FM200 PPM | Maintenance | Daily Checkup | Step By Step Full Video In Hindi | Service Engineer PPM
Vložit
- čas přidán 16. 10. 2020
- FM200 PPM | Maintenance | Daily Checkup | Step By Step Full Video In Hindi | Service Engineer PPM
In this video, you can learn how to do FM200 PPM properly step by step. This video is important for project & service engineer who is working in fire & safety industry. This video is also useful for those person who are working in facility industry.
If you are first time watch my channel so I request you to please first visit my channel videos & if you like my videos then only subscribe to my channel & also write comments if you want such valuable information.
Previous videos link
---FM200 Gas Suppression System | Installation & Working in Hindi • FM200 FM200 Gas Suppre...
---FM200 System Gas Release Panel Wiring & Connection | FM200 सिस्टम गैस रिलीज पैनल वायरिंग एंड कनेक्शन
• FM200 System Gas Relea...
---FM200 System Designing With Few Simple Steps | Important For Interview Question | English Subtitle
• FM200 System Designing...
---How to Design Conventional Fire Alarm System (Hindi) • How to Design Conventi...
---Ground Fault & Troubleshooting in Fire Alarm System in Hindi • Ground Fault & Trouble...
---Fault & Troubleshooting in Fire Alarm System in Hindi (Part 1) • Fault & Troubleshootin...
---Conventional Fire Alarm System (Explanation in Hindi) • Conventional Fire Alar...
#FM200PPM
#FM200maintenance
#FM200dailyroutinecheckup - Věda a technologie
Thank you Sir....full detailed explanation by you... Lots of thanks
Most Welcome
So informative and helpful thank you so much.
Thanks, pls share my videos in your company groups
Your videos are very helpful thank you
Thanks for your comment 😊
Pls share my videos in your company group
Sir Aap bhut achche se smjhaa kr btate hai thank you very much sir aisa video bnane ke liye
Thanks for your comment 😊
Pls mera videos share kijiye apny company group m
Tnq you Bhai ❤
Most welcome
Assalamalay kum sir before solenoid valve connect need to manually push inside solenoid valve pin no this is very important no sir thanks sir very good
Yes, it is very important, to connect before SOV, the pin should be inside & then connect slowly.
Thanks for your comment 🙂
@@Ansari29 how to reset the pin, manually we can or not
Yes you can
Thanks ❤
Most welcome
Thx share Your Experience and techniques
Thanks for your comment
Great
Thanks, pls share my videos in your company group
Nice sir
Thanks
Nice one shabaz. Looking forward more to come..
Thanks for your comment
Water Leak Detection System
czcams.com/video/Y4ZeFd9T4Jk/video.html
Water Leak Detection System Testing & PPM
czcams.com/video/AI9e8yle8WE/video.html
Must Watch
Addressable WLD Layout | Step By Step Understanding
czcams.com/video/BCQ2Y-Cr3FI/video.html
FM200 | Ravel RE-25AR Panel wiring 🔥
czcams.com/video/_6q0ursNZa4/video.html
Sir, how to open solenoid valve make a live video,
It's very simple just rotate clockwise for open slowly slowly
THANKS PLZ MAKE VEDIOES OF PRE ACTION , DELUGE MAINTENANCE
Ok, I will try to make video on it
Thanks for your comment 😊
Tnx boss
Thanks for your comment 🙂
Sir FM-200 ka manually maintenance ka video bnaiye thanks you 👍
Super
Thanks for your comments 🙂
For more such videos please visit my channel
FM200 | Ravel RE-25AR Panel wiring 🔥
czcams.com/video/_6q0ursNZa4/video.html
Sir please explain about fire alarm panel in side NDU and VCC
Video is good sir
Lekin main chij aapne batayi hi nahin
Agar ppm ki baat chal rahi hai to ppm daily hona hai,weekly hona hai , monthly hona hai ya yearly hona.
Mention kariye.
Zabrdst bro
Thanks Shahid bhai
Pls share my videos in your company group
Your videos are really very helpful Allah bless you bro
Thank you so much.
