Firman WHO3242 Generator Natural Gas Conversion-- Dual-Fuel to Tri-Fuel. Completely Reversible.
This video shows how I converted my Firman WHO3242 Dual Fuel generator to also run on natural gas (in addition to gasoline & propane). The conversion required no cutting or drilling so it is completely reversible. I probably could have used this conversion method on any of the Firman WHOxxxx dual-fuel generators, like the WHO3041, WHO3042, WHO2942, WHO3342, or WHO3344.
This video also shows how I added an exhaust extension so that I can safely run the generator locked inside my garage with the exhaust vented outdoors.
Because natural gas has less energy-density than propane, and because the WHO3242's computer is not programmed to automatically turn off the electricity-generating inverter when running on lower-energy natural-gas, I will have to manually make sure that I keep the wattage load below about 2430W (i.e. 81% of its 3000W propane running wattage rating) in order to prevent the engine from running in a bogged-down state. But 2430W should be enough for me to run my refrigerator (370W), gas furnace fan (~400W), 4 laptop PCs (~25W each), Internet modem & router (29W), computer monitors (~27W each), gas-oven (2W), and some other low-power devices like smartphone chargers, LED string lights, etc.
PARTS USED IN THIS VIDEO:
Partzen (Garretson-Impco style) Low Pressure Regulator:
www.amazon.com/gp/product/B09HHB9G9C?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=054451598c1cb561024840a97dc1e3c5&camp=1789&creative=9325
Nash Hose Block Power Valve (3/8” NPT x 3/8" barb):
www.amazon.com/dp/B07BF4HP9Q?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=a45c5a5070e1cf6ab595d497d36cc9b8&camp=1789&creative=9325
5’ of 3/8” Fuel Grade Hose:
www.amazon.com/gp/product/B0BKW2LFCB?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=16c6bebecee8666d290ef00db717f157&camp=1789&creative=9325
3/8” Barbed Tee/Wye:
www.amazon.com/Fittings-Stainless-Clamps-Shaped-Intersection/dp/B07SFYYHX8?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=38eaa8a339b939519b1d74d9c20e65a7&camp=1789&creative=9325
3/8" Hose Barb to 3/8 NPT Fitting:
www.amazon.com/Brass-Fitting-Adapter-CX-WONDERLAND/dp/B09YS1CY7C?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=6e87dcf4bb7cc506c60fdf53a87b8d60&camp=1789&creative=9325
¾” MIP to 3/8” Male Flare fitting (Bought at Ace Hardware):
www.acehardware.com/departments/plumbing/pipe-fittings/brass-fittings/4329777
15’ of 3/8” ID Natural Gas Hose with Quick-Connect Fitting:
www.amazon.com/gp/product/B0BJ1K4XKX?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=fdf9c54aafd4bf3f8fb4fa6bf316f665&camp=1789&creative=9325
Exhaust Extension:
www.amazon.com/dp/B0BLHL8MGY?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=66d2f19d16a55dd7bdd33e552fea7275&camp=1789&creative=9325
Kujunpao Magnetic Dipstick: (Not shown in video but I added this to remove new-engine-break-in metal shavings from oil.)
www.amazon.com/gp/product/B098QFRX79?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=845a78b5afcc202d3ff1f20afa75d23f&camp=1789&creative=9325
Wattage Meter (Not shown in video. I used this to measure the wattage of appliances, but it has a 1650W limit, so it can't be used to measure the output of a fully loaded 2650W generator. It will break above 1650W.):
www.amazon.com/gp/product/B08ZD7YL54?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=212da667025d61939d837cc26fba3785&camp=1789&creative=9325
zhlédnutí: 7 840

Video

Easy Car Visor Upholster Fix Using a Sock, No Sewing, No Glue (1995-2000 Cavalier)
zhlédnutí 208Před rokem
Here's how to quickly, easily, cheaply reupholster/cover/fix a car sun visor using a sock, no sewing, no glue on a 1995-2000 Chevrolet Cavalier. This method should work for similar-style single-attachment-point visors. It's not a perfect, professional job, but it looks plenty good enough for me. I don't think anybody but me will ever notice that it's not the original upholstery.
How to install Williams Fire Sights on Browning Buck Mark Camper UFX.
zhlédnutí 3,5KPřed 6 lety
Williams Fire Sight Model # 70231 for Buckmarks with rear sights longer than 1" (like my Buck Mark Camper UFX). www.amazon.com/Williams-Browning-Buckmark-Fiber-Optic/dp/B0006969Z0?&_encoding=UTF8&tag=daveravevideo-20&linkCode=ur2&linkId=bca5286b4faff88013c40c78546ebdcd&camp=1789&creative=9325 Williams Fire Sight Model # 70232 for Buckmarks with rear sights less than 1" long. www.amazon.com/Will...
How to convert Magpul MOE adjustable-stock to "featureless" tool-adjust fixed stock. Free. No drill.
zhlédnutí 44KPřed 7 lety
This video shows 2 ways to convert your adjustable, Magpul MOE stock to a fixed stock (for "featureless" builds) for free without drilling or marring the MOE stock. The converted stock can then be length-adjusted through the use of a tool. Method 1 Items needed: * A small (preferably black) screw, app 1/4" long by x 1/16" diameter (as measured between the outside edges of the threads). * A smal...
Wasabi eating contest at Mamasake's (Squaw Valley) 04-24-10
zhlédnutí 198Před 11 lety
As you can see from about 1:25 into this video, two of the wasabi-eating contestants found that it's easier to eat wasabi than to digest it. Not for the squeamish. Viewer discretion advised. FYI: In the 1st round, ten contestants ate wasabi rolls. In the 2nd round, the top 6 fastest-eaters, downed tempura-coated wasabi balls. And for the 3rd round (in this video clip) the top 3 contestants gobb...

Komentáře

  • @houstondad2012
    @houstondad2012 Před 15 hodinami

    Well done. Thank you.

