    In this video is a install and review of a Tri fuel conversion kit from US carburation/ Motor snorkel. This kit doesn’t void warranty and is the correct way to properly run natural gas and propane while still being able to use gas any time. Don’t do the DIY home kits as they can be dangerous and even lethal. Hope you like the video and smash 💥 that like button and subscribe 👍🏼
    #generator #invertergenerator #honda3000is
    Use the PROMO: JOHNNYSWKS at
    motorsnorkel.com
    to receive a free hour meter/tach with your purchase of a tri fuel kit. Expires 30 days after video release.
    LINKS FOR ITEMS IN VIDEO....
    Power Meter build: • Volts Amps Watts Meter...
    DEWALT TITANUIM Drill bit set: amzn.to/3GIiJtl
    RV Quick Connect Hose 18ft: amzn.to/3H0JucC
    Y adapter: amzn.to/30849uX
    350 watt Heater : amzn.to/3o2uwud
    Battery Meter: amzn.to/3kegDrz
    Ask me direct for fast response asqme.com/@johnnysweekends
    Everything ECOFLOW Discounts!!!!
    PROMO CODE: JOHNNYSWD modernhouseusa.com/collection...
    FULL SOLAR KITS & ECOFLOW , BUNDLE AND SAVE!!!
    shopsolarkits.com/1134
    Trailer and vehicle accessories
    www.etrailer.com/?etam=a0017
    Lithium SOK Batteries Solar and more!! currentconnected.com/?ref=JW
    Level your trailer FAST & EASY!!!!
    Level mate pro: amzn.to/3S2xf5c
    AWESOME BUDGET BATTERY Chins w/ low temp and blue tooth! amzn.to/3IOjVfv
    MC4 All in one Kit : amzn.to/37jwLVb
    Surecan Gas can : amzn.to/3Kf5rqn
    303 Aero space Protectant: amzn.to/329dkM7
    Outland Propane fire pit!! : amzn.to/3rKIkwZ
    Generator tent amzn.to/3ddd3ds
    Lucas fuel treatment: amzn.to/3IfxQv8
    West coast Camping group join
    / 1771083136386739
    Videos are for entertainment purposes only. Do your own research when it comes to using these products shown in any Johnny's Weekends videos.
    Thanks for watching. Above links are part of a affiliate program. As an Amazon Associate I earn from qualifying purchases, if you purchase something I earn a small commission, if you do thank you so much as it helps creators like me to continue to bring content for viewers.👍👊😊

Komentáře • 447

  • @johnnysweekends
    @johnnysweekends  Před 2 lety +15

    Hope everyone likes the video. This Really is such a simple kit that performs great. Having the options are nice. For the most part….😂😂 “insider joke” watch to find out…😁👍🏼

    • @trialnsuffering9731
      @trialnsuffering9731 Před 2 lety +2

      Sir,
      Thanks for sharing this was very incite-full.
      Question: seeing how easy you made it look converting a gasoline to propane. Is it possible to modify to work with an “HHO” fuel source? I’ve seen videos where they use drinking water mixed with an electrolyte (usually baking soda) and a battery of 14v to produce hydrogen. The hydrogen is then used as a fuel source.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      This would be a great kit to try this with. I may have to mess around at some point when I have time and see if I can make it work..👍🏼😀

    • @josesoriano6738
      @josesoriano6738 Před rokem +1

      Thanks for sharing this video do you have the link for the generator kit

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      I thought it was in the description..🤔
      Let me check and update

    • @josesoriano6738
      @josesoriano6738 Před rokem +1

      @@johnnysweekends it’s I found it thank you

  • @joyvillanueva9743
    @joyvillanueva9743 Před rokem +41

    *A quiet **Generater.Systems** , love the dual fuel capabilities, camper is 50 amp but the adapter helps and found it still handles the load. Haven't taken a camping trip yet, that's in a couple of weeks. Will see how well it does over a long weekend.*

    • @johnnysweekends
      @johnnysweekends  Před rokem

      Yes and no.
      If you know what you are doing yes, if you don’t then no.
      I would say no if you are asking the question.
      Because it can be dangerous if you don’t know what your doing

  • @johanv4668
    @johanv4668 Před měsícem +2

    this is also a realy good kit for people that are experimenting with wood gas systems. to have a good regulator

  • @jeffjones4619
    @jeffjones4619 Před 2 lety +12

    Another well done video by Johnny's Weekends! Always look forward to the next one.

