    Join Cory as he carries out an EICR on an absolute disaster of an electrical installation...
    Watch Part 2 here: • Shocking Electrical Wo...
    Subscribe to our CZcams Channel for more great electrical content: czcams.com/users/artisanelectr...
    🔔 Join This Channel To Get Access To Perks 👇
    ➤ / @artisanelectrics
    🧰🛠️ Tool Of The Day 👇
    Klein 27 in 1 Ratchet Screwdriver: amzn.to/3s3nZ2Y
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    -----Electricians Business Course-----
    📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
    ➤ course.electriciansbusinessco...
    🔔 Subscribe to TOOLS4SPARKS CZcams Channel 👇
    I Also Have A Dedicated CZcams Channel About Tools:
    ➤ / tools4sparks
    -----TESLA REFERRAL CODE-----
    🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
    ➤ ts.la/andrew24855
    -----MY ENERGY PROVIDER-----
    🐙 Get £50 credit when you switch to Octopus Energy 👇
    ➤ share.octopus.energy/zappy-sh...
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    ADVERTS THAT SUPPORT THE CHANNEL:
    Thanks for your support!
    This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
    #shockingelectrics #electricianlife #artisanelectrics
  • Věda a technologie

Komentáře • 546

  • @artisanelectrics
    @artisanelectrics  Před 3 lety +11

    Watch Part 2 here: czcams.com/video/Rm9Zbdypkbg/video.html

  • @iancarbin567
    @iancarbin567 Před 3 lety +98

    Cory, you should send photos to the college where this so called sparky will lecture. No way should he be allowed anywhere near an apprentice. It’s borderline criminal!!

  • @zakirbahadur6218
    @zakirbahadur6218 Před 3 lety +82

    Cory lives a very sheltered life, this is actually very good compared to some of the stuff ive seen. Just last week I went to building site with some romanians staying on site, they had a 8.5kW electric shower running off some 1.5mm 3 core flex powered through a 13A plug. I look at it and think, 'how has that not blown the fuse'. Opened the plug and found a PZ2 drill bit wedged in place of the fuse and that was the safest part of the installation.

    • @ollieclark
      @ollieclark Před rokem +13

      Sounds like my old school. The hand driers kept blowing their fuses so the caretaker put pieces of 6" nails in them instead. The covers had been lost and you could see the nails heating up.

    • @MarkUKInsects
      @MarkUKInsects Před rokem +4

      Goes with my experience to. Generally this would be called DIY. But I mostly see the best and worst with "professionals". and on average, Diy is in the middle ground.
      and PS I have seen much worse that that, that was by multiple professionals.

    • @tam2083
      @tam2083 Před rokem +1

      Drama queen

    • @fabianmckenna8197
      @fabianmckenna8197 Před 9 měsíci +1

      Wow! To think I was worried about using an 8.5kw shower on 6mm......
      Finally gave in and got gas central heating with a awesome shower.

    • @flimflama9333
      @flimflama9333 Před 9 měsíci

      ​@fabianmckenna8197 6mm is powerlines where I'm from

  • @rossthompson1635
    @rossthompson1635 Před 3 lety +117

    I've said it before but Cory, your presentation style is excellent - engaging, fluent and nice gentle quirky humour.

  • @davidclark3603
    @davidclark3603 Před 2 lety +6

    I'm retired now,I used to do this inspection and testing 80% of the time, I hated it! I did a big massive university village that took 18 months to do! 1000s circuits and faults on every one. Maintained by city council, Mr. Blunders. And I was the one always in trouble? "You switched off the power", they would say. "My computer went off"! Everything held together with pvc tape and connectors. It cost £millions and £millions to re-wire the lot all for nothing. I passed through Manchester and stopped in disbelief. The whole site has been demolished to make way for a new hospital. I still have dreams nowadays of the Elizabeth Gaskell site! Great video, and good luck with your work.

    • @jeffpark4136
      @jeffpark4136 Před 20 dny

      worst thing about EICR's for me is that it becomes a thing where you're just going back on someone elses fuck ups. that pretty much all I would seem to find on most of the jobs.

