GOODMAN AMANA FURNACE NOT HEATING 3 COMMON DIAGNOSTIC CODES: HOW TO FIX THE CAUSES

Sdílet
Vložit
  • čas přidán 9. 01. 2021
  • This video will show the 3 most common error codes for a Goodman/Amana furnace. I will show how the unit acts as a result of the code and explain common things to look for and repairing them.
    IF THIS VIDEO WAS HELPFUL CONSIDER THE THANK YOU BUTTON!!!
    Consider supporting my Channel at my paypal
    paypal.me/ihvacr?country.x=US...
    link for camera I use to make videos amzn.to/3W6bEKi
    link for camera gear I use to make videos amzn.to/3FJLiIo
    link for drone I use for video amzn.to/3uZyg3H
    Please consider subscribing to my channel. czcams.com/channels/v8O.html.
    To contact me email Renpavich72@gmail.com
    Purchase new flame sensors for Goodman/Amana Furnaces
    amzn.to/3hDsTPV
    Klein 6 and 1 stubby screw driver
    amzn.to/3pDT3F4
    Furnace Magnet
    amzn.to/3nqN5pC
  • Jak na to + styl

Komentáře • 81

  • @IHVAC
    @IHVAC  Před rokem

    PLEASE WATCH THIS FOR MORE INFORMATION czcams.com/video/_0sCWTy0MKQ/video.html

  • @gregt4202
    @gregt4202 Před 27 dny +1

    Useful video. Thanks!

  • @care_4445
    @care_4445 Před rokem +1

    Thank you for this video I was able to diagnose and fix my Amana heater. I used the paperclip hack!

  • @sharonspringsspartans12ufa4

    Thank you so much !!1 Pressure switch was stuck open (bought a new one had same issue no ignition i was perplexed) then I watched your video. The needle in the metal hose grabber cleaned the obstruction and we have heat !!!!! wish I watched this before my order to Amazon !!! Thank you again!!!

    • @IHVAC
      @IHVAC  Před 2 lety

      Glad it helped!

  • @timothyholland8824
    @timothyholland8824 Před rokem

    Thank you for a very clear and educational video. You explain and demonstrate things extremely well.

  • @josepenado6068
    @josepenado6068 Před 2 lety +3

    I wanna to take a moment to say thanks for this amazing video very helpful 👏

  • @union-ft6bt
    @union-ft6bt Před 2 lety +2

    Loved the video you helped me greatly I was racking my brain my furnace wouldn't fire gas valve not turning on no voltage to igniter code 4 checked limit switch seemed good watched your video and learned there was a secondary limit switch on my Amana on the side of the blower motor actually 2 of them one on each side of the blower motor fixed them and kicked right on THANK YOU SO MUCH GREAT VIDEO

  • @arturoperez9429
    @arturoperez9429 Před rokem +1

    I want to give thanks for the info on this video. I was able to get my heater up and running. Great video

  • @user-bd5bv9sf1g
    @user-bd5bv9sf1g Před 6 měsíci +1

    He explained very clearly

    • @IHVAC
      @IHVAC  Před 6 měsíci

      Glad it helped

  • @modelsupplies
    @modelsupplies Před rokem

    My heat is revving on auto wouldn't run. Put it on "on" and it's running! I guess I'll turn it on and off manually until I can figure it out. I miss my late husband who would've fixed this. Thank you so much for posting this video! Can't believe I needed it the night before Thanksgiving. I changed the batteries in the thermostat and the filter in the furnace, but neither worked. Thank you for saying that around 7:30 that turning it to on, it should run.
    Happy Thanksgiving!~
    It's been running ever since! Thank you so so much!

  • @raja29bajwa
    @raja29bajwa Před 2 lety +3

    Fantastic job explaining things.
    Thank you

    • @IHVAC
      @IHVAC  Před 2 lety

      Glad it was helpful!