  • @JJHDZ68
    @JJHDZ68 Před rokem +4

    And For the most part, I learned a bunch from you today!
    Blessings to you and yours 🙏 ✨️ 💛

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      Thank you so much, glad it helped.
      And for the most I don’t say that to much any more, sometimes you get stuck on a phrase for a while, so for the most part I stopped saying it…..🤔😂👊🏼🙌🏼😊

  • @patriotone755
    @patriotone755 Před 2 lety +1

    I actually ordered the Hutchmountain LP conversion kit for my new eu3000i, pretty much the same kit. Your video is excellent.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Yes they are pretty much the same and thank you. I appreciate it..😀👍🏼

  • @patricknichols7399
    @patricknichols7399 Před 2 lety +11

    For the most part really enjoyed the video. Glad it worked out very easy for the most part.

  • @GH-wt7ww
    @GH-wt7ww Před rokem +2

    Those kits from US carburation work well have used on 2 inverter generators. Nice work on the Honda nice and clean. Thanks for posting.

    • @johnnysweekends
      @johnnysweekends  Před rokem

      Thank you and yes so far they work great. Minimal to do once set up. Just prime and go.

  • @nelsonericreed6439
    @nelsonericreed6439 Před rokem +1

    I LOVED your talking,,, the speed, your jokes,,,, I subscribed just to hear you talk. But yes, information is very helpful for me as well cuz I'm thinking about doing the same thing. THANKS!!!

    • @johnnysweekends
      @johnnysweekends  Před rokem

      Lol awesome thank you. And hope to see ya around in more videos 😀👍🏼

  • @yodamann7382
    @yodamann7382 Před 2 lety +3

    Great, i did same , same kit , added to my Champion 9000/7200 , after testing, i removed the fuel tank completely, i use for my house backup only , works great onHouse gas and propane.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Awesome….!!
      Yea I think o may use it on a different gen with more power. The Honda is good but doesn’t run much. Although I don’t need much so who knows. I’m always doing something.

  • @DixieNormas
    @DixieNormas Před rokem +12

    For the most part this was quite informative, and for the most part I appreciate the effort you put into doing them. So I guess what I'm saying is that for the most part, THANKS!!!

    • @johnnysweekends
      @johnnysweekends  Před rokem +3

      Lol well thank you. It’s nice to know someone appreciates it, I mean for the most part 😂👊🏼👍🏼

    • @DixieNormas
      @DixieNormas Před rokem +1

      @@johnnysweekends Ordering my kit now!!!!

    • @johnnysweekends
      @johnnysweekends  Před rokem

      Awesome..😀👍🏼
      Let me know if the links are all still correct 👍🏼

    • @DixieNormas
      @DixieNormas Před rokem +1

      @@johnnysweekends Yes sir, still working.

    • @johnnysweekends
      @johnnysweekends  Před rokem

      Ok thanks, sometimes you never know..🤷‍♂️

  • @auggies
    @auggies Před 2 lety +3

    This is on my list to convert my generac. Many thanks.

  • @DBRGB
    @DBRGB Před rokem +1

    Excellent, excellent, excellent video instructions. Great job!!!!

  • @damianstrudley2265
    @damianstrudley2265 Před 2 lety +1

    Brilliant idea. Look forwards to trying that out

  • @montgomeryenyansororji1666

    This is a great innovation I should have, promote it's development and help market in my country

  • @brianfuerst9491
    @brianfuerst9491 Před 4 měsíci +1

    Really good presentation!

