How To Install Ductless System! Daikin R32 Ductless Inverter Installation and Procedures! A2L

Sdílet
Vložit
  • čas přidán 16. 07. 2023
  • Thanks for watching! I hope you enjoyed. Please leave any thoughts, feedback, comments, criticism, or advice in the comment section. Thumbs up, and subscribe to see more content!
    Like my videos? Check out and consider subscribing to:
    Below are links to my most important tools that I carry daily, and links to reach me through different methods of social media!
    My Tools and Tool Bag:
    amzn.to/3CUM6rI
    Other HVAC Tools I keep in my Van!
    amzn.to/44sqgYl
    Venmo:
    venmo.com/DCHVAC
    Follow me on Instagram:
    @dc.hvacr. invitescon...
    Follow me on TikTok:
    www.tiktok.com/t/ZTdv7DK3D/
    Need to get in touch? Email me at dchvac123@gmail.com

Komentáře • 159

  • @JoePublic717
    @JoePublic717 Před rokem +4

    Dude, no sense to fall off that ladder being Superman. Mike has to get you something to hoist it up there. Maybe put a towel around it and push it up? You guys did a great job, just be careful.

    • @DCHVAC
      @DCHVAC  Před rokem +2

      The way I did it was not necessary. I wanted to have a little fun in the day and I really enjoyed it.
      I could have brought it through the window.

  • @Eddy63
    @Eddy63 Před rokem +9

    I'm sure I speak for Mikey and our viewers , you guy's are awesome and have grew up right in front of our eyes ... We are proud of your success in the field ... Thx

  • @thomaschatham9971
    @thomaschatham9971 Před rokem +4

    Excellent install and video. Mikey did good when he hired you young man. Kudos to Peter as well.

  • @tobycurtis6030
    @tobycurtis6030 Před 6 měsíci +1

    It's crazy I am a plumber in AZ we do strictly plumbing domestic supply and dwv. You guys on the east coast have to know it all. You're knowledge is so much more superior than mine. It's humbling watching your videos.

    • @DCHVAC
      @DCHVAC  Před 6 měsíci

      Thanks for sharing

  • @eddiew.6485
    @eddiew.6485 Před rokem +5

    Nice job as always, Daniel!

  • @Jjustice4all253
    @Jjustice4all253 Před rokem +5

    Great job Daniel and Peter. It’s nice to see talented technicians who care.

    • @DCHVAC
      @DCHVAC  Před rokem

      Thank you!

    • @joeweatlu5169
      @joeweatlu5169 Před rokem +2

      Now if they'd just learn to work safely that would be great. Is the boss ok with the way you carried that unit up the ladder?

    • @DCHVAC
      @DCHVAC  Před rokem

      no

  • @biggusbestus551
    @biggusbestus551 Před rokem +3

    Great job ! Ladder idea not so much ...

  • @gaylonrose6713
    @gaylonrose6713 Před rokem +1

    Nice job you two

  • @CT-vm4gf
    @CT-vm4gf Před 11 měsíci +1

    Great job boys.

  • @anthonylange439
    @anthonylange439 Před rokem +2

    I always use nylog blue on my flare joints! Also I’m glad you are thinking about getting away from the staybrite 8 braze is the way to go… can’t trust that stuff with pressures of refrigerant and it’s just more tedious b/c you have to prep it like solder

  • @scottgambers8013
    @scottgambers8013 Před rokem +8

    Nice job but you need to let Peter help so he can learn. Most people learn better by doing.

    • @DCHVAC
      @DCHVAC  Před rokem +3

      He’s doing great the way he is. Remember this is my career…. I only record so few service calls.

  • @eldoradoboy
    @eldoradoboy Před rokem +1

    Chigo built original unit... still have 2 of those remaining in my house (under the grunaire name).. from 2008.. i can bet the pipe near the compresser discharge cracked... soon to be one left standing in my house.. I had 3.. 2 still work but one started leaking a slow leak so a Fujitsu is on order for it.. whyd you guys stop doing fujitsu? id be an upset customer if I got a daikin isntead of a fuji.. Daikin VRV is top notch but their single zone mini's im not a huge fan.. Fuji anyday.. Nevertheless regardless of the unit.. your guys' Install is Top notch!! way to go!

