Minimum & Maximum Distance Between Two Column | Column & Beam Size with Steel details for G+1 Floor
Vložit
- čas přidán 17. 10. 2020
- How to Calculate Development Length of Bar as Per IS 456 2000 | By Learning Technology
• How to Calculate Devel...
What is Ld | What is Development Length in Beam-Column Footing and Pile Cap | BBS
• What is Ld | What is ...
Difference Between Development Length and Lap Length
• Difference Between Dev...
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
• What is Lap Length | O...
Cutting Length of Lap Length and Development Length | Beam steel Details by Learning Technology
• Cutting Length of Lap ...
How to Read Measurement Tape | Feet | Inch | Meter | Millimeter | Cm | Soot By Learning Technology
• How to Read Measuremen...
What is PL, NTS, EOS, BOS, TOS, UGR, OHWT in Civil Engineering | Learning Technology
• What is PL, NTS, EOS, ...
What is GL, EGL, SSL, FFL, RL, IL in Civil Engineering || Difference Between GL and EGL
• What is GL, EGL, SSL, ...
Why RCC Slab Cracks after one day of Casting
• Why RCC Slab Cracks af...
10 Mistakes in RCC Beam Construction | 10 ग़लती जो बीम बांधते समय होता है |
• 10 Mistakes in RCC Bea...
What is 0.42 D in Crank Bar Calculation in Slab | How 0.42 D comes | Full Derivation of Bent up Bar
• What is 0.42 D in Cran...
What is SSL, SFL, FFL, EGL, GL in Civil Engineering Drawing
• What is SSL, SFL, FFL,...
Why We use Circular Shape Bar in Civil Construction
• Why We use Circular Sh...
What is Cutting Length of Steel Bar in (BBS) Bar Bending Schedule for Column, Beam & Slab
• What is Cutting Length...
Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best
• Welding, Lapping, Coup...
How to Calculate Percentage Cross-Sectional Area of Steel in Circular Column As Per IS 456: 2000
• How to Calculate Perce...
How to Calculate Percentage Cross-Sectional Area of Reinforcement Bar in Column as per IS 456:2000
• How to Calculate Perce...
Why We Do Not Provide Circular Beam in House Construction
• Why We Do Not Provide ...
Why We Do Not Provide Circular Column in House Construction
• Why We Do Not Provide ...
How to Calculate Void Deduction For Backfilling of Excavated Soil
• How to Calculate Void ...
How to Calculate Binding Wire Quantity for Reinforcement Steel Binding
• How to Calculate Bindi...
How to Calculate Number of Labour Required for Manual Excavation
• How to Calculate Numbe...
Estimate / Cost of Painting Work for House | Material Consumption and Labour Rate for Paint of Room
• Estimate / Cost of Pai...
How to Calculate Quantity of Lime and Glue for White Wash Paint on Wall
• How to Calculate Quant...
Tiles Cost for One Room | Quantity Estimation | Materials and Labour Cost
• Tiles Cost for One Roo...
Unit Weight of Building Material as Per IS 875 Part 1 for Billing
• Unit Weight of Buildin...
How to Convert 1 CFT of Stone chips Aggregate to Kg (Cubic Feet to Kilogram)
• How to Convert 1 CFT o...
Top 20 Unit Weight of Building Materials for Billing as per IS 875 PART-1
• Top 20 Unit Weight of ...
How to Convert Sand from CFT to KG for Billing at Construction Site
• How to Convert Sand fr...
How to Measure Stair Slope/Angle/Pitch Practically at Site by Measuring Tape
• How to Measure Stair S...
In this video, I am going to teach you Minimum & Maximum Distance Between Two Column | Column & Beam Size with Steel details for G+1 Floor
#MaximumDistanceBetweenColumn #ColumnBeamSize #ColumnBeamSteel #LearningTechnology #CivilEngineering #CivilEngineerMukeshSah
✔ Official Website in English
www.learningtechnologyofficia...