  • @heatingairservices8708
    @heatingairservices8708 Před 2 lety +1

    1 st time watcher of uR Chanel so Pleased I did subscribe to your Channel ....Great Video for Inclined Home owners beginner HVAC techs or for even for an 27 yr seasoned Vet like myself ..I learned a few things to help simply testing Goodman error codes ..thank you very much .Note ..To Other subscribers out there ... this man Knows His Craft

  • @pamlloyd141
    @pamlloyd141 Před 2 lety +1

    Thank you for the great video. I changed the furnace igniter. Works great.Thanks

    • @IHVAC
      @IHVAC  Před 2 lety

      Glad it helped

  • @MoMo-fh3oz
    @MoMo-fh3oz Před 2 lety

    Excellent ..he is professional..

  • @daisymangat5190
    @daisymangat5190 Před 2 lety

    Thank you. I liked your thinking to help people.

  • @jeffcibulka5063
    @jeffcibulka5063 Před 6 měsíci +1

    Thank you Brother. Great help

    • @IHVAC
      @IHVAC  Před 6 měsíci

      Glad it helped

  • @stanacho854
    @stanacho854 Před 2 lety +1

    Thanks so much for the great video, it's been very helpful in my diagnostics

  • @ranchofyrman
    @ranchofyrman Před rokem

    Very good video!! Thank you. You saved me some serious cash.

  • @zackhersrud5682
    @zackhersrud5682 Před rokem

    Youre an absolute legend

  • @misodinamosa
    @misodinamosa Před rokem

    Thank you!

  • @luvtofixpipes
    @luvtofixpipes Před rokem

    Very good video

  • @dwalkervocalman1
    @dwalkervocalman1 Před 3 lety +1

    Fhank you for your advice! My Goodman furnace was in lockout mode due to too many start attempts. All is well now!

    • @IHVAC
      @IHVAC  Před 3 lety +1

      I'm glad it helped thank you for the feed back.

    • @IHVAC
      @IHVAC  Před 3 lety

      Thank you for the feed back glad it helped.

  • @mxg709
    @mxg709 Před 2 lety

    Great video

  • @wascash
    @wascash Před 2 lety +1

    My sister has the same Goodman furnace upright version and it would not work I replace the thermostat and still couldn’t get it to work only until you told me about the blinking light codes I was able to fix it had an open fuse circuit little number three purple fuse was blown replaced it and it fired right up thank you so much

    • @wascash
      @wascash Před 2 lety

      Can’t edit on my phone but by the way it was 5° tonight in Kansas City and her pipes were froze so this really did help

    • @IHVAC
      @IHVAC  Před 2 lety

      I'm glad you found the video and I am glad you seen what you were looking for.

  • @COZWV
    @COZWV Před 3 lety +4

    Thanks! Got my furnace fixed after coming home to a cold house after vacation at 1:00 AM! Due to your video I was able to check the pressure switches and one had a couple of drops of water in it that was blocking it from working. Was on vacation and the heat wasn't on and the temps dropped a lot! Wondering if that caused the water to build up?

    • @IHVAC
      @IHVAC  Před 3 lety +1

      I'm very glad the video help.

  • @12345tlynne
    @12345tlynne Před 3 lety

    This video is great! I really learned a lot, and it was helpful to see the error codes and causes.

    • @IHVAC
      @IHVAC  Před 3 lety

      Glad it helped!

    • @IHVAC
      @IHVAC  Před 3 lety

      Please give the video a like and subscribe. Want more videos have a question lmk. Ty

  • @jonathanwright6050
    @jonathanwright6050 Před 2 lety +1

    I have a 4 blinking light indicator for open high limit. Should I order two replacement switch to start ? Any help would be greatly appreciated

  • @hugoconrad1063
    @hugoconrad1063 Před 2 lety

    Hi thanks for the video. Hope you can point me out on my problem. I switched from heating to A/C and my SSZ14 is not starting. The error code on my goodman furnace AVPTC is C1 - LOW STAGE COOL - LEGACY MODE ONLY. Do you have any idea how to resolve this issue. The unit was working great during winter but now switching to A/C and the heat pump is not starting anymore. Thanks Hugo

  • @user-yo7so1md5l
    @user-yo7so1md5l Před 8 měsíci +1

    I can check the pressure switch still not getting anything

  • @lillithjones993
    @lillithjones993 Před rokem

    My new Amana furnace red light is blinking at least 9 times. I know it’s a furnace, but does it have anything to do with the AC not blowing cool? The gas is not hooked up yet.

