Case 225: Manual of CTO PCI - antegrade wiring works

Sdílet
Vložit

Komentáře • 5

  • @shangz0216
    @shangz0216 Před rokem +2

    Thanks for the educative case presentation.

    • @jeddacath
      @jeddacath Před rokem

      Nice to see a straightforward case we can all do
      Question why TP LP as the antegrade MC and not the TP Spiral that may have crossed.

    • @manosbrilakis
      @manosbrilakis  Před rokem +2

      Great point - we used Turnpike LP because we were expected that we would have to go retrograde, but you are right that Turnpike Spiral might have helped.

  • @hifa63
    @hifa63 Před rokem +1

    Many thanks

  • @drmz2007
    @drmz2007 Před rokem

    Excellent case
    Anchor balloon could also give strong support.
    Reason for previous failure? Wire not crossed or balloon not crossed ?