  • Analysis of Doubly Reinforced Beam where we find area of reinforcements tension as well as compression reinforcements, this is type 2 analysis problem.
    Type 1 : • Analysis of Doubly Rei...
    Why to provide doubly reinforced beam : • What is Doubly Reinfor...
    My Phone : amzn.to/311uFDW
    Amazon Basics 50-Inch Lightweight Tripod with Bag : amzn.to/3ayCdkG
    Laptop : amzn.to/3hi2yGp
    Limit State Design of Reinforced Concrete Design by B.C.Punmia : amzn.to/315UEu2
    Reinforced Concrete Design: IS:456-2000 Principles and Practice : amzn.to/315WLxY
    Illustrated Design of Reinforced Concrete Buildings : amzn.to/349rM62
    Design of Reinforced Concrete Structures : amzn.to/3142DYz
    #doublyreinforcedbeam #limitstatemethodofrcc #analysisofdoublyreinforcedbeam

Komentáře • 123

  • @aliyuumarsaidu5351
    @aliyuumarsaidu5351 Před měsícem

    Thank you so much prof. For sharing the knowledge

  • @aliyuumarsaidu5351
    @aliyuumarsaidu5351 Před rokem +2

    Thank you so much for impacting knowledge to the peoples

  • @Dineshkumar-gw7mo
    @Dineshkumar-gw7mo Před 3 lety +5

    Nice way of explaining sir,first time I will understand in youtube class,nyc sir

  • @bijkumar8510
    @bijkumar8510 Před 3 lety +2

    Sir you are very grateful teaching

  • @vamsiteja9184
    @vamsiteja9184 Před 3 lety +2

    Super explanation

  • @creativeventure9164
    @creativeventure9164 Před 2 lety +3

    Hi sir
    Iam studying steel structure now can u explain about bolted and welded connection and problems

  • @sathyabalasundaram1801
    @sathyabalasundaram1801 Před rokem +3

    Thank you, Sir. Nice Explanation.
    What is the Mu limit formula for Fe500 grade steel?

  • @Maheshbabubora
    @Maheshbabubora Před 3 lety +2

    Good morning sir.
    which Prescribed Textbook we follow To Learn about RCC, Along with your video lectures

  • @ndtech8170
    @ndtech8170 Před 2 lety +1

    Sir when we use this Mulim Formula please make a video.

  • @kingbisanka9689
    @kingbisanka9689 Před 4 lety +3

    Hello thanks alot for the great explanation...
    Also can u share the link of the SP document you're using...

  • @pragyanparamita4733
    @pragyanparamita4733 Před 4 lety +3

    We will not calculate shear reinforcements?? In doubly reinforcement

  • @shashankda2002
    @shashankda2002 Před rokem

    Thank you so much sir 😊. Want more videos please

  • @user-ch1qo6dl7y
    @user-ch1qo6dl7y Před rokem +2

    Sir dil de thank you 😊😊

  • @mohsinmanzoor9167
    @mohsinmanzoor9167 Před 4 lety +1

    Thnku sir ....sir plz upload a video on design of stair case ...becoz my exam starts from nov.....

  • @RohitYadav-pt8yd
    @RohitYadav-pt8yd Před 4 lety +1

    tq sir nad khula..😊💥

  • @prabhucivil5394
    @prabhucivil5394 Před rokem

    Sir ast at bottom reinforcement was clearly mentioned.for top side

  • @tejasparate1085
    @tejasparate1085 Před 3 lety +3

    If d' for tension side is 55mm and compression side is 40 mm then for finding fsc at compression stress what is the effective depth??

    • @theexecutioner3510
      @theexecutioner3510 Před 2 lety +1

      Then d'/d= 40/d
      Effective depth = D - 55, always calculate effective depth considering Tension reinforcement side.
      Kya yt teacher hai, bachhon ka doubt clear nahi karta.

    • @Gaurang_Khatri
      @Gaurang_Khatri Před rokem

      @@theexecutioner3510 10:45 bhaiya ye table is code me nahi h , to fsc kaise nikale exam ke time pr

    • @theexecutioner3510
      @theexecutioner3510 Před rokem

      ​@@Gaurang_Khatri hai. Baad mey batata hun.

    • @theexecutioner3510
      @theexecutioner3510 Před rokem

      Usually d'/d ratio denge tho table hota hi hai.

