D.I.Y how to Wire a 3 phase motor to single phase 240v the easy way

Sdílet
Vložit
  • čas přidán 25. 04. 2020
  • How to wire a 3phase motor to single phase 240 volts with a capasitor
  • Jak na to + styl

Komentáře • 37

  • @MacheteBushcraftAustralia

    Thank for the info mate.
    A normally open momentary switch would be a good swap for that toggle switch (for the forgetful people, myself included!).

  • @kevinbucner2739
    @kevinbucner2739 Před 3 měsíci +1

    how much power do you loose by running on single phase

  • @ryanschumaker6286
    @ryanschumaker6286 Před 3 lety

    If I have a motor being used for a hoist that has a very small run time, can I just use the two capacitors like you said? Being this is under load on a start I believe I will need two, but I don’t want to use that switch every time I have to hit the “up” button

  • @sifarcher
    @sifarcher Před 2 lety

    Hi, please help! I measure 420V between two wires, how can change this back to 240V? It was wired for using a 3 phase pump but am wanting to run a single phase pump now. Thank you.

  • @npaisnel
    @npaisnel Před 7 měsíci

    Nice one mate, cheers. Regarding two capacitors and starting. I have not found it yet, but you can wire two capacitors, no switch, both caps wired to two different places. Start and Run capacitors…. No need for a switch… not found any wiring info yet.. I’ll post back if I find anything… and I can find your video again… if you find info before me.. can you do the same
    Cheers

    • @npaisnel
      @npaisnel Před 7 měsíci

      Ah no!
      I found the wiring pics for twin capacitor, no switch … and it was for motor with built in centrifugal switch 🙁

  • @rileyboult5383
    @rileyboult5383 Před 3 lety

    what would i want for 1.5kw and 50hz?

  • @collinskimani7197
    @collinskimani7197 Před 2 lety +1

    Hot to calculate that size of capacitor

  • @charlesmwangi164
    @charlesmwangi164 Před 3 lety

    Demonstrate by connecting the two capacitors

  • @ravindralakhimale35
    @ravindralakhimale35 Před 3 lety

    Am kv 0.5/ 0.37 amp tree phase moter signal phase pe chalane ke liye capacitor kitne vatt ka lagau

  • @gbrecycle8347
    @gbrecycle8347 Před 2 lety +1

    Hi, if i understand well, my 3 phase motor have 3hp (2.2kw), i need starter capacitor of 120?

  • @sanjayakumara7145
    @sanjayakumara7145 Před 3 lety

    great video .i have 200v japanese oilpump motor which came with three wires. is that a three phase motor? and is there any way to convert it runs with 230v single phase?

  • @jerryjurs7519
    @jerryjurs7519 Před 6 měsíci

    Is it as stromg as if it was running at 3phase?

  • @easywaycircuit9233
    @easywaycircuit9233 Před 3 lety

    what capacitor your using ( running or starting ) like 3ph 3hp motor

  • @swordfish1120
    @swordfish1120 Před 2 lety

    When u initially started the motor, and it did not have enough power to turn, it was connected to a 240v outlet? The end result was that u were able to convert a 3ph 240v motor to single phase 240v motor? Have u ever tried this on a servo motor?

  • @OKVanAutoUpholsteryBellGardens

    how do you calculate kw? my 3 phase motor doesn't state the kw, its a 3 phase wired for low volts and states 8.6 amps at lo volts , cycles 60, rpm 1200.....what type of resistor do i need to wire up to single phase 220 volts system?

    • @justpanit9872
      @justpanit9872  Před 3 lety

      Hmm, I'm not sure without having kw stated. If I can work it out I'll let you know.

    • @OKVanAutoUpholsteryBellGardens
      @OKVanAutoUpholsteryBellGardens Před 3 lety

      @@justpanit9872 i believe its a 1.892 kw

    • @justpanit9872
      @justpanit9872  Před 3 lety

      About 270 ųf 400v starting capacitor. But keep in mind. If you do find one able the run this motor keep a close eye an temperature Incase it starts to over heat. Good luck.

  • @nickthompson5516
    @nickthompson5516 Před 3 lety

    i have a 3phase motor and its 3HP. i wired from star to delta connection 240volts. What capacitor ( run or start) and what size capacitor?

    • @justpanit9872
      @justpanit9872  Před 3 lety +2

      O.10 kw you need a 7ųf start capacityor with a 50/60 hz motor. For example if you have a 0.30 kw 50/60hz motor you will need a 21ųf capacitor or close to it. You will have to work it out as I can't work out horse power for you.

    • @jomarchannel
      @jomarchannel Před 3 lety

      150 uf or above

  • @Atil1985
    @Atil1985 Před 3 lety +1

    Morning sir,...how about sir 3ph motor,convert to single phase,..what capacitor I used sir?

  • @adrianeumague9692
    @adrianeumague9692 Před 3 lety

    In 10Hp 3phase motor how many micro farad is required (rating) for running capacitor ? Thanks

    • @anthonyfoster7206
      @anthonyfoster7206 Před rokem

      Hi buddy did you work out what capacitor you need ?

    • @75Robert
      @75Robert Před rokem

      @@anthonyfoster7206 I would like to know what Farad cap to use

  • @manjulakarunathilaka7949

    How to calibrate the capacitor value

  • @dejonedenzel2897
    @dejonedenzel2897 Před 3 lety

    Can that work on compressor

  • @leiladaquil6587
    @leiladaquil6587 Před rokem

    Me