  • @Veldavis
    @Veldavis Před 7 měsíci

    I have the same the same GoodMan heater furnace my problem is it works but, I just see that the light when I look at it it was red instead of green, how can I solve this problem? Thanks

  • @Ecuaspic
    @Ecuaspic Před 2 lety +1

    Awesome video, my issue is the flames come on intermittently and cycles on and off while heating the house. Flame sensor switch and it was in quicker intervals. Think it may be faulty high limit? But it looks pretty clean to me. After watching this video think my issue may be pressure swith?

    • @IHVAC
      @IHVAC  Před 2 lety +1

      Poor air floor causes limits to get week must measure return air temp and supply air temp. See if that tells you something.

    • @Ecuaspic
      @Ecuaspic Před 2 lety

      @@IHVAC i got it!! It was definitely the pressure switch but not the switch itself it was the lil hose, it was super loose. Gonna need to replace it had to secure it with electrical tape for now😅

  • @samirhavic
    @samirhavic Před 3 lety +1

    I have the same furnace. Mine has 4 flames tho. I have an issue where the heat comes on and sometimes it doesn’t swapped 3 thermostats. Currently using a plain one no WiFi. What would cause intermittent heat and i had one flash and cleaned the flame sensor. But hasn’t helped much thank you and appreciate any help

    • @IHVAC
      @IHVAC  Před 3 lety

      First thing I would check is airflow. Clean filters and make.sure registers are all open. Then I would clean the flame flame sensor. If your able to take a video of it not.coming on and let me see what the furnace is doing or not doing. My email is in the description.

  • @pbc1951
    @pbc1951 Před 2 lety +1

    I have a Question, or problem with my Goodman Gas Heat furnace.... once every 3 or 4 weeks it won't come on. but works just fine 20 times or more per day for weeks.... Here is where it gets to.... draft fan comes on, pressure switch says OK, Red Glow on the igniter is fine... gas valve will not let it have gas.... Gas valve is fine for the 200 cycles it just went thru in the last 3 weeks, & I even Replace gas valve with a new one a few months ago.... So what step is between glow plug on and gas valve not opening.... that could be sporadic. that I should look at. Great Video and Thank you for your time.

  • @frankjames1955
    @frankjames1955 Před 3 lety +1

    according to the after hours tech the power is going into the connections on the gas valve but not going out ( to inducer and limit safety circut ) .. so i need a new gas valve ... he wanted $790 for a $300 gas valve

  • @aleksjimenez1
    @aleksjimenez1 Před 3 lety

    Hi my name is Alex I just saw your video and what my furnance does is that the blowers goes on and the ignitiator goes on and aftet 10 seconds goes off and that set. the LED signal just stay on and the flame never turn on. what can I do. please need help.!!

    • @IHVAC
      @IHVAC  Před 3 lety

      Pressure switch is open? What type of furnace?

  • @manuelsalgado8510
    @manuelsalgado8510 Před rokem +1

    So I broke the tip of the ignitor , having issues finding the new part. Any ideas on how to repair the tip?

    • @IHVAC
      @IHVAC  Před rokem

      Buy a universal igniter

  • @deanhernandez690
    @deanhernandez690 Před rokem

    Ok I'm kinda stuck. My furnace turns on , gas turns on, fan turns on, emergency heat works but when I switch to auto it starts blowing cold air. Any ideas ?

