Data Center HVAC - Cooling systems cfd

Sdílet
Vložit
  • čas přidán 15. 04. 2018
  • Data Center HVAC cooling systems. In this video, we look at data center HVAC designs with a focus on the cooling systems and air management strategies used, as well as design analysis with Computational Fluid Dynamics (CFD) on SimScale (www.simscale.com/). We cover raised floor, hot and cold aisle, hot aisle containment, cold aisle containment, CFD simulations, CRAC units, heat exchangers, chillers, free cooling, water and air cooled chillers as well as cooling towers.
    🏆🏆🏆 Create a free SimScale account to test the cloud-based simulation platform here: www.simscale.com/
    LEARN MORE HERE: theengineeringmindset.com/dat...
    Sign up for our FREE engineers newsletter for updates, competitions, news and offers
    🎁 Link: engmind.info/Engineers-Report
    With 100,000 users worldwide, SimScale is a revolutionary cloud-based CAE platform that gives instant access to CFD and FEA simulation technology for quick and easy virtual testing, comparison and optimization of designs in several industries, including HVAC, AEC, and electronics.
    Discover more than 50 free on-demand webinars on different topics, from ventilation or data center design and wind load analysis to aerospace, F1, and sports aerodynamics here: www.simscale.com/webinars-wor...
    Read more about the benefits of using cloud-based engineering simulation and the SimScale Community here: www.simscale.com/product/pricing
    Find thousands of ready-to-use simulation templates created by SimScale's users which you can copy and modify for your own analysis: www.simscale.com/projects/
    Read this article on "How to Design Data Center Cooling Systems and Ensure Compliance with ASHRAE 90.4: www.simscale.com/blog/2018/02...
    ⚡🛠️ TOOLS YOU NEED 🛠️⚡
    **************************************
    Get this HVACR book ➡️ amzn.to/3XFCaKC
    Professional Multimeter -➡️ amzn.to/3xu2Vaw
    Good multimeter -➡️ amzn.to/3xrbuTd
    Professional clamp meter ➡️ amzn.to/4140FnK
    Good Clamp meter ➡️ amzn.to/3xqt2is
    Outlet tester ➡️- amzn.to/3kavg2l
    Energy monitoring plug ➡️ amzn.to/3SkfPl7
    Battery tester -➡️ amzn.to/3S3fHWI
    Basic electronics kit ➡️ amzn.to/3xuLiqS
    MY FAVOURITE GEAR
    🎥 My camera - amzn.to/3YCZ7Q9
    🎤 My Microphone - amzn.to/3YYXsUC
    ⌨️ My Keyboard - amzn.to/3lBsl33
    🖥️ My monitor - amzn.to/415BGjW
    🎧 My headphones - amzn.to/3lN7R7u
    😎 Get your Engineers T-shirts, Hoodies, Cups & stickers here:
    *******************************
    goo.gl/M1PGrx
    ☕ Buy Paul a coffee to say thanks
    *******************************
    ⚠️ Found this video super useful? Buy Paul a coffee to say thanks: ☕
    PayPal: www.paypal.me/TheEngineerinMi...
    🙏 Support us on Patreon
    *******************************
    / theengineeringmindset
    🕵️ Check out our website!
    *******************************
    TheEngineeringMindset.com
    👥 Socialise with us
    *******************************
    FACEBOOK: / theengineeringmindset
    TWITTER: / theengmindset
    Instagram: / engineeringmindset
    Google+: www.google.com/+Theengineering...
    CZcams: / theengineeringmindset
    👀 Links - MUST WATCH!! 👀
    *******************************
    ⚡⚡⚡ELECTRICAL ENGINEERING⚡⚡⚡
    👉How electricity works: • How ELECTRICITY works ...
    👉Three Phase Electricity: • How Three Phase Electr...
    👉How Inverters work: • How Inverters Work - W...
    👉How TRANSFORMER works: • How does a Transformer...
    👉How 3 Phase electricity works: • How Three Phase Electr...
    👉How Induction motor works: • How does an Induction ...
    How water cooled chiller works Prt1 - • Chiller Basics - How t...
    How water cooled chiller works Prt2 - • Chiller Basics - How t...
    How Air cooled chiller works - • Absorption Chiller, Ho...
    How Absorption Chiller works - • Air Cooled Chiller - ...
    How Heat Pump works: • How A Heat Pump Works ...
    Primary & Secondary system: • HVAC Primary & seconda...
    Fan Coil Units: • Fan Coil Unit - FCU HVAC
    VAV Systems: • Variable Air Volume - ...
    CAV Systems: • Constant Air Volume - ...
    VRF Units: • Video
    HVAC Basics: • Fundamentals of HVAC -...
    Heat Exchangers: • Plate Heat Exchanger, ...
    Pumps: • Centrifugal Pump How D...
    How a Chiller, Cooling Tower and Air Handling Unit work together - • How a Chiller, Cooling...
    #HVAC #refrigeration #engineering

