2200VA UPS APC to Solar Inverter

Sdílet
Vložit
  • čas přidán 27. 06. 2020
  • Today I bought an old 2200C APC UPS. It costs $ 100. I will convert it into a solar inverter. In this video, I will clean it, Add a battery connection, reduce the no-load current and test its capacity. In the next video, I will add a large capacity MPPT charger, Automatic switches and protective devices.
    All my projects are free, I design them on EAGLE 6.0. I uploaded it to Google drive. You need to use a web browser to download the file and open the file with winrar software (extract) on the PC. Open schematic file (.SCH) and PCB file (.BRD) with EAGLE software.
    Hope you enjoy my videos and projects. Like, share and don't forget to subscribe to my channel. one more thing, thanks to everyone, my channel has reached 50K subscribers.
    #APC2200VA
    #Inverter
    #Solar
  • Věda a technologie

Komentáře • 223

  • @PhdHung
    @PhdHung  Před 4 lety +19

    Today I bought an old 2200C APC UPS. It costs $ 100. I will convert it into a solar inverter. In this video, I will clean it, Add a battery connection, reduce the no-load current and test its capacity. In the next video, I will add a large capacity MPPT charger, Automatic switches and protective devices.

    • @kashifhussain4246
      @kashifhussain4246 Před 4 lety +5

      How you claim, it works as solar inverter. On other way you connect the batteries on load test.....
      Connect the solar to it and then load test....variable solar voltage and current not support apc ups then it shutdown immediately.

    • @winifsan3873
      @winifsan3873 Před 4 lety +2

      @@kashifhussain4246 That's what a solar charge controller is for. He will add an MPPT one.

    • @ambersmith6517
      @ambersmith6517 Před 3 lety

      He will also add some caps I would think

    • @leviahamefula3994
      @leviahamefula3994 Před 3 lety +1

      Why do you calculate the no load output with 48v? Is the UPS 48v or 24v?

    • @alexpescaru
      @alexpescaru Před 3 lety +3

      When you added that filter coil to reduce the no-load current, how did you calculated the number of turns, wire section, type of core, etc?
      Is there any math behind it or in this case was an arbitrary choice?
      Thank you.

  • @stephenwgreen78
    @stephenwgreen78 Před 3 lety +3

    Great job. Love reusable old technology. 👍

  • @smoke_stackz3168
    @smoke_stackz3168 Před 4 lety

    Your the real king of homemades😁👍👍👍

  • @1brasov
    @1brasov Před 2 dny

    Thank You for that excellent video!!! I did a Cyber Power 1900 a few months ago, not nearly as neat as your example here. That was great how you figured out how to reduce the idling current of your inverter! And wound your own inductor!! My UPS draws 55 watts at idle, and I always felt that was a bit high. I may try to duplicate your idle current fix on it. I run my ups output into a 6 circuit generator transfer switch. It is great to have when the power goes out .All I see is the 20 Milli second light flicker when power goes out. Its easy to miss that! It takes care of power outage with no intervention on my part. I did not know I have a brother somewhere. Thanks for posting your video!!!!

  • @biswajitnath8787
    @biswajitnath8787 Před 4 lety +1

    Awesome conversation sir,,,

  • @DIYwithBatteries
    @DIYwithBatteries Před 4 lety +1

    Wow 😍 looks awesome Dude!

  • @coolguytajith8980
    @coolguytajith8980 Před 4 lety

    good work, i am waiting for the next part

  • @gumnahs
    @gumnahs Před 3 lety

    Awesome work 👍👏

  • @Edmorbus
    @Edmorbus Před 4 lety

    very good project

  • @bomche115
    @bomche115 Před 4 lety

    Great. I like video. thanks you

  • @engineerirfan
    @engineerirfan Před 4 lety

    Nice Good Job

  • @andre-le-bone-aparte
    @andre-le-bone-aparte Před 2 měsíci

    Just found your channel. Excellent Content. Another subscriber for you sir!

  • @unggulwibowo8380
    @unggulwibowo8380 Před 4 lety +1

    By the way I like your vidio...and i hope after this project you will soon continue part 2 cos, I will learn how to make my Ups 3kva ( used ) for solar system with Mppt modul....thanks lots

    • @PhdHung
      @PhdHung  Před 4 lety +1

      Yes, I am designing a desk for the inverter and battery.