    • @Gaurang_Khatri
      @Gaurang_Khatri Před rokem

      @@theexecutioner3510 Achaa . Thank u very much

  • @rahulmaurya9003
    @rahulmaurya9003 Před 4 lety +1

    Nice way of explaing ,sir slab par videos banao na sir plz🙏

  • @dodouniquelife9725
    @dodouniquelife9725 Před rokem

    Thank You Very Much

  • @prasannalakshmikondapalli667

    tq sir

  • @narojamir1931
    @narojamir1931 Před 4 lety +2

    Sir plz explain how many number of bars should be provided in compression and tension......???

  • @akashgaming6090
    @akashgaming6090 Před rokem +1

    How to calculate working moment is given?

  • @jeevangowda5419
    @jeevangowda5419 Před 4 lety +1

    Sir plz solve Design on singly and doubly reinforced beams......thank you

  • @Rk003prk
    @Rk003prk Před 4 lety +1

    Sir aapke aal video helpful hai
    Design of doubly reinforced pr yek video bano sir

  • @kumarags9256
    @kumarags9256 Před rokem

    Thank you sir

  • @sumeetkalal6454
    @sumeetkalal6454 Před rokem

    Thank you

  • @gixerriders1993
    @gixerriders1993 Před 4 lety +1

    Upload continuous beam design also plz with codal provision

  • @rakshitshetty7084
    @rakshitshetty7084 Před 3 lety +1

    Sir finding fsc can you show calculating in calculate plzz sir, I'm confused 🙏🙏

    • @dipakrohit5993
      @dipakrohit5993 Před 2 lety

      Sp16,p-13,T-f me d'/d(d'=cover)
      d'/d ka ans 0.5,0.7,0.9 hoga usse
      0.5 ans hoga to fsc=355
      0.9 ans hoga to fsc=353

  • @awaljotkaur6854
    @awaljotkaur6854 Před 2 lety +2

    Sir, I have a query regarding section type. What if we get an under-reinforced section in case of doubly reinforced beam mentioned.. then which formula will we use, and the value of which Ast will be used there?

  • @tthimmanagoudattgouda3252

    Good explanation sir but plz design of dog legged staircase problem on video

  • @upcvanramkaitur5835
    @upcvanramkaitur5835 Před 3 lety

    How could we know to assume effective cover is 50 mm ??

  • @Rimjhimvideo
    @Rimjhimvideo Před 2 lety

    Thanks🙏🙏🙏🙏

  • @riyaawati5344
    @riyaawati5344 Před rokem +1

    Why did u equate Xu to xumax ?
    Are they both equal?

  • @PavanKumar-jp2ht
    @PavanKumar-jp2ht Před 3 lety +2

    Sir, IS-sp 16 formula is available in is 456-2000?

  • @Gaurang_Khatri
    @Gaurang_Khatri Před rokem +1

    10:47 sir but this table is not given in IS code so how can we determine fsc during exam

  • @abverma5636
    @abverma5636 Před 11 měsíci +1

    Factored moment ko ultimate moments m convert krne k liye 1.5 s multiple krne pdega???

  • @akhillanka4279
    @akhillanka4279 Před 4 lety +1

    Sir one Small doubt
    In analysis we find mu
    In design we find ast and asc
    But why did you write analysis when we were meant to find ast and asc

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 4 lety +1

      Nice question friend, you are correct finding Mu we call it as a analysis problem, but if you see here in this problem Mu is already given and they have asked to calculate area of reinforcement, i am not calling this problem as a design problem because, in design problem we calculate Mu and for that Mu we find area of steel and we apply all checks for design problems, here only ast was asked that too with given Mu that is why i am not calling this problem as design problem, i hope your doubt is cleared, thanks for commenting and keep supporting us

    • @akhillanka4279
      @akhillanka4279 Před 4 lety +1

      Thank you so much sir
      Your videos are really simple to understand
      It will be good if you upload one design problem sir
      Sir can I Know which book do you follow

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 4 lety +1

      Which design problem u need, i will do that, I refer many books and i write my own steps to make my viewers understand the concepts very easily

    • @akhillanka4279
      @akhillanka4279 Před 4 lety +1

      Sir Design of column (biaxial and uniaxial ).

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 4 lety

      Will come up with that part also soon

  • @Heman864
    @Heman864 Před 2 lety

    Love u sir

  • @hemanth._gowda
    @hemanth._gowda Před 3 lety +1

    Sir why xu value is not calculated ..
    Please clarify sir..

