottom row of the racks just a bit higher.

  • @geli-wq1sb
    @geli-wq1sb Před 3 měsíci

    是否有电池需求可以提供电池等设备

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity Před 3 měsíci

    8:45 it’s not wired any different than most other 1ph 230VAC PSC compressors. The contactor “R” terminal is the same as “C” terminal on the dual run cap. Some manufacturers run the run winding “R” from the compressor back to the contactor “R” and some take it back to the “C” terminal on the dual run capacitor. It’s standard wiring practice in the HVAC industry.

    • @engineer775
      @engineer775  Před 3 měsíci

      It actually is. There are a lot of variations. Yes, generally they're all the same but they are not wired the same. That is why when you install a micro Air you have to pull the wiring diagram. Not all manufacturers wire their systems the same even though they work the same.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Před 3 měsíci

      @@engineer775for us pro hvac guys, it should be basic wiring knowledge.

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity Před 3 měsíci

    Total 49kWp, 240kWh diy LFP. Yeah, you did a big one.

  • @gregorythomas333
    @gregorythomas333 Před 3 měsíci

    Porsche systems & Toyota systems?
    Dude...I'm working on a Yugo budget!

  • @sickwhip
    @sickwhip Před 3 měsíci

    Sick. Just Sick.

  • @Sylvan_dB
    @Sylvan_dB Před 3 měsíci +1

    Still 48v nominal on the battery? Seems like a system this size is begging for a much higher D.C. bus.

  • @carlossousa3285
    @carlossousa3285 Před 3 měsíci

    when money is no issue... Impressive, with nothing else to say ;-)

  • @jkuoverland8507
    @jkuoverland8507 Před 3 měsíci +1

    You can’t hide money!