  • @FB-111A
    @FB-111A Před rokem +1

    Another great video. Thanks for sharing

  • @rickblot1547
    @rickblot1547 Před rokem +2

    Awesome install!
    Thanks for the great videos, Danny!
    God Bless!

    • @DCHVAC
      @DCHVAC  Před rokem +1

      Thank you, God bless you too!

  • @jenko701
    @jenko701 Před rokem +1

    Nice job .

  • @TofuInc
    @TofuInc Před rokem +4

    Glad to see more R32 being installed. Looking forward to it being available with the larger units. 👍

  • @1022hard
    @1022hard Před rokem +4

    We were told it was recommended to add a little vacuum pump oil to the flare thread before attempting to tighten the fitting. The tools you’re using are awesome!

    • @DCHVAC
      @DCHVAC  Před rokem +1

      I was always told vacuum pump oil should only be used for Vaccuum pumps, as it’s not save for refrigerant systems.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Před rokem +2

      @@DCHVAC just use oil. You’re only using a half a drop for lubrication for improved flare forming. I’m sure you’re not going to dilute the system oil charge that much.

    • @user-ln7of9gs4s
      @user-ln7of9gs4s Před rokem +1

      Nylog? They recommend that.

    • @DCHVAC
      @DCHVAC  Před rokem

      the issue is vacuum pump oil sits on truvks and picks up miniscule amounts of moisture being opened and clsoed. when thats mixed with POE oil that minute amoount of moisture creates acid and ive seen the destruction moisture has done to the refrigerant system.

    • @user-ln7of9gs4s
      @user-ln7of9gs4s Před rokem

      @@DCHVAC but, if you use vacuum pump oil when seating the flares and then pull a vacuum, wouldn’t the excess oil/moisture be sucked out of the system? Is this where Nylog would out perform and do better? Please explain. I’m not an hvac expert, I like following and learning, understanding. My other question, if you used POE oil that was opened and closed, wouldn’t you have the same issue as vacuum pump oil?

  • @slip0n0fall
    @slip0n0fall Před rokem +1

    Helps to cycle those valves a couple times during evac, they'll actually trap a little air in the ball

  • @Can_non69
    @Can_non69 Před rokem +1

    That's nice and tight. You're a very skilled tec.

  • @fatcat-hc4pj
    @fatcat-hc4pj Před rokem +1

    Nice job guys

  • @baratono
    @baratono Před rokem +8

    You two always do nice clean work! BTW, according to it's technical data sheet, Nylog Blue is compatible w. R32 refrigerant.

    • @DCHVAC
      @DCHVAC  Před rokem +1

      Awesome Thanks! I’ll be using it in the future as a lubricant on the threads for more torque before friction, and the bottom side of the flair to prevent spinning.

    • @giorgosktoridis903
      @giorgosktoridis903 Před rokem

      Yes its compatible but if you are using that torque wrench maybe you have to apply more torque than usual

  • @joeconnett8112
    @joeconnett8112 Před rokem +1

    Dynamic Duo.

  • @bitpro8903
    @bitpro8903 Před rokem +1

    Nice job

  • @storyoflife9649
    @storyoflife9649 Před 6 hodinami

    Good job

  • @petersmart1999
    @petersmart1999 Před rokem +1

    Get yourself some strain relief connectors for your com wire,they are cheap and much better than just sticking the wire through that hole.

  • @timsky99
    @timsky99 Před rokem +3

    Without oiling the flares, eventually they'll leak, I always cut them off and braze them. Also, carrying the unit up the ladder like that is not good...one day you'll either drop it or do your back in. Just hire a genie lift and do it safely :)

    • @DCHVAC
      @DCHVAC  Před rokem

      A good flare shouldn’t leak if torqued properly, that’s what the torque spec is for…
      However if you want to get technical any mechanical seal leaks minutely at all times just not enough to make an impact.

    • @timsky99
      @timsky99 Před rokem

      @@DCHVAC so why do you use nylog then then? You weren't sure if it was compatible with R32 so you squeaked them on. Using oil is ancient tech, but so is the wheel.