Komentáře • 85

  • @EngineeringMindset
    @EngineeringMindset  Před 6 lety +19

    ⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕
    PayPal: www.paypal.me/TheEngineerinMindset

  • @ericknebel5905
    @ericknebel5905 Před 6 lety +30

    Loved it. I'm part of the DDC division of an HVAC company, and I want to thank you for all the informative videos that keep me learning, but also helped me get the job. Currently I am working on a 1,000,000 sq ft data center project that is truly a feat of engineering. Love my job. Thanks, again.
    Eric

    • @javalearner4227
      @javalearner4227 Před 3 lety

      Hi Eric, I am looking for job in data center as ME engineer. Could you please guide me which skills should I focus on ? Currently, I am learning REVIT and have done analysis in CFD.

    • @maheshmurali2697
      @maheshmurali2697 Před 3 lety +1

      @@javalearner4227 Hi I'm a Dceo operations engineer and did Mechanical engineering. You need to have good knowledge in HVAC, Fire fighting and electrical systems.

  • @JeffFaume-en1xp
    @JeffFaume-en1xp Před 6 dny

    very excellent video, I learn new things by watching

  • @kasimshaikh3750
    @kasimshaikh3750 Před 3 lety +1

    I work at JLL in facilities management your videos are really helpful.

  • @smily2208
    @smily2208 Před 5 lety +12

    I do this everyday this video is spot on great job you deserve my thumbs up

  • @rock3tcatU233
    @rock3tcatU233 Před 5 lety +2

    I've never subscribed to a channel so quickly, finally I've found some quality MechE content on YT.
    Could you also do a series on semiconductor cleanroom engineering?

  • @intjonmiller
    @intjonmiller Před 6 lety +5

    In 2004 I worked in a sign shop that had been built to be a data center but which never took occupancy when the Dotcom bubble burst. The only climate control they had installed was a massive AC unit like these CRAC units, but which didn't have a controller. It was either on or off. In 20-30 minutes it dropped the temperature from about 85°F to 50-55°F. And while it was running it was deafening. But we only had to run it twice a day during the hottest part of the year.

  • @jonathanhernandez348
    @jonathanhernandez348 Před 6 lety +5

    Awesome video and very well put together. I currently work in constructing data centers and this video is perfect for anyone who wants to learn how this building gets cooled. I hope to see more videos coming from you explaining the electrical side such as how the power gets distributed from transformers to generators to Ups,PDU’s etc.

  • @andyhill242
    @andyhill242 Před 3 lety

    This video is particularly applicable to me.
    Modern HPC clusters often have power consumption in the MW range and often uses liquid cooling for CPUs GPUs and RAM, these usually consist of a local liquid loop with a heat exchanger linked to a secondary loop fed from the building chilled water system.

  • @kimberlysulit220
    @kimberlysulit220 Před 4 lety +1

    This is helpful for my architectural thesis, thanks.

  • @WarHammer1989
    @WarHammer1989 Před 5 lety +12

    I work on this stuff near daily, but I just started a month ago. This is very helpful!

    • @dylanrodriguez7129
      @dylanrodriguez7129 Před 3 lety +1

      What type of back ground do you need to pass ? Squeaky clean or your allowed a misdemeanor like a DUi

    • @bobbyBoosh
      @bobbyBoosh Před 2 měsíci

      I just had a company reach out about a job opportunity for Data center hvac. Worth it??

  • @innocentnwachukwu918
    @innocentnwachukwu918 Před 2 lety +1

    This is an awesome video. Thank you so much for putting this together. It is very helpful.

  • @JasonRichardsone
    @JasonRichardsone Před rokem

    One work exceptional - thank you

  • @apokalypz08
    @apokalypz08 Před 3 lety +2

    Side note, if the CRAC unit is using chilled water then it's typically called a CRAH (computer room air handling) unit. This is due to not having the compressor or majority of the work to cool being actually IN the unit like it is with a CRAC unit. With CRAH's the compressor doing the most work is typically in the upstream chiller or heat rejection equipment of similar type and function.

  • @ryanellinger103
    @ryanellinger103 Před 4 lety

    This is a cool video, but I work for a big commercial refrigeration and HVAC company in Arizona. I have never seen this. We do all the work for Century link in Arizona. They only use chillers or rtus. I’m not saying this doesn’t happen, but I think with all the bad airflow just use a chiller with multiple air handlers. Thanks for the video.

  • @talonwilliams6148
    @talonwilliams6148 Před rokem

    Your content is so touching

  • @hayel2015
    @hayel2015 Před 6 lety +1

    Great work done well

  • @IngDzib
    @IngDzib Před 2 lety

    Thank you Paul!

