  • Coil movement 10 days after embolization. Several coillectomy attempts:
    - Direct aspiration 5F
    - Stentriever + aspiration 0.035 (2 attempts)
    - Snare - perforation - hemorrhage
    - Remodeling mesh + aspiration 5F (2 attempts)
    - Stentriever + aspiration 5F (2 attempts)
    Finally, placement of a stent. Probably should have been tried as the first option
    Tirofiban was used despite perforation. There was no further complication