Fire Hydrant System | NFPA Fire Hydrants |Fire fighting | in Urdu/Hindi

Sdílet
Vložit
  • čas přidán 21. 11. 2020
  • This is a fire fighting System video about "Fire Hydrant System/ NFPA fire hydrants/ external fire hydrant/ MEP hydrants/ Pillar hydrant system" in Urdu/Hindi language. I have explained the system's conceptual understanding of each component function. It is basic learning detail information about Hydrant System. It is also important for Firefighting/MEP technical staff. Here sharing my experience and knowledge that will be helpful to learn & grow for Engineers & Technical staff.
    I have explained the fire hydrant System i.e.
    1. What is the fire hydrant System?
    2. Why this system is used and installed?
    3. Main components explained.
    Moreover, you can study the blogs/articles by Engr. Tanweer Ahmed through clicking following:
    1. Fire Hydrant System
    Link: bit.ly/3zTI13B
    2. Types of fire hydrants
    Link: bit.ly/3DstCgD
    3. Where should fire hydrants be installed?
    Link: bit.ly/3sD30aq
    Related fire fighting videos for your watching:
    1. NFPA-14 Pipe Schedule Method for Standpipe
    Video's link: • NFPA 14 Pipe Schedule ...
    2. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
    Video's link: • NFPA 14 Flow Rate Requ...
    3. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
    Video's link: • NFPA-14 Pressure Desig...
    4. NFPA-14 Classes of Standpipe Systems
    Video's link: • NFPA-14 Classes of Sta...
    5. NFPA-13 Pipe Schedule Method Designing
    Video's link: • NFPA 13 Pipe Schedule ...
    6. NFPA-13 Sprinkler Heads Distribution
    Video's link: • NFPA-13 Sprinkler Head...
    7. NFPA-13 Density & Area of Sprinkler Operation
    Video's link: • NFPA 13 Density & Area...
    8. NFPA-13 Sprinklers Discharge Characteristics
    Video's link: • NFPA-13 Sprinklers Dis...
    9. Kitchen Fire Extinguishers
    Video's link: • Kitchen Fire Extinguis...
    10. Testing of Wet Riser Landing Valve System
    Video's link: • Testing of Wet Riser L...
    11. Fire Hose Reel System
    Video's link: • Fire Hose Reel System ...
    12. Testing of Fire Hose Reel System
    Video's link: • Testing of Fire Hose R...
    13. Converting Pump Head to Pressure or Vise Versa
    Video's link: • Converting Pump Head t...
    14. Difference Between Pressure Reducing & Pressure Restricting Valve
    Video's link: • Difference Between Pre...
    15. Difference Between Pressure Relief & Pressure Safety Valve
    Video's link: • Difference Between Pre...
    16. Combined Firefighting System Water Demand
    Video's link: • Combination Standpipe ...
    17. Types of fire sprinkler system of fire suppression systems
    Video's link: • Types of fire sprinkle...
    18. Dry Pipe Fire Sprinkler System
    Video's link: • Dry Pipe Fire Sprinkle...
    19. Preaction Sprinkler System NFPA13
    Video's link: • Preaction Sprinkler Sy...
    20. Single Interlock Preaction Sprinkler System
    Video's link: • Single Interlock Preac...
    21. Double Interlock Preaction Sprinkler System
    Video's link: • Double Interlock Preac...
    22. Main Components of Fire Fighting Pump Room Part-1
    Link: • Main Components of Fir...
    23. Main Components of Fire Fighting Pump Room Part-2
    Link: • Main Components of Fir...
    24. Main Components of Fire Sprinkler System Part-1[Except Pump Room]
    Link: • Main Components of Fir...
    25. Main Components of Fire Sprinkler System Part-2 [Except Pump Room]
    Link: • Main Components of Fir...
    26. Testing of Fire Sprinkler System & operation of ZCV assembly
    Link: • Testing of Fire Sprink...
    27. Deluge Foam Water Sprinkler System Part-2A
    Link: • Foam Deluge Valve Oper...
    28. Deluge Foam Water Sprinkler System Part-2B
    Link: • Deluge Foam Water Spri...
    29. Deluge Water Sprinkler System Part-1
    Link: • Deluge Water Sprinkler...
    30. Fire Hydrant Basic Requirements
    Video's link: • Fire Hydrant Basic Req...
    31. Types of Fire Hydrants
    Video's link: • Types of Fire Hydrants...
    32. Installation Detail of Fire Hydrant System
    Video's link: • Installation Detail of...
    #TanweerAhmed #hydrant #Firefighting #MEP #Tutorial #firehydrant #hydrants #mep #nfpa
    = YOU CAN FOLLOW ME ON SOCIAL MEDIA =
    WEBSITE: engineertanweerahmed.com/
    FACEBOOK: web. EngrTanweerA...
    LINKEDIN: / tanweer-ahmed-00142631
    CZcams: / tanweerahmed
    TIKTOK: vm.tiktok.com/ZSJReMqYx/
    INSTAGRAM: / tanweersethar
    TELEGRAM GROUP: t.me/hvacmepenggg
  • Věda a technologie

