How to stop the Chiller plant(District cooling) with the help of SCADA .
zhlédnutí 844Před 3 lety
We need to stop the chiller plant when (TES) thermal energy storage tank is fully charged that is temperature of the water inside the tank reached up to 4.5 or below 4.5 degree Celsius in order to save the Energy. Following are the steps : 1. stop the chiller by giving stop command remotely 2. stop the primary chilled water pump remotely 3. close the modulating valve by setting the setpoint 0% ...
Chiller Parameters log sheet in Chiller plant
zhlédnutí 1,5KPřed 3 lety
Chiller Parameters Daily log sheet Evaporator: Set point Temp, CHW Leaving Temp, CHW Entering Temp, Refrigerant Press, Saturation Temp, Approach Temp ,CHW Flow rate. CHW(Chilled water) CONDENSER: CW Leaving Temp, CW Entering Temp, Refrigerant Press, Saturation Temp, Approach Temp ,CW Flow rate. CW (Condenser Water) COMPRESSOR: Comp no. of start, Running Time, Comp Rfgt Dis. Temp , oil tank pres...
Operating Chiller Plant(District Cooling) through SCADA/ BMS in Hindi -Urdu
zhlédnutí 5KPřed 3 lety
Before operating the Chiller plant we must know the followings: 1. Check all the status and setpoints of Pumps, valves, Fans,Temp, levels,flows,Chillers etc 2. Max & Minm Speed of motors etc 3. Amount of flow and Differentialpressure as per the design of the plant. 4. Follow the proper sequence as per the operational portfolio. SCADA is a control system which is used in industrial process. SCAD...
This Dua has Everything we need
zhlédnutí 110Před 4 lety
This Dua has Everything we need
Chiller Condenser water system in District Cooling Hindi/ Urdu Part- 6
zhlédnutí 636Před 4 lety
The condenser is collecting all the unwanted heat from the building and transferring it over into the condenser water loop where it will be rejected from the building via the cooling tower. The refrigerant and water never meet or mix, they are always kept separated by a metal wall, only heat transfers between them. Under the shell of the condenser, we have multiple tubes inside. These run from ...
Cooling Tower / COC/ Blow down in District cooling plant HINDI / URDU Part-5
zhlédnutí 2KPřed 4 lety
Induced draft cooling towers have fans that are typically mounted on top of the unit and pull air through the fill packages. List of Cooling tower components: Cooling tower Fan Gear box Drive shafts Fan motor Drift Eliminator Spray nozzles Fill packaging Cooling tower basin
Energy transfer station/Plate heat exchanger in District cooling Chiller Plant Hindi/Urdu Part-4
zhlédnutí 2,2KPřed 4 lety
Energy Transfer station transfer heat from district cooling system to building • Typically located in the Mechanical Room • Consists of Plate Heat exchangers, Pumps, Pressure Independent Control Valves & Motorized Valves • Hydraulic Separation between primary and secondary
Chilled Water system in District cooling/Chiller Plant Hindi-Urdu Part 3
zhlédnutí 3,9KPřed 4 lety
Chilled Water system in District cooling/Chiller Plant Hindi-Urdu Part 3
Overview of District Cooling/Chiller Plant in Hindi/Urdu Part-2
zhlédnutí 4,2KPřed 4 lety
Overview of District Cooling/Chiller Plant in Hindi/Urdu Part-2

Komentáře

  • @user-ed4ws1px9w
    @user-ed4ws1px9w Před 4 měsíci

    Walaikum assalam

  • @skfaisalali3023
    @skfaisalali3023 Před 8 měsíci

    WOW good information bro i need more videos related scada

  • @aerthmgaming8307
    @aerthmgaming8307 Před 9 měsíci

    Bhai aase or details me video post karo Software releted SCADA me or knowledge kese gain kare

  • @Haniyakhan8470
    @Haniyakhan8470 Před rokem

    Walaikumassalaam

  • @bothloveme
    @bothloveme Před rokem

    I have question : is the heat exchanger the cooler or the chiller itself?

  • @mdabdullah8819
    @mdabdullah8819 Před rokem

    Chiller plant ? It's HVAC?

  • @bhuminpatel2367
    @bhuminpatel2367 Před rokem

    Sir, How much capacity of chiller ??

  • @raja428
    @raja428 Před rokem

    As salaam alaikum brother...It is very nice video... Wanted to know more about TES tank and it's Thermal Insulation material

  • @younajmul99
    @younajmul99 Před 2 lety

    brother give me your number please

  • @mespak-fsd3870
    @mespak-fsd3870 Před 2 lety

    وعلیکم السلام Very Good 👍

  • @veerannark3023
    @veerannark3023 Před 2 lety

    Kidar hai bhai

  • @mohammadalauddin4021
    @mohammadalauddin4021 Před 2 lety

    Dear sir we need full details

  • @NitinRana108
    @NitinRana108 Před 2 lety

    Sir BMS aur SCADA alag alag hote hai ya same...