  • @rmxgaming6812
    @rmxgaming6812 Před 4 lety

    Nice brother

  • @ambersmith6517
    @ambersmith6517 Před 3 lety

    i am a fan i like your work

  • @electronic7979
    @electronic7979 Před 4 lety +1

    Super

  • @OleBrinch
    @OleBrinch Před 3 lety +3

    I have had an APC SUA2200 running for 6+ month on a 80 kWh diy powerwall with no shutdown. Works fine. I have idle losses lige yours. The filter interests me, but I have gotten hold of a toroidal 3000VA transformer from another brand of 3000 VA/48 volt UPS that has blown electronics. I also got hands on a APC SUA3000 and I think I will swap trasformers.
    It seems than 90+% of the losses at idle is from the transformers which get pretty hot. The MosFets never get really hot.
    You have a new subscriber :)

    • @PhdHung
      @PhdHung  Před 3 lety +1

      Yes, I think if you replace toroidal transformer, the efficiency will be higher. I also replaced mosfet irf4710 with irfp4110. it is much stronger.

    • @user-jh3jc1tn9e
      @user-jh3jc1tn9e Před 9 měsíci

      Pa ada kh jual aisi inventr apc K411

  • @DimitriPappas
    @DimitriPappas Před 4 lety +5

    Cool bro! Wish I understood how that inductor works to lessen the load... It has no losses while load applies, or affects waveform in some way? I'm not sure why some people are hating this video because you didn't build it yourself. At least you bought it used, and refurbished it. If they are so smart they should make their own videos. You're the one with all the views and subs. Good job !

    • @PhdHung
      @PhdHung  Před 4 lety +7

      I'm just an amateur, I've seen Chinese inverter (use EGS002 modules) use an inductor at the transformer primary. and the no-load current drops. So I tried it. Thankfully it worked fine, The waveform did not change, it is still true sine. Conversion performance increases.

    • @udisami9856
      @udisami9856 Před 4 lety +10

      @@PhdHung The inductor serves to filter out the modulation frequency (in the khz range) that the transformer core reacts to by converting most of it's energy to heat due to the hysteresis effect of iron which can't handle such high frequencies, resulting in early core saturation and an increase in the magnetizing energy. A well made transformer that has been specifically designed for the inverter will have enough leakage inductance to filter out the modulation frequency (on the expence of size and cost) eliminating the need for a separate input inductor.

    • @holidayrap
      @holidayrap Před 3 lety +2

      @@udisami9856 I appreciate the explanation!

    • @zoltandoczi8118
      @zoltandoczi8118 Před rokem

      @@udisami9856 👌🙏

  • @philblanchfield
    @philblanchfield Před rokem +1

    What happens if there is a short across those 2 completely exposed terminals that you put on the back of the UPS? I am thinking that those skinny wires on the batteries will light up.

  • @raba7201
    @raba7201 Před 4 lety

    Teşekkürler

  • @davidkwamemensahtawiah1703

    Thanks

  • @skynetcybersystem3tech

    perfekt

  • @viciriucandreea5835
    @viciriucandreea5835 Před 3 lety +1

    Ok felicitari

  • @kaushikreja
    @kaushikreja Před 3 lety +2

    Good work to reuse old ups. One question in mind. How did you stopped ups charging mechanism? Or you just have kept disconnected grid input for ever?

    • @headlessxp4948
      @headlessxp4948 Před 2 lety

      The UPS uses its main transformer to charge the batteries so you cant really "disable" the charging circuit. The way I did it is to just connect a diode between the battery and the UPS. But dont use a regular diode! With a regular diode you have to much voltage drop and therefore power loss. Use some high quality, low RDSon MOSFET, something like multiple IPP023NE7N3GXKSA1 and the LM5050 IC to build an ideal diode. With such an ideal diode you should be able to achieve about 10W of loss max at maximum load.

  • @mipad6105
    @mipad6105 Před 4 lety +2

    Neyi düşünsem yada merak etsem videosunu yapıyorsun !! Telepati mi var aramızda, bilmiyorum ! :)
    Dört gözle takipteyim...
    👀👀
    🤔
    👍👌

  • @ambersmith6517
    @ambersmith6517 Před 3 lety +2

    A year or so ago I tried several different chokes it helped very little to none
    I concluded that the losses was in the Square Transformers
    I plan on building a toroid for it but I didnt know or check the voltage of the other wires if I remember correctly it has 4 or five instead of two
    Do they need the other wires

    • @gumnahs
      @gumnahs Před 3 lety

      The wire tapping will be like 0,170,220,240 and small two wire loop around 25v for charging.

