  • Part two of my MEP 803A generator rebuild!
    In case you found this video first, here is a link to part one;
    • MEP 803A Rebuild - Part 1
    Here is a link on the rebuild of this generator on Steel Soldiers forum;
    www.steelsoldiers.com/threads...
  • Auta a dopravní prostředky

Komentáře • 35

  • @grenadespoon
    @grenadespoon Před 9 měsíci

    I babysat two of these all over the world some years ago. Pretty cool to see you working on them. Brings back memories.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 9 měsíci

      They're good generators and not bad to work on once you know them. Neglect is the big reason for failure on them.

  • @milcommguy5927
    @milcommguy5927 Před 11 měsíci +1

    Good Job

  • @philstreeter9703
    @philstreeter9703 Před 3 měsíci

    Great video. I picked up a Doosan G25 thst was inoperable and I got it running. The generator is pooched, so I'm fixing it up.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 2 měsíci

      Good luck! Always a challenge.

    • @philstreeter9703
      @philstreeter9703 Před 21 dnem

      I bought a Doosan G25 at auction and It starts but the governor shuts it off after 1 minute. It has good oil pressure, so I'm going to check the sensor.

  • @markm.9590
    @markm.9590 Před 3 měsíci

    Blow-by, from what I've learned is oil getting past piston rings or maybe Valve. Oil blowing Out of a Dipstick like you show, is Normal. Engine's I have do this. It is NOT "Blow-by" it is Normal. That's why most Engines have Crankcase Venting. Dipsticks go into the bottom of the engine where the Crankshaft spins also, that creates Splashing.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 3 měsíci +1

      No, it's not normal. I have serviced many of these units & a properly running one will have no oil or noticable pressure coming from the sump like that. It's combustion pressure and exhaust from worn or cracked rings. If it was a valve, the cylinder wouldn't fire. Oil pressure will never exceed combustion pressure, especially in a diesel engine. ~320psi if I remember correctly is pressure on these during compression.

  • @josephpuchel6497
    @josephpuchel6497 Před 9 měsíci

    Hey nice one not a bit of smoke

    • @CallMeColtLLC
      @CallMeColtLLC  Před 9 měsíci +1

      It has a dead cylinder. Going to rebuild it.... I hope.

  • @nathanielgrimes3882
    @nathanielgrimes3882 Před 2 měsíci

    Is it possible to add extensions to the exhaust pipe? For mine, I have it placed behind my house, under the eves and would like make it to where the exhaust goes up and away from the eves. Any ideas?

    • @CallMeColtLLC
      @CallMeColtLLC  Před 2 měsíci

      Thread onto the threaded fitting of the muffler. I'd recommend it not being under anything near your house.

  • @geoffreystevens9501
    @geoffreystevens9501 Před 9 měsíci

    Hello sir,
    Thank you posting all of your videos on CZcams. Great information. I recently bought about 4 of these generators on gov planet. I just got them delivered. I have been able to look at 2 of them so far. They all seem to be in good condition but need somethings.
    My question is, do you happen to have a video of you showing how to operate these from start to finish? I ask because two of the ones I have, I got power to them with new batteries and with the switch inside I can get it to turn over/ crank but it won’t start. When I go to the front panel on both of them there is no power to the front panel at all and the switch on the front panel it will not crank up there due to there not being any power.
    Do you know where I can start with this to figure out how to get them running? Thank you so much for your time.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 9 měsíci

      I saw your e-mail as well & am replying. This video shows CB1, it may be an easy thing to check. czcams.com/users/shortsAX9iZ3dL1yM

  • @brysonl51
    @brysonl51 Před 2 měsíci

    Hey I’m having issues getting coolant to flow into the radiator. I just bought this and it was drained/no batteries. Any thoughts on what the coolant wouldn’t actually go into the radiator?

    • @CallMeColtLLC
      @CallMeColtLLC  Před 2 měsíci

      Completely full of rust? I've seen a few really bad. Usually it all fills easily.

  • @sethblackman8445
    @sethblackman8445 Před měsícem +1

    hi i think you should change the rings and check the hoil engen and system two see what the problem is thate is my ecvice two you two

  • @smartorstrong
    @smartorstrong Před 9 měsíci

    Im wondering do you ship your MEP generators to your home? The reason I am asking is I am having trouble getting someone to ship a MEP 804 to my home in Alaska.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 9 měsíci

      You would need to higher a hauler or freight company to get it.

  • @johndonegan9086
    @johndonegan9086 Před 5 měsíci

    I’m have voltage issues with my mep-802a, do you answer questions about issues like that and if so how can I get in touch with you. Thanks

    • @CallMeColtLLC
      @CallMeColtLLC  Před 5 měsíci

      Troubleshooting specific problems without seeing the unit in person can be hard. Voltage issues can be a lot of things. The Technical Manual has a tree for troubleshooting voltage issues or you can see what other people have done on SteelSoilders. Could be as simple as a loose wire to a bad regulator or stator. I have a few threads of my own that are old, but I've gone through a lot of them. www.steelsoldiers.com/members/callmecolt.87810/#recent-content

  • @ricksanchez7459
    @ricksanchez7459 Před 6 měsíci

    How long did you run it under load? What did compression test yield?

    • @CallMeColtLLC
      @CallMeColtLLC  Před 6 měsíci

      I didn't run a compression test because there is no way to do so. I ran it under load ~45min, I think that's what I said in the video anyways.

    • @ricksanchez7459
      @ricksanchez7459 Před 6 měsíci

      @@CallMeColtLLC Probably a broke ring or rust pitted cylinder.

    • @ricksanchez7459
      @ricksanchez7459 Před 6 měsíci

      @CallMeColtLLC They make a rubber tipped compression pipe, it's tough to use.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 6 měsíci

      @@ricksanchez7459 I wouldn't trust that for something like this. I already know with the symptoms it needs to be taken down anyway, just need to get to it. 😎

  • @AlAndaluz63
    @AlAndaluz63 Před 4 měsíci

    Hey Devil dog you have anyone in your network that does Gen maintenance in South Florida?

    • @CallMeColtLLC
      @CallMeColtLLC  Před 4 měsíci

      No, I'm sorry. Most of the basic stuff is simple. Go for it!

  • @nattydreadlocks1973
    @nattydreadlocks1973 Před 9 měsíci

    The cost to repair these generators is outrageous. Not so much the engine itself but all the electronics.

    • @CallMeColtLLC
      @CallMeColtLLC  Před 9 měsíci

      On all the generators I have worked on, the electrical side usually is fine and just has something loose or needing to be cleaned up. Unless of course it's a missing gauge. Good, tested components do pop up. It's why I started my business.

    • @ricksanchez7459
      @ricksanchez7459 Před 6 měsíci

      That masterswitch tho

  • @Jeff-yu9vf
    @Jeff-yu9vf Před 4 měsíci

    Where’s part 3?? 🤷‍♂️

    • @CallMeColtLLC
      @CallMeColtLLC  Před 4 měsíci

      I'm slow! It's on the list. Took a while to gather everything I might need. Now I need the time. It makes a project 2-3 times longer to document it. I want it done. Hopefully soon.