Whole Home Batteries are Getting More User-Friendly!

SdĂ­let
VloĆŸit
  • čas pƙidĂĄn 15. 06. 2024
  • 🔋 Click HERE to secure your power solution and take the first step towards uninterrupted power supply: [ankerfast.club/uPJCyu]
    #EPro #AnkerSOLIX #EnergyStorage #LIVEINPOWER #AnkerSOLIXF3800
    Electric Pro Academy - Real skills to make real money.
    EPro Masters Beta:
    Take your electrical trades business to the next level with EPro Masters, designed to help electrical business owners build & scale faster through virtual coaching & collaboration. Click here to schedule an interview call: exciting-producer-5962.ck.pag...
    EPRO-2-Call:
    We’ve all been there: You’ve got the tools and the willingness to solve your own electrical problem, but are held up by a couple ominous details. Rather than hiring out the whole project, get 1-on-1 time with an EPro master electrician on a Zoom call here: electric-pro-academy.square.s...
    Products We’d Recommend:
    *EPRO endorses pro-level tools & materials, and receives a small commission for purchases through our links from Amazon & other affiliate programs. We’d be happy to recommend more cost-effective products for DIYers and low-frequency users if you engage with us in the comment section!
    [] EPRO’s Amazon Storefront: www.amazon.com/shop/electricp...
    [] Klein MODbox: www.kleintools.com/modbox
    2020 National Electrical Code (NEC) referenced in our videos:
    Free Access Here: link.nfpa.org/free-access/pub...
    [] Working space requirements [NEC 110.26]
    [] Top Overcurrent Device Under 6’7” [NEC 240.24]
    Synopsis:
    1 box, 1 cord, 1 battery and you’ve got yourself a home backup system that can keep ALL of your appliances, even the 240V ones, running for several hours. A number of companies are beating down the door of home battery systems and we feel Anker has earned a seat at the table with the Anker SOLIX F3800, a system teetering on the edge between portable and permanent energy storage.
    The F3800 is one of the first portable devices to offer 240V power for appliances like ranges, clothes dryers, and EV chargers without an extra parallel battery or magical voltage-combining cable. When connected through a standard generator inlet panel, the F3800 can power 2 240V appliances and 6 120V appliances anywhere in the house
and then just unplug the generator cable and you can still take it for a long weekend camping trip!
    Whether you’re a homeowner looking for a lower cost backup solution or a professional electrician trying to offer your customers a “middle-option” between gas generators and giant battery infrastructures, we think the Anker SOLIX F3800 bridges the gap perfectly.
    Laced within the technical instruction are recommendations and points of professionalism employed daily by Jefferson Electric masters, journeymen, & apprentices.
    If the instruction in this video is unclear or not quite what you’re searching for, feel free to comment below for additional assistance.
    Outline:
    0:00 - Introduction
    0:19 - Anker SOLIX F3800 Unboxing
    1:54 - Home Backup Solution Unboxing
    3:13 - Tools
    3:36 - Identifying Critical Circuits
    6:18 - Removing Panel Cover
    7:25 - Mounting Manual Transfer Switch
    10:40 - Pulling Wire
    14:05 - Installing & Wiring Generator Inlet Plug
    17:01 - Adding a Neutral Bar
    18:46 - Wiring Main Neutral & Ground
    21:37 - Wiring Each Critical Load Circuit
    26:24 - Testing
    Connect With Us:
    Electric Pro Academy is a multimedia team dedicated to training and instructing DIYers and professional electricians for the growth and dignity of the craft nationwide.
    / electricproacademy
    / electricproacademy
    odysee.com/@ElectricPro
    Jefferson Electric installs and services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
    www.jeffersonelectricllc.com/
    / jeffersonelectric
    / jefferson-electric-llc
    Got a question or ideas for a future video? Leave a comment below and submit your idea here: forms.clickup.com/f/23xa9-70/...
    Thank you for watching; we value your feedback and monitor this channel daily.