  • @anatoliyovdiy6466
    @anatoliyovdiy6466 Před 2 lety +1

    Hi, can you please provide more specs on the inductance you winded? how many winds you did? Maybe you could tell which specs are needed so I could buy one already assembled?

  • @stingerbold9327
    @stingerbold9327 Před 4 lety

    i already got 3 of those each cost me about 80$ but not APC other brands

  • @croma-cctv5211
    @croma-cctv5211 Před rokem

    Can you explain if the toroids used are of MnZn composition? ( pc40 toroids ) Thanks

  • @cherechicherechi7792
    @cherechicherechi7792 Před 2 lety

    Very nice and interesting video bro. I have 2 of those APC 2200 UPS already; though old ones and wants to use them for inverters too. My worries are on how to charge the batteries?
    Can you help me with a stage by stage explanations of all you just did on your video?

  • @prashanthb6521
    @prashanthb6521 Před 2 lety +1

    I wish I could see the general outline of the circuitry. I did not understand where you connected the inductor and other few details.

  • @adiwickx
    @adiwickx Před 2 lety

    Question number 1 where you connected solar panels? 2nd main grid should be taken out from APC 3rd how you are going to charge batteries? We need mpt solar charge controller 24V ?

  • @piljaga1
    @piljaga1 Před 6 měsíci

    I have 3000VA APC UPS and want make solar inverter too. But it cant do first start wirhout mains (if it is solar inverter there are no mains at all). If I connect mains it starts, then disconnect mains UPS keep working on battery. Which element checks mains existance condition? I should remove this element. Can you help me?

  • @jayusmandev6524
    @jayusmandev6524 Před 4 měsíci

    How you remove the UPS time limiter..every UPS natively has set amount of time to stop automatically..how you bypass this one..by modified the circuit or by software?

  • @gheenoeshomfer4982
    @gheenoeshomfer4982 Před 2 lety +1

    Hi Awesome tech!, Today I found two SUA5000RMT5U apc 4000watt ups backups. I wonder if I could use these in a solar system and connect one on each leg of a 240 volt household breaker box somehow... will watch your videos with interest!

  • @mehmetfevzisahin7110
    @mehmetfevzisahin7110 Před 2 lety

    Hı , my online ups 1000va and does not have transformer( only board component ) how can i reduce no-load current ? Thanks

  • @eduarmon2128
    @eduarmon2128 Před 2 lety +2

    Hi, awesome video here. I just got this exact APC 2200 UPS. I don't have Solar panels/charger. Can the UPS handle charging those external batteries from mains/grid supply?
    Thanks

    • @PhdHung
      @PhdHung  Před 2 lety

      Yes sure. It can charge with 8A current from the mains

  • @darrenorange2982
    @darrenorange2982 Před 2 lety

    So you can power the inverter with one 24V battery?

  • @eduardocabrera1740
    @eduardocabrera1740 Před 2 lety

    how to disconnect the battery charger in the circuit?

  • @crossmaster27
    @crossmaster27 Před 4 lety +1

    Acá en mi país esa UPS 2200C APC nuevo cuesta $648.90 + impuesto demasiado caro pero tu lo compraste viejo y usado a $1.00 eso se le llamo la suerte de un perro callejero (☞゚ヮ゚)☞ literalmente hablando ☜(゚ヮ゚☜).

  • @sarulraj
    @sarulraj Před 3 lety +2

    Great video Homemade! I have already setup a 600watts solar panels 96V DC with EPEVER MPPT charge controller connected to the same UPS but it shutdown after runtime process ends even if the batteries are fully charged. Can you or any fellow youtubers help me how I can use Hyper Terminal to change the settings of the UPS? What's the command to do this? Thanks in advance!

    • @PhdHung
      @PhdHung  Před 3 lety

      u use SUA2200i ?

    • @sarulraj
      @sarulraj Před 3 lety

      @@PhdHung Mine is IBM
      UPS 1500THV 1500VA

  • @smultimediasg
    @smultimediasg Před 4 lety +1

    pls make a micro grid tie solar inverter with your style.