Komentáře • 143

  • @TanweerAhmed
    @TanweerAhmed  Před 2 lety +2

    Installation detail of fire hydrant system: czcams.com/video/ciQOTDeITmA/video.html

  • @mohammadwaseem523
    @mohammadwaseem523 Před 3 lety +2

    Thanks for sharing such knowledgeable videos for learners

  • @malik2023
    @malik2023 Před 2 měsíci +1

    Best Course.

  • @abuUmamah2134
    @abuUmamah2134 Před 3 lety +1

    Jazaak Allahu Khairan kaseeran @ Tanveer bhai

  • @acces2894
    @acces2894 Před 2 lety

    Very good explanation. Thanks

  • @bhushankapadnis41
    @bhushankapadnis41 Před 2 lety +1

    Bhai ur star.. thank you from india

  • @MEP.ENGINEERING.WORKS92
    @MEP.ENGINEERING.WORKS92 Před rokem +1

    Thank you for knowledge sharing it's a well explained video thanks for your video

  • @dayashrestha6982
    @dayashrestha6982 Před 11 měsíci +1

    informative. Thank you

  • @Vivek07072
    @Vivek07072 Před 2 lety

    Bohat shandaar samjhate ho aap sir

  • @mohammedmubeen2832
    @mohammedmubeen2832 Před 3 lety +2

    Engr Tanveer Ahmed
    Good Mentoring and Thanks for the videos concepts is cleared.

  • @manishjangir5109
    @manishjangir5109 Před 3 lety +1

    Keep doing the good Job.

  • @ramakrishnat6666
    @ramakrishnat6666 Před 2 lety +1

    Very good explanation sir.

  • @ZakirKhan-vk7vx
    @ZakirKhan-vk7vx Před 2 lety +1

    Sir g thank you
    so great job

  • @promotionalman3946
    @promotionalman3946 Před rokem +1

    Kamal kar dia apne

  • @sunilraj4423
    @sunilraj4423 Před rokem +1

    Good concept

  • @mohammedsaleem6751
    @mohammedsaleem6751 Před 2 lety +1

    Mashallah. Good job!

  • @jimmyjohn4070
    @jimmyjohn4070 Před 3 lety +1

    Thank you....

  • @kKhan-xi8zp
    @kKhan-xi8zp Před 3 lety +1

    Thank you sir

  • @VikasSingh-sq8pk
    @VikasSingh-sq8pk Před 3 lety +1

    Nice explanation bhai

  • @alisher9528
    @alisher9528 Před 2 lety +1

    Very nice 👍👍👍 good job

  • @sunilraj4423
    @sunilraj4423 Před rokem +1

    Awesome

  • @MDsaddam-uj8iv
    @MDsaddam-uj8iv Před 3 lety +1

    Thanks sir

  • @SOHANSINGH-sy4eu
    @SOHANSINGH-sy4eu Před 3 lety +1

    Good sir je

  • @atif-aftab1atif330
    @atif-aftab1atif330 Před 2 lety +1

    Great

  • @noorulhassan5897
    @noorulhassan5897 Před rokem +1

    1 no

  • @mohdrashid1769
    @mohdrashid1769 Před 3 lety +1

    Very Nice.👍👍👍

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Thank you

    • @mohdrashid1769
      @mohdrashid1769 Před 3 lety

      @@TanweerAhmed sir please send me your whatsapp group link on my email id rashid2523@gmail.com

