Sar bahut acche se samjhate Hain isliye cal main a raha hun aapke pass aapka number chalu rakhna band mat Karna sar jab main call Karen to receive karna jarur sar Nahin to ham bhatkate rahenge vahi
Sir namskar sir 1swal hai ager ham r32gas a c main Charing gej k hisab se kar te hai jese r32 ka back 115.120 rehta hai to wehat k hisab se gas kam dalti hai ager wehat k hisab se gas dalte hai 800gr900gr jo outdoor par di hoti hai to back presar jyada ho jata hai 145.150 k pas chla jata hai
Sir aap kitna accha batate hai. Mai aapse door rahata hu, or ek anadi mistri hu, bus jitna Gyan hai utna kaam kr deta hu. Kya aap distance cource krate hai. Online etc.
कोई भी फ्रिऑन गॅस पृथ्वीके ओझोन लेअरको हानिकारक होता है । ओझोन लेयर के कमी के कारण सुरजसे आनेवाली किरणोसे स्किन कॅन्सर होता है । और पृथ्वीका तापमान बढता है ।
Godrej 5star 1.5ton inverter ac hai company ne bataya 1400watt current legi par 2200watt current le rahi hai wajah kya ho sakti hai? usi jagah Panasonic ka ac lagaya wo 1400watt le rahi hai Panasonic sahi chal rahi hai
Are Sar Mujhe Galiyan dene per majbur mat karo aap ne 2:33 is ka Aage ka video cut Kar Diya pahle Sawal to clear karna tha key compressor ko kaise check Karenge Jaane Do main jawab de deta hun clamp metre se check Karenge compressor chalu hai ya band
Sir ji aap ke students keval sticker dekh kar hi gas dange jaha sticker nahi rahega vaha chod ke bhag jayenge log. Standing pressure check kar ke nahi dal payenge log 😂😂😂😂
Sir ji inverter ac 1.5 tan ka hai to uska ampers 7-11 agar lee raha hai to uska gas ok hai. Agar 7 ampers se kam lee raha hai to uska gas kam hai agar 11 ampers se jada lee raha hai to uska condensed chok hai apne students ko achhe se bataiye guru ji. Aap se hath jod 🙏🙏🙏 ke binti hai
Sir ji maine 2 ton ke ac me r32 gas charge kiya hai discharge line thnda ho rha hai magar suction line funda nahi ho raha Gas running pressure 130 pis dikha rha hai Our me seam 2 ac charge kiya hai 2 no milakr 1300 grm gas lagi hai to kya problem hua hoga pls bataye
Sir urban clap me humlog ko ye btaya hai ki amp5.75 se 9 amp me fluctuate hona chaiye agar gas puri hai to but gas charging ke baad sirf aapka4 amp aaya Kyu?
मेरा ac दिन में कूलिंग करना बंद कर गया है अपने आप बन्द हो जाता है samsung है डुएल इन्वर्टर है। गैस चेंज कर दी गई है वैक्यूम करके मिस्त्री कहता है इससे ज्यादा मैं कुछ नहीं कर सकता पहले एक नम्बर चल रहा था मैंने इसे अलग कमरें में शिफ्ट किया है।उसके बाद परेशान करने लग गया
Best way of doing work
Sir you are the Best Teacher on the world for me
From Pakistan
Sir aap bahut badhiya pdata hai 🎉🎉🎉🎉🎉🎉🎉🎉🎉🎉
Sir Thank you so much apki videos dekh dekh kar mera Ac teachnicain main selection ho gaya saudi arabia ke liye salry bhi achhi hai
Kitni salary hai
😅
Kitani selry hai
Hello bhai hame bhi le chalo
Jhut kyu bol rahe ho
Sir aap kitna achhe se batate ho dil khush ho jata hai ❤
Assalamolekum me jharkhandse
Outstanding explanation
Sir aap bahut achhi video banate ho 😊
Sir ji thankyou very much for your class related in AC i like so much 😂 please keep going so many videos in the topic
Sir your explanation is very good and easy
Very nice
Sir very good information
Veri nice information❤
❤❤❤❤ I'love you 💗💗💗 good man ❤❤❤
Good brother 😎
Thanks so much sir 😊
Sound issue, Mouthpiece nat a good quality, maybe mic to far from speaking area etc .😎
Thanku sir
Thank you sir
Sir inverter AC not working me kya kya chek kare is ka video banaye sir jaldi
Apka video content acha hai bhai,, ye btaiye inverter comprssor speed nahi pakadta to iska kya solution hai
Gas kam ya jadi hogi
Ac pcb problem hogi
@@kareemtechnicalmind8172 aacha ,, koi sensor issue to nahi ho sakta,kis sensor ko check kiya jae first