  • @chrisjacquier8003
    @chrisjacquier8003 Před 3 lety +21

    As an MIET and Chartered Electrical Engineer myself, I can fully sympathise with your views of that mess. The house owner should sue the fool that did the earlier mess and should either get a qualification in knitting or electrical installation, if he has any aptitude for either, which appears doubtful.
    As for lecturing electrical installation, one can only hope he's going to have no success and is forced to leave. Better still, if you know him, its your duty to name him to the IET and the college backed up with photographs and a statement about his identity from the house owner.
    Basically, he should be prosecuted and all his work remedies before it causes fire or electrocution.

    • @nicotoscani1707
      @nicotoscani1707 Před rokem +1

      yes, they should all be prosecuted for botch jobs.. should be across theboard..any trader needs prosecuting for shoddy work.. they are hidingbehindd accreditation and fooling ppl into believing they're competent...sad

  • @lockingthroughlife2587
    @lockingthroughlife2587 Před 3 lety +66

    “I’m too pretty for jail” absolutely hilarious. Cory is such a comedian and so entertaining in these videos. Great work fella 👍

    • @johnavery15
      @johnavery15 Před 3 lety +3

      My favourite line of the video. Cory must be such good fun to work with.

    • @oicfas4523
      @oicfas4523 Před 10 měsíci

      So true too 😊.

  • @JasonShowell
    @JasonShowell Před 3 lety +82

    This guy has improved the channel no end. Useful information without all that 'Better than you' opinion from before.

    • @jacktwohig2135
      @jacktwohig2135 Před 2 lety +2

      This comment doesn’t make sense

    • @JasonShowell
      @JasonShowell Před 2 lety +9

      @@jacktwohig2135 what don't you understand? Cody is what the channel needs. Jordan doesn't connect with Joe public.

    • @Lewdacris916
      @Lewdacris916 Před 2 lety +4

      @@JasonShowell Agreed the other guy seems like a snob, I don't like his demeanor

    • @kryptoniteee
      @kryptoniteee Před 2 lety +10

      Jordan’s the kind of guy you want to wire your house but you wouldn’t want to spend anytime with him. Cody is chill.

    • @artisanelectrics
      @artisanelectrics  Před 2 lety +5

      @@kryptoniteee 🤣🤣🤣

  • @jacka5994
    @jacka5994 Před 3 lety +34

    “Looks like Bob Marley rolled that joint” tho 😂😂😂

  • @CilusseYT
    @CilusseYT Před 3 lety +51

    Cory: "I have a feeling it's gonna be a nightmare"
    Me: *looks at the title*, *looks at the video length*, "Part 1"
    Me: "Oooh yes it will be"

    • @artisanelectrics
      @artisanelectrics  Před 3 lety +8

      HAHA

    • @CurtainFlapper
      @CurtainFlapper Před 3 lety +3

      Can't wait for part 2. Why bodge a job like this with all the cabling under the units. If it can't be done correctly as to code then don't take the job on in the first place. It looks like a kitchen fitter has taken on the job doing the whole fitting of electrics and cupboards.

    • @Sam.147
      @Sam.147 Před 3 lety +3

      Why not just unscrew the cabinet and pull it out to give you full access to the board??

    • @Sam.147
      @Sam.147 Před 3 lety +1

      Great content btw Cory! It's only a matter of time before you have your own channel on here 💪💪

  • @roymorton8142
    @roymorton8142 Před 3 lety +25

    That is diabolical. I’ve never seen worse. Don’t know how you remained so calm, I’d have cracked up!!

  • @chrisrogers2848
    @chrisrogers2848 Před 3 lety +22

    Cory is such a professional. Great to see his pride in his work 👍

  • @Dazy73
    @Dazy73 Před 3 lety +22

    Bob Marley rolled that joint 🤣🤣🤣🤣

  • @ColinRichardson
    @ColinRichardson Před 3 lety +27

    Mr. Bodge needs to be named and shamed.. no, not shamed... told to make right what he has made wrong.

    • @elminster8149
      @elminster8149 Před 3 lety +3

      Feels a bit too cancel culture to me, but I would send photos to his new boss on the QT.

  • @markgilder9990
    @markgilder9990 Před 3 lety +16

    It’s disheartening for customers, they pay a for a “Proper” electrician only to find out that it was a total waste of money. Or done on the cheap only to be bitten further down the line.
    I attended a customer for a fault, kitchen had only been in 3 months, Carpenter charged £600 to rewire kitchen and told the customer he had an electrician in turned out he did the wiring himself. Had to have the kitchen taken out to rewire the whole lot. We need laws like they have in Australia covering electrical work.