  • @Davidblaine18
    @Davidblaine18 Před 9 měsíci +1

    I have no flame

  • @stanmondzelewski9253
    @stanmondzelewski9253 Před 2 lety +1

    I got a amana air command 95.
    I got 4 flashes. Open limit.
    Blower is staying on i know its suppose to stay on with a open limit.
    I got continuity through both limits and continuity through the wires from limit to the plug on the board.
    I also jumped the limt just to make sure it wasnt the problem.
    Filters clean,vents are all open.
    Its not overheated, its been sitting all day with the power.
    Bad board?

    • @IHVAC
      @IHVAC  Před 2 lety

      Maybe a manual reset high limit by the blower housing?

    • @stanmondzelewski9253
      @stanmondzelewski9253 Před 2 lety

      @@IHVAC no
      Just the limt and a roll out switch above the burnners

    • @stanmondzelewski9253
      @stanmondzelewski9253 Před 2 lety

      @@IHVAC i replaced the board.
      Got heat again

  • @heatncool
    @heatncool Před 3 lety

    You can break that pressure switch doing that 😀

  • @xXxCrazyJay810xXx
    @xXxCrazyJay810xXx Před rokem

    What if the blower motor starts first

  • @lawrencecrum7091
    @lawrencecrum7091 Před rokem

    My code light is not blinking it's just solid and my nighter is not catching it's like it's not getting any gas

  • @kiturselassie813
    @kiturselassie813 Před rokem

    4 blinking lights code ,what is that

  • @crounsefrank
    @crounsefrank Před 2 lety +1

    I have a Goodman GKS90, LED steady light, igniter glows red but no flames, nothing blowing out the house heater vents. Anyone have an idea? Tnx

    • @IHVAC
      @IHVAC  Před 2 lety

      Gas valve off or closed or low pressure switch maybe not closing

  • @sand.590
    @sand.590 Před 3 lety

    The flame is not turning on at all just making noise off the furnace m. Help please thank you

    • @IHVAC
      @IHVAC  Před 3 lety

      Renpavich72@gmail.com email me your number and I'll help you

  • @intelin123
    @intelin123 Před 2 lety +1

    I got an amana furnace that inducer turns on and quickly dies and i get 8 flashes. Ignitor reads zero ohms.

    • @IHVAC
      @IHVAC  Před 2 lety

      Replace ignitor.

    • @intelin123
      @intelin123 Před 2 lety

      Thank you. I got a new ignitor and it now ignites but theres no flame.i get 24v to gas valve and gas valve is not opening. I gotta get a new gas valve now. I never knew amana checked ignitor after inducer

  • @lindamora7
    @lindamora7 Před 2 lety +1

    I have 3 3 second blinks what is that?

    • @IHVAC
      @IHVAC  Před 2 lety

      Open the panel.it should tell you what that means

  • @josiejohnson8926
    @josiejohnson8926 Před rokem

    I'm begging someone for help here!!! We purchased a Goodman furnace in September of this year, we've gotten them before. Our furnace will not run continuously, it ran for 8 days max. We have followed all the instructions had HVAC guys come here to install parts, as we were directed to do. We have everything documented, recorded as we spoke to the distributor which would be an HVAC direct. They Told my husband he was a "do it him selfer" and we just wanted free parts". No we don't, we want heat, I was told at one point not to lecture this one rep as we were talking. Yes I'm frustrated but I was rude, we even asked if they would send a representative out here to help us, told them if we messed up we would pay. They told us NO! This was HVAC direct, we are not looking for hand outs. We are looking for someone to help us please!! We live near Lake Ontario it's gonna get cold here, my husband has followed everything by the book. My next step is the news, but I don't want to do that. So please, please, will some one reach out to us whom has experience in this and with these furnaces to help fix this!!

    • @IHVAC
      @IHVAC  Před rokem

      EMAIL YOUR NUMBER LETS SEE IF WE CAN FIX IT? RENPAVICH72@GMAIL.COM

  • @user-yo7so1md5l
    @user-yo7so1md5l Před 8 měsíci

    I can check the pressure switch still not getting anything