  • @jamescook8875
    @jamescook8875 Před 3 dny

    I mocked up the same thing on a champion 4250 dual fuel open frame inverter generator (model 200914). This was for testing so I went ultra budget at the expense of ease of use - no quick disconnects, extra line, splitters, ect... I opted for 20ft of 1/2 gas line 2x female flare (South Bend brand) and a regulator from "Mikatesi" store on Amazon which came with the loadblock and some barb fittings. After that I only required the 3/4 MIP to 1/2 male flare adapter. Like your set up, there is no permanent modification to the generator. The 4250 comes with internal 3/8" propane line so I disconnected the hose via the access cutout in the control panel then just ran it directly to the knock off Amazon regulator's loadblock barb. I connected it to an old 1/2" gas dryer line in the basement and ran it out the window. This was because it provided the easiest access and I didn't want to wrench on my very dated gas meter. It's definitely on the butt end of my house's nat gas line - not ideal. In quick testing it happily managed 2210 watts in eco mode. I didn't have anything readily available to properly ramp up the load so I turned off eco and threw on a 3125 load - it sputtered to an unrecoverable stop despite killing the load early - not surprising. Started right back up without issue. The results were encouraging enough that I'm going to put the effort and expense into testing/refining the set up. Originally I was going to modify my Honda eu3000, however I caught a really good deal on Amazon for the Champion ($325). For $325 generator + $120 in conversion parts I'm in the same ballpark as what it would've cost to convert the Honda, but I have a spare generator and I'm not modifying a $2k machine... For anyone on a tight budget, wait for the Firman refurb sales on Ebay + coupons or Champion deals on Amazon (Prime Day?). If you want to deviate from these specific generator models (Firman WHO3242 or Champion 200914), look up the parts diagram for whatever model you have in mind and see if their propane hose diameter is 3/8" (good) and if there's an internal gas regulator (less ideal) or external detachable regulator (good). Thanks for the inspiration, Dave!

    • @DaveRaveVideo
      @DaveRaveVideo Před dnem

      Interesting information! Thanks for sharing! Happy to hear that my video helped! Yeah... as you probably saw at 23:09 in my video... Just like your experience, when I added a large incremental load (rather than smaller, incremental loads) that pushed my generator somewhat near its limit, it also caused my generator to stall unrecoverably-- even though I quickly removed the load while the engine was still struggling. At $325, you got a heck of a deal on that Champion 200914 (currently ~$600 on Amazon). Let's hope that our efforts were all for naught and we'll never need to use our generators!

  • @steveniemyer9288
    @steveniemyer9288 Před 5 dny

    Thank you! The bag trick came in handy. I also had to use a thimble with the needle to drive out that small pin. For those who do this you have to take pressure off that detent spring in order to push the pin out. Took me about an hour to complete while watching the video, but I have fat fingers and terrible eyesight.

  • @adampettus
    @adampettus Před měsícem

    Valuable resource for me.

  • @arozeri1
    @arozeri1 Před měsícem

    excellent video. can you please specify the parts you used for the restriction block (3/8) that is in the output of the regulator? the link you sent to amazon is different , and have a low rating, as people claim it leaks. also, it takes 2 weeks to get it. thanks.

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      Thanks! The "Nash Fuel" brand Hose Block Power Valve linked above (3/8" NPT x 3/8" barbed) is the correct part. It was 2-day Prime shipping when I bought it, but now it seems to be 1-2 weeks on Amazon. Nash Fuel also sells it directly from their website. The price is a bit higher including shipping, but their website currently says "3-4 days". (I'm not sure if that means arrival time.) Nash Fuel also sells it on Ebay but the shipping time is 2-3 weeks. Currently, it has a 4-star rating on Amazon (with 29 ratings). Currently 2 of the 3 written reviews are bad but I think that those 2 reviewers are probably trying to use it for a different application, because they complain of gas leaking. In this application, the engine is sucking fuel from the regulator so the hose block power valve doesn't leak gas out. If anything, it leaks a bit of air into the fuel that's getting sucked into the engine.

    • @arozeri1
      @arozeri1 Před měsícem

      @@DaveRaveVideo thank you for the quick response. as i looked at the part that is in your video, it looks different than the "off the shelf" Nash fuel part in amazon. yours has adaptor between the Tee and the regulator. they must have changed this . thank you!

  • @AndTodaysProjectIs
    @AndTodaysProjectIs Před měsícem

    Holy smokes! This video could not have had better timing for me! We had a massive storm blow through Houston just now that knocked out The power on something like 900,000 homes. At about 8:00 p.m. I finally pulled my same generator out of the box in the dark and by cell phone flashlight added the oil and finally figured out how to fire it up. I had to cut off one of my 20 amp capable extension cords in order to backfeed that into my electrical panel. Of course I was not fully prepared with a list of breakers to feed my refrigerators so I struggled for 2 hours trying to figure out which breakers would feed the refrigerators to no avail. I have no idea what the hell is going on but I was able to trigger one of the GFI outlets in the kitchen so I just plugged in a couple extension cords internally in the house to power the refrigerators until tomorrow morning. I have a couple 30 lb propane tanks and three 20 lb tanks but it doesn't make any sense to do that since I have natural gas right at my grill like you do. So thankful for you and you taking the time to put together this extremely competent video for the rest of us who don't understand how to convert something like this. Amazing job sir and thank you for the bottom of our hearts in our home in Houston! I will use your links purchase the items that you listed.