  • @walleywalley
    @walleywalley Před 13 dny

    you just converted it from no battery pack model to battery pack model:)

  • @dilevehshee
    @dilevehshee Před 2 lety

    great work.
    Is it possible to supply Solar panels DC volts instead of using batteries.
    If yes how many solar panels will be enouh to supply 2200VA

  • @christosmakariou4574
    @christosmakariou4574 Před 2 lety

    What is the model of the power meter and where can I buy it from?

  • @Andy-df5fj
    @Andy-df5fj Před rokem

    How do you know upfront whether a UPS utilizes 12v, 24v or 48v batteries?

  • @rawandjaza5929
    @rawandjaza5929 Před 4 lety

    Can use this trick filter inductor to reduce load amps ?

  • @edgarsdiytv5535
    @edgarsdiytv5535 Před 4 lety

    Does it run 1.5hp acu? And how long it'll last?

  • @thedalailmao
    @thedalailmao Před 2 lety

    Hey, just curious. How loud is this fan when the battery is charging?

    • @PhdHung
      @PhdHung  Před 2 lety

      when charging it is quite silent. The fan is noisier when operating at 1500 > 2000W.

  • @KinhKha-lm2zl
    @KinhKha-lm2zl Před 4 lety

    hôm rồi anh tính mua cái cục này 1 triệu rưỡi ....nhưng không mua ...uổng quá...,he he he nhưng đợt trước anh nói với em là anh có 2 cái biến áp của cục này ...tính nhờ em làm inverter...để em quay video đó.....he he he hôm nào thiết kế theo ý của em nha,,......he he he anh chỉ có 2 cục biến thế này thôi....

  • @zachariakihara2216
    @zachariakihara2216 Před rokem

    What batteries does this ups use

  • @tambamaneoliver
    @tambamaneoliver Před 4 lety

    Mr ? Are you sure that is the UPS you are using for those elements you are connecting to? why are you not showing all the cables in your video? i have made so many inverters using UPS transformers and plastics and materials used in the transformer they all melt after a period of time.So i will be satisfied if you can all you cables. Thank you

  • @abrarswb
    @abrarswb Před 4 lety

    Dear , which software you are using for video editing.

  • @jackpatteeuw9244
    @jackpatteeuw9244 Před 4 lety

    Software in APC UPS units actually shut them off after a certain amount of time. They will NOT run continuously regardless of the input voltage.

    • @PhdHung
      @PhdHung  Před 4 lety

      I have tested it. It works until the battery is weak (42V).

    • @PhdHung
      @PhdHung  Před 4 lety

      If you want to set up UPS, use Hyper Terminal

    • @kja9893
      @kja9893 Před 3 lety +1

      Where can I find instructions to set up UPS using Hyper Terminal and what parameters to use to disable the runtime process? I am using a APC UPS1500THV and followed your instructions but after the runtime, the UPS shuts down even the batteries are fully charged.

    • @sarulraj
      @sarulraj Před 3 lety +1

      @@PhdHung I have setup the Hyper Terminal and can access the UPS. What do I need to change so that it will shutdown only when the voltage go to 42V like you did? Can you tell me which command to by-pass the run time? Thanks.

  • @user-dt1lm2lp7s
    @user-dt1lm2lp7s Před 4 lety +1

    هذا اليو بي اس يستخدم لطابعة الاشعة والحاسبه الامريكية لطبع افلام الكوداك انا عندي واحد وفيه 4 بطاريات كل بطاريتين مربوطه توالي وبعدين يربطن توالي لزيادة الفولتيه قدرتها 5 كيلو واط

    • @PhdHung
      @PhdHung  Před 4 lety +1

      Yes, it works at 48V, in my country, it has a lot of second hand shops. A lot cheaper than a new inverter.

  • @jamesobrien4341
    @jamesobrien4341 Před 4 lety

    Tried everything you said and I still can't get it to work... Don't what I'm doing wrong.

  • @adeshinaajibola5114
    @adeshinaajibola5114 Před 3 lety

    Good day Admin...I am longing for the update and schematic diagram

  • @andarmanurung
    @andarmanurung Před 11 měsíci

    Bisa tolong di jelaskan
    Kenapa memakai kabel serabut saat konek kabel ke sisi tafo primernya.
    Memang hasilnya mantap krna amper stanbaynya langsung turun .
    0.8 Amper dari 1.3 Amper.