    • @DCHVAC
      @DCHVAC  Před rokem

      i use nylog on the threads itself as a lubricant to be able to tighten it more freely, and prior to working for pipe doctor i hadnt used torque wrenches, so a little nylog on the back side of the fare where the nut presses prevented spinning and ripping the flare when overtightening

    • @timsky99
      @timsky99 Před rokem

      @@DCHVAC That's my point, you didn't spend 30 secs looking up on the internet if it was compatible with R32 and made all your flares dry....which is why they'll eventually leak and you probably twisted the pipe when you torqued them up. It was a nice looking job, i'm not saying you don't take pride in your work, but the little things add up over time....like one day you'll drop a unit carrying it up a ladder...you wouldn't get away with that working for me and I reckon if you think about it, it's probably not something you should be doing.

  • @Ed-sh8jt
    @Ed-sh8jt Před rokem +1

    Consider installing a plastic pipe in the wall for pipes to pass thru. Cause spiders or scorpions or other bugs could pass thru interwall and come into room behind AC.

  • @HVAC_Unknown
    @HVAC_Unknown Před rokem +3

    They put a leak lock on the face of the flare !!!
    No wonder it leaked😂

  • @Wayman_Simmang
    @Wayman_Simmang Před rokem +1

    God job

  • @bruceelias2732
    @bruceelias2732 Před rokem +1

    Hi Daniel!!

  • @petersmart1999
    @petersmart1999 Před rokem +2

    ASHRAE STD 97 passes testing for Nylog woth R32

  • @napiang7805
    @napiang7805 Před rokem +1

    Daddzy your just hamdsome

  • @maracservices
    @maracservices Před rokem +1

    Nice channel mate. Keep up the good work! Also, how good are the magnets on that little Milwaukee spirit level haha. I bought that level and Im so happy with it..

    • @DCHVAC
      @DCHVAC  Před rokem

      Love the magnets, amazing. Thanks

  • @nicholaslance1569
    @nicholaslance1569 Před rokem +2

    Nice install! one quick question I was just wondering if the staybrite 8 joints you had leak were joints between a swaged connection or if they were joints from like the lineset and a manufactured fitting. I have used it a few times and I felt it was very intolerant of gaps that would be no issue at all with brazing .

    • @DCHVAC
      @DCHVAC  Před rokem

      They were joints at filter driers, and at unit connections. We just braze now, staybrite 8 works for some people just not for me.

  • @TheRossz
    @TheRossz Před 11 měsíci

    In case of split ACs you should leave at least 10 cm / 4 inch space between ceiling and indoor unit, and 10-15 cm / 4 to 6 inches space between wall and outdoor unit. :*

    • @DCHVAC
      @DCHVAC  Před 11 měsíci

      Manual specified less than 2” is acceptable.

  • @jphilbin528
    @jphilbin528 Před rokem +1

    Good videe, great install…you’d love a digital adjustable torque wrench

    • @DCHVAC
      @DCHVAC  Před rokem

      I’ve been looking into the hilmor

    • @jphilbin528
      @jphilbin528 Před rokem +1

      @@DCHVAC that or the Yellow Jacket- either won’t let you down…. The YJ is a little shorter for tight spots….

  • @mattl643
    @mattl643 Před rokem +3

    Hopefully when the time comes you'll get the other three replacement installs. Nice job as always.

  • @xlostf8x348
    @xlostf8x348 Před rokem +1

    R32 is finally here eh.

  • @billhollin6206
    @billhollin6206 Před rokem +6

    Thanks for carrying unit up ladder. I can show my guys what not to do. Don’t do that again. You’re too valuable to loose. Scare your parents another way. Nice job. Keep it up.

    • @DCHVAC
      @DCHVAC  Před rokem

      Lol, I still think it was epic.

    • @JohnBGood-kq3ul
      @JohnBGood-kq3ul Před rokem +4

      @@DCHVAC I'm not a/c guy, but I've spent over 40 years working on ladders. One of the most important safety rules when climbing is *_3-point contact_* all the time. Now I'll be the first to admit I don't always follow that rule, but I'd never pull a stunt like trying to carry a 90 lb bulky item up that ladder. That's just asking for serious injury. Please be careful.

    • @clarehayden8314
      @clarehayden8314 Před rokem

      I've told him that was a bad decision.

    • @JohnBGood-kq3ul
      @JohnBGood-kq3ul Před rokem +1

      @@clarehayden8314 Appears to be a good tech, just a little too cocky for his own good. Safety is not something to play around with.

