Septic cleaned out now my alarm is on.

Sdílet
Vložit
  • čas přidán 7. 09. 2024
  • How to stop reset your septic alarm after a clean out.

Komentáře • 42

  • @benb7727
    @benb7727 Před 3 lety +3

    Saved me a service call. Thanks!

  • @travisthompson3700
    @travisthompson3700 Před 2 lety +1

    Great info 👍 just had it pumped and alarm went off... From air pressure switch.... Just what I needed to know!

  • @Kerry.
    @Kerry. Před 3 lety +1

    Vivid commentary! thank you

  • @randypalmer2940
    @randypalmer2940 Před 3 lety +4

    mine alarm went off, ive reset the switches and it stays on. What are some of the easy things i can check before i call the local service guy and get charged out the ass?

  • @ElonMuskX
    @ElonMuskX Před 2 lety

    Hail storm put hole through top taking out red alarm light. Fixed the light but now in the run position I get a weak alarm fast beep and the light is barley lit all the time. Test function works like it should but have some sort of back feed???? I replaced the toggle for those test/mute function no fix

  • @briangallagher9510
    @briangallagher9510 Před 3 lety +2

    Thanks for the videos. Question though. What happens if the Manual/Test switch is left on Test? My alarm went off and I noticed this switch was set to test. Might that have caused the alarm issue?

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 3 lety

      It possibly could but something internally with the switch would have to be messed up. If nothing else was wrong then it was the switch.

  • @roberthughes2687
    @roberthughes2687 Před 3 lety +2

    How long does it take to fill a 1500 gallon tank under normal use in order to raise the low level alarm on the bio filter side enough to silence the alarm? Or how many gallons do I need in my tank before the level hits the baffle? Orenco tank

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 2 lety

      Don’t know a lot about orenco but the average gallons per person is 50-70 per day so take how many people if it’s empty. The times the number of people by 60 middle of the road and you will come up with how many days it will take to fill it up.

    • @roberthughes2687
      @roberthughes2687 Před 2 lety +1

      @@wholesalesepticsupply9801 took two of us about three weeks in case others want to know. Thanks

  • @Name-bd2lz
    @Name-bd2lz Před rokem

    Not sure how long but we notice our light on yesterday no noise ..just had it pumped out year ago in july looks full.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před rokem

      So the pump tank is full. If that is the case then the pump is out possibly.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před rokem

      Call the office Ruben will be able to talk you through it you will probably need to pump the pump tank only again unfortunately if you do need a new pump.

    • @Name-bd2lz
      @Name-bd2lz Před rokem +1

      I'm just seeing this yes that's what it was thanks 😊

  • @IronHorse2007
    @IronHorse2007 Před měsícem

    Dumb question. Why do you put water back in when you called to have it emptied?

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před měsícem +1

      @@IronHorse2007 on a aerobic septic a pump discharges the water in most applications. You are cleaning it to remove solids not water. Aerobic systems are sometimes fiberglass so it’s important they have weight added to them so they don’t float out of the ground is one reason. also the alarm switch needs back pressure to engage the switch properly or the alarm will go off endlessly until that tank has water in it. since it is the second tank depending on how many people that could be days so we fill the aerobic unit so this doesn’t happen.

    • @IronHorse2007
      @IronHorse2007 Před měsícem

      @wholesalesepticsupply9801 Thank you for explaining that.

  • @angelalugibill6215
    @angelalugibill6215 Před 2 lety

    Thank you so much!

  • @TheDentsRUs
    @TheDentsRUs Před rokem

    Thanks

  • @Kiskassklan
    @Kiskassklan Před 6 lety +1

    Good video..: Question. My alarm goes off after a few days. I go out and look. The breaker has been tripped. I reset the breaker which is a GFCI breaker in the electrical box. The pump comes on and alarm turns off, pump does it's job. Can the GFCI breaker be weak and tripping from a past old pump? It has been tripped many times. I had the float switch replaced thinking that was the problem but still tripping. Also does it have to have a GFCI breaker? Can I replace it with a regular 20 amp breaker? Thanks for any help.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 6 lety +1

      Howdy Doody yes gfci are not a good idea on septic systems do to the fact the effluent pump has a high lock amp at start.