    • @jennytillz
      @jennytillz Před 3 lety +2

      Even with the laws we have here in Australia there are still plenty of cowboys getting about. I have come across some absolutely appalling electrical work in my 20 years in the trade.

    • @steverobinson8170
      @steverobinson8170 Před 3 lety +2

      Laws never stop incompetence , we are already highly regulated , i for instance can't work on historical buildings any more because its not on my card (although i hold qualifications that say and prove otherwise but the new regulation systems have decided they won't recognise them ). They forget those with the knowledge , skills and experience often trained under a different regime where college and formal paperwork never really mattered . My main trade is carpentry and joinery , Electrical work was a secondary trade i learned later in life , at 61 now i have no intention of formalising my training done 30 plus years ago.

  • @janehoward509
    @janehoward509 Před 3 lety +3

    Fabulous work boys. Great camera work Jordan. Very smooth and easy to watch

  • @owenlumley6778
    @owenlumley6778 Před 3 lety +20

    If my college tutors are anything to go by, they get into teaching because they can't handle the graft, and this appalling standard of work comes as no surprise.

    • @MarkUKInsects
      @MarkUKInsects Před rokem +1

      My last degree was software engineering, some time ago now. But why would you be a tutor in about 27K when as a software engineer you can earn 3 times that? To be fair, most where brilliant, and just want a few quieter years after a successful carrier, before they retired. But a few where utterly useless, and clearly were in teaching because they couldn't do the day job.
      This is the real issue with vocational training in the UK. Tutors are mostly paid all the same. so a few years ago, if the wanting to teach catering or beauty, then 27k was a far salary. But for IT, Electrical, plumbing etc. who would give up a well paid job to teach?

  • @rabsil100
    @rabsil100 Před 3 lety +4

    Great to see good Sparks still on T&I/Regs!

  • @johnconaboy9461
    @johnconaboy9461 Před 3 lety +22

    No Electrician worth his salt would complete an installation like that, don't believe the blokes qualified at all, Check that man's qualifications he never studied a day in his life, How old I wonder is this clown 🤡

  • @JIBS.
    @JIBS. Před 3 lety +3

    This is why this is the best electrical channel by far. This Cody fella is brilliant.

  • @davidtimperley4241
    @davidtimperley4241 Před 3 lety +10

    The problem with this sort of appalling workmanship is even when you've tested everything in sight you still might not find doggy hidden joints under floors etc. And it begs the question "for the clients safety is now the time to rewire the whole of the property" ?

  • @OBWanKenobi
    @OBWanKenobi Před 3 lety +11

    there will be joints in walls and under floors and all over the place, i would check all cable colours at lighting and socket points

  • @tahseenashfaq
    @tahseenashfaq Před 3 lety +2

    Another great video by Corrie, so interesting and funny too 👍🏼

  • @intercity125
    @intercity125 Před 3 lety +1

    Got a 3 phase incomer here at home too - on what was a looped service. Caused much shambles when the (single phase) meter was changed to the digital sort years ago (first two installers apparently only had single phase training)

  • @markusvanryan7394
    @markusvanryan7394 Před rokem

    This guy Cory is fantastic his presentation skills and explanation is a wonderfully good.

  • @sheargillsparkie9588
    @sheargillsparkie9588 Před 3 lety +7

    This is precisely why we do an eicr first before any work like a consumer board change. Cory, I applaud you for taking us through what a good portion of us find as part of our daily routine. I use these examples to show young apprentices how Not To!!
    You were actually predicting each stage as I’d guess you’ve probably seen done before, by a none qualified spark.
    I found this intriguing but also had a sense of de ja vu....
    Great video.

  • @meuk6929
    @meuk6929 Před 3 lety +5

    Ive had a bad day on site today and after watching this, Todays not actually been that bad!!! HAHAHAHA!!!

  • @carlrobson5745
    @carlrobson5745 Před 3 lety +13

    Spider senses tingling were right on this one.