  • @user-cd1ji5tp2m
    @user-cd1ji5tp2m Před 4 lety +3

    Куда ставит индуктивность?

  • @bongbernalbong4355
    @bongbernalbong4355 Před 2 lety

    hello, can u sent me a picture of the board particularly the IC18., i got a board like that with a burn and deface ic. tnx.

  • @archildavidovi1150
    @archildavidovi1150 Před 3 lety

    where is coil connected? please give me more detailed information.

  • @kAUTTIN
    @kAUTTIN Před 3 lety +1

    cool, I have the same apc and I'm going to use it instead of an inverter, what was the maximum time of direct use with 48v power? stress test

  • @Drzewacz888
    @Drzewacz888 Před 4 lety +1

    But you didn't connect any solar panels to it just external batteries. So why solar inverter?

    • @PhdHung
      @PhdHung  Před 4 lety

      Please read the video description, This is part one. In part 2, I will build an MPPT module for this inverter, it can charge the battery from the grid and charge the battery from solar panel.

  • @ambersmith6517
    @ambersmith6517 Před 3 lety

    i have a bunch of those transformers out of apc they have high idle loses i wind my own i have a 70 pound core i am winding next 15 k

    • @PhdHung
      @PhdHung  Před 3 lety

      good

    • @ambersmith6517
      @ambersmith6517 Před 2 lety

      @@PhdHung i would like to try a diff transformer to lower idle amps

  • @TediChannel23Ja
    @TediChannel23Ja Před rokem +1

    change that noisy fan to a silent fan

    • @PhdHung
      @PhdHung  Před rokem +1

      Yes, this video is old. I currently have several newer devices replacing this UPS.

    • @TediChannel23Ja
      @TediChannel23Ja Před rokem

      @@PhdHung you have done a great job people need those informative videos 😊

  • @davidcromapix9083
    @davidcromapix9083 Před 3 lety

    the ups has 2 transformers, I can't understand which primary one connected the toroidal inductor to? Could you share a diagram of that connection? Everything else is clear, thanks for answering me and congratulatios on a job well done.

    • @josephsvensson6637
      @josephsvensson6637 Před 3 lety +1

      Pretty sure the transformers primaries are connected in series so it doesn't matter where you put the inductor, as long as its in the primary winding path

    • @davidcromapix9083
      @davidcromapix9083 Před 3 lety

      @@josephsvensson6637 Well , thank you very much for your reply.

    • @davidcromapix9083
      @davidcromapix9083 Před 3 lety

      @@josephsvensson6637 Could you tell me if the PC 40 toroids are the 30x20 T60 ferrite? there are many sizes. The user of the video explains briefly. Thank´s a lot !

    • @josephsvensson6637
      @josephsvensson6637 Před 3 lety +1

      @@davidcromapix9083 I can't tell by looking at them no, it would probably be best to experiment with some different ones if you have them, they don't have to be exactly the same to get the same result

    • @davidcromapix9083
      @davidcromapix9083 Před 3 lety +1

      @@josephsvensson6637 I am going to test different sizes of toroids and share the results here. Thanks

  • @user-fo9rx9py5e
    @user-fo9rx9py5e Před 6 měsíci

    Iam subscribed i need square wave convert into pure sine wave video

  • @samaranis6504
    @samaranis6504 Před 2 lety

    What's the importance of reducing no-load current?

    • @GotrekGurninsson
      @GotrekGurninsson Před 2 lety

      So it won’t drain your batteries while nothing is using it.

  • @linghuu2023
    @linghuu2023 Před 3 lety +1

    Cái 5000W inverter mà bạn sửa trong video khác nó mạnh hơn sao bạn ko lấy chế mà lấy máy ups này ?Dòng điện sin nó ko chuẩn bằng ups này hay lý do sao, 2 cái nó khác nhau gì vậy v.v.v

  • @DanielPerez-ye1uc
    @DanielPerez-ye1uc Před 3 lety

    hello i talk to you from chile, is in this case how do you charge the bateries ?...can i connect the solar charge regulator ?...and the other side how can i transfor my ups eaton 9130 in solar inverter ? greetings from chile

    • @PhdHung
      @PhdHung  Před 3 lety

      I use MPPT charger 45A. I think your UPS does the same thing.

