What is the Minimum and Maximum number of Reinforcement used in Column || By CivilGuruji

Sdílet
Vložit
  • čas přidán 10. 03. 2022
  • What is the Minimum and Maximum number of Reinforcement used in Column
    Start Your COPs Training NOW
    Join this Training and get started:- civilguruji.page.link/F6m2mK1...
    For More Details Call Now : 9111001234
    Get the AR Experience :- civilguruji.com/
    About This Video -------------------------------------------------------------------------------
    In this video Er. Sudeep Kumar Agrawal, Corporate Trainer of Civil Guruji, is Explaining About What is the Minimum and Maximum number of Reinforcement used in Column
    What is the Minimum and Maximum number of Reinforcement used in Column
    The percentage of steel should be minimum of 0.8% of Gross area of the section and maximum of 6% of Gross area, but the maximum area can be restricted to 4% of Gross area so as to avoid conjustion of reinforcement while concreting.
    Minimum number of bars for rectangular column is 4 and Minimum bars for circular column is 6.
    Minimum Diameter of the longitudinal reinforcement is 12mm.
    Minimum diameter of lateral reinforcement is lesser of 6mm or one-fourth the diameter of Main reinforcement bars.
    Minimum clear cover should be 40mm.
    The minimum size of rcc column as per IS 456 : 2000 is 9″ x 9″, contain steel reinforcement of 4 bars of 12mm with stirrups of 8mm steel rings at a distance of 150mm centre to centre.
    Minimum cross-sectional dimension for a Column: is 9”x 9” (225MM x 225MM). But to avoid slenderness problems, I recommend a rectangular column design of 9″x 12″ (225 MM x 300 MM) which is safer. What is the Minimum and Maximum number of Reinforcement used in Column
    I always recommended to use use M20 grade concrete for construction, as it is the minimum recommended grade of concrete is IS 456:2000. Please don’t skimp on the quality of concrete. The minimum steel in a 9″ x 9″ column is 4 bars of 12 MM with stirrups of 8 MM steel rings at a distance of 150 MM centre to centre. In a 9″ x 12″ column, I add two more bars, to take the total to 6 bars of 12 MM diameter. This design can be safe for up to G+1 floors. But there are a lot of other factors involved. What is the Minimum and Maximum number of Reinforcement used in Column
    Follow our Official Social Media pages-
    You Can Also Download Our Mobile Application :-
    play.google.com/store/apps/de...
    Join Our Telegram Group
    t.me/JoinCivilGuruji
    Like Our Facebook Page :-
    / 411013642352412
    Follow us on Instagram
    civil_gurujii?i...
    And, Grow your Practical & Software skills.
    minimum and maximum reinforcement in column as per is 456,maximum and minimum reinforcement in beam,maximum and minimum size of reinforcement,column reinforcement,maximum and minimum reinforcement,what is the minimum reinforcement in a column?,reinforcement,minimum reinforcement,minimum % of reinforcement in column,maximum steel percentage in column,minimum steel percentage in column,maximum percentage of steel in slab,minimum reinforcement in column,civil engineering
    How to Perform Profile Levelling on Highway Construction | Profile Levelling
    #Minimum #Maximum #number #Reinforcement #Column #TMT #Construction

Komentáře • 17

  • @shakilurrahman5725
    @shakilurrahman5725 Před 2 lety +2

    Excellent knowledgebal video sir

  • @bhupendrajayswal276
    @bhupendrajayswal276 Před 2 lety

    Thankyou shudip bhai ❤️❤️❤️for important knowledge

  • @shaikhumar3129
    @shaikhumar3129 Před rokem

    Very Understand me

  • @puranrajak1987
    @puranrajak1987 Před rokem

    Good morning happy Holi day sir

  • @acty6067
    @acty6067 Před 2 lety +2

    make some videos. online courses on Estimate of Irrigation Engineering structures

  • @harendrakumarchaudhary
    @harendrakumarchaudhary Před 2 lety +1

    🙏🙏🙏

  • @chimseboy5650
    @chimseboy5650 Před 2 lety +2

    Thank you sir fee Kitna hey from Nepal ❤️

  • @udaykumar-pu8zf
    @udaykumar-pu8zf Před 2 lety

    thank you for infromaction sir minmum and maximum concreta in column how much sir pleasr make video

  • @dhruvkumar3143
    @dhruvkumar3143 Před 2 lety

    Beam upper bhi video bana dijiye

  • @aspirant..p..2204
    @aspirant..p..2204 Před 2 lety

    🔥🔥

  • @krishna_raj9331
    @krishna_raj9331 Před 2 lety

    Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..?
    The column to column distance is 15 feet.
    How many storeys can be built with this much reinforcement..?

  • @ashishsrivastava7264
    @ashishsrivastava7264 Před 2 lety

    Sir I need COPs Professional course for lifetime validity.

  • @status9755
    @status9755 Před 2 lety

    Load k hisab se
    Agr colm 1percent maang raha hai
    Waha pr 0.8 percent provide kr diya toh?????

  • @chimseboy5650
    @chimseboy5650 Před 2 lety

    Sir 1 column different different bar Lagta hay uskliya kse pata lagata hey yaska ko koi video banya or
    No of bar :-9.96 Aya to ten hota hey ki 12 ?

  • @SonuKumar-pk4pl
    @SonuKumar-pk4pl Před 8 měsíci

    Sir acc to is code max rein 6% but calculate kiya aapne 4%
    How 😮