  • @ru8y1987
    @ru8y1987 Před 3 lety +2

    You can get those Enlite downlights with the click connectors on them already from some wholesalers (well used to be able to anyway)

  • @ronaldomac4918
    @ronaldomac4918 Před 3 lety +1

    Great video with some nice snippets of knowledge along the way.....! :)

  • @marktubeie07
    @marktubeie07 Před 3 lety +3

    Release the kraken - name the lecturer...! Yes, length of video = proportion of 'nightmare'! Corey, you are hysterical man :)

  • @ColinRichardson
    @ColinRichardson Před 3 lety +3

    21:49 Pointing out the 3 phase..
    I spotted that earlier when he was talking about the covers are loose..
    I was wondering if it was 3 phase, but I have zero expertise. Just CZcams videos...
    I given myself a mini pat on the back for working that out myself. (I say working it out, more questing it myself)
    I was so pleased when he pointed it out though..

    • @artisanelectrics
      @artisanelectrics  Před 3 lety

      Well done!

    • @PeterPetersNL
      @PeterPetersNL Před 3 lety +1

      We have 3 phase down the block and into the house. But then each house has only one phase in use. First house, first phase and so on. That spreads the loads over all three phases. But when you want 3 phases you can get it without much costs.

    • @ColinRichardson
      @ColinRichardson Před 3 lety

      @@PeterPetersNL I don't even know where the tails are in my house. My Consumer unit is a floating box on the wall, nothing visible in or out..
      I never really paid attention in my last house, it wasn't an interest at the time. And my parents house.... MY GOD... I don't even know how to describe how old the electrics are..
      I've never even seen the shape of their consumer unit on any video for a comparison..
      When they said "Oh, we will see an old board" .. and they showed ^ that board.. I was very disappointed. It wasn't old enough to identify what my parents have. It still looked modern in comparison.
      Though, next time I am around their house (Most likely Tuesday evening to make sure they have everything they need), I might see if I can see if they have a 3 phase tails thing like Mr Bodge had..

  • @mathman0101
    @mathman0101 Před 3 lety +2

    What a horrendous find. EICR only way forward to get the full extent of the problems. Problem is with all the finds you saw do you leave it in the way you found it ie do the tape up on those horrible splices in the kitchen? Is there a minimum rule for safety to have to employ even though you were not involved in that installation to leave it safe for the client.
    Glad you did not run away from this. Situations like this is where real sparkies are made. It does not have to be pretty if your not doing a full rewire. Making it safe and upto standard is the first order of the day. Looking forward to the next video.
    Real world sparking....... well done Artisan and Cory.

    • @markgilder9990
      @markgilder9990 Před 3 lety

      C1 Dangerous make safe. Even if it means disconnecting the circuit.

  • @demonkey123
    @demonkey123 Před 3 lety +1

    Interesting video, thanks! Beware oven ratings from early 2000’s some were ridiculously high using elements sourced from a commercial environment. a fifty amp supply seems high, but check that data tag to confirm. CPC-circuit protective conductor (sorry ocd)

  • @johnfenlon458
    @johnfenlon458 Před 3 lety +1

    Wow Oh my god. it was really mixed up wiring someone didn't do a job. I’ve never seen worse. I think the low cabinet box should take off. Great job Cory found it. Let do it video Part 2 I will watch it. Thumb up!! Cheer!

  • @Darkassassin09
    @Darkassassin09 Před 3 lety +6

    32:00 I bet the lights came with the little flex+connectors pre installed, just had to wire the feed connector.

  • @shaungrain4921
    @shaungrain4921 Před 3 lety +1

    thanks the info from note 3 has been very useful more please

  • @rscelectrical7091
    @rscelectrical7091 Před 3 lety +2

    This guy is teaching others, that's totally bloody scary. Keep up the good work mate, really enjoying your content and commentary style. One suggestion though mate: Buy some overshoes, I wouldn't be wandering around anyone's house without boots on. I did it once and ended up at hospital with a piece of glass in my foot, never again.

  • @nickrundall
    @nickrundall Před 3 lety +1

    God damn Cory, you are so watchable. Rock on dude.

  • @Paterson31
    @Paterson31 Před 2 lety

    This makes me think I may need an audit on the electrics in my house. Loving the channel. Came across the channel when looking what I need to do to get an EV charger in place. May call you guys

  • @Mike-st5et
    @Mike-st5et Před 3 lety +1

    It's one of your best videos yet

  • @stuartjohnston1086
    @stuartjohnston1086 Před 3 lety +24

    I don't see a problem with him retiring from the job to become a college lecturer. Perhaps he's a good chef and can teach cookery...