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      The damage from that Houston storm made the national news this morning. I hope your power outage is brief. But if it's not, I hope that you're able to get the needed parts quickly or at least refill your propane tanks. Good luck! FYI: I did not want to go through the hassle & expense (including permitting and building inspection) of adding a generator interlock switch to my circuit breaker box-- especially for such a low-power generator. So I bought some extension cords & power strips (and 2 shore-power inlets) that I can use to bring electricity into the house and power some essential items like my refrigerator, gas-furnace, router, gas-range, Internet modem & desks/PCs, garage-door opener, LED string-lights, TV, etc. Just in case I'm away from home (but my wife & kids are home) during a power outage, I also added extension cords for difficult-to-move-or-reach appliances (fridge, range & garage-door-opener) such that the extension cord & appliance-plugs discretely emerge from behind the appliance, thereby enabling those appliances to be easily unplugged from the house-power and plugged into the extension cords from the generator, without moving the appliances from their cubbyholes. I also added a generator transfer switch to my gas-furnace so that it can easily be connected to the generator. www.amazon.com/Veepeak-Flanged-Waterproof-Trailer-Straight/dp/B0B87MNXLF www.amazon.com/BOYISEN-Generator-Transfer-Switch-Certificated/dp/B0BW91KN19

    • @reese2694
      @reese2694 Před měsícem

      I'm pretty sure it's illegal - and dangerous to repair crews - to backfeed without an interlock.

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      @@reese2694: Yes. An interlock is required by code to prevent back-feeding that could injure or kill repair crews. It also prevents damage to the generator from front-feeding (when the power returns). It would be illegal, but I think that both of those problems could be avoided if the incoming power supply to the panel is cut-off, but people forget to do that, which is why the interlock is required by code.

    • @AndTodaysProjectIs
      @AndTodaysProjectIs Před měsícem

      Dave, It is getting difficult to find propane in Houston and they are estimating we have another four or five days without power in my particular area. I absolutely hate cleaning carburetors out after using gas. Do you happen to know if I use regular unleaded gas in the generator to get through this event, am I then able to just run the generator for an hour or something like that on propane or natural gas to then completely clear the carburetor and the bowl out from having any regular gasoline remaining? My goal is just to not have to drain and clear that carburetor the old fashioned way if these systems are set up to work like that?

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      @@AndTodaysProjectIs: Thanks for confirming my concern that propane could become scarce in a major power outage. I don't know if running the generator dry of gasoline, and then running it on propane would clear all of the gasoline from the carburetor. It's an interesting idea, but I just don't know how the dual-fuel carburetor is set up. If switching to propane simply cuts of the gasoline-flow and if the propane simply feeds into the carburetor's gasoline bowl, then we might expect the propane flow to evaporate any remaining gasoline from the gasoline bowl (and its sediment pit), float, jets, throttle, etc. But I just don't know. If you find out, please let us know. Good luck!

  • @bibimcgill
    @bibimcgill Před 2 měsíci

    What do you mean by converting it? I just talked to the guy at Firman and he told me this is already a duel fuel generator.

    • @DaveRaveVideo
      @DaveRaveVideo Před 2 měsíci

      Conversion from dual fuel (gasoline & propane) to tri-fuel (gasoline, propane, & natural gas).

  • @Cmikul25g
    @Cmikul25g Před 2 měsíci

    not that it is basically a BCM stock....does that mean a BCM is a non adjustable stock ? Since you have to use a tool to manipulate it.

    • @DaveRaveVideo
      @DaveRaveVideo Před 2 měsíci

      I don't own a BCM stock nor did you say which model you have, but based in what I've seen on CZcams videos, at least some of the BCM stocks are length-adjustable by squeezing with your hand (without the use of a tool) so they DO NOT seem to qualify as a fixed-stock and would therefore be illegal to use in CA. czcams.com/video/xqlbIOhSKI4/video.htmlfeature=shared&t=465

    • @Cmikul25g
      @Cmikul25g Před 2 měsíci

      @@DaveRaveVideo yes, my bad...the method used in the video is how you take a BCM stock OFF a buffer tube....but yes, its always adjustable. i got confused there seeing the same action.

  • @tfwwhennofitlitgf3300
    @tfwwhennofitlitgf3300 Před 2 měsíci

    I normally just pin my CTR stocks in place with a paper clip underneath the crossbar, but the new DT stock doesn't have a hole for the paperclip to go through. I followed method 2 to remove the crossbar, and it works great.

  • @noads6566
    @noads6566 Před 2 měsíci

    So wait...your generator's 1/4" LPG inlet actually has a 3/8" barb on the back? And all 3/8" gas lines to the carb? That's extremely fortunate. My Champion has all 1/4" gas lines to the carb, which I guess means I need to find another option. But outstanding video, and it still helped me navigate options.

    • @DaveRaveVideo
      @DaveRaveVideo Před 2 měsíci

      Yes. Fortunately, on the Firman WHO3242 generator, the backside of the 1/4" propane quick-connect is a 3/8" barb, with a 3/8" hose feeding the carburetor. Not sure why Firman didn't use 1/4" hose, but I'm glad that they didn't. Since tri-fuel generators have natural-gas wattage ratings that are about 81% of their propane wattage ratings, if your Champion generator is rated for less than ~2,250W on propane, then 1/4" line is probably good enough supply it enough natural gas for (0.81 x 2250W=) ~1800W. My generator ran nicely on natural gas through the propane quick-connect up to ~1800W so I'm guessing that's the power limit of 1/4" hose.

    • @noads6566
      @noads6566 Před 2 měsíci

      @@DaveRaveVideo That's an excellent point. Thank you! My Champion 2500 is indeed small, with propane running watts = 1665W. Thus it should be capable of approx. 1350W with natural gas (0.81 x 1665W). Enough to run my fridge and a few lights. And the Champion's engine is 97cc, which is half the size of the WHO3242 engine. So I'll bet that you're right, and that the 1/4" propane inlet and internal lines won't be a bottleneck on performance with natural gas at this low level of power. I'm going to give it a shot and load test it. Thank you again!

    • @DaveRaveVideo
      @DaveRaveVideo Před 2 měsíci

      @@noads6566: Yep. I GUESS she'll run up to her natural-gas power-limit (~1350W) without being bottlenecked by the 1/4" line. I (and perhaps others) would be very interested to hear your results. Good luck!