  • @PapaWheelie1
    @PapaWheelie1 Před 6 lety +5

    Probably the coolest video on data center environmental design

    • @EngineeringMindset
      @EngineeringMindset  Před 6 lety +2

      well played pun

    • @PapaWheelie1
      @PapaWheelie1 Před 6 lety

      The Engineering Mindset - I work in a small tech center and we don’t use under the floor forced air cooling because it requires plenum rated wire that is much higher $$

    • @PapaWheelie1
      @PapaWheelie1 Před 6 lety

      So we have to have the supply and returns in the drop ceiling- cold supplies in front of the racks and returns behind. Not nearly as efficient as supply below the floors. And some of the equipment pulls from the rear.

    • @EngineeringMindset
      @EngineeringMindset  Před 6 lety +1

      Sounds like some CFD sims could help you prove the business case to invest in improved cooling!

  • @richardwager283
    @richardwager283 Před 3 lety +2

    Would be good to see a video on static transfer switches 👍🏻

  • @hoshwagan4199
    @hoshwagan4199 Před 4 lety

    I found it realy helpful.

  • @thinkandquestion1305
    @thinkandquestion1305 Před rokem

    Great information. Thank you

  • @jakovbilic4556
    @jakovbilic4556 Před 2 lety

    Wow, great work!!

  • @haisridhar10
    @haisridhar10 Před 6 lety +1

    good explanation..

  • @samuelfrondozojr.1273
    @samuelfrondozojr.1273 Před 3 lety

    You have good application of Air conditioning systemapplied to all type of Area of location in a residential or commercial building.

  • @DuffsterZ
    @DuffsterZ Před rokem

    Nicely explained-

  • @kyoukohaha
    @kyoukohaha Před 7 měsíci

    Awesome!

  • @ahmadsurkanicks8345
    @ahmadsurkanicks8345 Před 4 lety

    I just knew the hot isle containment.. 👍👍

  • @OthmanAlikhan
    @OthmanAlikhan Před 2 lety

    Thanks for the video =)

  • @ajithkumarsarathy8732
    @ajithkumarsarathy8732 Před 4 lety +1

    Can you explain about relative humidity. Why it is important in precision AC and data center

  • @STDrepository
    @STDrepository Před 6 lety +22

    PLEASE TALK ABOUT HVAC SYSTEMS ON NAVY SHIPS

    • @bidav2114
      @bidav2114 Před rokem

      If he knows about that he will do it.

  • @mahdi.shahsavari
    @mahdi.shahsavari Před 5 lety +3

    Thank you sir.
    1. Are data center can work on partial load like residential unit? Are there any load variations on a server room?
    2. In free cooling method without plate heat exchanger, is there any limitation for moisture for electronic devices?

  • @asifhussain3032
    @asifhussain3032 Před 2 lety

    Sir, you are explaining in much easier way but can you please explain what is basic of data center after that this critical one

  • @snkrmindset93
    @snkrmindset93 Před 4 lety

    I'd like to know how fire suppression nozzle will be placed if there will be a ductwork for hot aisle containtment system?

  • @markarca6360
    @markarca6360 Před 3 lety

    This is also called CRAC (Computer Room Airconditioning) units.

  • @sorosekaewmanee1845
    @sorosekaewmanee1845 Před 3 lety

    Very good video

  • @fayzankhan1781
    @fayzankhan1781 Před 6 lety +1

    What standard is used for hydrotesting of chilled water pipes?

  • @nileshgaikwad6707
    @nileshgaikwad6707 Před 4 lety

    Please make video on immersion cooling data center technology.

  • @philipmungai9070
    @philipmungai9070 Před 3 lety

    Nice video

  • @akshaykorlekar
    @akshaykorlekar Před 2 lety +1

    Thanks

  • @octaviovinoly
    @octaviovinoly Před 7 dny

    Do you know what are the average outlet water temperatures from the chillers for these applications? Would water need go below 0°C?

  • @RD-lf3pt
    @RD-lf3pt Před 4 lety +2

    May you share the Simscale design? :D

  • @vijayme123able
    @vijayme123able Před 4 lety

    Good explanation Paul,
    Can you make more videos on Data center or can suggest CZcams channel which offers good learning for HVAC design in Data center w.r.t uptime or TIA tier certification

    • @EngineeringMindset
      @EngineeringMindset  Před 4 lety

      Thank you. I've been planing to do a video on CRAC units for a while, maybe evaporative coolers too. I think next month we'll publish a video about some colling components inside a CRAC unit so we can tie that in to data centres

  • @ecantil2267
    @ecantil2267 Před 3 lety

    With regards to the DC Energy Consumption ratio: I think its best to allocate 50% of power on HVAC and 36% on IT Equipment (10% on Network Devices and 26% on Server and Storage).