    • @oyleyhands1332
      @oyleyhands1332 Před 3 lety +5

      Basket weaving would suit the guy...

    • @shrubbie1
      @shrubbie1 Před 3 lety +3

      As long as he doesn't wire up the cooker...

    • @chrissyboy123456789
      @chrissyboy123456789 Před 3 lety +4

      Toublle is mate as a past properly trained chef too many clowns decide to "become a chef " and have no clue about food but above all that food safety is a hidden killer much like electricity.

    • @rabsil100
      @rabsil100 Před 3 lety

      Butcher! I was thinking, friend. lol

    • @rabsil100
      @rabsil100 Před 3 lety

      @@chrissyboy123456789 Chef Bosses the Kitchen, during Routine Maintenance, friend. no disrespect to fellow tradesmen intended I'm sure mate.

  • @xxxyyy9544
    @xxxyyy9544 Před 3 lety +9

    Had a friend who was on the same testing/inspection course as me who years later became a college tutor. His work was always to regs and tidy, but he was very slow. Being an ex-army engineer, he took no crap from anyone, lost his temper with some rude toe rag teenager and pinned him against a wall. Lost the job.

  • @havoctrousers
    @havoctrousers Před 3 lety +1

    Unusual place, 3 phase cutout. Loving that inaccessible, coverless garage unit behind the cupboard! I swear someone must have put that in to spite the next spark.

  • @dansmith436
    @dansmith436 Před 3 lety +4

    38:37 had me hurting 🤣

  • @chrissyboy123456789
    @chrissyboy123456789 Před 3 lety +9

    Im not an electrician and love the videos of all you professionals -- the work you checked was shameful. I have routed in cable etc in my home and ready for final check and connection to any new circuits and take so much time in reseach and then care and trouble to make it look good and workmanlike (much as you chaps) Also totally OTT with quality materials and then all accessible, tagged and labled. How the heck that clown as a "proffessional" is now teaching in a college is beyond me, no wonder he gave up in business.God help his students.

  • @brightside0970
    @brightside0970 Před 3 lety +14

    This is an everyday occurrence only time you don’t see it, is when you’ve done the work yourself

    • @rabsil100
      @rabsil100 Před 3 lety +1

      Following "A mate done It, cheap like" friend, seen too many.

  • @billdoodson4232
    @billdoodson4232 Před 3 lety +46

    Haa haaa! Quote of the year so far. "I'm too pretty for jail"

  • @peterclark5242
    @peterclark5242 Před 3 lety +24

    This bloke is now college lecturer what a joke!! Let's start praying for those poor apprentices

    • @gordsec
      @gordsec Před 3 lety +5

      That defo needs to be reported. Its bad that a time served sparky did it (and charge good money for it), but for that person to now teach is ridiculous, as his shoddy practices may be the foundation for apprentices who will continue his bad practises. There are a lot of people who don’t understand what constitutes good workmanship and will happily pay for work to be undertaken due to reputation. If the work can be attributed to him, he should be reported to the NICEIC and to his new employer.

    • @drsquirrel00
      @drsquirrel00 Před 3 lety

      Was this their own house? Maybe case of shoemakers children?

  • @jonathanowens7252
    @jonathanowens7252 Před 3 lety +2

    Bloody hell, I'm not even a spark and those cable joints scared me. I've always been wary of electricity since I broke one of the old "kettle" leads accidentally and got a belt when my hand bridged live to neutral at 240v.

  • @jonty2020
    @jonty2020 Před 3 lety +5

    Shocking... Literally!

  • @andyhill242
    @andyhill242 Před 3 lety +13

    Pardon the pun but that installation is absolutely shocking!
    Yes, you should release the name of the culprit to the college and whatever organisation governs electricians.

