    Any cells you see on this channel, unless otherwise mentioned, can be purchased from Amy Zheng from Docan Power. For best service and best price send her an email at amy@docanpower.com and mention this channel (Yes, I'm an affiliate and may make a dollar or 2 from the sale). I buy my cells from Amy exclusively (well 99% of the time anyways). Never a bad experience in many orders.
    If you like these videos, please show your support by buying me a cup of coffee here: www.buymeacoffee.com/notoshaa...
    Thanks for watching!

Komentáře • 13

  • @ScottieBMan
    @ScottieBMan Před 8 měsíci +1

    Thanks for sharing, looking at this unit

  • @LivingFree4All
    @LivingFree4All Před 8 měsíci +2

    Thanks for showing us. I am on the wall between this unit and Multiplus 5k which is a lot more $. It's the noise I'm concerned about since it would be in house. I love Victron but they are too expensive for me. I see Connective has a delay on them now on back order

    • @NoBSBatteries
      @NoBSBatteries  Před 8 měsíci

      It does spool up under load and while charging with solar. Quieter than the 6000EX it replaced.

  • @jdell6250
    @jdell6250 Před 8 měsíci

    Will you be hooking the 6000XP to your main electrical panel for AC input? If so what is the breaker size?

    • @notoshaapproved
      @notoshaapproved Před 8 měsíci

      Not on this build but a double pole 30 would be appropriate.

  • @kkz2dgz
    @kkz2dgz Před 6 měsíci

    I know just enough to not know anything .......Im building a 8.5' x 22' travel trailer I have 48 @230 ah cells, my BMS is JK-B2A24S20.....was building three 48v batteries with 3 seperate BMS ..... going to have 12 panels on roof @385w each.... Everyone is telling me to go Victron Eq.......the all in ones inverters look so much simpler but alot of people say they wont work because of the neutral ground bonding.........maybe you could answer all my questions because I have gotten alot of mis information on this whole all in one in a mobile setting......If I use shore power do I need a ground disconnect in my travel trailer to make it work? .....all my loads will be 120v.....no 240v loads ......A/C is 48v.....Just need to clarify some things I dont understand . Any help would be greatly apprieciated !

    • @NoBSBatteries
      @NoBSBatteries  Před 6 měsíci

      As much as I like EG4 stuff, Victron might be a better fit for you. More customizable. MP-II-3000 would probably be a good fit, assuming you have a 30 amp rig. Don't waste your money on the Cerbo. A Raspberry pi and VenusOS is all you need.

    • @kkz2dgz
      @kkz2dgz Před 6 měsíci

      ​I appreciate your opinion.......I went with all top grade materials on everything else.....whats another $5000 for Victron stuff ....lol...Thank You !!

  • @stevedutcher3875
    @stevedutcher3875 Před 7 měsíci

    Is the 6000 xp compatible with a LV 6548 running in split phase?

  • @kkz2dgz
    @kkz2dgz Před 6 měsíci

    Mobile applications?

    • @NoBSBatteries
      @NoBSBatteries  Před 6 měsíci

      There are phone apps for the EG4, Solar assistant, and Home assistant for Android. Not 100% sure if all 3 have apps for IOS.