Heat Exchanger Swap on an RTU! Running Multiple Service Calls as an HVAC Technician in New York!

Sdílet
Vložit
  • čas přidán 26. 02. 2024
  • Thanks for watching! I hope you enjoyed. Please leave any thoughts, feedback, comments, criticism, or advice in the comment section. Thumbs up, and subscribe to see more content!
    Like my videos? Check out and consider subscribing to:
    ‪@HughesManHVAC‬
    ‪@Maine207HVAC‬
    ‪@PipeDoctor‬
    ‪@MikeyPipesOrlando‬
    ‪@mikeypipesphilanthropy‬
    ‪@diyhvacguy‬
    ‪@TedCookHVAC‬
    ‪@QualityHVACR‬
    ‪@HVACGUY‬
    ‪@misfitsofhvac‬
    Below are links to my most important tools that I carry daily, and links to reach me through different methods of social media!
    My Tools and Tool Bag:
    amzn.to/3CUM6rI
    Other HVAC Tools I keep in my Van!
    amzn.to/44sqgYl
    Venmo:
    venmo.com/DCHVAC
    Follow me on Instagram:
    @dc.hvacr. invitescon...
    Follow me on TikTok:
    www.tiktok.com/t/ZTdv7DK3D/
    Need to get in touch? Email me at dchvac123@gmail.com

Komentáře • 68

  • @davidlampe4153

    Well I’m glad that Josh is consistent, consistently awful about showing up to work on time! Good by and good riddance!

  • @scottvolage1752

    Good Job Daniel. She's a crusty one Mamma. Make the trades safe again Daniel. The fins slow the combustion gasses down so more heat is transferred to the heat exchanger. Smash that like button and Subscribe please people.

  • @veronicacampbell9197

    Nice work🎉I’m sure Mike appreciates the good workers even more when others are no shows.

  • @christopheromeara689

    Great job Danial. As far as a Josh goes. You can’t change a bros spots. Lol

  • @AnonymaxUK

    First time I heard a tech explain why teflon shouldn't be used on gas fittings, nice!

  • @sullivanbob2000

    Glad to see you had great weather for this job !

  • @tphvac87

    3:42

  • @timothyfink9354

    another fun day at the office

  • @veronicacampbell9197

    Campbell brothers save the day 😊

  • @kylebass4635

    Excellent work as always Daniel!!!!! Hate that dude has cancer but he should never have done a " repair " like that. Bonus is you figured out the problem your other co workers could not figure out. Huge asset to the company. My boiler has the old school expansion tank mounted to the basement ceiling I drain myself. Runs 12-15psi with cast iron radiators. Pressure at 20 still sounds good to me as well.

  • @gtpforever

    I can smell this video clear over here in Ohio. 😂🤣😂🤣

  • @kens.3729

    Hacks Kill Unsuspecting Homeowners. 🤪👎

  • @steveg5576

    Keep in mind --for a small crane you can call a tractor trailer tow wrecker / rotator to get most anything on 2 stories or so. Check into it sometime.

  • @paulyanega2373

    good work !!

  • @michaelsannuti270

    Good job 👍🏽

  • @scottmaz4063

    Jobs well done Daniel

  • @TheRAMBO9191

    We all told Mike it was a bad idea. His problem. Lol

  • @nonamesplease8228

    As long as the two transformers are in phase you can have two. It is when they are wired to two different phases on the primary side that things don't go well

  • @scottmaz4063

    #1🎉🎉🎉😂😂😂

  • @billnahorn3939

    Don’t know anything about boilers but if I installed one I would always put a tee where the pressure gauge is that way you could install your own,make sure there’s is correct. Keep up the good work ( very smart young man)