How to Size a Fire Pump Room | NFPA 20 Requirements in Urdu

Sdílet
Vložit
  • čas přidán 24. 07. 2023
  • In this video, we'll explain the important topic of how to size a fire pump room or sizing a fire pump room according to NFPA 20 requirements. As a critical component of any fire protection system, the fire pump room must be designed and sized correctly to ensure that clearance between components for installation and maintenance is provided properly and it can effectively supply water to the firefighting system in the event of a fire. We'll cover the key factors that need to be considered when sizing a fire pump room, including the size of the building, the type of fire pump, the diesel fuel tank, and electric control panels. We'll also provide practical tips and advice on how to ensure that your fire pump room meets all the necessary NFPA 20 requirements. Whether you're a fire protection engineer, a building owner, or just interested in learning more about fire safety, this video is a must-watch. So, join us as we explore the world of fire pump rooms and NFPA 20 requirements!
    Thank you for watching and supporting our channel. Remember to check out our other videos for more valuable content on related topics:
    1. NFPA-14 Pipe Schedule Method for Standpipe
    Video's link: • NFPA 14 Pipe Schedule ...
    2. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
    Video's link: • NFPA 14 Flow Rate Requ...
    3. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
    Video's link: • NFPA-14 Pressure Desig...
    4. NFPA-14 Classes of Standpipe Systems
    Video's link: • NFPA-14 Classes of Sta...
    5. NFPA-13 Pipe Schedule Method Designing
    Video's link: • NFPA 13 Pipe Schedule ...
    6. NFPA-13 Sprinkler Heads Distribution
    Video's link: • NFPA-13 Sprinkler Head...
    7. NFPA-13 Density & Area of Sprinkler Operation
    Video's link: • NFPA 13 Density & Area...
    8. NFPA-13 Sprinklers Discharge Characteristics
    Video's link: • NFPA-13 Sprinklers Dis...
    9. Wet Riser Landing Valve System
    Video's link: • Wet Riser Landing Valv...
    10. Testing of Wet Riser Landing Valve System
    Video's link: • Testing of Wet Riser L...
    11. Fire Hose Reel System
    Video's link: • Fire Hose Reel System ...
    12. Testing of Fire Hose Reel System
    Video's link: • Testing of Fire Hose R...
    13. Where PRV is required as per Pressure in the Firefighting System?
    Video's link: • Where PRV is required ...
    14. Combined Firefighting System Water Demand
    Video's link: • Combination Standpipe ...
    15. Types of fire sprinkler systems fire suppression systems
    Video's link: • Types of fire sprinkle...
    16. Sprinkler Deflector Position NFPA 13 Unobstructed
    Video's link: • Sprinkler Deflector Po...
    17. Sprinkler Deflector Position NFPA 13 Obstructed
    Video's link: • Sprinkler Deflector Po...
    18. NFPA 13 Sprinkler Distance Below Slop Ceiling
    Video's link: • NFPA 13 Sprinkler Dist...
    19. Supervisory Valves in Firefighting
    Video's link: • Supervisory Valves in ...
    20. Riser Check Valve for Wet Pipe Sprinkler System NFPA 13R
    Video's link: • Riser Check Valve for ...
    21. Alarm Check Valve Assembly - ACV Complete Detail
    Video's link: • Alarm Check Valve Asse...
    22. Inspectors Test & Drain Valve for ZCV Assembly
    Video's link: • Inspectors Test & Drai...
    23. Fire Fighting Systems for Healthcare Facilities
    Video's link: • Fire Fighting Systems ...
    24. Domestic Fire Protection Explained | Fire Safety Measures
    Video's link: • Domestic Fire Protecti...
    25. Commercial Fire Protection Explained | Fire Safety Measures
    Video's link: • Commercial Fire Protec...
    #TanweerAhmed #pump #firefighting #firepump #size #room #nfpa #nfpa20 #mepengineering #fire #project #pumproom #roomsize
    = YOU CAN FOLLOW ME ON SOCIAL MEDIA =
    WEBSITE: engineertanweerahmed.com/
    FACEBOOK: web. EngrTanweerA...
    INSTAGRAM: / tanweersethar
    LINKEDIN: / tanweer-ahmed-00142631
    CZcams: / tanweerahmed
    TIKTOK: vm.tiktok.com/ZSJReMqYx/
    TELEGRAM GROUP: t.me/hvacmepenggg
  • Věda a technologie

Komentáře • 59

  • @faridkhan-mf5xg
    @faridkhan-mf5xg Před 11 měsíci +1

    Thanks sir. This was my request.

  • @dayashrestha6982
    @dayashrestha6982 Před 11 měsíci +1

    Thank you very much for this video. Great

  • @vijaybajaj401
    @vijaybajaj401 Před 11 měsíci +2

    Vieweres are requested to like yhe video bcoz people are commenting but not pressing like butten 😂

  • @faridkhan-mf5xg
    @faridkhan-mf5xg Před 11 měsíci +1

    ❤Mashallah sir

  • @imam4110
    @imam4110 Před 11 měsíci +1

    Thanks for explaining in very easy way.
    Kindly give more detail if possible including control panel, sensing line etc.
    If you can share the slide here in youtube it will be very helpful.

  • @faridkhan-mf5xg
    @faridkhan-mf5xg Před 11 měsíci +1

    Sir fire fighting system Mai ik valve se dusry valve tak Kitna distance hona chayie. Like zcv ke case Mai ya pump installation Mai.