Bro can you plz share your what's app number or email address thanks
Sir,
Kitne saal bad fm200 ke gas cylinder refilling & hpt karana padati hain
Sir aap ek aisa hi video fire alarm system pe bhi bnaye
Ok zaroor banaoga
Carbon monoxide detector kisliye use HOTA hai connection details batayein
Battery bank room m install karty hai
G. fire pumps ( diesel and electrical ).Ka alram disable kisy krty hain
Sir plz make a video on public addressing system and its connection
Yes Nagaraj thanks for your suggestions
Pls share my videos in your company group
Bhai mujhe bahar jana hai to interview me kiya kiya batana padta hai bhi please batao na
Agar aap fire industry m job kiye ho atleast 1 saal wo bhi achy sy samaj k toh aap easily interview crack kar sakte ho, ab depends karta h ki aap kon si position k liye apply kar rahy ho
Basically aapko type of FAs, type of wiring connection, installation of detector & panels, maintenance work. Troubleshooting, project handling
Salamwaleku sir can you told me FM 200 system coming trouble alarm .
Can you tell me what is the broblam
How to solve this problem
Konsa alarm hai...
Great video, how to reset solinoid valve
Just put screw drive on solenoid pin, push back, it automatically get reset...
But there are many others type of Solenoid value & each one have different technique to reset.
@@Ansari29 thank you for your valuable reply
Hello sir
Hi
How to reset the head
Simple by pressing from Screw driver. But it depends on type of SOV. Some sov have reset pin so just insert screw driver & move towards the close end.
Abort switch press karne k baad kya action lena h
Before abort you have to check whether it's real fire or false. If real & u can control with fire extinguisher so press abort if you sure...or else false the immediately abort & check properly
Fm 200 ka ppm fire alarm technician karega ya fire fighting technician, please tell me Sir
Trouble ka barime bathadho bay
Pls check my videos
Bahe lifeco ka panel hai releasing truble show krta hai to ksy cler kryn
mrp 20001 ka progarame kasa hoga
Thx
Yearly test ?
Quarterly PPM by Vendors
Please make a video for addressable and conversational panel
Thanks for your comment.
Ya sure👍
Water Leak Detection System
czcams.com/video/Y4ZeFd9T4Jk/video.html
Water Leak Detection System Testing & PPM
czcams.com/video/AI9e8yle8WE/video.html
Must Watch
Addressable WLD Layout | Step By Step Understanding
czcams.com/video/BCQ2Y-Cr3FI/video.html
FM200 Gas Release Panel Commissioning
czcams.com/video/RaWbIHt-kTk/video.html
Assalamualaikum
Sir apke sath training krne ke liye koi option h
I am preparing fire alarm system course content. I will upload very soon
I like your video, please can you translate it in English so I can understand, tanks.
Ok, I will try to add subtitles in my videos very soon.
Thanks for your positive feedback 👍😊
Please translate it in Tamil so I cann understand pls thanks sri
RAC trouble show after maintenance switch is in normal mode while tighten the screw of solenoid valve but cant rectify this trouble
Check the resistor
Assalamualaikum Bhai ek control module aur moniter module aur relay module ka kaam aur connection btaye aap please
Walykum Assalam bhai
Mai ny CM MM ka video banaya hai aap please ek baar dhek lo
Control Module
czcams.com/video/qgpPu_Fxkps/video.html
Monitor Module
czcams.com/video/AZjpPwgV6a8/video.html
When we need to reset the Solenoid valve after resetting the gas panel or before
1st reset the panel then reset the SOV & also check twice before connecting to cylinder
Actually in my project, there is a maintenance switch, this one for disconnect power supply to the SOV, right
Is there auto/manual selection switch? If yes then in function check can we take the system in manual mode before removing solenoid from cylinder?
Yes there is an option for auto & manual mode switch,
You can kept cylinder in any mode while removing solenoid valve.
Must Watch
Addressable WLD Layout | Step By Step Understanding
czcams.com/video/BCQ2Y-Cr3FI/video.html
FM200 Gas Release Panel Commissioning
czcams.com/video/RaWbIHt-kTk/video.html
FM200 | Ravel RE-25AR Panel wiring 🔥
czcams.com/video/_6q0ursNZa4/video.html
Dear Ansari can you please tell me the reason why fm 200 cylinder showing low pressure on the gauge, because we install it before two month ago & now it showing low pressure.