    • @billhollin6206
      @billhollin6206 Před rokem +1

      @@clarehayden8314 this made our safety meeting this morning. Daniel, consider yourself written up, and we’d get appropriate lift for you. I was your age 50 years ago 😀

  • @chuckquinn8026
    @chuckquinn8026 Před rokem +2

    Another beautiful job by the brothers 👍👍. Do you now need another set of gauges and hoses for this refrigerant Daniel?

    • @DCHVAC
      @DCHVAC  Před rokem +1

      Yes, already bought a lightly used set of testos from a subscriber

  • @unknownvalor9755
    @unknownvalor9755 Před rokem +1

    2:57 hey Daniel ever notice the gasket material filling the hole for the communication wire is the same stuff on the nipple.

    • @DCHVAC
      @DCHVAC  Před rokem

      Defiantly not the same material. The nipple had a tacky opaque gray substance on it. The wiring had a hardened gelatinous translucent t gray/tan substance.

  • @giovannicampanelli8524
    @giovannicampanelli8524 Před rokem +2

    You are a beast carrying that unit up all by yourself!!! Mikey Pipes can you do that? Or is Daniel a younger version of you!!!

  • @harryvelez489
    @harryvelez489 Před rokem +1

    The room thing, small for the air conditioner I would you shape window unit 8,000-btu and call it a day

    • @DCHVAC
      @DCHVAC  Před rokem

      Hey leave doors open, the air drafts downstairs, they wanted a direct replacement regardless.

  • @giorgosktoridis903
    @giorgosktoridis903 Před rokem +1

    Its funny because when i commented on that solder you used that it seems to be weak on Mikeys channel he said that its safe to use.I don't know what regulations you have in the US but here in europe when using r410a lines must be tested at 42 bars equals to 609 psi.

    • @DCHVAC
      @DCHVAC  Před rokem

      It’s more of a vibration and expansion/contraction issue than pressure. Sheer pressure it’s rated much higher than a brazed joint.

  • @mikev.1034
    @mikev.1034 Před rokem +1

    👍👍

  • @ramanelectronic5845
    @ramanelectronic5845 Před 4 měsíci

    Nic

  • @nbctcp3450
    @nbctcp3450 Před 3 měsíci

    1. 16:20 what app u used for decay test
    2. what temperature and fan speed u set in remote when u check manifold pressure
    example lowest temp and max fan speed

    • @DCHVAC
      @DCHVAC  Před 3 měsíci

      Doesn’t matter what temp u set remote that doesn’t change anything. And max fan speed.

    • @DCHVAC
      @DCHVAC  Před 3 měsíci

      I have the BlueVac+ Pro micron gauge with the true blue hose kit they have a proprietary app.

    • @nbctcp3450
      @nbctcp3450 Před 3 měsíci

      @@DCHVAC in my test lowest temp or max fan speed will give highet ampere and psi

  • @Ed123
    @Ed123 Před rokem +1

    Can you mount indoor unit that close to the ceiling?

    • @DCHVAC
      @DCHVAC  Před rokem

      Clearance is 2 inches specified in the manual, I am well above. Closer to 4 or 5

    • @Ed123
      @Ed123 Před rokem +1

      @@DCHVAC Thanks for the answer. I have seen somewhere comment that required distance is 8 inches.

  • @sunbeam8866
    @sunbeam8866 Před rokem +1

    Aside from the pros & cons of these ductless systems vs window units, HOAs and some local zoning regulations already prohibit window units - supposedly because they're unsightly. Are you aware of any restrictions on these ductless units?

    • @DCHVAC
      @DCHVAC  Před rokem

      Never heard or seen any.

  • @ramziddinxurramov6068

    Hello. Value 808 mis fspin 300 what to choose?

  • @SombraLocs
    @SombraLocs Před 6 měsíci +1

    What is that drain hose that you use?

    • @DCHVAC
      @DCHVAC  Před 6 měsíci

      Just corrogated tubing

  • @mohsenpanahi6773
    @mohsenpanahi6773 Před rokem +1

    8:19 You need to find wider ladder.

  • @picklerix6162
    @picklerix6162 Před rokem +1

    I love StayBrite 8. You have to get the pipe connections clean and use the flux sparingly. Also, you don’t want any large gaps because the solder flows thin and has trouble filling the gaps. In my opinion, StayBrite 8 is easier to use than silver brazing rod and makes very reliable connections. I installed my HVAC equipment in 2020 using StayBrite 8 and absolutely no leaks so far.