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      I have informed in video "Inspector test & drain valve of ZCV assembly" please watch

  • @vijaybajaj401
    @vijaybajaj401 Před 11 měsíci +1

    Suction me osY valve with tamper switch lagana hai so 10d ke bad lagayenge ya centre me laga sakate hai

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      You can install OS&Y at any point but 10D is must.

  • @mdfaiyazkhan9663
    @mdfaiyazkhan9663 Před 2 měsíci +1

    Kindly request to share that Which type of firefighting system install in the fire pump room where diesel tank available l?

    • @TanweerAhmed
      @TanweerAhmed  Před 2 měsíci

      Foam system used for diesel tank protection and water system for respect area. From my point of view.

  • @asadkhattak1774
    @asadkhattak1774 Před 11 měsíci +1

    Sir fireman interive k bare me video banao

  • @sureshdas9323
    @sureshdas9323 Před 2 měsíci

    Thank u sir... I want to fire pump pipe selection

    • @TanweerAhmed
      @TanweerAhmed  Před 2 měsíci

      Pipe selection means material or sizes or something else?

  • @user-gd7ty4uc1h
    @user-gd7ty4uc1h Před měsícem +1

    AOA Sir. Kindly Share Firefighting design report samples and how to make it

  • @imam4110
    @imam4110 Před 11 měsíci +1

    Assalamo alaikum
    Kindly make a detailed video on Fire Pump maintenance(inside fire pump room only) including all the equipments and parts.

  • @waseemakram9546
    @waseemakram9546 Před 11 měsíci +1

    Which software will you prefer for fire fighting Calculations

  • @arbabali2170
    @arbabali2170 Před 4 měsíci +1

    What should be the volume of fire water tank without sprinkler system ?

    • @TanweerAhmed
      @TanweerAhmed  Před 4 měsíci

      Fire water tank design based on system water capacity as per standard requirements. One my video is available for your reference on my channel.

  • @ak-lr5jc
    @ak-lr5jc Před 11 měsíci +1

    Also, what are major differeces between UL/FM listed valves/fittings and non UL/FM listed valve/fittings. I am asking as at one of the site, contractor was trying to put a non UL/FM listed isolation valve along with an external fire hydrant and was mentoning that their is no big difference..can you plz elaborate?

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      A listed valve offers the assurance that it has been independently tested and meets specific safety and performance standards. On the other hand, a valve that is not listed lacks this third-party verification, making it potentially less certain in terms of compliance and performance. When safety is a top priority, using listed valves is generally recommended, especially in critical applications like fire protection systems.

  • @asadkhattak1774
    @asadkhattak1774 Před 11 měsíci +1

    Or sir aagy barnee k lye kon kon se course krne chahiye

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci +1

      What is your education and interest in field, as I can suggest accordingly

  • @imranhadi8505
    @imranhadi8505 Před 8 měsíci +1

    Sir please ye bataiye ki area ke according kaise pata kare ki yaha par kitna GPM ka pump chahiye .? Please explain

  • @ak-lr5jc
    @ak-lr5jc Před 11 měsíci +1

    will the same rules apply for hvac pumps, piping and their fittings?

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      May be or may not be. Suggest to review HVAC standards and guidelines about HVAC plant room size and clearances.

    • @taqirkan7712
      @taqirkan7712 Před 11 měsíci +1

      @@TanweerAhmed thnx

  • @amitkhedekar8473
    @amitkhedekar8473 Před 10 měsíci +1

    Tanweer bhai, Siamese connection aur Breaching inlet mein kya farak hai ?

    • @TanweerAhmed
      @TanweerAhmed  Před 10 měsíci

      "Siamese connection" zyada hoses ko ek sath paani supply karne ke liye hota hai jabki "breaching inlet" building ke andar ya paas water supply ko facilitate karne ke liye hota hai.

  • @ak-lr5jc
    @ak-lr5jc Před 11 měsíci +1

    Assalam O Allikum....is their any clause in NFPA (or a common practice) which indicates that plant room shud not have any columnns ( to avoid any hinderance in piping)?

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      W.Salam,
      I think, there is no clause as per my knowledge. Further, review at your end or Consult with any fire fighting specialist.

    • @taqirkan7712
      @taqirkan7712 Před 11 měsíci

      @@TanweerAhmed thnx

  • @mdsagor8761
    @mdsagor8761 Před 11 měsíci +1

    Bangladesh

  • @imranhadi8505
    @imranhadi8505 Před 3 měsíci +1

    Is it permissible to place fire pump on roof of the building?

  • @Baharan2011
    @Baharan2011 Před 11 měsíci +1

    How flow meter installation in fire pump

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      What is problem in installation regarding flow meter?

    • @Baharan2011
      @Baharan2011 Před 11 měsíci

      Distance between flow meter to valve

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci +1

      That minimum distance is in reference to the length minimum of STRAIGHT pipe, as based on 2 or 5 diameters of pipe before and after the flow meter.

  • @hanishmuhammed7259
    @hanishmuhammed7259 Před 11 měsíci +1

    Assalamu alaikm, can you provide the pdf drawings for vertical pump installation. It will be a great help

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      W.Salam,
      Let me check drawing

    • @hanishmuhammed7259
      @hanishmuhammed7259 Před 11 měsíci

      @@TanweerAhmed thanks bhai

    • @hanishmuhammed7259
      @hanishmuhammed7259 Před 11 měsíci +1

      @@TanweerAhmed sir any updates regarding drawings. It will help me a lot.

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      I have just plan layout drawing. Installation followed by manufacturer installation manual

    • @TanweerAhmed
      @TanweerAhmed  Před 11 měsíci

      @@hanishmuhammed7259 share email, I will forward or join my Telegram group "HVAC|MEP Engineering"