  • @b-rye428
    @b-rye428 Před 2 lety

    Awesome video 👍🏽

  • @abdullahbmjmkma5703
    @abdullahbmjmkma5703 Před 2 lety

    Please sir. Waste water plant operator.keliye scada on screen par Kaise operate kare. Complete video banae

  • @sirajuddinmohammed4558

    Kaim Brother-- Please share your number

  • @mdakhil2647
    @mdakhil2647 Před 3 lety

    Sir...heat exchanger kyun lagate hai building se pahle....bcs aleradt we are getting the amount of gpm with maintaining the DELTA T into the particular building Kindly, clear this doubt and appreciate ur efforts sir

  • @AshrafKhan-xu4wk
    @AshrafKhan-xu4wk Před 3 lety

    sir Chiller opearating ki vecancy aati hain gulf mein

  • @SURESHKUMAR-yg8tu
    @SURESHKUMAR-yg8tu Před 3 lety

    Aslamwalakum I’m Suresh Kumar from Ideal Solutions India, Kerala, India interested to implement the Radiant cooling system in , Kerala, India. Kindly give me the guide lines for this. Where is ur location, and where the plant situated. My wup no 9526929029.

  • @mohammadsajid1775
    @mohammadsajid1775 Před 3 lety

    Bro very attractive information. I need how to check trends ( graphs) and how it makes . Plz 🙏 make video

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Very nice video

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    very nice video Masha Allah god bless you Sir

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    🌹🌹🌹🌹🌹🌹🌹

  • @mohsinfarooq5238
    @mohsinfarooq5238 Před 3 lety

    Whatsapp me 00923238663883

  • @mohsinfarooq5238
    @mohsinfarooq5238 Před 3 lety

    Plz bro whatsapp me 00923238663883

  • @mohsinfarooq5238
    @mohsinfarooq5238 Před 3 lety

    Gud

  • @abdulshahbaaz5348
    @abdulshahbaaz5348 Před 3 lety

    Aslamwalakum

  • @bakkrudeennes408
    @bakkrudeennes408 Před 3 lety

    Excellent 👌👍

  • @gadgetstripetest2808
    @gadgetstripetest2808 Před 3 lety

    Very good and educative too

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    🌹🌹🌹🌹🌹plz🆑 sir

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Very nice speech sir Masha Allah god bless you Sir

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Mughe apka what'sapp number chahiye sir

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Very nice speech sir Masha Allah god bless you Sir

  • @lutforrahmanprince2045

    thank you sir...very nice

  • @irshadansari-eq9nb
    @irshadansari-eq9nb Před 3 lety

    Informative

  • @sultanshaikh6863
    @sultanshaikh6863 Před 3 lety

    Wa alaikum assalam

  • @freshandcooltransport1161

    Nice video.

  • @hafizshah7705
    @hafizshah7705 Před 3 lety

    Make video about monitoring and controlling parameters and thier consequences. Makeup watar system and their chemicals properties. Cooling tower controlling parameters.plz sir I m so needy of this

  • @rohan__boy95
    @rohan__boy95 Před 3 lety

    Nice concept par dono tarf se video bnate to jyda achha hota

  • @rohan__boy95
    @rohan__boy95 Před 3 lety

    Great effort please explain all components and flow digram of district cooling system on piece of paper by pen

  • @gulabrbbani2261
    @gulabrbbani2261 Před 3 lety

    COC ka full form

    • @automationkarim8393
      @automationkarim8393 Před 3 lety

      The COC (Cycles Of Concentration )specifies, how often a fresh water added into the loop, can be used or pumped around, before the water has to blown down or bleed off from the cooling tower.

  • @gulabrbbani2261
    @gulabrbbani2261 Před 3 lety

    PTHE ka work achha se samajh nahi paya sir is ka main work kya hota hai or ye heat exchange karta h to kaise karta h..Kya chiled water supply ko direct ahu me nahi bhej sakte hai

    • @automationkarim8393
      @automationkarim8393 Před 3 lety

      For further understanding go through the link czcams.com/video/Jv5p7o-7Pms/video.html

  • @gulabrbbani2261
    @gulabrbbani2261 Před 3 lety

    Is me ahu nahi rahta h Kya..sir

    • @automationkarim8393
      @automationkarim8393 Před 3 lety

      AHU is in customer sides

    • @gulabrbbani2261
      @gulabrbbani2261 Před 3 lety

      @@automationkarim8393 chlied water direct ahu me nahi de sakte hai sir..heat exchanger ka Kya faida h ..or heat exchanger me kaise exchange hota hai

  • @pinkykumarisahani5690

    Sir. I'm so good. Please reply me sir. Sir one question my. Gas charging process in chiller. How to gas charge in chiller.

  • @jafarmuhammad5584
    @jafarmuhammad5584 Před 3 lety

    MashaAllah ap video buhut informative hoti hain. Sir centrifugal chiller k parameters pr video banain.

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Very nice speech sir Masha Allah bless you Sir 🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹

  • @kamrulk2833
    @kamrulk2833 Před 3 lety

    Very nice speech sir Masha Allah bless you Mai BMS kr rha hu sir mujhe apka what'sapp number chahiye plz Sir give me number ye mera hai 9102080080 whatsapp number hai very nice video sir🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹

  • @sahilwrites9485
    @sahilwrites9485 Před 3 lety

    Good Job bro , keep uploading

  • @mohdtausif5360
    @mohdtausif5360 Před 3 lety

    Plz show smp powder plan how to operate by scada

  • @Mamafoodsecretss
    @Mamafoodsecretss Před 4 lety

    Mashallah subhanallah nice sharing sister I'm join with you 🔔 stay connected 👍 please watch my video ❤️❤️