  •  Před 3 lety +5

    Press 'F' to pay respect. Btw the 'Cory's Classroom' segment was very good. 25:13

    • @kyester123
      @kyester123 Před 3 lety


      ⠀⠀⢀⡤⢶⣶⣶⡄⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀ ⠀⠀⢀⣠⣤⣤⣤⣿⣧⣀⣀⣀⣀⣀⣀⣀⣀⣤⡄⠀ ⢠⣾⡟⠋⠁⠀⠀⣸⠇⠈⣿⣿⡟⠉⠉⠉⠙⠻⣿⡀ ⢺⣿⡀⠀⠀⢀⡴⠋⠀⠀⣿⣿⡇⠀⠀⠀⠀⠀⠙⠇ ⠈⠛⠿⠶⠚⠋⣀⣤⣤⣤⣿⣿⣇⣀⣀⣴⡆⠀⠀⠀ ⠀⠀⠀⠀⠠⡞⠋⠀⠀⠀⣿⣿⡏⠉⠛⠻⣿⡀⠀⠀ ⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⣿⣿⡇⠀⠀⠀⠈⠁⠀⠀ ⠀⠀⣠⣶⣶⣶⣶⡄⠀⠀⣿⣿⡇⠀⠀⠀⠀⠀⠀⠀ ⠀⢰⣿⠟⠉⠙⢿⡟⠀⠀⣿⣿⡇⠀⠀⠀⠀⠀⠀⠀ ⠀⢸⡟⠀⠀⠀⠘⠀⠀⠀⣿⣿⠃⠀⠀⠀⠀⠀⠀⠀ ⠀⠈⢿⡄⠀⠀⠀⠀⠀⣼⣿⠏⠀⠀⠀⠀⠀⠀⠀⠀ ⠀⠀⠀⠙⠷⠶⠶⠶⠿⠟⠉⠀⠀⠀⠀⠀⠀⠀⠀

  • @sweet30adam
    @sweet30adam Před 11 měsíci

    Hi Cory I appreciatie you in this great work . I,m also Electrician work was but i was never had like these

  • @goodlookinouthomie1757

    Love the explanations. Like taking a lesson.

  • @jackl9922
    @jackl9922 Před 3 lety +2

    Wow. I was curious to find out what ‘ring circuits’ are. Sounds scary to me. I do like you use higher voltage. Here high currents even with bigger copper can have issues with poor connections. I’m always careful on termination as 120v with high wattage, current can be high.

  • @samuelgilbert9734
    @samuelgilbert9734 Před 8 měsíci

    33:41 In Canada, there is no sleeve on the grounding conductors. From what I can see, the CPC is connected to any exposed metal just as we would do over here. Why is it the reasoning behind requiring a sleeve on the CPC in the UK?

  • @SproutyPottedPlant
    @SproutyPottedPlant Před 3 lety +5

    Awesome video and ♥️Cory ! I'm not an electrician but enjoy the videos. What is the PCB in the box? For low voltage garden lights??

    • @JamesScholesUK
      @JamesScholesUK Před 3 lety +2

      It's a Wisebox. Off the shelf radio controlled circuits. Tend to get used for garden lights and water features, but you can use them for anything. Standard kit gives you 4x 5A circuits and a keyfob remote

  • @raymondgarafano8604
    @raymondgarafano8604 Před 2 lety

    I knew about M-11 from Rumpole of the Bailey, played by Leo McKern. I had jobs I refused
    as the job would take way too much time and aggravation. As I heard it, fuse wire is used
    in service panels down under or in Australia. . . .

  • @drake19891
    @drake19891 Před rokem

    Also seen alot of proximity testers indicate power when a switchboard is all off and solar panels haven't been isolated.

  • @elco_os9355
    @elco_os9355 Před 3 lety +1

    I really like to watch these kind of videos. I have seen an installation that was modified by university students of electrical engineering. Those guys only learn things from a theoritical point of view and don't know anything about regulations and practical stuff. The installation was a complete disaster. Green/yellow earth wire was used for everything, except earth. And there was a junction box containing solid wires which were soldered to glass fuse holders mounted on a DIY wooden frame..

  • @ianlove3
    @ianlove3 Před 3 lety +1

    Good job Cory take care.

  • @edwyncorteen1527
    @edwyncorteen1527 Před 3 lety +2

    You should be able to remove the cupboard in front of the "consumer unit" by the cooker, find all the fittings holding it to the next cupboard and remove, check any going up into the worksurface, screw up the adjustable feet to give you room and it should slide out.