  • @arbindkumarprajapati1165
    @arbindkumarprajapati1165 Před 3 lety +1

    👍

  • @sunilraj4423
    @sunilraj4423 Před rokem +1

    Good

  • @ranarashid8837
    @ranarashid8837 Před 3 lety +1

    good

  • @ziyamasad2709
    @ziyamasad2709 Před 3 lety +2

    Dear Sir,thanks for your knowledge sharing.please let me ,if the the system consist of stand pipe with FHC ,Wet sprinkler and Fire hydrants,then how to calculate required max gpm and pump head .in previous videos we saw max gpm in most remote stand pipe with landing valves and fhc and sprinkler.if the system consist of Fire hydrants...then how to calculate pump head and gpm.

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Most remote means away distance from pump, if your combine system then you have check most remote distance is which one. Most remote is required for pump head pressure and flow required design by two hydrant, sprinkler remote area, two hose cabinet etc. Finally I will say that I have not grip in design therefore suggest to coordinate with firefighting designer for this.

  • @ajiazahmed832
    @ajiazahmed832 Před rokem +1

    Assalamualikum sir please can you explain and upload the video of water mist system

  • @TanweerAhmed
    @TanweerAhmed  Před 3 lety +5

    Note: In hydrant system, Working pressure should be between 100psi to 175psi and pipe design working pressure should not less than 150psi.

  • @vashishthparikh
    @vashishthparikh Před 2 lety +2

    How can we design fire hydrant system for internal building and for external building, like distance between 2 hydrant and all, do you have same video for fire hydrant design?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      some my videos are available on youtube channel

  • @RanaAhmed-tb3oy
    @RanaAhmed-tb3oy Před 10 měsíci +1

    Let me know the reason standpipes pressure is varying between 120 to 200 psi even after switching off all pumps for whole day.

    • @TanweerAhmed
      @TanweerAhmed  Před 10 měsíci

      Pressure gauges or pressure switches problem or leakages

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY Před 3 lety +1

    Excellent sir, how much distance we have to keep between Hydrant, moreover, if our building pressure design 175 psi and as u said pressure at fire hydrant will be minimum 150 psi, shall we need to install PRV because of 175 psi

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Thanks
      1. Distance between hydrant to be 50meters
      2. As per NFPA-24-2007 Pipe design working pressure not less than 150psi
      3. We use working pressure minimum 100psi and maximum 175psi
      Note:- in next video further details will be share.

  • @thepurposeofmyexistence2511

    Dear sir , can u explain what when its complasory to instll fire hydrant , like if area of building exceed some value or

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      Building or property protection or firefighting from outside, therefore fire hydrants are compulsory

  • @dayashrestha6982
    @dayashrestha6982 Před 11 měsíci +1

    Can we connect the fire hydrant post and main riser pipe? Does it is needed to connect separate pipe line for hydrant post from pump.? Does hydrant post near entrance gate can feed to riser? What is difference between hydrant post and breaching inlet?

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci +1

      Breaching inlets serve as an additional water source for firefighting when the primary water supply from fire water tank or municipal water mains is insufficient or unavailable.
      The primary purpose of a hydrant post is to provide a readily available and reliable water supply for firefighting operations in different areas. Firefighters can quickly connect their hoses to the hydrant post to access water for extinguishing fires.