Komentáƙe • 27

  • @brandonclingaman9227
    @brandonclingaman9227 Pƙed 3 měsĂ­ci +11

    You are not aloud to conceal flex 90’s. 348.42

    • @NIAtoolkit
      @NIAtoolkit Pƙed 3 měsĂ­ci

      It’s not a raceway, it’s a nipple

    • @ernestperino9334
      @ernestperino9334 Pƙed 3 měsĂ­ci +1

      that was a good call i missed that, but they are also not intended to have wire pulled after installation of the cover

    • @ElectricProAcademy
      @ElectricProAcademy  Pƙed 3 měsĂ­ci +8

      Gah, thank you! They only provided one straight connector in the box and I didn't have one on hand. Should have brought one back day 2...
      Thanks for including the code reference and making me better!

    • @95dodgev10
      @95dodgev10 Pƙed 3 měsĂ­ci +4

      Huh.. check it out.. constructive criticism/ correction without being a jack@$$ about it. I'm impressed. Well done.

  • @GS-lh2nx
    @GS-lh2nx Pƙed 3 měsĂ­ci

    I wondered if you could fold wires over to thicken them up to fit better. Thank you.

  • @wm79198
    @wm79198 Pƙed 3 měsĂ­ci +3

    24” and 60%

  • @swisaj
    @swisaj Pƙed 3 měsĂ­ci

    Question- what is typical for final inspection on a residential job. Jumping power from temporary service, using generator power or something else? Thanks for your input.

  • @qwksilver
    @qwksilver Pƙed 3 měsĂ­ci +1

    I really want to see a solution that is UPS for the whole home. Still want solar charging, and battery.

  • @shagofdeath71
    @shagofdeath71 Pƙed 3 měsĂ­ci +1

    what about using a ferrel on the connections which were not holding?

  • @jimdavis6357
    @jimdavis6357 Pƙed 3 měsĂ­ci +1

    I would have used a #10 ferrel on the wire to connect to the plug, not doubling the wire. Makes for a stronger connection .

  • @Kangenpower7
    @Kangenpower7 Pƙed měsĂ­cem

    Even if it is "Legal" to stuff so many wires into that conduit, why? It seems SO easy to put in 2 conduits. And also to put in the wires before putting tightening the 90 degree fitting on the back of the transfer switch. So 8 circuits X 2 wires in each, and a neutral, ground. That is a lot of wire to pull in and not damage it.
    It would be just as easy to put the two conduits on the back of the transfer switch,, with all of the wires going through the conduits, and then with the two holes in the bottom of the panel, pull the wires into the panel as you attach the transfer switch to the wall, then attach the lockwashers to the conduits. Then put on a bushing.
    Way to go, put a tap through the wall! And drill 2" behind the electrical panel, when you are tapping the electric panel to put in the ground screw on your new ground bussbar. Maybe it would be better to drill the hole, and then use a hand tap that is only going to go about 1/2" behind the electric panel?
    I always cringe when I see someone with a saw near a electrical panel. If you use a large flathead screwdriver to knock out the drywall, then you are far less likely to ever cut a wire that might be located behind that drywall. Once you have a 2" or so diameter hole, then you can feel for wires, water lines, and other things, then use the saw all you want! Yes I know that you say a hand saw is going to detect the wires as you cut into them, and you are smart enough to feel the electrical wire, yet most do not have the talent that you have at detecting when you are sawing into a electric wire.
    This video is very educational. Thanks for making it.

  • @MrKen59
    @MrKen59 Pƙed 3 měsĂ­ci

    I want one ❀

  • @irfanwaseh
    @irfanwaseh Pƙed 3 měsĂ­ci +1

    What about ferrules

  • @slip0n0fall
    @slip0n0fall Pƙed 3 měsĂ­ci

    Joel really itching to find a similarly sized solution, BUT, that can pass-through that 240 service. That way no intervention (manual transfer) neccessary. Any leads?

    • @Kangenpower7
      @Kangenpower7 Pƙed měsĂ­cem

      It sounds like you want a automatic transfer switch. For a 200 amp ATS, that is about $600 - $ 1,200. Plus installation. Are you really sure you want a automatic transfer switch?

