How to set up a Ferroli boiler

Sdílet
Vložit
  • čas přidán 25. 08. 2024
  • Press reset until" ts" then let go
    Press reset and let go till p01 appears
    Bottom + and - scrolls the parameters
    Top + and - let's u see the value ....and to adjust the value of that parameter
    Parameter 1 = ignition pressure % (20-25)
    Parameter 2 = ramp rate 2 0r 3
    Parameter 5 = temperature Set point °c
    Parameter 6 = output % (needed requirement)
    Parameter 8 = delay after hotwater for heating (10 secs
    Parameter 11 = pump overun ,10 secs
    Parameter 12 = hotwater output 85%
    Note "Gas rate" boiler first to get correct readings gas pressures and temperatures for the bench mark book .....then adjust the parameters to suit the system and requirements .

Komentáře • 40

  • @bonniebundle6692
    @bonniebundle6692 Před 3 lety +1

    Thanks for you easy to understand videos. I moved house to find a ferrol boiler. I soon found that the buttons were the wrong way round on mine! Once I'd worked that out, with your help I've reset my boiler a few times. The reset button doesn't reset though on mine😂🤣quite a challennge

  • @m.m.5444
    @m.m.5444 Před 7 měsíci

    Ti giuro mi hai salvato la vita,ho fatto esattamente come te,e funziona adesso la caldaia. Ti rigrazio 🎉

  • @odioofficial1
    @odioofficial1 Před rokem

    Hello thank you I followed just what you did and it works fore perfectly.... The water 💦 is hot but I needed to also fix the heater please I want you to redo a video on how to fix the heater.....I called the technical man they ask about 100euro to fix it

  • @TudorRAP
    @TudorRAP Před 8 měsíci

    I've set it up properly now but I still get lukewarmish water; also, if I use hot water for 20 mins then stop it and then start it up again, I get even colder or just plain cold water. Another issue is the bathroom sink doesn't even start the boiler at all for hot water, the request doesn't "register".
    Did I mess up the settings? Could it be about pressures or compensation curve/curve offset? (maybe a good idea to make a video on those regardless if that's the case for me or not?)
    Anyway, thank you so very much for your videos!!

  • @ClayDavis90
    @ClayDavis90 Před 9 měsíci

    Any idea what about an f47 issue on an ferroli optimax he-2s?

  • @Ranjitsingh-on8jw
    @Ranjitsingh-on8jw Před 5 lety +1

    Hi Dave what are these boilers like for reliability long term
    do they have copper heat exchangers?
    seems they need setting up well?
    many thanks for the video

  • @boinaverde1975
    @boinaverde1975 Před 4 lety +1

    Hi Dave any chance of get the parameter list, got a 26c just change the pcb and its crazy all over the place

  • @craigrees172
    @craigrees172 Před 4 lety +1

    P11 is showing 00 and the highest I can go is 05. Everything is else is okay. I have the Ferroli DOMIcondens HE 26 C. I have a fault code of f34 which means not enough voltage flashing. 1st it was f37 which meant low water pressure which has been resolved. Could this be anything to do with settings? I appreciate the help. This happened after my power supply went off.

  • @jozsefesztan8342
    @jozsefesztan8342 Před rokem

    Hi, I have a ferroli domicondens he 26c. Can you tell me how old it is? We just moved into a new house and we have this boiler. I;m not sure how reliable and worth to change to a newer one. Thanks, Joe

  • @matthewharris1510
    @matthewharris1510 Před rokem

    Hi have you a video on how to set up a Modena 32C HE 👍

    • @theferroliman2067
      @theferroliman2067  Před rokem

      You don't need to set up that model... It's only because the heatexchanger is smaller in the one shown ... If anything change parameter 17 to zero on the modena for the hotwater delay .so the heating comes on quicker

  • @ugurbeter1760
    @ugurbeter1760 Před 2 lety +1

    Merhaba Ferroli ecoconsept 25c-35c kombi kullanmaktayım. Kombi petekleri ısıtmaya başladığı zaman 38 c kadar düşük Alev modunda ısıtma yapıyor sonra duruyor. Alevin yüksek ve daha fazla dereceye ulaşması nasıl yapılır teşekkür ederim.

  • @mightymerlin128
    @mightymerlin128 Před 5 lety +1

    Hello. Thank you so much for all those information. They're really appreciated.. Could you help me with my ferroli? I did all the parameters you said and it worked great but soon after the water Is not that hot anymore. It only rise up to39 c and then drops down again to 34 c. What is the reason for that?