  • @drbob7942
    @drbob7942 Před 4 měsíci

    After reading many of the comments, especially about trying to run NG directly rather than through the outboard regulator, I'll share some thoughts about that regulator. While it functions like a common pressure regulator, in service it's more like a flow regulator that's based on demand. In a typical regulator like the ones you might find on your gas grill, the regulator is there strictly to manage downstream pressure. Between that and each burner you have a valve to regulate the gas flow to individual burners. Each valve depends on having a constant upstream gas pressure so one burner doesn't change as flow to other burners' flow is changed. The regulator needed for the NG conversion is similar, but has a downstream pressure 'setpoint' that's slightly lower than atmospheric pressure. It's trying to maintain a slight 'vacuum' if you will. The outlet port senses the engine drawing on it while running, and opens to maintain that target 'vacuum' level by adding more NG as the engine asks for more air/fuel with load demand increase. With engine stopped, the regulator senses that outlet pressure is too high (above its slight-vacuum target pressure) and stops adding NG. Absent that level of flow management, a 'normal' regulator with a target out pressure slightly higher than atmospheric as the propane regulators do, would open instead and try to add more NG to bring the engine inlet pressure up. That situation happens when the engine isn't running. Bottom line though is that you MUST have something that shuts off NG flow when the engine isn't running. Using the regulator adds some self-adjustment to fuel flow as load and RPM's change in running service, something a solenoid valve won't. The gory details: On this generator's propane side, there's a solenoid-operated shutoff valve. It's open when the engine is running, closed on not running. If the engine is off or, more critically, if it stalls, that solenoid valve closes and blocks propane flow to the engine inlet. The actual flow metering is dependent on the size of a Venturi tube in the engine inlet. There's some flow physics involved to get the correct propane flow through that nozzle. Since the supply gas density and the ideal fuel/air ratios between the two gasses are different, a Venturi and flow restriction sized for one gas won't translate well for the other. In some ideal configuration, a separate larger venturi nozzle would be installed just for the NG fuel. Whether you used a separate flow regulator or not would be a choice that would include having a solenoid-operated shutoff valve for fuel flow, function similar to how the existing propane solenoid functions. Assuming sufficient supply sizing to maintain relatively constant inlet NG pressure through that second valve to the nozzle, it would run in load-sensitive mode quite nicely. This particular generator is an inverter type, so the throttle is RPM controlled based on load demand. More demand, more throttle and some more RPM's. In classic generators, a throttle governor is set for a constant 3600 RPM to maintain 60hz AC output frequency. The throttle is adjusted continuously to maintain that constant RPM. Using the Venturi nozzle for propane solves a large part of the fuel flow and mixture management while 'solving' for both RPM and load variations with the inverter. Adding another larger Venturi tube requires a larger and longer section of inlet piping if two are in the same piping. For compact/portable generators like this, there really isn't enough room to extend that pipe between the carburetor throttle and the two separated Venturis without having the carburetor throttle and air cleaner outside the casing. Instead of that second precise Venturi doing the flow and mixture control for us, we depend on that large regulator to vary the pressure upstream of the engine inlet, and include that adjustable bolt for fine-tuning single-point/load fuel flow management. Not ideal, but it seems to sort-of work OK. For longer-term flow management, I'd probably replace tune-by-ear with periodic inspections of spark plug color, after some run time in a typical use period. Finally, the look-see down behind the controls in the video shows the limit switch on the fuel-selector knob as a too-common microswitch. In a situation where there's a somewhat reasonable chance of having gas fumes I'd be looking for something that's just bit closer to 'intrinsically safe'. Portable generators aren't subject to the same rules for electrical components as fixed stations, and of course they are sold to a market price point, so such things are forgotten by cost managers. As we do our conversions and think about not having a hard and specific fuel shutoff on engine not running, think about those relatively open switches and the size of the fireball.

  • @tramonson
    @tramonson Před 4 měsíci

    This generator is currently on sale @Costco for 650 online or 599 in store till the end of March 2024.. Got one yesterday and it started right up on Propane. It now ships with a 3/8" quick connect so it's an easy conversion to add Natural Gas with a low pressure regulator like in the video.

    • @tramonson
      @tramonson Před 4 měsíci

      @@DaveRaveVideo Well scratch that Dave. There is a part number on the chassis mount quick connect of XQ14 which crosses to be 1/4". My confusion is that the supplied connector on the Firman regulator is bigger than my standard 1/4" connections I have around here. That's a weird connector.

    • @DaveRaveVideo
      @DaveRaveVideo Před 4 měsíci

      ​@@tramonson Bummer. The male & female 1/4" quick-connects on mine seem to be standard, because they work with other 1/4" quick connector components that I bought on Amazon. However, at 8:46 in my video I mention that I bought a 1/4" quick-connect kit at Ace Hardware that would not mate with the generator. I assumed that the Ace kit was non-standard, but maybe it's a difference between a US standard and metric standard?

  • @djfoxalaska
    @djfoxalaska Před 4 měsíci

    Using gasoline: One option is to completely run dry the tank and run a SMALL AMOUNT OF AVGAS FOR A FEW MINUTES. IT WILL NOT GUM UP THE CARB

  • @tommyt7566
    @tommyt7566 Před 4 měsíci

    Why? Why in the f’k do you still live in CA??? You know the solution to your problem - fix it!!!