✔ Official Website in Hindi
www.civilofficial.com
****************************************************************
ABOUT CHANNEL
✔L & T - Learning Technology: This channel contains Technical Lectures on "Civil Engineering Topics like BBS (Bar Bending Schedule), Quantity Estimate, Rate Analysis, Surveying, Billing Estimate, House Construction, Civil Engineering Interview Question and Answer, Civil Site Related Videos, How to Read Civil Engineering Drawing, Building Estimate, Metro Rail Construction, Basic Civil Engineering Knowledge, Civil Engineering Softwares " from Personal Field Experience by Civil Engineer Mukesh Sah.
CONTACT DETAILS
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Twitter: / themukeshsah
✔Facebook Page: / learningtechnologyoffi...
✔ Linkedin: / civilengineermukeshsah
✔Instagram: / learningtechnologyoffi...
✔Pinterest: / learningtechnologyoffi...
✔Tumblr: / civilengineermukeshsah
Disclaimer:-
Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.
Sahi bole.. Gav k mistry apne app ko engg S v bda smjhte h.
🤣🤣
Aur engineers architects hote he 😂
Can I build 16,"fit colum and 15fit colum .yes or not.replay ans.
I am a contractor in village area, this kind of information is very useful to us. Thanks.
Way of explaining is such that everyone can understand
Your videos are very informative, upto the point and done dedicatedly., thanks.
Bahut acche tareekhe se, aur aasaan tareekhe se samajhaaya aap ne... Yeh chaanel unginit logom ko use hone waalaa hai sir...
Aap jo service kar rahe hai, uskeliye mera dhanyawaad...
Jai hind... Jai shri ram...
వందేమాతరం...
Thank you for your suggestion.
Thank you so much sir...
Really superb explanation...I am IT engg and by seeing this video i want to become Civil engg.
Ap bahot hi honestly samjhate...
Sir,you did a great job,every thing was very clear nd detailed,need sme information regarding tuff tiles strength.
very informative information, thank you, i'm also from village and planning to make house
Good, good and good information, sir👌from bangladesh🇧🇩
Useful information given sir
Thank u
Very good.There is clarity of explanation in it.Thanks.
Sir aapk batane ka tarika ek dumm perfect h , concept clear hojata h .
Thank you sir❤️
Great explanation ! 😍😍👍
🇹🇯 GOOD JOB SIR I AM CONTRAECTER IAM VERY HAPPY SIR YOU'RE GREAT 🙏🙏🙏🙏🙏 🌹🌹🌹👌👌👌👌 ALL THE BEST
Very much correct information. Thanks.
Thank you so much sir 🙏
Sir..
My house is based on approximately 750sqft. It is having 9mm columns with steel T12×4 in each.. there are 8 columns ...
I want to build 1st floor on it.. is it safe to build 1st floor on the existing structure we have now.??
I m really worried about it.. please give me a solution 🙏
Sir, this concept contradicts with the concept of Strong Column & Weak Beam.Any thoughts on that ?
What rods can be used for 30 feet span beam in ground floor for a g+1 building
Thx u sir for guidelines..
I appreciate your zeal to teach the people for proper construction of the building. I have a drawing with detail structure but I am not sure where and how much collumn should I put... Please let me know if you can help me too. I will send you the detail drawing if you will allow me to.
How abt columns from the tie beam to support an span of 17 feet ..in addition to the column from the foundation level....is it okay for a two storied building?
I have a question pls answer by making a video on it
As, in a vertical member like column, no lapping is allowed at L/4 from both ends ie.. no lap zone. My is question is that whether same rule is applicable in case the coupler is used in column?
Tq so much sir your great job...
Sir very much thankful. Very useful information we got. Thanks alot
Hi bro, this is Vijeeth. I have a small doubt regarding building safety.
We built G+1 building in a 1000sq feet plot (100sq yards)in 2011! Now we added a floor and a pent house on top of it. Which is G+2 and a pent house slab!
There are 9 columns of 9x12 inches cross-section! We used 4 bars of 16MM, 2 bars of 12MM in ground floor and footing. And 6 bars of 12MM in rest of the floors.
