HPLC TROUBLESHOOTING | COLUMN CLOGGING | VOICE OF KAYANI

Sdílet
Vložit
  • čas přidán 20. 06. 2024
  • HPLC TROUBLESHOOTING | COLUMN CLOGGING | VOICE OF KAYANI
    In this video explained two Mai causes behind higher pressure in HPLC analysis.
    this video is very important because 2nd issue is very important than 1st issue.
    so watch the video till end because it's is routine problem in HPLC analysis which is faced by HPLC analyst.
    your quires;
    HPLC
    HPLC troubleshooting
    troubleshooting
    trouble
    shooting
    why pressure higher in HPLC
    HPLC column blockage
    HPLC column clogging
    column
    blockage
    clogging
    clogged
    clogg
    column clogging
    pressure
    contamination
    interview questions
    QC interview questions answers
    interview
    question
    answer
    chromatography
    #voiceofkayani
    ______________________________________________
    #hplc #chromatography #troubleshooting
    #interviewquestions
    ______________________________________________
    follow on Instagram;
    / safdarkhankayani
    like us on Facebook;
    safdar.khank...
    subscribe for more videos;
    / @voiceofkayani5419
    linkdin;
    www.linkedin.com/help/linkedi...
    email I'd;
    chemist.kayani143@gmail.com

Komentáře • 9

  • @nadeemiqbal4742
    @nadeemiqbal4742 Před 18 dny +1

    Thank you sir.

  • @vasudevsharma-ey6ni
    @vasudevsharma-ey6ni Před 12 dny +1

    Sir theoritical plates ka 25% hone par column use nhi karna chahye .....to sir ye 25% jo hai kya wo column performance ka hai ? Matlb jo hum conditioning ke baad column performance karte hai ......
    Ya fir routine analysis wale products se ?..
    What if a single column is used for different product

    • @voiceofkayani5419
      @voiceofkayani5419  Před 12 dny

      Yes 25% theatrical plate of the initial ho jae on routine analysis to column obsele kar do for better analysis..

    • @voiceofkayani5419
      @voiceofkayani5419  Před 12 dny

      1 column pe sirf 1 product run karo 1 se ziyadha nai

    • @voiceofkayani5419
      @voiceofkayani5419  Před 12 dny

      One column is for one specific product...
      Not more than one different product can be run on one same column

    • @vasudevsharma-ey6ni
      @vasudevsharma-ey6ni Před 12 dny +1

      @@voiceofkayani5419 matlb for example agar koi column pcm ke liye hai to first day of analysis jo theoritical plate thi unse compare karna hai

    • @voiceofkayani5419
      @voiceofkayani5419  Před 11 dny

      @vasudevsharma-ey6ni g han Jo Apne new column pe first analysis Kiya uski Jo theoretical plates aee wo initial count hogi