Webinar: Trying in Vain to Find a Vein: Ultrasound-Guided Peripheral IV Insertion

Sdílet
Vložit
  • čas přidán 28. 07. 2024
  • We recognize the value of point-of-care ultrasound better than anyone else, because it's all we do. FUJIFILM Sonosite is an innovator and leader in point-of-care ultrasound and our portable, compact systems expand the use of ultrasound across the clinical spectrum by bringing high-performance ultrasound to the point of patient care.
    Sonosite LX: www.sonosite.com/products/son...
    Sonosite PX: www.sonosite.com/products/son...
    All Products: www.sonosite.com/products/ult...
    Educational Resources:
    Webinars: secure.sonosite.com/behind-th...
    Sonosite Institute: www.sonosite.com/education/so...
    Our Website: www.sonosite.com/
    Social Media Channels:
    / sonosite
    / sonosite
    / fujifilm_sonosite
    / sonosite
    #ultrasound #ultrasoundmachine #ultrasonography #portableultrasound #pointofcareultrasound #bedsideultrasound #ultrasoundtraining #clinicalsupport #ultrasoundvideo #ultrasoundguidance #ultrasoundeducation #ultrasoundcourses #ultrasoundapplications #medicalultrasound
  • Věda a technologie

Komentáře • 6

  • @BruceLeigh-eu3wm
    @BruceLeigh-eu3wm Před 7 měsíci +1

    "I can't stand not being able to start an iv" I couldn't agree more.

  • @BruceLeigh-eu3wm
    @BruceLeigh-eu3wm Před 7 měsíci +1

    This is my white whale. I have thought several times about buying out of pocket one of those blue phantom practice blocks but those suckers are now $700. Very good video.

  • @thepalettewhispererasmr1227
    @thepalettewhispererasmr1227 Před 9 měsíci

    Awesome video-great tips.

  • @Shaw0817
    @Shaw0817 Před rokem +3

    I'm still learning and for some reason i tend to either lose the tip of the needle/difficulty seeing it on the screen and I also at times think im going in where the middle marker is but once i find the tip im either way to the left/right of the vein/marker. Any tips?? Thank you for the video!

    • @thepalettewhispererasmr1227
      @thepalettewhispererasmr1227 Před 9 měsíci

      I’m in the same boat....

    • @GDiet
      @GDiet Před měsícem

      The issue is likely angle of your probe. Your needle tip is most visible when you are at a perpendicular angle to the needle itself, not the vessel.
      Once you insert, slide your probe back close to your insertion site and adjust your angle to be roughly perpendicular. Once you visualize the white dot of the needle, maintain the angle of your probe and advance it up the patients arm until you lose vision of the white dot. You’ve reached your needle tip.
      If during the insertion you somehow lost the tip again, move the probate back to the insertion site and repeat the steps.