    • @jaxtynpierce5731
      @jaxtynpierce5731 Před 3 lety

      Dunno if anyone gives a damn but if you guys are bored like me atm you can watch all the new movies on InstaFlixxer. Been streaming with my gf lately =)

    • @zakaialfred9543
      @zakaialfred9543 Před 3 lety

      @Jaxtyn Pierce Definitely, I've been watching on Instaflixxer for since december myself =)

  • @halimak625
    @halimak625 Před 3 lety

    Hi... please help.. my smart portable themostat needed new batteries and now the manual setting i used to use has now gone haywire... the boiler keeps flashing sporadically and only stops when i press reset on boiler but its happening a lot... i cant get heating to come on ( as i do not want a programme) i want to do manually as and when needed. I have manual for heating settings but still boiler flashes arrrrhhhhhhhh

  • @karlnewton2690
    @karlnewton2690 Před 5 lety

    Hi Dave do you have the parameter settings for a ferroli optimax he

  • @andystodulski814
    @andystodulski814 Před rokem

    Hi there, I have Optimax 38c and I have not been able to find any source of information anywhere on these settings codes description and what the defaults are. Even ferrolli company is ignoring me. Any suggestions?

    • @theferroliman2067
      @theferroliman2067  Před rokem

      Just to note this video isn't for your model boiler . ..
      There's a couple of settings that you can adjust.
      To see how to use ..type in CZcams "how to use a Ferroli boiler. "
      If you type ferroli optimax he 38c pdf .you'll get a manual that u can download.

  • @mohamedmatmati5601
    @mohamedmatmati5601 Před 2 lety

    merci bbbb

  • @sunnisembhi6418
    @sunnisembhi6418 Před rokem

    Hi I have had by boiler off for around a month whilst changing my bathroom. It's now not running with the error code f40 ? Any ideas ?
    Much appreciated

    • @theferroliman2067
      @theferroliman2067  Před rokem

      Depends on the model u have f40 is normally that the pressure is too high ..
      Needs to at 1 bar when cold

  • @jnrshane
    @jnrshane Před rokem

    Have u got how to set up a euroterm plz as the perimeters seem slightly different 👍🏻

    • @theferroliman2067
      @theferroliman2067  Před rokem

      It depends what euroterm model u have ...if it's a e27 or e32 then u dont need to adjust them

    • @jnrshane
      @jnrshane Před rokem

      @@theferroliman2067 e32 plus i am a gas engineer but not realy messed with ferroli much

    • @theferroliman2067
      @theferroliman2067  Před rokem +1

      @@jnrshane that model you have has a large heatexchanger...and it's set at 80 % anyway for output . The one in the video has a really small heatexchanger which is prone to problems if it's not set up correctly.

  • @Tech01one
    @Tech01one Před 2 lety

    Can you show me how to reset a boiler pressure on ferroli mega dens 4

  • @bazbazzler188
    @bazbazzler188 Před 5 lety

    What about the Modena 32 he please

  • @derekreed6798
    @derekreed6798 Před rokem

    Do you have a similar video for T-ONE 30C HE?

    • @theferroliman2067
      @theferroliman2067  Před rokem

      There is no real adjustment that need doing on that model boiler . The adjustments on this boiler on the video actually save leaks on the heatexhanger if it's only on a very small system.
      There is a video of how to use a ferroli boiler . The buttons mean the same it's just they are arranged slightly different

    • @derekreed6798
      @derekreed6798 Před rokem

      The boiler works fine in the winter. But in the summer when the heating isn't on, the hotwater just goes cold after a while and the flame just keeps going on an off.

  • @craigrees172
    @craigrees172 Před 4 lety +1

    And my error code is f34 ☹️

  • @haliltaskinsu1688
    @haliltaskinsu1688 Před 3 lety

    How do switch off heater on boiler just need hot water

    • @theferroliman2067
      @theferroliman2067  Před 3 lety +1

      If u have a clock u should be able to turn it off ...or try turning the temperature down to minimum on a wall roomstat or on the boiler temperature button turn to minimum ... Note certain boilers have diverter valves and it could be passing and heating up the radiators when u use a tap .

  • @bilelkhalfaoui4430
    @bilelkhalfaoui4430 Před rokem

    M'y error cod f7

  • @amarsadoun5200
    @amarsadoun5200 Před rokem

    Bjr pourriez vous me traduire en français SVP?

    • @theferroliman2067
      @theferroliman2067  Před rokem

      tu as quelle chaudière ? car il s'agit d'une gamme de chaudières spécifique. cela ne fonctionnera pas sur tous les modèles de chaudières ferroli

  • @mohamedletlout9453
    @mohamedletlout9453 Před rokem

    Erreur a02 pour chaudiere Ferroli

  • @islamoran-yw4rm
    @islamoran-yw4rm Před rokem

    code err FH svp

    • @theferroliman2067
      @theferroliman2067  Před rokem

      Fh isn't a fault code ... It's the set up procedure maybe when the power is turned off or u had a fault and it's reset itself.