    • @mariacisni3212
      @mariacisni3212 Před 2 lety

      I think if that's the case, the PUE will decrease

  • @zuberkhan8560
    @zuberkhan8560 Před 2 lety

    Can you please help us to understand the effect of unfiltered or generated gases due to heat..what are the effects and how can we tackle the issue..

  • @brentwilliams191
    @brentwilliams191 Před 3 lety +2

    I find it funny that HVAC is for Aircons, where its been a very long Time the means of "High Voltage Alternating Current".

  • @user-le3tz7mf4k
    @user-le3tz7mf4k Před 3 lety

    👍👍👍

  • @so8up839
    @so8up839 Před 3 lety

    what the best hvac system design for data center

  • @connorwatson7162
    @connorwatson7162 Před 4 lety

    What are the sources for this video so I can do more research?

  • @TGmirul
    @TGmirul Před 3 lety

    Hey, im currently working on my assignment data center. Does anyone know how to select diffuser for floor raised.

  • @Matt-rx4pm
    @Matt-rx4pm Před rokem

    Great video! I don't know if I am the first to nerd out on this video and pick it apart like a troll, but you incorrectly call a computer room cooling unit (@10m:44s) connected to chilled water system a CRAC but its actual a CRAU (Computer Room Air Handling Unit). There is no AC (Air Conditioning) when using a chiller so I get it and using the term "Crack" is a generalization. If I am building a project and we have chilled or condenser water in the computer room I start to worry about a new set of issues, computer and water don't mix.

  • @ask4george1
    @ask4george1 Před 4 lety

    Data centers are always expanding, they often don't take into consideration the added heat load. They just keep pushing in more racks. One solution was a manifold piping system over head, with quick connects. You just place fan unit cooler on top of the new data rack and hook up the quick connect flexible refrigeration lines that's it. The main cooling unit has a large reservoir to accommodate multiple fan units. It was years ago when I helped install the manifold piping system, and I can't remember what it was called. Maybe someone knows the system name.

  • @AKK105
    @AKK105 Před rokem

    why there are gas pipes for the outdoor unit of a water-cooled in-row unit?

  • @SH-ex6wj
    @SH-ex6wj Před 4 lety

    Can you provide me ppt presentation for like this without voice for 2 different topics?

  • @AjayKumar-ct6ok
    @AjayKumar-ct6ok Před 2 lety

    Dear sir please. Make a video all in hindi ....

  • @mustafaahmed5187
    @mustafaahmed5187 Před 4 lety

    can i get HAP file for these room ?

  • @canudigitsucka007
    @canudigitsucka007 Před 5 lety

    Hey Paul, the VRF video is missing. Can you upload this one again?

    • @EngineeringMindset
      @EngineeringMindset  Před 2 lety

      New VRF unit video here:➡️ czcams.com/video/4i1XgcP1tmw/video.html

  • @exterminator4808
    @exterminator4808 Před 3 lety

    What you described as a 'CRAC' unit is actually a 'CRAH' unit.

    • @smokeysmith1282
      @smokeysmith1282 Před 2 lety

      Depends however on the location of the mechanical cooling equipment. CRAC units include the mechanical cooling system at each unit. CRAHUs are chill water fan systems and rely on remote Chillers type systems.

  • @S-khalil
    @S-khalil Před 4 lety

    The picture at 0:17 is not a recommended way for stacking racks, it should be like Cold-Cold front or hot-hot front.

  • @STEINYY
    @STEINYY Před 3 lety

    Why cant I see the VRF video? It's not available does it say..

    • @EngineeringMindset
      @EngineeringMindset  Před 3 lety

      Was deleted. Check our supermarket hvac video for vrf basics

    • @STEINYY
      @STEINYY Před 3 lety

      @@EngineeringMindset aright will do so, thx!

    • @EngineeringMindset
      @EngineeringMindset  Před 2 lety

      New VRF unit video here:➡️ czcams.com/video/4i1XgcP1tmw/video.html

  • @imacgra1
    @imacgra1 Před 8 měsíci

    And you forgot the platform that everyone who watch this video definitely uses CZcams 0:37

  • @EngineeringMindset
    @EngineeringMindset  Před 5 lety

    ⚠️ Learn how *AIR HANDLING UNITS* work here: czcams.com/video/KCiv8IAUkh8/video.html ⚠️

  • @asemahmed2618
    @asemahmed2618 Před 2 lety

    I hope you put an Arabic language as translation

  • @---wl3bi
    @---wl3bi Před 4 lety

    versatemp in a data centre, not very efficient

  • @cmj13
    @cmj13 Před 2 lety

    You are too fast in explanation, otherwise it is good !

  • @gg-gn3re
    @gg-gn3re Před 3 lety

    All of these are junk. I run several crappy black pipes 7ft under ground for 200ft and pump in 48F air into my greenhouse and room year around. Can't get more efficient than 1 fan.