HVAC RTU maintenance | Inspection

Sdílet
Vložit
  • čas přidán 10. 09. 2024
  • Company did install few months back. Doing a maintenance/ inspection on the equipment we installed. #hvac #hvaclife #skilledtrades #bluecollar #milwaukeetools #veto #vetopropac #knipex #fieldpiece #testo #kleintools

Komentáře • 43

  • @123Lookatmrlee
    @123Lookatmrlee Před měsícem +1

    My first rtu maintenance is tomarrow. Ill be up on the roof watching this for sure

  • @themayorofairconditioning2868
    @themayorofairconditioning2868 Před měsícem +2

    Thanks bro. I only do residential, but going to do my first RTU maintenance next week.

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před měsícem +1

      Hell yeah!! Just approach like a package unit/split system, but just a box and you’ll be good 🫡

    • @sickmike0739
      @sickmike0739 Před měsícem

      How was it?

    • @themayorofairconditioning2868
      @themayorofairconditioning2868 Před měsícem

      It was great. Got to look everything over, check the charge and delta T on both stages, clean the coils etc. they asked to come back for the next PM. However there were alot of wasps and a few nests inside which really slowed me down. I'm going to have to get more experience dealing with them.​@@sickmike0739

  • @hanziehummer
    @hanziehummer Před 9 měsíci +1

    straight to the point, clear and accurate, good video. subbed

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 9 měsíci

      Thanks for that! Appreciate it!!

    • @hanziehummer
      @hanziehummer Před 6 měsíci

      @@KoolinwithKrauss hey bud i service units in a commercial setting but they are inside would you do the same process?

    • @hanziehummer
      @hanziehummer Před 6 měsíci

      split system carrier units but none of them are on the roof top just at ceiling grid.

    • @hanziehummer
      @hanziehummer Před 6 měsíci

      @@KoolinwithKrauss also what were you checking with your multimeter?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 6 měsíci +1

      Go about it in the same way imo! I just was checking the volts and amps. Also for split systems bit of a pain because 2 separate components to deal with. But just check over it all!

  • @renecuevas4128
    @renecuevas4128 Před 6 měsíci +1

    I see your Boots you are hired my bro. ....we only hire Techs with rite Apparel and shoe prot....ozr motto here...love your inspection routine and total job ettics....Tnks

  • @gingerlansinger4035
    @gingerlansinger4035 Před 2 lety +1

    Lol jake in the box in beginning of video…great job jake

  • @deavonsanchez3084
    @deavonsanchez3084 Před 7 měsíci +2

    Yall get pressures and clean coils on quarterly? We never clean on quarterly or get pressures

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 7 měsíci

      Yeah we check them all as SOP for all maintenance, ensure that we’ve done what we needed if something happens between services

  • @mrtonge5323
    @mrtonge5323 Před 4 měsíci +1

    Great job

  • @user-wn1qs9rw8b
    @user-wn1qs9rw8b Před 5 měsíci +1

    I have a question feel free to not answer. When you go do quarterly maintenance do you always clean the coils or do you have to get it approve by the customer? Anyways great video, it’s always cool to see what other techs do during there maintenance.

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 5 měsíci +1

      So we give them a good rinse. I use a little sprayer and spray er down even if it’s just “soft wash” appreciate you watching 🫡

  • @renecuevas4128
    @renecuevas4128 Před 6 měsíci +1

    Only thing i do not like is Microchannel Cond Coil here in Fl are not very efficient ..my IMHO

  • @PBS-nm1uu
    @PBS-nm1uu Před 2 lety +1

    just found your site please do sequence of operation, thanks

  • @scrambler350
    @scrambler350 Před 7 měsíci +1

    Have you had to replace one of those Axial Blower Motors on a TRANE yet....?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 7 měsíci +1

      I have not had the fortunate opportunity yet!!

    • @scrambler350
      @scrambler350 Před 7 měsíci

      @@KoolinwithKrauss
      We're doing a 2nd one (did one a couple years ago) soon, and was hoping you'd done a few of them and had an easier way that pulling the whole top off.
      We're not a TRANE dealer, we have Carrier with the 'Eco Blu' fan motors on the small RTU's - it's less than a 5min job to replace the blowers on those.

  • @chainoflakesrefrigerationa2906

    Pit vipers on point

  • @karakrauss5276
    @karakrauss5276 Před 2 lety +1

    nice job bud.

  • @quantumrealmtourist71
    @quantumrealmtourist71 Před rokem +1

    At 2:09 are those hex bolts you’re taking out?

  • @RedNeck.Civilian
    @RedNeck.Civilian Před rokem +1

    How much time do you get for a pm😭 i get 48 min a unit

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před rokem +1

      As long as it takes really. Never really timed. Kind of up to “ our discretion” 👍🏻

  • @ChosenSpi
    @ChosenSpi Před rokem +1

    What kind of shades do you have on

  • @ArcolaBridge
    @ArcolaBridge Před 5 měsíci +1

    What's the best rtu? Trane?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Před 5 měsíci +1

      They make good ones, yorks are good, carriers. I don’t work on many to have a deciding favorite