    • @dayashrestha6982
      @dayashrestha6982 Před 11 měsíci

      @@TanweerAhmed thanks

  • @dwiaris6037
    @dwiaris6037 Před 2 lety +1

    Sir plz tell me which nfpa standard required for determine main fire pump capacity of hydrant system.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      Capacity of fire pumps calculate through hydraulic calculation and NFPA-20 standard is used for fire pumps details

  • @Hayatkhan-xz4hh
    @Hayatkhan-xz4hh Před 3 lety +1

    Sir want to know today i test hydrant so back said smile bolt and come water that's hole for what have back said

  • @danishnoor2821
    @danishnoor2821 Před 3 lety +1

    Sir piv valve ke uper video banye

  • @enggrizwan3733
    @enggrizwan3733 Před 2 lety +1

    For fire hydrant system is the pump room is different or same?

  • @shahjahanansari4786
    @shahjahanansari4786 Před 3 lety +1

    Sir. Fire pupm pressure switch ka cut in and cut out setting ka ek video banaye... please sir

  • @michaelbalgos3749
    @michaelbalgos3749 Před 3 lety +1

    Is 1500gpm 190 psi 2700hp diesel fire pump can deliver to 6"diax466m pipe with 10 fire monitors for fuel tank depo.

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety +1

      Yes from my point of view, but further fire fighting designer may confirm

  • @dayashrestha6982
    @dayashrestha6982 Před 11 měsíci +1

    I am sanitary engineer from Nepal. I am currently designing the building plumbing water supply and sanitary design and drawings. I am interested in Fire fighting design too.

  • @sachal8547
    @sachal8547 Před 3 lety +1

    Sir fire hydrant female cupping change krne ka batay

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      It is simple, what do you know about its changing?

  • @nizamuddinz4392
    @nizamuddinz4392 Před 5 měsíci +1

    consider there is only hydrant system, no sprinkler and hose reel, stand pipe. 1. how to find no of hydrant pillar 2. each hydrant need how much flow gpm. 3. hydraulic calculation 4. tank design 5. pump running duration 45, 60, 90 minutes. 6. pump selection for combined sprinkler and standpipe 1000 GPM maximum. and only standpipe 1250 GPM. for Hydrant system alone how much GPM need to be considered.

  • @bradleycooper5567
    @bradleycooper5567 Před rokem

    Sir should i keep hydrant mains underground or above the ground.
    I want to keep pressurized mains above the ground, is there any side effect of this action?

  • @jiljungjuck9154
    @jiljungjuck9154 Před 2 lety +1

    Hi sir.. Can I use nfpa 14 to do fire hydrant system? Because I'll have standpipe system inside building. So I'm thinking to combine both fire hydrant system and standpipe system.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety +1

      Yes you can

    • @jiljungjuck9154
      @jiljungjuck9154 Před 2 lety

      @@TanweerAhmed thank you sir. I'm actually looking for the sections..so far I see what's written in class 1,2 or 3 systems didn't mention anything on hydrant systems. Kindly let me know which section to refer sir. Thank you

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Section 7.9.3 of NFPA 14: Standard for the Installation of Standpipe and Hose Systems (2019 edition) provides guidance on the connection of standpipe systems to exterior water supply sources, including fire hydrants. The section states:
      "7.9.3 Connection to Exterior Water Supply.
      7.9.3.1 A connection shall be provided between the standpipe system and the exterior water supply for use by fire departments and others in controlling and extinguishing fires in the building.
      7.9.3.2 The connection shall be in accordance with Section 7.11.
      7.9.3.3 Hose lines shall be provided for use with the connection, in accordance with Section 7.10."
      This section requires that a connection be provided between the standpipe system and the exterior water supply, which may include fire hydrants, for use by fire departments and other first responders in controlling and extinguishing fires in the building. The connection must be in accordance with Section 7.11, which provides requirements for the location, size, and type of connections, as well as the use of fire department connections (FDCs) and other fittings. Hose lines must also be provided for use with the connection, in accordance with Section 7.10.
      Overall, this section of NFPA 14 is intended to ensure that standpipe systems are properly connected to external water supplies to provide an adequate water supply for firefighting purposes.

