Ac On kar Ke Compresser full Running pe Aa Jaye 5min ya 10 chalne ke Bad Discharge Line Band (Patli pipe) L-key Se Band Kar do Phir Agar Pipe Ki lamdai Ya Indoor Se Outdoor Door hy to 5 wait kr lo uske bad suction Line bhi Band Kar do Is Tarah Gas Restore ho jayegi
किसी किसी नान इन्वर्टर एसी स्प्लिट एसी में आउटडोर में भी पीसीबी होता जिसमे odu मोटर डीसी करेंट से चलता है। और उसमे एंबियेंट temp सेंसर भी लगा होता।hitechi के एक दो माडल में होता।
Aapka kahana hai inverter AC mein r22 gas nahin dhalti but Mera kahana hai inverter AC mein r22 ka model Maine khud dekha hai Daikin company ka old model r22 mein vah system work kar raha hai
Uvw ko Apne wire ke anusar hi lagana chahie u ka w mein u v mein nahin Laga sakte Jo print compressor ke upar uvw ka hota hai vahi print PCB card ke andar bhi uvw ka likha hota hai kabhi check karna aap log
Assalamualaikum Sir Mera sawal hai Kya inverter ac ke out door PCB ke kharab hone par non inverter ac ka outdoor Laga sakte hai contactor Wala out door Please Sir answer me Bahut mehrabani hogi Please
sir inveter ac mai splite ac or window ac ka kam krta hun or 1 bar kya hua kise karan se compressor ka kam rahe the tab compressor main likha hua tha 220 v ac or aap bol raha hai ki non inverter ac likha huta hai
Helo bhaiya ek window ac hai on inverter ohhh baar baar uska gass lek ho ja rha hai usko kise thik kare aur jaha se Belding karte hai naa wahaa se lek nhi hota hai kise aur jagah se lek ho jata hai kaise thik kare😂😂😂😂
Aapka video bahut hi achha lagta hai
Thank you sir ji
Thank. U Kareem Bhai
Nice video sir 🙏ji ❤
Thanks best information
Great information
Kareem bhai padane ka satyle bahut achha hai 🎉🎉
Sir split AC shifting ke time gas store kaise kare please bata do
Ac On kar Ke Compresser full Running pe Aa Jaye 5min ya 10 chalne ke Bad Discharge Line Band (Patli pipe) L-key Se Band Kar do Phir Agar Pipe Ki lamdai Ya Indoor Se Outdoor Door hy to 5 wait kr lo uske bad suction Line bhi Band Kar do Is Tarah Gas Restore ho jayegi
अधूरा ज्ञान मत दोंभाई खतरनाक हो सकता है@@vakeelhashmi1519
Sir ji Daikin inverter 22 use old model me Kiya hey
DC phase U, V and W used in AC motors to represent because in india using brites standard
Good sir g
Very nice sir ❤❤❤❤
Sar vacuum pump mai single stage and double stage mein kya fark hai
Double stage jaldi vaccum kar dega
Kab batayenge bhaiya charo ke bare me bataiye please please please please
Bahut achchhi video hii sar aapki
Chiller plant pr video btaiye sir
Nice important Topic ⭐
Purane ac me non inverter ac ke outdoor me condensor ke output me sensor lga hota he
Hp switch hoti hai high pressor hone pe compressor ko band kar deti hai
Sir aap regular class open rakhte hai
Sir ji inviter ac pcb ke upar video 📹 upload 📹 karo sir ji
किसी किसी नान इन्वर्टर एसी स्प्लिट एसी में आउटडोर में भी पीसीबी होता जिसमे odu मोटर डीसी करेंट से चलता है। और उसमे एंबियेंट temp सेंसर भी लगा होता।hitechi के एक दो माडल में होता।
❤2good🎉
Ghr khha pe hai
Sir it will be better if u Write in Hindi
Hi sir how are you
Fine
Sir kab se class start huaa hai
Aapka kahana hai inverter AC mein r22 gas nahin dhalti but Mera kahana hai inverter AC mein r22 ka model Maine khud dekha hai Daikin company ka old model r22 mein vah system work kar raha hai
Inverter compressor three phase ka hota hai jaise AC motor winding 3 phase ki hoti hai waise hota hai star delta connection
Sir parts ki checking aur falt finding & questions answer pe बनाइए
Sir dubule door fridge me inverter technology or non inverter technology me kya antar hai please batay sir
Sir aazamgarh me iti college hai
Good afternoon sir
Me online class karta hu or class Puri ho chuki hai hame satick fitick chahiye
3000 ka kharcha ayega
May ka batch kab se shuru hoga
Sir AC service ke time PCB nikalna jaruri hai ya nahin
Nahi
Achchhi tarah pcb ko dhak dijiye
Bhai AC Sarvice karte time Pcb nikalna important hai kyuki Usme Pani chal Jaye ga na to kharab ho Jaye gaa
Uvw ko Apne wire ke anusar hi lagana chahie u ka w mein u v mein nahin Laga sakte Jo print compressor ke upar uvw ka hota hai vahi print PCB card ke andar bhi uvw ka likha hota hai kabhi check karna aap log
Assalamualaikum Sir
Mera sawal hai
Kya inverter ac ke out door PCB ke kharab hone par non inverter ac ka outdoor Laga sakte hai contactor Wala out door
Please Sir answer me
Bahut mehrabani hogi
Please
Nahi laga sakte
Inveter ac 0 amp se start hoti h sir
Inverter AC se nuksan ho skta h kya
Sir Accumileter ka karya kya he
Compressor me liquid gas jane se rokta h
Nami , jane se rokta h
Gas filtar karta h
Service ke kitne der bad chalana chahiye ac
Kam se Kam 2 ghante
Sir aap ka WhatsApp group hai sir
Sir aap khha se hai
Up azamgarh se
sir inveter ac mai splite ac or window ac ka kam krta hun or 1 bar kya hua kise karan se compressor ka kam rahe the tab compressor main likha hua tha 220 v ac or aap bol raha hai ki non inverter ac likha huta hai
Ham ne kabhi ye bola hi nahi
Ham to ye bolte hain ki inveter ac pe inverter ac likha rahega
Non inverter pe kuchh nahi ikha rahega
Isko bhejo mere paas
Sir, how to contact I need your help.
7355543798 only cou
Hvac ka course bhi saath me hota hoga sir karna hai
No
Assalamualaikum sir kaise Hain
Walaikum assalam
Boxx drkh kar hi kese pta kre ki ac inverter he ya non inverter
Out door me pcb rahegi inverter me
Aur likha bhi rahega
Helo bhaiya ek window ac hai on inverter ohhh baar baar uska gass lek ho ja rha hai usko kise thik kare aur jaha se Belding karte hai naa wahaa se lek nhi hota hai kise aur jagah se lek ho jata hai kaise thik kare😂😂😂😂
Pipe spire ho gayi hogi
R22, 2030 k bad totally band, new ac me r22 refrigerant nhi hoga
R 32 hoga
Sir online course h
Yes 7355543798
Godrej campany ka splite ac the
सर आपका कॉन्टेक्ट नंबर चाहिए
7355543798 only course enquiry
सर आपसे बात करनी है
Sir number snd me
7355543798
Sir split AC shifting ke time gas store kaise kare please bata do
Video bani hai
Link send karo sir