  • @ianbird6997
    @ianbird6997 Před 3 lety +3

    That was shocking so shocking, even I am not qualified and even I know that is not right... how do these people sleep at night, that is deffo house fire territory with 2.5m on the 50 amp breaker if the circuit got loaded. Hope the customer is glad you found all these safety issue good work guys 👍👍👍👍

  • @Suit2
    @Suit2 Před 11 měsíci

    2:29 you mean the m25 corrected plus the A12 😂😂

  • @rickterry8148
    @rickterry8148 Před 3 lety +1

    great video. You moan about it being a bad day and possibly walking away, but its not the customers fault and you have done the best thing, made an installation safe, that should give you a great feeling and job satisfaction, and the customer seems pretty happy that you are sorting it out for them. and you are getting paid. These people needed help and you are giving it to them. If I was an electrician, this would be one of the good days. Stay safe.

  • @johnschlesinger2009
    @johnschlesinger2009 Před 3 lety

    I haven't been in the trade for yonks, but one quick look would have told me that the whole thing would be a can of worms. I would have told the customer that a complete rewire was needed, and have left it at that. At least the customer would have saved a fair bit of dosh which could have gone towards a rewire, rather than paying to have a bodge tidied up and made reasonably safe. I have come across installations that looked neat, with a tidy c.u., only to fine a pile of connector blocks buried under plastered walls. And everything can test ok, and still be potentially lethal - cables slotted into joists, diagonal runs chased in, etc. Enjoyed the video....

  • @therzook
    @therzook Před 3 lety

    that is the same reason I avoid domestic installations, beside what is the point to deal with circuits with no bs88-3 fuses and with silly single phase, where current is below 50A...

  • @sqike001ton
    @sqike001ton Před rokem

    Also the plug in lights are really smart and I can see why even a half arser would use them it allows for easy change outs at a later date

  • @jensschroder8214
    @jensschroder8214 Před 3 lety

    Here in Germany we have 16 amps 1.5 mm radial socket lines. For 20 amps you need 2.5 mm.
    If a high load is to be expected or the cable is very long, thicker cables are required. Plugs have no fuses.
    Lamp circuits can be fed from socket circuits or, better still, have their own cables. The fuse is then 16 amps or less.
    Ring circuit are prohibited here.

  • @johnoreilly7052
    @johnoreilly7052 Před 3 lety

    Hi Cory thanks for sharing your video with me and I would like you to make more of your videos please

  • @brianwood5220
    @brianwood5220 Před 3 lety +2

    Great work ethic Cory. I love your style of teaching, and yes you do teach. Hey, i just thought. Want a job as a college lecturer?

  • @simonabbott7323
    @simonabbott7323 Před rokem

    Those solid green conductors were last compliant on 31 December 1977.

  • @shaneyg1988
    @shaneyg1988 Před 2 lety

    I'm from Wigan and your impression was pretty good tbh 👍

  • @adrianstavrakis9126
    @adrianstavrakis9126 Před 3 lety +2

    Exactly what I needed to make my day

  • @TeamSimpsonRacing
    @TeamSimpsonRacing Před 3 lety

    Always do an EICR first but never plan the board change the same day. I Don't even book in the board change untill we have the EICR results. For instance, did an EICR last week pre board change and the house ends up needing a rewire.

  • @AndyK.1
    @AndyK.1 Před 3 lety +2

    Old electricians did twist the Earths together. Kept them out the way and ensured a good and fool proof connection.

    • @wizard3z868
      @wizard3z868 Před 3 lety

      my preferred method still in the states but i use copper crimps and am starting to use wago's

  • @TheChipmunk2008
    @TheChipmunk2008 Před 3 lety +5

    *curvecurveball... mix of 1.0 and 1.5mm earthed 2.5 can drive you nuts.

  • @gordonbuttle272
    @gordonbuttle272 Před 3 lety +5

    Over here in New Zealand a job like that would probably be '"Filed in the too hard basket...."

    • @andrewpowell6457
      @andrewpowell6457 Před 3 lety +1

      for a lot of NZ sparky's probably yes you are right I've seen some terrible bodge wiring & others who took real pride in the job & nothing was too hard.

    • @rabsil100
      @rabsil100 Před 3 lety

      Why? Testing or obviously needs gutting and re-wired, friend? Hi from Scotland, spark, like me, methinks.