  • @dannyjones6251
    @dannyjones6251 Před 5 měsíci

    I did the conversion on my Firman WH03242. Replaced the existing 1/4" propane quick connect adapter on the generator with a 3/8" NG quick connect adapter connected thru the existing hole with a brass bulkhead fitting. Had to drill out the inside and outside holes on the generator by about 1/8" to get the new fittings to work. Used 3/8" barbed fitting on the back of the bulkhead adapter. Needed to cut the hose a bit and heat it up to fit on the barbed fitting. Replaced the quick connect adapter on the existing regulator/hose that came with the gen to NG quick connect so that I could swap back and forth between NG and LPG. This does require two separate regulators/hoses to be stored! Everything worked absolutely perfect until I did the load test. Could push the unit to over 3000 watts on LPG but only get to about 2000 watts on NG. Zero obstructions in everything I did. Decided to look at the carburetor. The hose going to the carb is definitely large enough. Issue is the brass pipe connecting the carb to the hose. Its inlet is very small. Like 3/16" or less. That is way too small for NG to run at full power. I am wondering if they changed carbs between our unit builds. Like I said, I am able to get about 2000 watts perfect but pushing any further it starts bogging down. Happy with the conversion but I wasted a ton of time for no gain. For anybody looking to do this conversion, recommend taking gas tank out, removing hose from carb and examine the inside diameter of the brass fitting coming out of the carb. If something like 3/16" or less, just connect to the generator using the propane quick connect.

    • @Spammyfamily
      @Spammyfamily Před 5 měsíci

      I'd be a bit surprised (not terribly surprised) if they changed the inlet to the carburetor. Is there any chance that you forgot to remove the air inlet plugs on the natural-gas low-pressure regulator? (I forgot to remove those plugs twice, and it didn't run well.) Did you try running it without a natural-gas low-pressure regulator?

    • @dannyjones6251
      @dannyjones6251 Před 5 měsíci

      I wouldn’t be able to run it without the regulator as I couldn’t get it started. I did remove the plugs. That I did find out about the first time I played with it. The NG regulator works perfect on my ryobi that I had installed an aftermarket carb that supported trifuel. I should have taken a picture of the carb inlet. It is seriously small compared to the hose that connects to it. Talk about being disappointed…. Thank you though for your great video.

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      @@dannyjones6251: I'm not sure if it would help, but it could be that your low-pressure regulator is set to be too restrictive. Apparently, they are not all set identically. You might want to watch the following video from "Vlad F K" about how to adjust a Garretson low pressure regulator. (Remove the locking screw above the gas inlet, and then tweak the adjustment screw.) I didn't need to do this. czcams.com/video/d8A-k-TUnwg/video.html

    • @CharledKimble
      @CharledKimble Před měsícem

      One thing to consider, you will not get the output on NG as you do on LPG or gasoline. (look at the information on ANY tri-fuel generator)

    • @DaveRaveVideo
      @DaveRaveVideo Před měsícem

      @@CharledKimble: I explained that in my video. On natural gas my Firman WHO3242 generator runs smoothly up to at least 2650W (and 3000W on LPG). Dannyjones6251 commented above that he was only getting 2000W on natural gas.

  • @db.db12345
    @db.db12345 Před 6 měsíci

    I’m running into the same dilemma as you did. there aren’t any small quiet tri-fuel generators out there. Thanks for sharing !

  • @rawbdiggity
    @rawbdiggity Před 6 měsíci

    Awesome vid . I ordered an ai power 7100 today and I want to add NG capability to it. Hopefully it’ll be a similar set up. Thanks again for the detailed information.

  • @maptap6654
    @maptap6654 Před 7 měsíci

    Did you consider just changing the propane quick connect to a 3/8"? Maybe not as easily replaceable but would avoid the coiled hose. You would also need another adapter to use the supplied propane supply hose, but that's it, 2 adapters. And the on demand NG Century kit of course.

    • @DaveRaveVideo
      @DaveRaveVideo Před 7 měsíci

      At 9:14 in my video I said that I wanted to replace the 1/4" female quick-connect with a 3/8" quick-connect but, (1) I couldn't find a 3/8" quick-connect that had a threaded end that it could be mounted to the internal bracket, and (2) I couldn't find one that was thin enough in diameter to fit into the hole where the 1/4" quick-connect resides. (I didn't want to enlarge that hole and void the warranty.) If you find one please let me know. That would be a much nicer solution. It wouldn't be too difficult to adapt the propane output fitting and there are extension-cables available for the propane solenoid cable.

  • @bolriconyc3795
    @bolriconyc3795 Před 7 měsíci

    This video was so damn poetic and relaxing..... reminds me of a Bob Ross episode..... thanks for the video guy!!!!..... I'm going to go with your 2nd method..... this is for my PC9, i just ordered the Midwest industries chassis for it and have to pin my CTR stock and was wondering how the hell am I gonna get it done!!.... thanks again for the video guy!!!

    • @DaveRaveVideo
      @DaveRaveVideo Před 7 měsíci

      I think you're the 2nd person who compared me to Bob Ross. LOL. Happy to hear that my video helped. For a much easier method to achieve the 2nd option, you may want to try the method that ObYagTxha described in the comments below. He wrote, "Use pliers to twist the “notched” cross rod 180 degree (half turn), then it can be pull straight out." Others commented that this method works.

  • @Jack-ie8dc
    @Jack-ie8dc Před 7 měsíci

    Is it over yet??? My Lord, that was awful. Buy a fixed stock from magpul

    • @DaveRaveVideo
      @DaveRaveVideo Před 7 měsíci

      For many of us, Magpul adjustable stocks come with our AR kits, so it's cheaper to just make it tool-adjustable. Also, it's nice to have a tool-adjustable stock that can be adjusted for different family members and friends. Not sure why you watched this video.

  • @gsrtothemax
    @gsrtothemax Před 8 měsíci

    I just did this conversion following your steps. Worked out great! Just had to mess with the tuning and make sure my battery was charged up. Ran 1/2" hose 25 ft but haven't load tested it for performance yet. Just wanted to thank you for the great instructions!

    • @DaveRaveVideo
      @DaveRaveVideo Před 8 měsíci

      Happy to read that my video helped somebody! Thanks for letting me know!

  • @garrettdejong3282
    @garrettdejong3282 Před 9 měsíci

    Thank you for this video. So well made and informative. I have no idea why no one makes a tri fuel inverter, like not even one model.

