Indirect Water Heater Replacement

Sdílet
Vložit
  • čas přidán 6. 09. 2024

Komentáře • 22

  • @MiHeatingGuy
    @MiHeatingGuy  Před rokem +1

    Help Support My Son Logan To Beat His Cancer.
    Go Fund Me
    gofund.me/9deb66a2
    Venmo & Zelle. jfeger4@att.net

  • @MikeyDee.
    @MikeyDee. Před 3 měsíci +1

    Mine was new in 7/2021. Replaced again in 3/2023. Leaking again same as yours for a third time, 5/2024!

    • @MiHeatingGuy
      @MiHeatingGuy  Před 3 měsíci +2

      They don't make them like they used to. These used to be the best tanks around but I don't use them anymore. I use the superstore tanks by triangle tube

    • @MikeyDee.
      @MikeyDee. Před 3 měsíci

      The original tank was installed 11/2001, fyi.

  • @ajfabian82
    @ajfabian82 Před 5 měsíci +1

    Unions, a shop vacuum and a level would prove to be useful tools on return jobs, especially if your the guy going back….

  • @richardcote9663
    @richardcote9663 Před 29 dny +1

    Solder joints at the top???? Could be the heat during install. The new ones have a huge red warning sign to not apply heat to fittings.

    • @MiHeatingGuy
      @MiHeatingGuy  Před 29 dny

      no i used press fittings

    • @richardcote9663
      @richardcote9663 Před 29 dny

      @@MiHeatingGuy I just took delivery of this same model under warranty. It’s replacing my original one of 24 years that is just starting to leak at the outer shell casing. Sadly I don’t think this one will last anywhere near 20 years. Time will tell. I think I better install it with quick disconnects in case it fails much sooner than later. Lots of labor in repiping it all.

  • @utubepro7742
    @utubepro7742 Před rokem +4

    Totally agree with newer AMTROL
    JUST RELACES ONE TWICE
    WITHIN 3-4 years too
    Now he’s got HTP

  • @tonydelgrego2906
    @tonydelgrego2906 Před rokem +3

    I had one leak from the top,bottom and the side. This was replaced under warranty three times at the same house.

  • @joeanglin2849
    @joeanglin2849 Před rokem +1

    Cutoffs are golden 😊

  • @phaedrus2633
    @phaedrus2633 Před rokem +1

    I do miss the old time plumbers, getting the joint perfectly hot, touching the solder stick, and just watching the joint suck up the solder. No, come to think of it, watching them, after trying it myself many times, they just ticked me off. I did like watching someone who was good at it though. I was doing some phone work on the second floor of Bldg. 140 on Selfridge, and a plumber was installing a boiler system. He was good.

  • @joekind1
    @joekind1 Před 6 měsíci

    You didn't go into detail for connecting the low voltage wires.

  • @alexg3855
    @alexg3855 Před rokem +1

    SSU45 is gold

  • @timothyfink9354
    @timothyfink9354 Před rokem +1

    nice job done.

  • @picklerix6162
    @picklerix6162 Před rokem +3

    What are the chances that the manufacturer actually fixed the cause of this issue?

  • @NoJokeSnoke
    @NoJokeSnoke Před rokem +1

    Great job as always! That plastic thermo bracket is still haunting me. Painful. lol

  • @chrissipple1018
    @chrissipple1018 Před rokem +2

    Speaking of camera work I had to stop watching until I took some Dramamine I got sea sickness, just kidding. I'm stupid HVAC tech from Southern California as far as I know no one out here does boiler work. I was just wondering is that a heat exchanger for domestic hot water and air heating. Just asking put more videos out there, always great. Thanks

  • @billhill839
    @billhill839 Před 24 dny +1

    Do you grow a scraggly beard to make up for being bald? Just curious.