Video není dostupné.
Omlouváme se.

Wiring 2 Hikvision Face Recognition Terminals into a Single Door using Maglock

Sdílet
Vložit
  • čas přidán 8. 11. 2023
  • In this video, Oliver shows you how to wire 2 Hikvision Face Recognition Terminals into a single door using a Maglock.
    In addition, you will see how to wire these in a secure method with the relay being triggered from the "secure side" as well as utilising a 'No Touch' Exit Button and Emergency Door Release, all going back to Haydon PSU's with battery backup.
    Products used/seen in this video:
    Hikvision Face Recognition Terminal - w.cop-eu.com/a...
    Hikvision Secure Module (If using a single Face Terminal) - w.cop-eu.com/a...
    Hikvision 'No Touch' Exit Button - w.cop-eu.com/a...
    STP Resettable Double Pole Emergency Door Release - w.cop-eu.com/a...
    STP Slim Monitored Maglock With Door Status Monitoring - w.cop-eu.com/a...
    Haydon 12V 3A PSU - w.cop-eu.com/p...
    Yuasa 12V, 7.0Ah Battery - w.cop-eu.com/p...
    Wiska Gel Filled Box with Wago - w.cop-eu.com/p...
    ‪@HikvisionUKIreland‬
    ‪@HikvisionCorporateChannel‬
    ‪@WISKAChannel‬
    #hikvision #accesscontrol #howto #facerecognition #maglock #stp #haydon #wiska #wago #yuasa
    Hikvision Face Terminal Quick Start Guide can be found at, www.hikvision....

Komentáře • 3

  • @brendandigney8520
    @brendandigney8520 Před 3 měsíci +1

    Followed step by step, and wiring continuity confirmed, but I can't get the slave unit to unlock the door via the master. Any ideas?

    • @Balarock
      @Balarock Před měsícem

      Same here, don't know why!!

  • @tohtoo9626
    @tohtoo9626 Před 4 měsíci

    What is the Max runtime when there is a power failure for a single door setup?