How to run 3 phase motor on single phase supply / single phase to 3 phase converter / 3 phase wiring

Sdílet
Vložit
  • čas přidán 15. 01. 2022
  • How to run #3_phase_motor with #single_phase_power supply.
    Working principle of #3_phase_induction_motor with #single_phase_motor_connection is explained here, with fine animation work.
    If you do not have a #single_phase_to_3_phase_converter, this method can be used to run a #3_phase_motor by connecting a matching capacitor as shown in this video.
    How ever this method should only be for test purposes of a 3 phase motor or for operating for short periods of time, when 3 phase power is not available.
    If you intend to run it for extended periods, it's best to go for a different option with #3_phase_motor_connection.
    If this video is helpful, please subscribe the channel.
    Thank you.
    #capacitor_start_capacitor_run_motor #singlephase_induction_motor #3_phase_wiring #working_principle_of_3_phase_induction_motor #motorstarter #3_phase_to_single_phase_converter #home_wiring #3_phase_wiring
    #dol_starter

Komentáře • 118

  • @ElectroAcademyEA
    @ElectroAcademyEA  Před rokem +6

    Hi everyone,
    Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈
    It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you.
    You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy
    I made this request six months ago, but no one has come forward to help this channel yet.🤔💔
    I know, many have become patrons of entertainment channels mainly, but look forward to seeing at least some supporters who understand the value of an educational channel like this.
    If you are not willing to visit a particular website for help, please contact me via email, sudarshan78@gmail.com
    Your kind gesture will be most welcome..!❤❤❤
    Thanks and Best regards.
    Sudarshan,
    Creator of Electro Academy Channel.

  • @andersemanuel
    @andersemanuel Před 8 měsíci +7

    This was the BEST presentation! With the windings shown it is easy to remember what one is actually doing. Thank you so much ❤❤

  • @selfmade128
    @selfmade128 Před 3 měsíci +2

    This was the most straightforward and well explained and demonstrated example I have seen on YT! Great work, thanks!

  • @HappyLacrosse-wg5mq
    @HappyLacrosse-wg5mq Před 3 měsíci +2

    Superb and fantastic explanation and can understand very easily. Thank you very much

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm Před 6 měsíci +3

    Sir your explanation way so simple to understand thank you ji 🙏

  • @iikmubarakachmad3054
    @iikmubarakachmad3054 Před 10 měsíci +3

    Thank You
    this is very useful knowledge
    for our needs in the countryside

  • @Walkercolt1
    @Walkercolt1 Před 11 měsíci +3

    I ran a three phase motor off single phase 220 volt AC (actually 250 volt) for nearly thirty years with a ROTORY contactor that was 1930's vintage, just like the 230 volt 3-phase Westinghouse motor on the Quincy 7 1/2 HP (? maybe 10 HP) two-stage three-cylinder air compressor with a 90 or 110 gallon ASTME tank I got used from a filling station, and sold a few years ago for twenty times what I paid for it to a fiberglas shop, and the buyer thought he STOLE it compared to a new compressor! He'd have to have bought an EPA "compliant" screw compressor new and HAD it installed. HE could install my old Quincy outside in a shed legally. I had never connected the water intercooler, but he did and it was fine. Mine wasn't a delta three-phase, it was a "star" three phase. I DID have to replace the "RUN" capacitor which bulged and leaked from age-a $120 item and while I was into it I replaced the three Vee-belts that were twice my age. It was an induction run repulsion motor that made the electric meter "JERK" violently when each pole of the motor passed, but it will probably run until 2134 when I think it was built in 1934! Yes, a modern Toshiba or Baldor could save some electricity, at the expense of motor-life. You don't get anything for free in life. I used to pump it up to 175 psi and shut it down and "run off the tank" all evening, and sometimes the next day! Oh, yeah, I forgot I had to re-build the second stage compressor early on-the poppet valves stuck and snapped, but I think it was about $50 to fix it from Quincy Parts, and no harder to fix than a lawnmower.

  • @landlordnation
    @landlordnation Před 10 měsíci +2

    Good Job! I learned something today!