    • @DanielPerez-ye1uc
      @DanielPerez-ye1uc Před 3 lety

      ​@@PhdHung yea, today comprove that, I thought about using it, but I was afraid that it could short-circuit the battery charging stage. That is why I opened the ups and I realized that in reality it is a continuous ups and it is only enough to remove the 220 VAC input and in that case the ups will recognize the charger, it only requires a 72VDC input. Thanks

  • @agungnugroho4329
    @agungnugroho4329 Před 3 lety +1

    can it use for on grid solar panel system ?

  • @HaiHoang-of6bn
    @HaiHoang-of6bn Před rokem

    Lồng tiếng vào bạn ơi video chỉ tiết lamg

  • @Ablegamerz
    @Ablegamerz Před 4 lety

    please can you upload an inverter that will work with TL494 PWM 50HZ to 100Khz Inverter 5000W. Thanks in advance

    • @zyga5441
      @zyga5441 Před 4 lety

      50Hz 100kHz

    • @petniyi35
      @petniyi35 Před 4 lety

      yes he uploaded a pwm circuit with TL494 a year ago and he didnt complete it

  • @andyjack2368
    @andyjack2368 Před rokem

    how much Amp your ups have is 30A or 15A out put I have 3000 watts pure sine wave 110V-120V 60Hz 30A

  • @tranthivan608
    @tranthivan608 Před 3 lety

    2 cục biến thế để kích điện hả bạn

  • @petniyi35
    @petniyi35 Před 4 lety

    we have been begging to make inverter with any of the pwm u posted since last year.
    u can even send us pcb for TL494 PWM OR SG3525. PLS it can be either modified wave inverter

  • @Buy610
    @Buy610 Před 4 lety +1

    Plengen...se nyoting ajoget

  • @haophan4774
    @haophan4774 Před 4 lety

    Mở bộ nguồn của anh đi anh

  • @trungvu9729
    @trungvu9729 Před 3 lety

    Anh quấn cuộn cảm như vậy đấu vào có cần can thiệp vào phần bo mạch không anh cám ơn anh

    • @PhdHung
      @PhdHung  Před 3 lety +1

      Không bạn. Minh chỉ cuốn để giảm dòng điện ko tải thôi

    • @trungvu9729
      @trungvu9729 Před 3 lety

      @@PhdHung cám ơn anh nhiều nó chỉ có tác dụng khi không tải còn khi có tải vẫn vẫn ăn dòng bình thường hả anh

  • @ambersmith6517
    @ambersmith6517 Před 4 lety

    I need a 48 volt external voltage regulator for a car alternator I will pay for a cad file

  • @SOLAR121
    @SOLAR121 Před 3 lety

    I need 24 volt 2200va solar inverter with in bilt mppt charge controller 80amper can you asambel for me please sand me prise

  • @HaiHoang-of6bn
    @HaiHoang-of6bn Před rokem +1

    Có video reset để đấu bình ác quy to ko báo ỗi pin yếu ko

    • @PhdHung
      @PhdHung  Před rokem +1

      dùng phần mềm powerchute reset cái là đc thôi b. Bạn lên shopee mua cáp kết nối cho nó đi rồi mình chỉ tiếp cho. Lên google tìm powerchute APC nó hướng dẫn cũng đc

    • @HaiHoang-of6bn
      @HaiHoang-of6bn Před rokem

      @@PhdHung mình thấy chưa ai làm video ấy.bạn up lên có lẽ nhiều luotj xem

  • @DineshPatel-xe3ll
    @DineshPatel-xe3ll Před 4 lety

    Thanks please emercen network power 1kva 36v convert 12v possible ??? Please reply

    • @zyga5441
      @zyga5441 Před 4 lety

      Alessandro Volta asks for the correct spelling of units

  • @samgriffiths1017
    @samgriffiths1017 Před rokem

    Hi how did you solve the low battery alarm after a set amount of time?

    • @andyjack2368
      @andyjack2368 Před rokem

      there speaker inside of it you take it out but ups sucks battery life not that long ok I have few inverter much better I have 500watts,800watts,1100watts,1500wats and 3000 watts inverter am building my own power station with few 20A Breaker and few 15A Breaker and few GCFI out let water proof tool box solar charger USB port etc

    • @samgriffiths1017
      @samgriffiths1017 Před rokem

      @@andyjack2368 I'm playing with a 5000w ups I got cheap. But i cannot find the annoying speaker !