Nice sir❤
Sir oil changee karane ka video banao
Good job
Right 😊
Refrigerant Name
Standing Pressure
R-22
150-155 psi
60-70 psi
R-410a
225-230 psi
120-130 psi
R-134a
85-95 psi
12-15 psi
R-600a
40-50 psi
Below 0-1 psi
R-32
240-245 psi
110-115 psi
R-290
125-130 psi
R-407c
R-404a
R-417
65-70 psi
180-185 psi
75-80 psi
80-90 psi
180-185 psi
140 psi
Suction Pressure
65 psi
Discharge Pressure
Boiling Temp
250-300 psi
-40.8 C
450-500 psi
-51.4 C
-26.2 C
-11.7 C
-52.0 C
275-300 psi
-42.1 C
275-300 psi
-45.0 C
-46.2 C
261 psi
किसी भी इनवर्टर एसी का कनेक्शन करने का वीडियो बनाएं
Sir clamp metre se communication predical check Karke dikhaiye Hitachi me
Good
Sar bahut acche se samjhate Hain isliye cal main a raha hun aapke pass aapka number chalu rakhna band mat Karna sar jab main call Karen to receive karna jarur sar Nahin to ham bhatkate rahenge vahi
Ji han
Jaha rasta samajh nahi ayega wAha se call kar lijiye
@@kareemtechnicalmind8172sir number nhi chal rahe
Inverter model me out door unit me expensan vale ka kya kam hota hai btaiye
Inverter Lloyd AC mein running pressure 22030 hai kya karna hai sir
Sir standing pressure main nahin dalna hota hey aap standing pressure main kaise dalte hain
Sir good evening
Sir namskar sir 1swal hai ager ham r32gas a c main Charing gej k hisab se kar te hai jese r32 ka back 115.120 rehta hai to wehat k hisab se gas kam dalti hai ager wehat k hisab se gas dalte hai 800gr900gr jo outdoor par di hoti hai to back presar jyada ho jata hai 145.150 k pas chla jata hai
Oil change karke Dal sakte hain
Sir ji compressor kaa rpm kis sensor se control hota hai
Sir compressor nahin chalega to rela welpe change karna paraga
Sir
Vacuum like test ke liye digital meter chahye
Sir R410 ki jagah R32 Dal sakte hain
Yah chij kuchh compresser per likha hua hota hai
Kya yah baat Sahi hai ya galat
Please Reply
Nahi dal sakte hain
Sir aap kitna accha batate hai. Mai aapse door rahata hu, or ek anadi mistri hu, bus jitna Gyan hai utna kaam kr deta hu. Kya aap distance cource krate hai. Online etc.
Yahan log jo likh bhi nahi paate wo bhi technician bankar jaate hai ye samjhne par jyada depend karta hai
Kha me office hai bhai
@@SonuKumar-kw3zfu.p Aazamgarh mahrajganj me institute hai
Sir ac me gas charg kar ke
lock karna parta hy
कोई भी फ्रिऑन गॅस पृथ्वीके ओझोन लेअरको हानिकारक होता है । ओझोन लेयर के कमी के कारण सुरजसे आनेवाली किरणोसे स्किन कॅन्सर होता है । और पृथ्वीका तापमान बढता है ।
Sir Ji aapka Kolkata me koi technician hai? Mera ek dual inverter AC cooling bahut kam kar raha hai r32 gas wala. Please help
R410a hai guru ji 150psi nahi 130psi gas ka keval hons chahiye
Sir g Non inveter Ac men b esi trah full lequed Gass charging kreyn geyn kia? R410a
Yes
@@kareemtechnicalmind8172 thank you so much sir
❤
Compressor change and flashing indoor out door
Sar aap kon se state me sikhate ho
Up se
Helo
🎉🎉🎉🎉
Watch
Sir aapka office kahan
Sir ham tho 410 ki jagah 32 daal dete hai or 32 ki jagah 410
Godrej 5star 1.5ton inverter ac hai company ne bataya 1400watt current legi par 2200watt current le rahi hai wajah kya ho sakti hai? usi jagah Panasonic ka ac lagaya wo 1400watt le rahi hai Panasonic sahi chal rahi hai
Sir mujhe aapke pass AC technician ka kam sikhana
1:27 lloyad inverter AC main value 6.8a hain isme multimeter se kitne value tak gas fill kare
Are Sar Mujhe Galiyan dene per majbur mat karo aap ne 2:33 is ka Aage ka video cut Kar Diya pahle Sawal to clear karna tha key compressor ko kaise check Karenge Jaane Do main jawab de deta hun clamp metre se check Karenge compressor chalu hai ya band
panorama inverter ac me p6 error aa rha hai kya ho skta