  • @peterrhodes5663
    @peterrhodes5663 Před 10 měsíci +2

    I use that basic circuit on my milling machine. What is shown won't have much starting torque, and you'll need a start capacitor of up to 8 times the value of that run one momentarily connected in parallel with it. Also don't expect to get the rated output of the motor, because if you monitor the actual voltage across each phase, only the one between phase and neutral will be correct. One of the others will be higher, and the third lower, and the values will vary, depending on the load that is being driven. The start capacitor has the maximum number of starts/hour written on it. Exceeding that will produce magic smoke, and the necessity for a trip to the capacitor shop. Mine doesn't use that fancy relay, and uses old power factor correction capacitors for the run function.

  • @MuttMuttOutdoors
    @MuttMuttOutdoors Před 11 měsíci +5

    I was once at a shop that a guy had built and setup but only had 220 single phase power available because it was in a residential area. He was able to start and run 3 phase motors on 220 without a capacitor. It's a bit spooky but he would wrap a rope around the pulley and pull start the motor. Once it's running over a certain RPM it will run on 220 single/split phase so pulling the rope like starting a lawn mower would get the RPM up and then throwing the breaker once it was spinning would get it up to about full speed.
    Also once a single motor was running he was able to take the 3rd leg and use that to start other electrical motors that were 3 phase without using the pull start method. So he had multiple 3 phase motors setup on equipment with a line that linked the 3rd leg of each one together and starting up the shop from cold was a process of starting one motor with a rope and then just throwing the switch on anything else he wanted to run.
    An added bit of information that I can not confirm was that he would often leave them running for weeks on end even if he wasn't doing anything and his power bill was next to nothing because of the setup. From what I was told the power company came out to check things as his bills were often abnormally low and they thought he was stealing power before the meter somehow. They pulled the meter and it all shut off however. The theory was that because he had a residential meter it wasn't able to handle what he was doing with it and there was some sort of odd ripple feedback or something of that nature which prevented the meter from properly reading the power use because of the 3 phase setup where the 3rd leg was connected between multiple motors. Again I can not confirm this but I don't have any reason to think he was lying about it. I am also doubting that modern meters would have the same issues but the power company opted not to change it because they would have had a major cost to them with little gained return.

    • @billrobert3226
      @billrobert3226 Před 10 měsíci

      I've heard many happy stories of bad meters giving the customer a discount!

    • @MuttMuttOutdoors
      @MuttMuttOutdoors Před 10 měsíci

      @@billrobert3226 Yeah, the old school mechanical ones can be messed up using a big magnet from an old speaker. I am sure the new ones have other things that will cause issue with them as well since they can either use shunts or CT clamps. I personally use CT clamps on my lines for my own personal meter.

    • @stangatus7550
      @stangatus7550 Před 2 měsíci

      Without a capacitor, this is what you should do. Using a pulley...

  • @congerthomas1812
    @congerthomas1812 Před 11 měsíci +2

    Thanks,have heard of it but never seen one.

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm Před 6 měsíci +2

    I subscribed your channel sir

  • @kalyananaramansantanam6006
    @kalyananaramansantanam6006 Před 11 měsíci +2

    fantastic, the presentation is really super.

  • @fiazshah8289
    @fiazshah8289 Před měsícem +1

    so lovely

  • @MIKSTV-gb6rx
    @MIKSTV-gb6rx Před 2 měsíci +1

    thank you and God bless you

  • @hughleyton693
    @hughleyton693 Před 11 měsíci +1

    Yes, correct, you can drive a 3-phase motor using a Capacitor like that. . . . BUT the value of the Capacitor will only be correct for one size of motor and also for only one specific speed or Power output on that motor.. . . These days, it would be better to get a VFD drive unit, which can change single-phase to 3-phase.

  • @GroovyG0
    @GroovyG0 Před rokem +4

    From 3'54" rubbish - the overload relay does not detect zero current through T3 or anywhere else. The relay is designed to trip when all 3 lines are overloaded. When marginal overcurrent flows only through 2 lines, the thermal conditions for tripping are not satisfied and the relay will not trip. This is why, when using a 3 pole overload relay on a single phase motor, the load current must be taken through all 3 poles as illustrated.