    • @DaveRaveVideo
      @DaveRaveVideo Před 9 měsíci

      There are lots of tri-fuel generators, but unfortunately no compact ones. I guess that the generator manufacturers assume that people with natural-gas-fed houses have enough space for big generators.

  • @alex_119
    @alex_119 Před 9 měsíci

    Thank you! This same method worked great on my Magpul CTR stock, I just had to remove the hinge cover thing roll pin first and the rest was the exact same👍🏻😎

    • @DaveRaveVideo
      @DaveRaveVideo Před 9 měsíci

      Cool! Happy to hear that the video helped! That CTR stock is nice!

  • @RobManPDX
    @RobManPDX Před 9 měsíci

    This is great, thank you!

  • @RocksNRuts4
    @RocksNRuts4 Před 9 měsíci

    starts at 4:40

  • @RocksNRuts4
    @RocksNRuts4 Před 9 měsíci

    didt know the law was no adjustable-stock....

    • @DaveRaveVideo
      @DaveRaveVideo Před 9 měsíci

      Adjustable stocks on center-fire guns are illegal in CA, CT, NJ, NY, and maybe MD & VA, et al.

    • @RocksNRuts4
      @RocksNRuts4 Před 9 měsíci

      va too wow more proof how clueless DC n governors are@@DaveRaveVideo

  • @MrPatdeeee
    @MrPatdeeee Před 10 měsíci

    After viewing untold CZcams "Generators to Propane and NG kits"; I now believe that there is NO reason; to use a Regulator when using NG. Just connect it to the inlet* of the Carburetor. Yes, you DO need the Regulator when using Propane Gas. * you may need to use the "Y", but that is the only item you need when using NG. For what it's worth. Thank you kind Sir.

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      Carburetors are not leak-proof valves. So if you don't use a low pressure regulator, then natural gas will leak out of the carburetor when the engine is off. When I tried making a direct-connection to the carburetor I could smell the natural gas leaking out of the carburetor. The same is true of propane unless you have a normally-closed engine-activated solenoid valve (like the blue one that is included with the Firman generator). Also, if you don't use a low-pressure regulator (and a properly tuned hose-block-power-valve) you will essentially force-feed too much fuel to the engine, likely causing carbon build-up and reducing engine longevity. I tried direct connections with propane (without a solenoid valve) and natural gas (without a low-pressure regulator). The engine will run but it's dangerous, bad for the environment, and bad for the engine's longevity.

    • @jamahster
      @jamahster Před 10 měsíci

      @@DaveRaveVideoMy natural gas manifold already has a low pressure regulator hooked up to it. If I tee in-I am assuming I am getting the lower downstream pressure from that. I know my main comes in at 2psi. Do appliances (stove, dryer, water heater) typically have a built in regulators, which i am assuming runs at .5psi or less?

    • @DaveRaveVideo
      @DaveRaveVideo Před 9 měsíci

      @@jamahster I'm not sure what you mean by your "natural gas manifold" and I can't think of a reason why there would be a "low pressure regulator" downstream of your meter. So I'm guessing that by "low pressure regulator", you mean the service regulator at your gas meter. That is not a "low pressure regulator" like the Garrettson-Impco style regulator that I used in my video. From what I've read, natural gas from the street to your meter is typically ~2psi - 60 psi. The service regulator at your meter lowers that pressure to about 0.25 psi for your appliances to use. Natural gas appliances don't need pressure-regulators to further decrease the pressure below 0.25 psi because they were designed to work at 0.25 psi. Therefore gas appliances typically just have valves-- either (1) adjustable-valves that control the flame-height of appliances like stove-tops, or (2) on/off valves for appliances like water-heaters or furnaces where there's no need to adjust the flame-height. Low-pressure regulators take the pressure from 0.25 psi to 0 psi (or actually to something like MINUS 0.125 psi). Low-pressure regulators only allow gas to flow from their output if there is a vacuum on the output (i.e. gas is being sucked from the output). In this case, the low pressure regulator only allows gas to flow when the generator's engine spins and sucks air/fuel into the carburetor. Carburetors aren't like valve-controlled gas appliances. They don't get a force-fed fuel/air mixture from a valve. Carburetors suck in fuel/air. There is no leak-proof valve on a carburetor like there is on a stove-top burner. So if you don't use a low-pressure regulator, the natural gas (at 0.25 psi) will leak out of the carburetor when the engine is not spinning.

    • @swormser865
      @swormser865 Před 9 měsíci

      If you have a ng bbq hook up is that low enough ? Or still need low psi regulator Mine came with what I thought was a low pressure manufoukd for the propane attachment Can one use that ? Thx @@DaveRaveVideo

    • @DaveRaveVideo
      @DaveRaveVideo Před 9 měsíci

      @@swormser865 A bbq hookup is not low enough pressure. It's the same pressure (~0.25 psi) as every other gas outlet in you house. If you don't attach a low-pressure regulator (as I did in the video for my bbq outlet) then natural gas will leak out of the engine's carburetor because (unlike a bbq's adjustable burner-valve) carburetors are not leak-proof valves. The low-pressure regulator reduces the pressure to 0 psi (or less). It will only allow gas to flow if the spinning engine sucks in the gas. Firman's included propane regulator is designed to regulate much-higher propane-tank pressures. It also has a solenoid that prevents propane-flow unless its electrical connector is attached to the generator. This prevents propane flow from leaking out of the carburetor unless the engine is spinning (as mentioned above). It is possible to use an adapter to connect natural gas to the inlet of that the propane regulator, but the natural gas flow would be restricted by the the 1/4" hose and quick-connect, and so you'd only be able to run the generator at about 1800W (because natural gas has lower energy-density than propane and therefore requires a 3/8" hose & connector).