    • @Kiskassklan
      @Kiskassklan Před 6 lety

      Thats what I was thinking. So even it being in the breaker box is best to get rid of it? I tried talking to my septic tank man on phone and he thought I was refering to a GFCI receptacle. Thanks again.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 6 lety +1

      Howdy Doody yes on 20 should do it as the master the control panel will have others but the max at any one time should be 17 amps with a rotary vane on it unless it’s a 3/4 hp.

    • @Kiskassklan
      @Kiskassklan Před 6 lety

      Wholesale Septic Supply Thanks again...that's what it was a bad GFCI breaker. Hasn't tripped in a week. Wish I had checked that first. Simple things first.

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 6 lety +1

      Howdy Doody your welcome glad we could help.

  • @CreateNowSleepLater
    @CreateNowSleepLater Před 9 měsíci

    I have this problem except the alarm is low pitch. If I hit the test button, its loud. Oddly enough, the red light was on and the alarm was loud before I got it pumped. Now, its just a low pitch sound but no red light. If I hit test, its loud again. If I put the switch to normal, its just thie low pitch. What is that about?

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 9 měsíci

      Sign of a bad float switch or the air alarm switch that the easy one to diagnose. Disconnect the air switch completely from the alarm. If it’s still low chirping then it’s your alarm float if it goes away it the air switch we will do a video on it.

    • @CreateNowSleepLater
      @CreateNowSleepLater Před 9 měsíci

      @@wholesalesepticsupply9801 Thanks for the reply, wound up being corroded wires in the tank!

    • @wholesalesepticsupply9801
      @wholesalesepticsupply9801  Před 9 měsíci +1

      @@CreateNowSleepLater connected the the alarm float.

  • @eclipse3356
    @eclipse3356 Před 2 lety

    One of our toilets ran all night and the alarm started going off. We've silenced the alarm, but the red light is still on. I've tried turning the system off for several minutes, but the red light and alarm came back on when I turned it back on. Any ideas what to do to fix it? I hate to call the septic company for something simple.

  • @marionr26
    @marionr26 Před rokem

    The guy that installed our system when our home was built Jan 2022 can't figure out why the alarm keeps going off. It has went long as 3 months when we first moved in. It now will go off just weeks after he comes and services it. Here now its gone off 3 days after he has left. Luckily it's under warnity until Jan 2024 but I'm tired of him coming out so often. He dud say he is not real familiar with the electronic part of the system. He has been out with a hose and done a two full system cleans on it. We only have 3 people in the house he has some with 6 people w no issues. He said he may try putting a new filter on it. I need help figuring it out. Thanks

  • @ev6625
    @ev6625 Před 2 lety

    Just bought a house and noticed the light looks like it’s dimly lit all the time. Is this normal or is it needing attention? When I test it, it does light up and the alarm sounds.

    • @ElonMuskX
      @ElonMuskX Před 2 lety

      Cover the light with your hands and see if it is lit or not

    • @ev6625
      @ev6625 Před 2 lety

      @@ElonMuskX yes, it’s dimly lit all the time. That’s why I’m curious if this is normal or means something?

    • @ElonMuskX
      @ElonMuskX Před 2 lety

      @@ev6625 No it is not normal... Mine is doing the same right now after a hail hit took out a light. In the run position do you get the alarm sound as well only softer and faster?

    • @ElonMuskX
      @ElonMuskX Před 2 lety

      what color light? How many lights do you have?

  • @wuwkiwan3447
    @wuwkiwan3447 Před 2 lety

    No bloody sound

  • @michaellanphere6992
    @michaellanphere6992 Před rokem

    Didn't work.