    • @TheMannuz
      @TheMannuz Před 11 měsíci +1

      Most overload relays will trip after a while if the load is extremely unbalanced but not overloaded. It could run for several days without any issues but suddenly it will trip.

    • @donaldroot8035
      @donaldroot8035 Před 10 měsíci +1

      Some overload relays also include phase loss protection. That is why it is proper to wire it as shown in the video.

  • @lorenrasmussen338
    @lorenrasmussen338 Před 11 měsíci +3

    I just use a cheap small single phase motor with a coupler to a larger 3 phase motor as a converter…. Avoids huge current surges and voltage drops. Most power tools can tolerate slight power factor errors

  • @atseaeto4119
    @atseaeto4119 Před 2 lety +4

    Thank you!

  • @bonnylasu7665
    @bonnylasu7665 Před 10 měsíci +1

    Sir thank you very much. I'm very interested

  • @Voltechs-Tv
    @Voltechs-Tv Před 11 měsíci +1

    Nice bro... Continue good work.. ❤❤

  • @MervynPartin
    @MervynPartin Před 11 měsíci +4

    Some 3 phase motors use star/delta starters to achieve soft start and to reduce starting current.

  • @petertyrrell6690
    @petertyrrell6690 Před rokem +3

    Great video, thanks. You can start a 3 phase motor connected as you describe by momentarily connecting a heavy wattage resistance (I forget the resistance value) across where you have your capacitor. The motor will run, and is generates the third phase at its unconnected terminal. You now have a rotary converter, and you csn connect a normal 3 phase motor and its control circuit to your rotary converter.

    • @ElectroAcademyEA
      @ElectroAcademyEA  Před rokem

      Thank you

    • @firealarmapprentice4517
      @firealarmapprentice4517 Před 6 měsíci

      That would not be a good idea.What it sounds like is you are trying to current limit a field with resistance but I can certainly assure you it will not run safely

    • @petertyrrell6690
      @petertyrrell6690 Před 6 měsíci

      @@firealarmapprentice4517 The resistance is only in circuit for a fraction of a second. Anyway, I have actually used this method of starting a three phase motor, it works, although my motor was under no load. I built a rotary converter.

    • @firealarmapprentice4517
      @firealarmapprentice4517 Před 6 měsíci

      So if you get a 3phase motor to "spin" on single phase its Great BUT... The single phase is 180 degrees out of phase, but the windings are 120 degrees out of phase. It would be like driving a car where the passenger wheel is turning left and the driver wheel is turning slight right.@@petertyrrell6690

  • @assassinlexx1993
    @assassinlexx1993 Před 11 měsíci +2

    Vfd is the way to go. You can make a small air compressor produce high volume of air. For air tools.

  • @jensschroder8214
    @jensschroder8214 Před 11 měsíci +2

    also works with split phase 120 volts AC = 240 volts between the two phases instead of the neutral wire.

  • @mikechiodetti4482
    @mikechiodetti4482 Před 11 měsíci +1

    Wow! I'd like to see that.

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm Před 6 měsíci +1

    And also shared your channel

  • @sheriffdeen175
    @sheriffdeen175 Před rokem +2

    Thankfully sir

  • @MBaihaki
    @MBaihaki Před 10 měsíci +2

    Yes, this will run as a splt phase motor, but only at a very reduced output.

  • @ariedekker7350
    @ariedekker7350 Před 11 měsíci +2

    What I miss are the control of the voltages on the motor terminals.
    These should be nearly equal across the three points with a running motor.

  • @NyambeKennedy-pq3dd
    @NyambeKennedy-pq3dd Před 8 měsíci +1

  • @christianwuethrich2222
    @christianwuethrich2222 Před 11 měsíci +3

    The problem is that the phase shift between two phases of the 3phase is 120 ° but between the red and the black it is 180 °. So it may turn but it is far from optimal.