Now my question is - will it be structurally safe? I tried to run analysis but I lost touch in it! What is your opinion?
Good Reviews
Love from pakistan❤
❤️ ❤️❤️❤️ great..
Hello Sir...
With due respect I need to ask you if my span is 25 feet and i want end to end and wall merged column than what will be the size of column and beam???
Nice explain Sir thank you 👌
Thanx good information,👌👍
If there is a plan for constructing a home for G +3, in that case what size of columns we should provide
Wow well information.
Sir i really love u from pakistan . Sir i was restore mb and i miss your many videos
Well Explanation
Very knowledgeful Bhai
Em impressed
Bilkul correct Sahi jankari 👌🙏🙏
अचछि जानकारी.धन्यवाद
Sir,
16*40 ka suitable plan 1bhk
Steel, column, beam design for G+2
Thanks for information
Thank u so much sir ✌️
Excellent explanation of cutting length of beam rod
Superb👍👍👍
Good knowledge sir...
U teach so simple n clearly sir
Very nice video bhai sb
Sir I wanted to ask the width of the column is measured between the steel baars or its the outer size with concrete
वेरी गुड सार जी
Thank you sir.
Well explained sir ji
Sir my room size is 11'x14.75' and I have used 4 column with its size 9" X9" with 4 no of 12mm dia bar..... Is this correct?
Bhai, It’s good solution. Thanks.
Very interesting
Sir,
Is it possible to convert cantilever beam of ground floor into simply supported beam and also to extend it's length to bear the load of wall of 1st floor?
Sahi bole Sir 🙏🙏
yes you are right.thank for information.
Nice sir... Thank u sir
Nice explanation thanque sir
Sir I am planning first floor roof with red stone slate along with t iron and angle bars want to know your opinion about strength of the roof the area is eighteen by twenty eight
Very important topic. Good 👍
बहुत बढ़िया
God bless you sir.
Good information
Very very good advice sir...
Bhai village ka mistri ka bare me jo bole 💯 correct. Mera ghara me floor ka bi same problem, double material loss.
I have one doubt about center roof beam of room span 15 feet by 12 feet will be required or not ?
Well done brother, be ever bright and knight.
Bahut badhiya bhai
Thanks u sir..u r great
Ye jo masons wali bat ki ye sahi kaha ye apne aap ko top samajhte hain
God bless you. sir from Nepal.
I want to build G+2 house with 12inch *12inch column. Can i reduce the column size or reduce steel in 2nd floor column?
If i want to construct g+1 building and column distance fixed 5.5m or 18ft with column size 250×250 having 4 no 16 dia bar is it risky
please clarify
Size of beam is more important ..as spacing between two colum is 5.5 m ..Use beam 250x300.. min depth of beam .5500/20
Good message
Thank you bro
Awesome video Sir
Badhiya dhanyabaad
I'M planning to build G+1 storey
Given 12MM 6 bar with 10" ×12" pillar...
Total 12 pillar home in 1000 SQ ft.
space between two pillar in middle is 16ft and remaining is at 12 ft and 9ft...
Will there be any issue with 16 ft pillat in this structure?
Mistri ke bare me aap sahi bole.
Great work 👍👍👍
very good...👍
Nice class
Can we provide 7m span between two columns? Then what may be the sizes of cross section of columns and simply supported beam?
Thank you sir
धन्यवाद.सर.
TAnks.good.advis
thanks 😊
Which type of support can be used for ceiling by using fibre cement board 20mm in Mangalore tiled home
Nice information thanks
Thanks for the video...I want to erect an boundary wall On a paddy field. There are no roads nearby. So, is 8mm or 10mm rods to choose?
Accha laga apka video
Very nice concepting.thanks.
How Max sft roof can I struct with 4 pillars at ground level height of 10feet
Thank u so much sir hi
Best gyan salute sir
Explanation is soooper sir common people understand, site me too good hota hai,
Thanks.....sir
Thnks sr!