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      NFPA 24: Standard for the Installation of Private Fire Service Mains and Their Appurtenances provides requirements for the installation of water supply systems, including fire hydrants, for use by fire departments in private properties. This standard includes guidance on the installation of FDCs, as well as the sizing and placement of fire hydrants to ensure adequate water supply for both standpipe and sprinkler systems.
      Section 7.2.2: "Fire Department Connections." (2019 edition)
      Section 10.6: "Private Fire Hydrants." (2019 edition)

  • @mohdsalman9558
    @mohdsalman9558 Před 2 lety +1

    Dear sir plz tell me which NFPA Standard required for Hydrant system..

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      NFPA-1 and NFPA-24

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      For design fire hydrant system, these NFPA standards should study NFPA 1, NFPA 24, NFPA 291, NFPA 14, NFPA 1963 and NFPA 20

  • @asadkhattak1774
    @asadkhattak1774 Před rokem +1

    Sir pump room hai ye

  • @deepakkhotkar9785
    @deepakkhotkar9785 Před rokem +1

    Fire hydrant discharge kitna hota hai 1 minutes mai

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      250 maximum gallons in one minute for 2.5" hose connection

  • @salmanakhtar8382
    @salmanakhtar8382 Před rokem +1

    Assalamualaikum wrahmatullahi wabrakatuh
    Sir i am designing warehouse and hight of warehouse is 4.5 MTR, for designing of Ringling hydrant
    How many hydrant shall be considered for calculation???
    And kindly suggest codes for designing of ring line hydrant system

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      I think two hydrant will be consider for design but further confirm from other sources

  • @shoeabkhan8939
    @shoeabkhan8939 Před 2 lety +1

    Sir i have question related to fire hydrant

    • @shoeabkhan8939
      @shoeabkhan8939 Před 2 lety +1

      Sir app nai bola hai 50m distance between two hydrant but sir. Its depends upon occupancy
      Like high hazard building occupancy
      Medium hazard building occupancy
      Low hazard building occupancy
      So my question is what distance between two hydrant according to occupancy
      And life of hydrant
      And duration of testing like yearly or quarterly or half.

    • @TanweerAhmed
      @TanweerAhmed  Před 2 lety

      This distance is for all hazards

    • @shoeabkhan8939
      @shoeabkhan8939 Před 2 lety

      @@TanweerAhmed and sir hydrant system life and. Duration of test

  • @user-sd7zu9ue8t
    @user-sd7zu9ue8t Před 2 lety

    For fire fighting equipment , where your office.

  • @shahjahanansari4786
    @shahjahanansari4786 Před 3 lety +1

    1 hydrant se 2 hydrant ki dori kay hoti hai aur hydrant me kitna pressure hota hai ?

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Watch my other hydrant videos, your required info is given

  • @ravi-lg4jh
    @ravi-lg4jh Před rokem +1

    You have notes

  • @speakbuddy3844
    @speakbuddy3844 Před 3 lety +1

    Sir Aapne Fire safety mein engineering ki hai ?

  • @vijayparkashprakash9058
    @vijayparkashprakash9058 Před 3 lety +1

    Floring level se ringline kitana hona chahiye

    • @TanweerAhmed
      @TanweerAhmed  Před 3 lety

      Watch my video "installation detail of fire hydrant" then you will get the answer

  • @hamoodkhan1573
    @hamoodkhan1573 Před rokem +1

    Can we install a 6 inches PRV on hydrant main 6 inches dia lines?

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      PRV (Pressure Reducing Valve) ?

    • @hamoodkhan1573
      @hamoodkhan1573 Před rokem +1

      @@TanweerAhmed Yes Pressure reducing valve in 6 inches lines.

    • @TanweerAhmed
      @TanweerAhmed  Před rokem +1

      If pressure in high from design requirements then may be used and further also depends on installed system requirements

    • @hamoodkhan1573
      @hamoodkhan1573 Před rokem +1

      @@TanweerAhmed Thanks sir

    • @TanweerAhmed
      @TanweerAhmed  Před rokem

      Welcome

  • @ramakrishnat6666
    @ramakrishnat6666 Před 2 lety +1

    R u from which country??

  • @human20101
    @human20101 Před 3 lety +1

    I wish this explanation was in English.. I can’t understand any thing

  • @mirhafeez5856
    @mirhafeez5856 Před 3 lety +1

    Good