  • @TheSRMproject
    @TheSRMproject Před 10 měsíci

    Any idea how long it would run on a 5gallon propane tank? At 50%

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      I can't speak from personal experience but the widely used formula for this class of generator is: Gallons-of-propane-used per hour=Watts-used/3000×0.65. If by "50%" you mean 1500W, then the generator should use about (1500/3000x0.65=) 0.325 gallons/hour. Considering that "5-gallon" propane tanks really only hold about 4.75 gallons IF YOU HAVE THEM FILLED AT A FILLING STATION*, then that would be about (4.75 gallons/0.325 gallons/hour=) 14-hours per tank. This calculation jibes with the reviews that I watched & read about the WHO3242, wherein reviewers talked about how long a 5-gallon (20 lb) tank lasted in their real-world usage. If you gain better real-world knowledge, please let me know. *If you don't have your 5-gallon tanks filled at a filling station, and you instead do tank-exchanges like Blue Rhino or Amerigas, then the exchange tanks will only contain 3.5 gallons (15 lbs) of propane. In the calculation above, that would be 10.7 hours per tank.

    • @CharledKimble
      @CharledKimble Před měsícem

      @@DaveRaveVideo FYI, just watched a video today. He ran his RV for 9 hours using everything he wanted. (20lb tank)

  • @Neoptolemus03
    @Neoptolemus03 Před 10 měsíci

    Could you just replace the existing LP quick connect and use a 3/8 sized one for NG?

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      Yes. I would prefer to do that. But as I mention in the video at 9:15, I couldn't find an EXTERNALLY THREADED 3/8" quick-connector that could be attached to the existing bracket (with a nut), nor could I find one that is slim enough to fit through the front-panel hole. (I don't want to void the warranty by widening the hole.) Starting at 9:15 I showed several photos of the removed 1/4" quick-connector alongside a ruler and a caliper, just in case anyone wants to search for a suitable 3/8" replacement. (I should have clarified that in my video.) If you find a suitable 3/8" replacement, please let me know! If I could find and install a suitable 3/8" female quick-connector, I'd also try to adapt the Firman propane regulator's 1/4" male-quick-connect output to be a 3/8" male-quick-connect so that I could run on either natural gas or propane through the same female 3/8" quick-connector. If I did that, then the regulator's barrel electrical plug would likely need to be extended, but those extension cords are easily, cheaply available online. I'm pretty sure that the barrel connector is 5.5mm O.D x 2.1mm I.D plug, but it could be 2.5mm I.D. (It's hard to measure.)

  • @alexbaskous3603
    @alexbaskous3603 Před 10 měsíci

    Thanks for your efforts. Your numerous side experiments were interesting and show you have an inquiring mind. Am I correct in thinking that if a person is satisfied with 1800 Watts output, then using a 1/4 inch male quick connect natural gas hose connecter to the female generator quick connect orifice (rather than the Y hose addition) should be OK all else being the same?

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      IMHO, yes. If you're satisfied with ~1800W, then you can just run natural gas (NG) through a low-pressure regulator (for safety) to the built-in 1/4" propane quick-connect. Alternatively, you could probably just remove the 1st stage, metal propane regulator (that is connected outside-the-blue propane regulator) and directly connect gas into the second stage of the blue propane regulator. According to my notes... AFTER (not before) the engine warmed up really well, I was able to run it up to 1900W with it sounding pretty good. Above 1960W, it really started to bog down sounding unhealthy, and bordering on stalling. Once it started to falter into a stall, it usually would not return to running smoothly-- even if the entire electrical load was removed. (Not sure why. I guess it has something to do with the engine's computer not being programmed to deal with natural gas and getting "confused".) So if I were going that route, I'd target running it at 1800W or less. I seriously considered going the propane-quick-connect route instead of teeing-in a 3/8" NG line because 1800W is enough to run my refrigerator (370W), furnace (425W), Internet modem & router (~29W), a few laptop PCs (25W each), monitors (~27W each), a desktop PC (~200W-500W), gas range (2W) and some LED light strings. But as a rule of thumb, motor-startup surge is typically about double the running wattage, and so my fridge motor probably surges to 740W on startup, my gas furnace probably surges to 850W, and my electric garage-door-opener (445W) probably surges to 890W. So I was concerned that a startup-surge could stall the generator. I was also concerned that I wouldn't have much headroom to run "less-essential" electronics like a big-screen TV (170W) & coffee maker (1100W). So I decided to go through a bit more effort and cost to get it to run at a sustained 2430W (with an occasional surge up to 2650W being OK). If you go the propane-quick-connect route, please make sure that you buy a male 1/4" quick-connect that has a relatively thin rim as I showed in the video. The first one that I bought at Ace, didn't mate with the generator's female connector, but I THINK that's because it was non-standard. Not sure. Most of the ones that I see on Amazon, SEEM to compatible based on the photos. Good luck!

    • @alexbaskous3603
      @alexbaskous3603 Před 10 měsíci

      You are so helpful🙂. Thanks a lot. BTW I sent a message to Firman suggesting they consider making a natural gas harness optional or standard with the generator (because it would be popular and profitable). There are a lot of power outages worldwide these days and this easily stored /powerful generator would fill a niche.

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      @@alexbaskous3603 Yeah... It's unfortunate that there are no compact tri-fuel generators from ANY manufacturer. I guess they all figure that anybody with a natural-gas powered house has plenty of space for a big open-frame tri-fuel generator. They probably figure that compact generators are primarily used for RVs & camping. It wouldn't surprise me if they are correct that the market niche for compact tri-fuel generators is too small to address.

    • @alexbaskous3603
      @alexbaskous3603 Před 10 měsíci

      Maybe, but their low price and unique natural gas addition might give them an edge on the competition for “small generators. BTW I’ve been impressed with a friction lowering product called “Tufoil” used by the US military to prolong engine life. You might want to look it up. Thanks again.