    • @TofuInc
      @TofuInc Před rokem

      Yup, soldering is a different animal than brazing. If you attempt to fill any gaps with solder it will crack.

    • @DCHVAC
      @DCHVAC  Před rokem

      I think staybrite 8 has its purposes. But I stand by brazing at this point.

  • @tphvac87
    @tphvac87 Před rokem +1

    What’s the minimum line set length on those units?

  • @josephgraham1065
    @josephgraham1065 Před rokem +1

    Just curious doesn't Daikin make a 9k unit that runs on 115? Great install

    • @DCHVAC
      @DCHVAC  Před rokem

      Not sure, wouldn’t install it.

    • @josephgraham1065
      @josephgraham1065 Před rokem

      @@DCHVAC I agree without a disconnect but have seen many mini split installed using 115

    • @DCHVAC
      @DCHVAC  Před rokem

      id never install anything thats 115, its cheap garbage at that point and you take a big hit on effeciency

  • @DJSephEntertainment
    @DJSephEntertainment Před 7 měsíci

    What is the electrical requirements for a ductless system like this?

    • @DCHVAC
      @DCHVAC  Před 7 měsíci

      Depends on the unit, some cheaper models are 120v, but the more efficient and better built units are 240v

  • @user-ln7of9gs4s
    @user-ln7of9gs4s Před rokem +1

    Can you use Staybright 8 instead of using the flares or brazing? And would you not have to use nitrogen? Different question I know…*just finished watching* I see you would not recommend it after all.

    • @DCHVAC
      @DCHVAC  Před rokem

      We use the flares, manufactures do not allow other connections to be made.

  • @veronicacampbell9197
    @veronicacampbell9197 Před rokem +1

    First 😊

  • @johnmiller102
    @johnmiller102 Před rokem

    What is the minimum line set length on that unit? I did an LG and they wanted at least 9 feet I think. Mitsubishi doesn't have a minimum. I think Daikin is the same as LG. Good job guys. It good to see young guys out there doing good work!

    • @DCHVAC
      @DCHVAC  Před rokem

      11 ft. Dead on with this one, maybe an inch or two longer or shorter

    • @user-ln7of9gs4s
      @user-ln7of9gs4s Před rokem +1

      @@DCHVACdoes it matter or is that a made up number? Everything is the same concept, so I’m not sure why one would require a minimum length.

    • @DCHVAC
      @DCHVAC  Před rokem

      it matters a great deal for the life of the compressor with oil return and with liquid refrigerant making its way back to the compressor. SUPER Super important

    • @johnmiller102
      @johnmiller102 Před rokem

      @@DCHVAC So would you put a loop in the line set behind the OD unit to have enough length if there wouldn't be otherwise? Would a loop cause a problem with oil not returning to the compressor?

    • @DCHVAC
      @DCHVAC  Před rokem

      @@johnmiller102 manufacturers recommend putting the loop in.

  • @VinceCuzmono
    @VinceCuzmono Před rokem +3

    Nylog should be fine, 410 is made up of r32 & r125.

  • @jeffw2338
    @jeffw2338 Před rokem +1

    Nylog should be fine with R32 because R410a is 50% R32.

  • @RSBot2jar
    @RSBot2jar Před rokem +1

    The sealant looks like leaklock to me.

  • @Silky_boi
    @Silky_boi Před rokem +1

    For Staybrite8 I only use it on the evap coil, I just feel there’s far too much pressure and vibrations going on with the condenser side, so I always have brazing done there. Otherwise I’ve been using it for about 3 years now and have had no leaks.

    • @TofuInc
      @TofuInc Před rokem

      Oldest unit I used StayBrite 8 on was in 2010 on both the evap and the condenser. It's still going and never had a leak.

    • @DCHVAC
      @DCHVAC  Před rokem

      I think the vibrations, and expansion and contraction are what kill the joints.

    • @Balticblue93
      @Balticblue93 Před rokem

      @@TofuInc StayBrite 8 cannot handle the pressures and keep a leak free seal. Nobody uses that product on 410a or newer systems. Even on an evaporator, you will end up leaking. I don't know of a single HVAC company using that product anymore. Sil-fos 8 is pretty much the main product besides press fit systems.