  • @khondokerazizulhaque357

    Nice

  • @67siddheshtiwale12
    @67siddheshtiwale12 Před 2 měsíci

    xu for doubly r. section = 0.87.fy.Ast-(fsc-fcc).Asc/0.36.fck.b

  • @bananimondal9389
    @bananimondal9389 Před 2 lety

    in my question Ast2 come more than Ast1 is it possible? concrete area come 1138.2 and Ast come 1956.16. Mu 240, Mulimit 101.56. so beam will be double reinforced beam.

  • @gdineshsai1326
    @gdineshsai1326 Před 3 lety +1

    sir how to solve simply supported beam carrying the udl problems..

  • @SantoshKumar-xz7im
    @SantoshKumar-xz7im Před 4 lety

    Ty sir ji❤❤

  • @sahilyousaf9265
    @sahilyousaf9265 Před 3 lety +1

    Sir, where did you get xu value

  • @erhasan6055
    @erhasan6055 Před 4 lety +1

    How to decide size of beam...

  • @prabhucivil5394
    @prabhucivil5394 Před rokem

    Everything is clear. But top reinforcement how to find it actual..

  • @raaj3017
    @raaj3017 Před 2 lety +2

    Good evening sir.
    Really great job that you are on CZcams with such great explanation on our Civil topics! First of all thanks so much sir 🙌🙌
    Also I am facing a problem in this particular design (beam design) sir.
    I am asked to design the beams subjected to Two-Way Slab, starting from load calculations. And the condition is that Mu must me greater than Mu(lim) but my value for Mu comes out to be smaller than Mu(lim), tried and changed the beam sizes, yet unable to satisfy the condition of BM.
    Sir could you please help out? Where is the design going wrong?

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  Před 2 lety +1

      Thank you so much for appreciating my content, keep watching.
      Can you tell me why you want specifically Mu greater than Mulim? Actually if you get Mu less than Mulim its good and you can design it as singly reinforced beam

  • @navneetyadav5782
    @navneetyadav5782 Před 2 lety +1

    Sir plz provide value of fy 250 for d'/d

  • @sreerejm8540
    @sreerejm8540 Před 3 lety

    sir, in calculation of Xu, d should be effective depth,not total depth.right? we get Xu 240 mm

  • @fitz4998
    @fitz4998 Před 8 měsíci +1

    Sir I’m getting the ASC as yours I’m getting 7.15

  • @banoththarun512
    @banoththarun512 Před rokem

    Sir what about the problem when supporting of udl

  • @shyamalkumar4767
    @shyamalkumar4767 Před rokem

    What is number of steel and it's layout.

  • @ashwiniv9874
    @ashwiniv9874 Před 2 lety

    how to calculate the number of bar when the number of bars is not given in the question

  • @harishhari6250
    @harishhari6250 Před 3 lety

    How to find that factored moment

  • @jigmewangmo8074
    @jigmewangmo8074 Před 3 lety

    Hello i have been asked to design doubly reinforced beam it does not qualify the condition of Mu > Mu lim? What shall i do?

    • @Prashuradha
      @Prashuradha Před 3 lety

      Revise the section. Or, design it as a balanced section.

  • @gangadharsanta1644
    @gangadharsanta1644 Před 3 lety

    I will not calculated over reinforced beam sir

  • @__for502
    @__for502 Před 3 lety

    Sir pls explain interpolation in another method
    Pls say the answer for d'/d is 0.11

  • @jyoshnaaddala4295
    @jyoshnaaddala4295 Před 3 lety

    👍

  • @nehabiswas6993
    @nehabiswas6993 Před 2 lety

    Please scientific calculator used krke calculation dikhai video main bohut problem hota hai

  • @swapnajkjk4856
    @swapnajkjk4856 Před 3 lety

    How the assumed the cover

  • @Jameer_zehan
    @Jameer_zehan Před 4 lety

    How to pass ...RCC exam simple tips give me

  • @mahendradhami1309
    @mahendradhami1309 Před 2 lety

    Book name??

  • @udayyenke5368
    @udayyenke5368 Před 3 lety

    Code books is important kada

  • @poovarasanpoovarasan8033

    Hi

  • @rccdesign591
    @rccdesign591 Před 3 lety

    Please sir pdf bhegeye

  • @BrajeshKumar-mz4xx
    @BrajeshKumar-mz4xx Před 3 lety +1

    Sir Hindi language

  • @nehabiswas6993
    @nehabiswas6993 Před 2 lety

    Ans nikalta nhi hain

  • @Hello_family111
    @Hello_family111 Před rokem +2

    Mulim page no of values u got that 0.138fckbd plz it’s urgent