Sir ji aap ke students keval sticker dekh kar hi gas dange jaha sticker nahi rahega vaha chod ke bhag jayenge log. Standing pressure check kar ke nahi dal payenge log 😂😂😂😂
Sir pahle wiltej chek krne h
R32 or 410 ka oil same hota h
410a ki charging line 3/8 ki nahi hoti hai 5/16 ki hogi hai aap ak baar dhayan dijiye
Right
Sr abhi bhi aapki system sahi se vacuum nhi huwa
Or 2 bat khas kr k inverter a.c gas charge jitna ho utana durse krana chahi ye
Sir aap ka institute kaha pe hai
Mujhe bhi aana hai
Why compressor making noice
Sir aap kaha sikhate hai
Address bataiye
Up azamgarh me
R 32 top-up kar sakte he ya nhi
Kar sakte hain
Mujhe bhi sikhna hai sir kaha pe hai apki shop
Up azamgarh me
Sir ji inverter ac 1.5 tan ka hai to uska ampers 7-11 agar lee raha hai to uska gas ok hai. Agar 7 ampers se kam lee raha hai to uska gas kam hai agar 11 ampers se jada lee raha hai to uska condensed chok hai apne students ko achhe se bataiye guru ji. Aap se hath jod 🙏🙏🙏 ke binti hai
Sir aap kha se ho
Up azamgarh se
Sir muje bhi course karna hai plz reply kar dejeye sir
Aa sakte hain
7355543798
Sir ji maine 2 ton ke ac me r32 gas charge kiya hai discharge line thnda ho rha hai magar suction line funda nahi ho raha
Gas running pressure 130 pis dikha rha hai
Our me seam 2 ac charge kiya hai 2 no milakr 1300 grm gas lagi hai to kya problem hua hoga pls bataye
Gas bada kar 150 psi pe kariye sahi jo jayega
Bhai 5.16 Ka hota hai 3.8 ka nahin hota hai
सर मुझको भी सीखना है ac का काम
कितने का कोर्स है
13500
Sir coching apka kaha hai
Up azamgarh me
Sar Koi discount Nahin chal raha hai abhi kya😂
R 32 gas charge kr sakte hain bhai R 410 me vacyum krne ke baad me kiyoki compressor pr mantion hota charge
Kha mansion hota he Bhai
Nahi
Nahi
Hlo sir ek baat puchni thi haier invater ac ke bare mai@@kareemtechnicalmind8172
V.nice information
.....
Sir aapka Institute kahan pe hai
Up azamgarh me
Mineral oil bad kansa gas...dalna bola...samaj nehi Aya..jarur batae ji...
R22
Thanks Ashu bhai
Sir agar vakum karne par -30 par aa Jaye to 100% likhege nhi hai
Agar likehse rhega to -30 pe nhi aayega
Aisa nahi hai
Kabhi kabha bahut miner leakage bhi hote hain
Apna address dejiye
Sir urban clap me humlog ko ye btaya hai ki amp5.75 se 9 amp me fluctuate hona chaiye agar gas puri hai to but gas charging ke baad sirf aapka4 amp aaya Kyu?
Jaroori nahi hai ki amp kam jada ho
@@kareemtechnicalmind8172
Mera matlab 5.75 se 9amp ke bech me kuch bhi ho jaise 6, 6.25, 6.65, 7, ya 8 kuch bhi
Dhankn to lga liya hota😂😂😂
आपका इंस्टीट्यूट कहा pe hai
Up azamgarh me
Sir ager standing pressure Bata Raha h aur back pressure 0 Bata Raha h Kya problem h
Half choke ki problem hogi
Kya cheez chok h
Choke bro
मेरा ac दिन में कूलिंग करना बंद कर गया है अपने आप बन्द हो जाता है samsung है डुएल इन्वर्टर है। गैस चेंज कर दी गई है वैक्यूम करके मिस्त्री कहता है इससे ज्यादा मैं कुछ नहीं कर सकता पहले एक नम्बर चल रहा था मैंने इसे अलग कमरें में शिफ्ट किया है।उसके बाद परेशान करने लग गया
Sir certificate mil jayega
Kam ana chahiye mil jayega
@@kareemtechnicalmind8172kitna Paisa lagega
Mujh se le lo trening free me balki my pese dunga sekhne ke or degri be dunga
Pagal Mt bnao kisi ko
Me tere ko ak number bhi nhi du kya rong smja rha h ldko ko phle ache se trainings le khi ja ke
Iss me wrong kya hai ye bhi to bata do
Ye bakchodi hai
नये बच्चोको सिखा रहै हो तो उनको गॅस उडाने को मत सिखाईऐ . गॅस रिकव्हर करने को सिखाओ .🙏🙏
Sir apka number mil sakta hai
Sir aap mujhe apna contact number de sakte ho
Good
Sir gass ka paressar pura hai lekin ampiyar nahi aaya to kya paroblam hai
Agar ac cool kar rahi hai to Kuchh problem nahi