    • @TofuInc
      @TofuInc Před rokem

      @@Balticblue93 I've seen it used more in the past couple years than ever before. It wouldn't be my first choice but I think it's a lot stronger than people give it credit. The joints have to be clean and tight. I personally have done some joints with it that seen over 900psi. I don't think pressure is the issue with it.

  • @balint133
    @balint133 Před rokem +1

    couldn't you installed both units at the same height? It looks really crap that one's higher than the other, it'd really bother me if this would be on my house...

    • @DCHVAC
      @DCHVAC  Před rokem +1

      They’re different sized units, and we will be replacing the other unit in due time.
      I mounted it where I did in order to cover up the holes from the old bracket, and reuse the holes already drilled into the house.
      Regardless, the customer doesn’t care, they’re very old.

    • @balint133
      @balint133 Před rokem +2

      @@DCHVAC gottcha, really clean install I knew there must've been a reason.

  • @Wintersky136
    @Wintersky136 Před rokem +1

    11:29 no nylog?

  • @mohsenpanahi6773
    @mohsenpanahi6773 Před rokem +1

    Are you the one who worked with Mikey Pipe?

    • @DCHVAC
      @DCHVAC  Před rokem +1

      I currently work for Mikey pipes.

    • @mohsenpanahi6773
      @mohsenpanahi6773 Před rokem +1

      @@DCHVAC I thought you became someone for yourself.😅

  • @bohanger6315
    @bohanger6315 Před rokem +2

    Rent a material lift, way cheaper than workmans comp and being out of commission. Hate being the employee in those positions.

    • @DCHVAC
      @DCHVAC  Před rokem +1

      I had many options to get it up there, I chose this one to have a little fun in the day and scare my family who watches. If I had any doubt of capability (if that even matters) I would’ve done it another way

    • @JohnBGood-kq3ul
      @JohnBGood-kq3ul Před rokem +1

      @@DCHVAC That's the same attitude that workers with serious permanent injuries had. Falling off a ladder is not fun.
      Better hope OSHA or Mike's Workers Comp insurer doesn't see this video. Mike might have some 'splaining to do.

  • @Trainman0401
    @Trainman0401 Před rokem +1

    Use a safety cord. You are too confident on that roof and ladder. That’s when accidents happen.

  • @bestfriendhank1424
    @bestfriendhank1424 Před 7 měsíci +1

    Never ever grow a mustache again

  • @arashzergan3741
    @arashzergan3741 Před rokem +1

    Are you name is peteer mikey paipes enginer

    • @DCHVAC
      @DCHVAC  Před rokem +2

      My name is Daniel, Peter is my younger brother and mikes apprentice

    • @arashzergan3741
      @arashzergan3741 Před rokem +1

      @@DCHVAC ok❤

  • @trent624
    @trent624 Před rokem +1

    Go back with a 410 unit. Why are we installing r32. Great bud btw !

    • @Joshuatimmons1783
      @Joshuatimmons1783 Před rokem

      410 is better than r32 at least for now because most places you can’t get r32 I ran into that issue last week I had to put in an r32 unit and needed to add refrigerant because of the lineset length couldn’t find r32 anywhere locally and I told the customer I can’t start it up until I get the refrigerant which I had to order online and wait 2 weeks for it to come

    • @DCHVAC
      @DCHVAC  Před rokem +2

      We have a stock of R32, we’re installing them because that’s the next priority residential refrigerant. We’re getting ahead of the curve.

    • @Joshuatimmons1783
      @Joshuatimmons1783 Před rokem

      @@DCHVAC I would do the same if I could get the refrigerant locally I can’t even get it to stockpile it because all of the local distributors are saying they are unable to get it

    • @DCHVAC
      @DCHVAC  Před rokem

      theres been back and forth with manufacturing due to the laws tryng to be changed by the EPA. they wanted to mandate all new refrigerant be sold in reusable recovery cylinders, but the law was struck down by congress. the tank we have is in a reusable cylinder but im not sure what will end up being the norm...

  • @stevesolt4036
    @stevesolt4036 Před rokem +2

    Need to come up with better way than one person bringing u it up ladder. Violates all ladder safety.

  • @TheJessikitten
    @TheJessikitten Před rokem +1

    The por old ac😢🤬🤬🤬

  • @eddiew.6485
    @eddiew.6485 Před rokem +2

    That makes me #2💩