  • @tommymack3210
    @tommymack3210 Před 3 lety

    In Norway we have many 10-15-16A breakers

  • @steveb1856
    @steveb1856 Před 3 lety +2

    I’d take one of those cars instead of the designer milk float!🤣🤣

  • @richardday2893
    @richardday2893 Před 2 lety

    In Australia, we call volt sticks ' maybe sticks'.

  • @i_know_youre_right_but
    @i_know_youre_right_but Před 5 měsíci

    16:50 jesus christ this is absolutely unbelievable. Sometimes I feel like I’m too harsh on myself as a spark, then I come across things like this and realise I’m not so bad. To think a qualified electrician did this! And the cable joint with the cooker using connector blocks and tape??? I wouldn’t be able to sleep at night!

  • @andrew_koala2974
    @andrew_koala2974 Před rokem

    15:30 -- I am lost for words at the sight of this.

  • @davidkidner6648
    @davidkidner6648 Před rokem

    Thanks

  • @andrewwaters2390
    @andrewwaters2390 Před 2 lety +1

    The only reason the down lighters had clicks and a lovely bit of flex is that’s how those ones come in the box. Then they couldn’t even be bothered to sleeve the earth 😂😂😂😂😂😂😂😂

  • @kaysonntag74
    @kaysonntag74 Před 2 lety

    Customer service in old houses is always a surprise. Some pipes here are even still insulated with fabric or the insulation is so brittle that it crumbles between your fingers.
    It gets really interesting when one (or more) previous owners of the house have already "improved" something themselves.
    What the previous "electrician" did in your video is what I call a botched job.
    Is single-phase supply for flats / small houses still common in the UK?
    Here in Germany it is common to supply flats / houses three-phase. (With the exception of the "old stock", if nothing is changed in the installation, but only repaired).

  • @tcpnetworks
    @tcpnetworks Před 3 lety

    Our cable in Australia, the earth conductor is insulated by the manufacturer.

  • @user-sz9es3lu7l
    @user-sz9es3lu7l Před 8 měsíci

    We miss you on artisan channel

  • @user-qh7bw5ox5p
    @user-qh7bw5ox5p Před 2 lety

    Lovely tester! What make is it?....Really love your content, Keep it up

  • @neil6438
    @neil6438 Před 3 lety +1

    How do you rate the metrel tester ? I cant decide between this and the megger 1741+

  • @gmeadowcroft84
    @gmeadowcroft84 Před 3 lety +4

    I'm only 16 min in and I feel the need to comment. I might only be a Jr Spark but id stop right there and tell the customer it needs a re-wire..... I'm not sure how Cory calls this yet as like I said I'm only 16 min in but that's shocking! I don't think id ever junction a cooker I believe it should be a straight run to the isolation switch. the current going through that cable is high in my eyes and by putting a junction in there let alone how its done just screams fire to me. SHOCKING that's all i got to say

  • @dc-sd3gd
    @dc-sd3gd Před 3 lety +3

    R2 in a 2.5mm twin is 1.67 lager than the 1.5mm cpc because 2.5÷1.5= 1.67.
    So therefore if you had a ring (for example reason only) of 6mm twin with a 2.5mm cpc, the cpc should be 2.4 times higher because 6mm÷2.5mm=2.4.

  • @lewis94uk
    @lewis94uk Před 3 lety +7

    You guys might get sued for slander, that's quality work

  • @sparkyman4155
    @sparkyman4155 Před 2 lety

    O and here the favorite breakers are 20a and 16a. Love the vids cory😂

  • @neilbissett1240
    @neilbissett1240 Před 2 lety

    Top notch mate 👏👏😎

  • @zenaasura1769
    @zenaasura1769 Před rokem

    yea i had a few clients like that last year. where you start off really wrong. and then everything turns out to be fine.

  • @ytf2580
    @ytf2580 Před 3 lety

    i always see you using 2 leads and have 1 dangling, piggy back the N and PE cable on the metrel it will still work

  • @yardgrid
    @yardgrid Před 3 lety +1

    That unit would have slid out pretty easily i think but still daft. I noticed the "education" magazine on the table. I wonder if this customer got the cowboy a start at the college and is now having second thoughts?

  • @seancarley9871
    @seancarley9871 Před 2 lety +2

    I started watching this channel to learn a little something about electric work since I know nothing, I do concrete,stucco,drywall,carpentry, and long story short, I'm no longer interested in learning electric lmaooo, too complicated