  • @hk4400
    @hk4400 Před 11 měsíci +1

    👍

  • @davey2k12
    @davey2k12 Před 11 měsíci +1

    That's same as my old air compressor setup 😂

  • @patil9919
    @patil9919 Před rokem +1

    👍✌️👌👌👌👌🤗

  • @edimichaelchannel1162
    @edimichaelchannel1162 Před 10 měsíci +1

    this is in my exam on my 5th year in Electrical engineering!😂

  • @tamilamuthanthangavel5568

    Excellent sir
    5hp motor
    full load current 9 Amps
    Please tell me capacitor rating

    • @ElectroAcademyEA
      @ElectroAcademyEA  Před rokem

      This is 3.8 kW motor.
      For 230 V AC supply, use 275 Microfarad 440 Volt capacitor.
      Please do this only for testing purposes.
      Continuous running is not recommended.
      Thank you.

  • @jeremyallard7015
    @jeremyallard7015 Před 11 měsíci +1

    Gone seem to be the days of swapping two live connections in order to get the motor rotating correctly. Is the single phase operation covered in the IEEE Regs?

  • @miker252
    @miker252 Před 11 měsíci +1

    How does this affect the motor efficiency? Do you need to increase the fuse and overload amp ratings?

    • @ElectroAcademyEA
      @ElectroAcademyEA  Před 10 měsíci

      We recommed this method for testing purposes of a 3 phase motor and short period running of it.
      If you intend to run it continuously, best option is to go for a single phase to 3 phase converter.

  • @paulusgnome
    @paulusgnome Před 11 měsíci +1

    I have done this before, on a tyre-changing machine, but wouldn't recommend it unless there was no other option.
    If you can afford it, a small VSD running off the single-phase supply is a much nicer option.

    • @Jason-wc3fh
      @Jason-wc3fh Před 8 měsíci

      You mean VFD?

    • @markmonson573
      @markmonson573 Před 8 měsíci

      @@Jason-wc3fh A Variable Speed Drive aka a Variable Frequency Drive. Same beast by a slightly different name.

  • @firewoodsteel
    @firewoodsteel Před 2 měsíci

    Would it be better to use 2 phase or 1 line and neutral?

  • @reamer1363
    @reamer1363 Před 11 měsíci

    And watch the lights in the house diminish to nothing LMAO

  • @Ratridez
    @Ratridez Před 10 měsíci +1

    I bought a digital phase converter

  • @randallsnell5767
    @randallsnell5767 Před 11 měsíci +1

    It may turn, but try to use it.

  • @smithno41
    @smithno41 Před 11 měsíci +2

    Nowadays you get a VFD that has single phase input and three phase output.

    • @miker252
      @miker252 Před 11 měsíci

      Plus you have the advantage of a soft start.

  • @mithunsarker5090
    @mithunsarker5090 Před rokem

    In this method, does it possible to continuous run a motor? If possible, what is the maximum motor power???

  • @sonnypillarina6056
    @sonnypillarina6056 Před 8 měsíci

    What capasitor i use in 3 phase motor to single phase 220v?
    3 phase motor specs..
    Y DELTA 346-480/200-280V. 1.40/2.45 A
    COS♤ 0.80 0.55KW. 3400. 1/min. 60hz

  • @Ddiizhsjsabv
    @Ddiizhsjsabv Před 4 měsíci

    Is it starter capacitor or run capacitor?

    • @ruelaguirre8096
      @ruelaguirre8096 Před 3 měsíci

      I think it is run capacitor..

    • @hanson8092
      @hanson8092 Před 2 měsíci

      If for start capacitor, its only for single phase motor

  • @user-vh6qy5yu5h
    @user-vh6qy5yu5h Před 8 měsíci

    electric chair :-)

  • @cetocoquinto4704
    @cetocoquinto4704 Před rokem +32

    Just buy a single phase to 3 phase VFD

    • @wangaui
      @wangaui Před 11 měsíci

      Spot on

    • @jacquesdebruyn6748
      @jacquesdebruyn6748 Před 11 měsíci +3

      Pretty sure I'd be cheaper to just go buy a single phase motor then....

    • @wangaui
      @wangaui Před 11 měsíci +2

      @jacquesdebruyn6748 not always practical as single phase motors are larger a larger frame size than 3 phase for the same power output so if its going on a flange it will be to big to fit

    • @cetocoquinto4704
      @cetocoquinto4704 Před 11 měsíci +1

      @@wangaui correct..i recently did this on a 3 phase lathe we only have single phase source. If you put single phase motor it will surely not fit hahaha more expensive job.