    • @alexbaskous3603
      @alexbaskous3603 Před 10 měsíci

      (“Aperture” not aerators above)

  • @David-jx1vl
    @David-jx1vl Před 10 měsíci

    Well, this is exactly what I was looking for to use my WH03242 with NG. Idk why CZcams didn't show me this video in the results when I was looking but thankfully someone else linked it and it looks like everything I would need to do this is covered in the video so thanks for putting this together.

    • @DaveRaveVideo
      @DaveRaveVideo Před 10 měsíci

      I'm happy that you found my video and disappointed that it didn't show up on your CZcams search. I added every relevant keyword that I could think of so that it would be searchable. May I ask where you saw the link? (Maybe I should post links on some relevant forums or product reviews.) I hope my video helps you. Let me know if you have any questions. Good luck!

  • @ChatGPT1111
    @ChatGPT1111 Před 11 měsíci

    Very nice instruction to modify for Trifuel. I have a ng whole-house Generac and a Gas/Propane portable for backup but being that Generacs are unreliable, wanted a backup solution. I noticed several manufacturers have just released trifuel inverter gennys but they are expensive and currently only offering the larger sizes so this is a great alternate smaller gen solution.

  • @AustenConsulo
    @AustenConsulo Před 11 měsíci

    Great video, thank you for your contribution.

  • @winkydinkandyou
    @winkydinkandyou Před rokem

    Just wrap it with camo tape. Less then 10 bucks super simple to wrap around your stock and it makes your check welded much more comfortable

    • @DaveRaveVideo
      @DaveRaveVideo Před rokem

      If you simply wrap an adjustable stock with tape, California's DOJ would consider your AR-15 to be an illegal assault weapon. To meet the CA DOJ's requirements, adjusting the stock length must require a tool. No tool is required to remove tape.

  • @coir551
    @coir551 Před rokem

    Worked great 👍

  • @harmandeepsingh6598

    Awesome. Thanks.

  • @devilsaint_8652
    @devilsaint_8652 Před rokem

    Great info thanks. I purchased a Magpul complete lower kit from PSA then figured out I needed to fix the stock somehow. Now I know.

    • @DaveRaveVideo
      @DaveRaveVideo Před rokem

      Happy to hear that my video helped. For a much easier method to achieve the 2nd option, you may want to try the method that ObYagTxha described in the comments below. He wrote, "Use pliers to twist the “notched” cross rod 180 degree (half turn), then it can be pull straight out." Others commented that this method works.

  • @chiwawa130
    @chiwawa130 Před rokem

    There has to be a better way. Just for a sight????

    • @Spammyfamily
      @Spammyfamily Před rokem

      Yeah... It would be a reasonably easy replacement (and worth a price-adder for many Buckmark owners) if Williams sold fully-assembled rear sights. It was a pain-in-the butt, but I'm very happy that I did the swap.

  • @williamfotiou7577
    @williamfotiou7577 Před rokem

    Ummmm, if you remove the screw, while the stock is on the rifle, then it becomes adjustable! But anyway. I can't wait to move to Cali! Looking forward to helping you guys out with the cause and elect some more decent democrats. Those EVIL Republicans want to take your gun rights! Don't worry folks, my whole family is going to help elect some more awesome democrats. We won't stop till the streets are lined with windmills and unicorns! Nancy Pelosi for president!!!

    • @DaveRaveVideo
      @DaveRaveVideo Před rokem

      At 5:19 in my video, I say to separate the upper from the lower before removing the screw, in order to keep it legal. 🙂We law-abiding-citizens jump through these silly hoops, but the criminals don't. E.g. The terrorists behind the San Bernardino attack illegally obtained AR-15s, and tricked them out with 30-round magazines, adjustable stocks, pistol grips, etc.

    • @williamfotiou7577
      @williamfotiou7577 Před rokem

      Then I stand corrected! You're preaching to the choir, jersey is ALMOST as bad.

  • @goingfurther8092
    @goingfurther8092 Před 2 lety

    Thank you!

  • @ScottyBoy-bu2do
    @ScottyBoy-bu2do Před 2 lety

    love this idea. perfect solution for the commie state of MA.

  • @Rivenbarklarry
    @Rivenbarklarry Před 2 lety

    Great step by step instructions. Now my birthday present is ready for the range. Thanks

  • @UstesGreenridge
    @UstesGreenridge Před 2 lety

    Twist & pull to remove the locking pin. Didnt have to remove the roll pin.

  • @Patrick-kc5ur
    @Patrick-kc5ur Před 2 lety

    Here's an idea for a buffer tube with a blade or brace IF the ATF decides they are also "evil". Remove the brace/blade leaving the bare buffer tube. It may still have the rail on the bottom for an adjustable type "stock". Then slip over a section of foam "floaty" with the correct interior diameter hole. It will provide a cheek rest of comfortable foam and it can be slipped off in less than a second IF need be.

  • @materialgirl338
    @materialgirl338 Před 2 lety

    I took orange neon nail polish and created my dot to see better.

  • @idbuythatfora4223
    @idbuythatfora4223 Před 2 lety

    Those arent roll pin punches, they are just pin punches. A roll pin punch has a little ball on the tip so it stays centered on the pin.

  • @Stonehombre1
    @Stonehombre1 Před 2 lety

    OMG... I would never let you get near any of my weapons !!!!

  • @jackieeastom8758
    @jackieeastom8758 Před 2 lety

    The saddest video I’ve seen in a long time

  • @aburnett8685
    @aburnett8685 Před 2 lety

    Best DIY method I’ve seen so far. Turning a four minute video into a 15 minute rambling nightmare was a small price to pay :)

    • @JulioMo
      @JulioMo Před 2 lety

      Agree!

    • @davidcamarillo5971
      @davidcamarillo5971 Před 2 lety

      Thanks for posting, I thought it was just me! It was helpful but good lord...

  • @sonnyc.1994
    @sonnyc.1994 Před 2 lety

    Marvelous! You deserve a dozen doughnuts.