1. May be gauge faulty
2. Sourounding Temperature
You can contact your OEM, they will definitely support for this issue....
It is possible you can clean fm200 detector without removing the solenoid valve? Thanks
As per method of procedure you have to 1st remove the SOV & then do a maintenance job
@@Ansari29 is its ok even when u not remove the sov when u clean detector of fm200..
As per my experience NO
Dear Sir shield FM200 panel zone 1 and zone 2 smoke detector is activated but solenoid not released.
And Manual release also not activated. Plz help sir
Check solenoid coil connection & also check voltage at panel end...24 V output should come...
@@Ansari29 voltage didn't come
Where.... Solenoid...?
Or Panel end....?
Fm 200 cylinder ka low pressure kyun hota hai and high pressure kyun hota hai aur hame kya Karna chahiye.
gas bottle leakage kisa check karana hai Uske bare Bata do Pls
Thanks for your comments
But app exactly puchna kya chahty ho...?
Sir Full form of ppm fm200
But we will not get signal of gas release on panel, as pressure switch is not activated, as we remove solenoid from gas cylinder.
When gas pass through the pressure switch module than only it will activate & give signal to the panel.
Soil ka panel common short bata raha hi ye Kaise thk ho ga wiring bhe thk hi
Hi,
Can you please share details on my mail id with panel pic,
ansari2991@gmail.com
Sar ji FM 200 mein gas hai aur pressure nahin hai to kya Karna
Pressure gauge replace karna hota hai...iskyliye cylinder ko factory bhejna hota hai ..On site ye work possible nhi hota hai... you have to contact OEM
Contact number
If fm 200 system is integrated with main fire alarm panel, then how to do PPM? If we follow the same process as you said then the main fire alarm panel is activated.
So please answer me asap
Yes it will activate, you can also check weather integration works or not. if you don't want to activate so 1st disconnect it & then activate. I hope this is clear to you.
@@Ansari29 how to disconnect could you please explain
One more thing bro, regarding reset the SOV, first we need to reset the panel then push the SOV pin insert, right
While testing I want to avoid access door closing, what should I do ?
For testing purpose, remove CM cable or remove cable from access control panel (Fire Relay)
Timer realy kyu lagaya jata hai.
I can't understand your English otherwise i understand how to pm gm 200 fire suppression
Thanks
A/s. Bhai silendar mo ges h ya nahi kesy check kary aur yh kitny rial kilo bhara jata h
Can u explained also in english thanks... F200 maintenance
Or English subtitles title thanks
I will try to add English subtitles in my videos very soon.
Please I hambal request
PPM KA FULL FORM KYA HAI
Pre Priventive Maintenance
OR Planned preventive maintainance
Fm200 fike company
Lps taraminesan
Ppm ka ful form kya Hota h sir
Pre Preventive Maintenance
Solenoid fault dekha raha hai
Kon sa panel hai apka...?
Sir PPM full form name
Pre preventive Maintenance
Thank you sir
Sir apke bahut ase video hai. or apke samjane ka tarika or prectical bahut asa hai. nice sir. Khubkhub dhanyawad.🤝🤝🤝🤝🤝🤝
Sir deluge valve Ravel panel ka video upload kariye. Please sir.
Thank you. Pls share my videos in your company group
Speak English please
Ok, I will try to add English subtitles in my videos
can I get your number sir
Sir fm200 ke smoke detector ko active panel ke samay remove kar clean Kiya ja sakta hai kya jaruri sawal hai jald ispar video banay ya reply de
Jub aap detector ko activate karty h usky baad aap detector ko remove kar k achy sy blower sy clean kary usky baad hi install kary.
Or ek imp chiz during PPM solenoid valve disconnect kar k hi rakhy or PPM hony k baad atleast 1 hour k baad hi dhiyan sy solenoid valve ko connect kary
G.agr GRP normal na ho tu?phir Kia Krty hain?
Try to resolved the fault first & them go ahead