PPTS Duble Stopple Animation
Plante Tech - Power Offers Specialzed Pipeline Repair & Maintenance Services Eliminating the Need of Shutdown of Service.
This Video Simulates Hot Tapping With Double Position Line Stopple Using Housing To Housing Temporary Bypass.
Reach Us At
Emial : pls@plant-techgroup.com l Phone : +919740521166
zhlédnutí: 246 924

Video

36" Angle Tap on 42" Flare Line in BPCL Mumbai
zhlédnutí 4,1KPřed 8 lety
Successfully Executed Biggest Ever Angle Tap in India (36" On 42") 19th June 2015 was a historic day in the field of Hot Tapping Services In India, as Plant-Tech successfully completed 36" Angular Hot Tapping, The biggest ever angular tapping executed in India thus far. Our esteemed Client, M/s Offshore Infrastructre Limited was awarded with LSTK contract of plant turn Around in Bharath Petrole...
12" Hot Tapping in LP Steam Line in BPCL Mumbai
zhlédnutí 6KPřed 8 lety
Slide Show of execution of 12" LP Steam Hot Tapping in BPCL Mumbai
24" Angle Tap On 30" Flare Line at HPCL Mumbai
zhlédnutí 775Před 9 lety
24" Angle Tap On 30" Flare Line at HPCL Mumbai
Hot Tapping & Double Double Stopple on 24" Crude Oil Line
zhlédnutí 93KPřed 9 lety
This Project Involved Replacement of 9.8 KM Length Of 24" Crude Oil Pipeline of SMPL-IOCL By Doing Hot Tapping & Double Double Position Line Stopple at 4 Locations.
Simulation - Hot Tapping And Double Position Line Stopple Using Temporary Bypass
zhlédnutí 11KPřed 9 lety
This Video simulates the Hot Tapping & Double Position Line Stopple Operation Using Temporary Housing To Housing Bypass
Various Hot Tapping Projects Undertaken By Plant Tech Power
zhlédnutí 2,5KPřed 9 lety
Manufacturing of 36" and 30" Line Stop Fittings Execution of 36" & 30" Double Stopple Execution of 24" Double Double Stopple And Other Hot tapping Pojects

Komentáře

  • @fredyruiz8854
    @fredyruiz8854 Před 4 měsíci

    Impresive work....

  • @josephastier7421
    @josephastier7421 Před 5 měsíci

    Some magical processes here

  • @ghezalabdelhamid7788

    Thank you for this information, could i know what is the programme that you use for simulation

  • @davidboyman2633
    @davidboyman2633 Před rokem

    where does the pressure go when putting on blinds?

    • @mickraff66
      @mickraff66 Před 11 měsíci

      I cannot work that bit out ?

  • @martkyfristkysalomosenduk9983

    Sir, may i ask you a question, is it mandatory to install the ballon plug?

  • @pauledwards1157
    @pauledwards1157 Před 2 lety

    Too many errors in this video.

  • @anuragkumar7740
    @anuragkumar7740 Před 2 lety

    Nice informative video covering all concerned points.

  • @YasirAli-wz8kd
    @YasirAli-wz8kd Před 2 lety

    Tag bcj

  • @yancenazifah8151
    @yancenazifah8151 Před 3 lety

    Nice stopple equipment.

  • @danielmoreno8493
    @danielmoreno8493 Před 3 lety

    I dont understand. I thought double doubles would have had 4 taps and bypass goes behind the stop but I may be confused

  • @yrun989
    @yrun989 Před 3 lety

    [Welder life]ofical cut[SV] Pipe line test √ Just meter

  • @irishcarascon8158
    @irishcarascon8158 Před 3 lety

    hi what is your email address?

  • @navgunner80
    @navgunner80 Před 4 lety

    this looks like a yellow version of TD Williamson equipment. Was this just a repaint of their equipment?

  • @davidhopkins7215
    @davidhopkins7215 Před 4 lety

    What is considered Low Pressure?

  • @anarismayilli5499
    @anarismayilli5499 Před 4 lety

    czcams.com/video/EVKuW67K4KQ/video.html

  • @bijiyantsinghsingh4359

    Nice job

  • @user-pm2pp4fo8g
    @user-pm2pp4fo8g Před 4 lety

    لو سمحت ممكن طريقة هذي أمته تمه اكتشافه وتاريخ في فيدو

  • @MegaRIFIANO
    @MegaRIFIANO Před 5 lety

    technician without gloves, technician on line of fire, technician climbing on the valve, scaffold not tagged, etc.... etc...this company is not the safest...a mix of pictures of different job with different type of machines....Hope the camera was ATEX

    • @jonathanmanley8739
      @jonathanmanley8739 Před 5 lety

      MegaRIFIANO cold cut guy is in there with no FR and short sleevesAND a polyester golf shirt......definitely not real pipeliners

  • @boddetiramakrishna6489

    Hot Tapping & Double Double Stopple on 24" Crude Oil Line

  • @user-ku2nh1ci2c
    @user-ku2nh1ci2c Před 5 lety

    Для специалистов из РФ, на все вопросы по трубопроводной арматуре (pipeline accessories) ответят наши инженеры: saratovsnab.ru/

  • @karlwooduk
    @karlwooduk Před 6 lety

    awesome.

  • @anhtuantran9194
    @anhtuantran9194 Před 6 lety

    hi guys. we provide some products like this. we have many sizes of pipe line repairs. just contact us via justin@nuoen.vn

  • @adanperez6524
    @adanperez6524 Před 7 lety

    every liquid has a boiling point for it to ignite. if it is to rich doesn't ignite.another scenario is that need to be present the right elements like fuel,oxygen and fire.

  • @magip355
    @magip355 Před 7 lety

    How is it that the product doesn ignite as s result of the heat of the first drilling point (to install the spool fir the bypass line)

  • @TheGauravgothwal
    @TheGauravgothwal Před 7 lety

    was it a process line . or utility line ?