    • @andyjack2368
      @andyjack2368 Před rokem

      @@samgriffiths1017 its there I could not find my own bud I did and just brake it out wich ups do you have I have ups 350

    • @samgriffiths1017
      @samgriffiths1017 Před rokem

      @@andyjack2368 APC sua5000rmi5u

    • @andyjack2368
      @andyjack2368 Před rokem

      @@samgriffiths1017 ok its small black thing have hole in it I have ups 350 I change battery have 3 12 volt lead acid 7.2 A and 20A 12 volt lead acid battery running my is 12 volt

  • @user-jw8hn6tc4f
    @user-jw8hn6tc4f Před 2 lety

    السلام عليكم عدنا APC بدناله بطاريات ويكهرب صار يخربط

  • @shiine3341
    @shiine3341 Před 3 lety +1

    cái đề giảm dòng không tải bạn mắc nối tiếp vào gọi là gì v b? cám ơn

    • @PhdHung
      @PhdHung  Před 3 lety

      Cuộn cảm 47uH nhé bạn.

  • @ntphuong3664
    @ntphuong3664 Před 3 lety

    Ông bạn này ở VN hả ?

  • @guywhoknows
    @guywhoknows Před 3 lety

    Where is the solar ?
    All you've done is put different batteries in a Inverter and showed it working.
    How are you going to charge the batteries from the solar array?

  • @KenanSatir
    @KenanSatir Před 2 lety +1

    Wrong battery connection for equal aging.

  • @thuytran967
    @thuytran967 Před 3 lety +1

    Bạn ơi cái lõi xuyến quấn bao nhiêu vòng vậy

    • @PhdHung
      @PhdHung  Před 3 lety +1

      tầm 3 đến 5 vòng là ok

    • @thuytran967
      @thuytran967 Před 3 lety

      @@PhdHung tại cái mạch của mình mới làm nó ăn mất 1A cho hệ 12v

  • @datluongvan5353
    @datluongvan5353 Před 3 lety

    Tôi thấy ups này có 2 bộ pin 24 vôn vậy điện áp đầu vào acquy là 24v hay 48v vậy bạn ơi

  • @sriparameshwariharvestersu8148

    Bro at least show ur bench power supply what's inside review ur bench power supply

  • @minhiep432
    @minhiep432 Před rokem

    Cho hỏi bao nhiêu vòng hạn dòng ạ? cảm ơn...

  • @huyhoang1592
    @huyhoang1592 Před rokem

    Con này đấu DC 80-96V chạy dc ko anh

    • @PhdHung
      @PhdHung  Před rokem

      Ko bạn. Max 60v thôi

    • @huyhoang1592
      @huyhoang1592 Před rokem

      Có cách nào nâng công suất hay dãi điện áp lên tầm mức 80-90Votl dc ko bạn

    • @PhdHung
      @PhdHung  Před rokem

      @@huyhoang1592 mua con khác thoi b

  • @TheHarmoniumTeacher
    @TheHarmoniumTeacher Před 3 lety

    What tran core and swg no plz help im waitng your reply

  • @hernanradulovich6441
    @hernanradulovich6441 Před rokem +1

    Hola no entendí para que el pones el toroidal ??

    • @PhdHung
      @PhdHung  Před rokem +1

      The no-load power of the APC2200 is 80W. After adding the inductor, the no-load power is ~40W.

    • @hernanradulovich6441
      @hernanradulovich6441 Před rokem

      @@PhdHung entonses se podría utilizar en cualquier UPS esa adaptación o sólo funsionaria con uno de 2200VA?

  • @kimnguutv9661
    @kimnguutv9661 Před rokem +1

    làm sao fix cho còi nó hết kêu thế người anh em ? giup nha tks

    • @PhdHung
      @PhdHung  Před rokem

      Đơn giản nhất là tháo còi nhé :D . Không thì bạn tải powerchute vè rồi cắm cáp và fix tắt còi. Hoặc khi nó đang chạy, bạn bấm nút ON 1 lần nữa nó sẽ tắt còi đến khi bình yếu.

    • @kimnguutv9661
      @kimnguutv9661 Před rokem

      @@PhdHung ok tks ngươi ae

  • @SOLAR121
    @SOLAR121 Před 3 lety

    You come from which country

  • @electroniccreative7683

    Please add indonesian subtitle language sir hehe i dont understand your language

  • @puriwatw.1323
    @puriwatw.1323 Před 3 lety

    where is part 2 video?