    • @mick1gallagher
      @mick1gallagher Před 11 měsíci +1

      There's a good reason why you have single phase and three phase

  • @erickmotieri2748
    @erickmotieri2748 Před rokem +1

    25hp motor tell me the capacitor rating. Sir

    • @ElectroAcademyEA
      @ElectroAcademyEA  Před rokem +6

      25 hp means it is fairly a large motor with 18.5 kW power rating.
      For testing purposes, you can use 1300 microfarad, 400 V capacitor.
      Large motors like these, are not recomended for continuous running on load with this method.

  • @ivodepin3494
    @ivodepin3494 Před rokem +1

    Traduzione in italiano?

    • @ElectroAcademyEA
      @ElectroAcademyEA  Před 11 měsíci

      puoi usare i sottotitoli tradotti. selezionare le impostazioni, contrassegnate come una ruota dentata sullo schermo. quindi seleziona i sottotitoli. quindi seleziona la traduzione automatica. nell'elenco delle lingue selezionare italiano. ottieni i sottotitoli in italiano.

  • @erickmotieri2748
    @erickmotieri2748 Před rokem +2

    Add the start, stop button

  • @pauljanssen7594
    @pauljanssen7594 Před rokem +2

    This will not startup of 3-phase motor under load cheapest way of doing called a pony motor

  • @williamfowler616
    @williamfowler616 Před 11 měsíci

    All motors are three phase, the reason for capacitors.

  • @HughCStevenson1
    @HughCStevenson1 Před 11 měsíci

    This is apallingly misleading. I am an EE and have designed motor drives. What is the 3 ph voltage L-L? What is the single phase voltage L-N? How much power can you expect from the 3 ph motor? (not much!). How much starting torque, for a compressor, say (a common 3 ph application). Basically so simplistic as to be worthless and potentially dangerous. And why the speech synthesis? Struggled with microfarad!

  • @leftylou6070
    @leftylou6070 Před 10 měsíci +1

    I'm not even gonna watch this and tell you to use a phase converter to operate a 3ph motor with 1ph power.

  • @timh.2137
    @timh.2137 Před 10 měsíci +1

    Could you have possibly made this any more confusing?

  • @user-so3vf7rg8d
    @user-so3vf7rg8d Před 4 měsíci

    Connecting single phase to a 3 phase motor. That motor will loose 30% of its efficiency.

  • @bahn5ee
    @bahn5ee Před 11 měsíci +1

    Sorry but this concept is kind of nonsense, it wouldn't even turn over. Just use single phase motor, is more efficient. By the way you cannot start 3 phase motor without star delta switch unless you run it just with star connection with less power.

    • @Henning_S.
      @Henning_S. Před 11 měsíci +1

      @bahn5ee you can also start 3 phase motors in delta configuration but they draw a lot of current so you do it only with small motors.
      Here in Germany you have to use a star-delta switch for motors above 6kW to avoid a voltage drop in the local energy grid. So your neighbors don't notice their lights getting dim for a split second while you are starting the motor...

  • @khokonpiru4552
    @khokonpiru4552 Před 10 měsíci +1

    Fake

  • @ptv1250
    @ptv1250 Před 4 měsíci

    Can you help with diagram on how to connect 1 phase 240v motor with two capacitors and reverse?

  • @wasimedoo7994
    @wasimedoo7994 Před rokem

    What is the biggest size of motor can run single phase and you were saying 70 uf capacitor for 1kw so 3kw by 70 with be 210uf am I correct thanks please let me know

    • @Henning_S.
      @Henning_S. Před 11 měsíci

      Yes it will work for a 3kW Motor, but not for continuous operation, it will get pretty warm...
      It will also have a relatively low torque when starting and less power output overall.
      So it is no replacement for 3phase power, it will work for small motors with no load at startup and manually variable load at operation, but not for most motors with a fixed load...
      So for example you can use it to power a bench grinder, but probably not for an air compressor or pressure washer ...
      If you don't want to lose power, the better option is to buy a VFD if you just have 1-2 3phase motors. If you have multiple motors it may be cheaper to buy a rotary converter...
      Of course, if you live in Europe the cheapest option is to just install a 3phase outlet (CEE), basically every domestic household already has 3phase power...