    • @slip0n0fall
      @slip0n0fall Pƙed měsĂ­cem

      @@Kangenpower7 no what I'm looking for is more like a grid-interactive inverter, which essentially acts as a whole house UPS. The of course exist, but not in portable form factor like this

  • @JMjayesim
    @JMjayesim Pƙed 3 měsĂ­ci +1

    13:52 ah yes the wonderful banana milkshake

  • @BrynvanNuissenburg
    @BrynvanNuissenburg Pƙed 3 měsĂ­ci

    00:01🔋 Whole home batteries are becoming more user-friendly, offering simple setup processes and clear instructions.
    01:15🏕 Portable battery units are now designed with features like ball bearing wheels, making them suitable for outdoor use such as camping.
    02:09⚡ Anchor offers a simple home backup solution with a generator cord and manual transfer switch for easy power management during outages.
    03:12🔧 Tools needed for installation include a drill, screwdriver, and wire stripper cutters, along with basic circuit identification skills.
    04:21🏠 Circuit identification is crucial for selecting which circuits to power during outages, ensuring essential loads remain functional.
    08:16 🛠 Installation may require modifications for wire length and conduit positioning, ensuring a proper fit and safe electrical connections.
    14:18 ⚙ Careful attention to detail is necessary during terminal installation, including proper wire stripping and torque settings to avoid loose connections.
    20:45 💡 Working on electrical systems requires caution and attention to detail, as small errors can lead to significant safety hazards.
    22:41 📏 Proper wiring sequence and attention to detail are essential when connecting circuits to breakers to ensure safe and efficient operation.
    23:52 🔧 Use appropriate tools like a number one and number two square drive for electrical work to prevent stripping and ensure secure connections.
    24:20 🔌 Properly cut, strip, and secure conductors using wire nuts for reliable connections.
    25:31 💡 Consider panel upgrades for safety and efficiency, especially if breakers show signs of wear or if conductor bundling becomes an issue.
    26:47 ⚡ Transitioning from shore power to battery power involves securely connecting the power cord and switching circuits to ensure uninterrupted power supply.
    27:02 🔋 Monitor power output and transition critical circuits to battery power during outages for continued functionality of essential appliances.
    28:04 🛠 An easy-to-use manual transfer switch allows for seamless transitions between battery power and shore power, ensuring convenience and reliability during power outages.

  • @priceandpride
    @priceandpride Pƙed 3 měsĂ­ci

    Dope

  • @chrisleslie1988
    @chrisleslie1988 Pƙed 3 měsĂ­ci

    Well
 I’m kinda confused. You call Phillips by the creator, which I could call a x or cross.
    But when it comes to the nicer, better Canadian screw head, you guys call it square vs Robbie/robertsons. Why? Just a general thing to say no Canada it’s not called that. Lol

  • @highryder100
    @highryder100 Pƙed 3 měsĂ­ci

    Am i mistaken?, adding ground bar is no big deal. Adding a neutral bar I thought was not allowed- wouldn’t you need to have a more reliable connection than a screw into the case of panel- maybe a conductor not smaller than the total load that could be pulled connected to the main neutral bar. Not bashing your work- genuinely proposing the question as iv had similar issues on past jobs

    • @highryder100
      @highryder100 Pƙed 3 měsĂ­ci

      My solution has been to add a ground bar, then move grounds to it which freed up slots for my new neutrals

    • @Kangenpower7
      @Kangenpower7 Pƙed měsĂ­cem

      It is acceptable to install a second or third neutral bussbar. They do need to have a large wire connecting them. I thought that they did put in a large wire between the new and old bussbars. I would think if the incoming #4 wire is used for a 100 amp service, then that size would connect to each bussbar. If #0 incoming, then #0 for each bussbar.

  • @michaeljavert4635
    @michaeljavert4635 Pƙed 3 měsĂ­ci

    Karma is like a chameleon. It comes and goes. And I never get what I want. But I always get more than I deserve. And not what I truly deserve. Bad things is what I get, and more than my fair share. Oy vey. Also, when my drill bits get like that, I buy identical bits, then use the receipt for the new bits, to return the ones that are screwed up, because there's no excuse for that. Companies are deliberately making things chintzy, so they can pay for it. Maybe sooner or later they'll get a clue and stop selling chintzy things so that customers that choose them will have a quality product.
    As for the wire nuts, I don't like twisting nuts. I use Wago lever nuts and secure with electrical tape. Courtesy credit to Everyday Home Repairs.

  • @ElectroAtletico
    @ElectroAtletico Pƙed 3 měsĂ­ci +2

    Question: Do I want a "battery-powered house"?
    Answer: No.