  • @russf6572
    @russf6572 Před 5 měsíci +1

    Wow! Professional install and testing makes me wish you were my neighbor! I've got a Honda eu2000i and a motor snorkel conversion kit. Hopefully mine will go together and work as well as yours. Thanks for the video.

    • @johnnysweekends
      @johnnysweekends  Před 5 měsíci

      Thank you. It’s pretty easy, so im sure you’ll do fine. Check for leaks…these are great as i have used these in several videos…amzn.to/49gomMO

    • @johnnysweekends
      @johnnysweekends  Před 5 měsíci

      Here is the video….Amazingly Simple Gas Leak Detector For RVs
      czcams.com/video/DPFediHYIoc/video.html

  • @c-martz2846
    @c-martz2846 Před 2 lety +1

    Great tutorial! Thanks for sharing

  • @user-hb8be5wb4q
    @user-hb8be5wb4q Před 2 lety +1

    Ordered my dual fuel about three years ago. Haven’t needed it yet, but, better need it and we have it.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Options are always nice. Especially if your set up for 3 types of fuel.
      👍🏼

  • @USCarburetion
    @USCarburetion Před 2 lety +6

    Excellent video! We were sure glad to get to work with you and we are glad you like our kit!

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +2

      Thank you. It’s a easy install for sure..👍🏼
      Now I can hook directly to the trailer or my home.
      Thanks again…👍🏼😀

  • @rascalme9754
    @rascalme9754 Před 2 lety +2

    Explained fast and clearly!

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Thank you…👍🏼😀

    • @rascalme9754
      @rascalme9754 Před 2 lety +1

      Too many posters drone on and on, thoroughly enjoyed your style. 👍

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Thank you, I know I dont have time for watching that, so I don’t wanna deliver it to my viewers. GET TO THE POINT!!!! 🤣🤣🤣👍🏼
      Thanks for the comment and thanks again for watching 👍🏼😀

  • @troyyarbrough
    @troyyarbrough Před 2 lety +1

    I recently purchased the WEN RV-Ready 4000-Watt Open Frame Inverter Generator. I also purchased the Sportsman 4,000/3,500-Watt Dual Fuel Powered Portable Generator. I have to say I like the Sportsman setup with a 20# propane bottle much better than using gasoline. My Wen inverter/generator does not have the propane option, but now it looks like I can convert it with one of these kits. Thanks for making this video.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      No problem they are simple to install and tuning isn’t hard as well.
      Thanks for the comment and thanks for watching 😀👍🏼

  • @lsk-nf7um
    @lsk-nf7um Před 2 lety +1

    Informative for the most part.

  • @canadafirst7072
    @canadafirst7072 Před rokem +1

    Excellent video

  • @bernie2180
    @bernie2180 Před 2 lety +1

    Good video brother!

  • @percyfaith11
    @percyfaith11 Před rokem +1

    Nice video Johnny.

  • @tristanschaper281
    @tristanschaper281 Před 2 lety +2

    Great vid! I installed this on my Yamaha 2000i inverter gen and I love it. I’m thinking of installing on my big Honda eu6500 for home backup.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      That would be a excellent place for it. I use the smaller gens for portable and the bigger for home when needed.

    • @WL-gx2tn
      @WL-gx2tn Před 2 lety +1

      I just ordered a propane carb adapter for my eu6500is on ebay for 59 bucks. I have the regulators from my other propane setups.

  • @n.b.p.davenport7066
    @n.b.p.davenport7066 Před 2 lety

    Nice work excellent video, thumbs up..

  • @Rockhound1943
    @Rockhound1943 Před rokem +1

    fantastic video great tips. Thanks

  • @richardclark8520
    @richardclark8520 Před 2 lety +1

    Good instruction video. “ For The Most Part “ 😊

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      🤣🤣👍🏼👍🏼👍🏼
      Thanks for watching 😀👍🏼

  • @julianfs35
    @julianfs35 Před 2 lety +1

    Great video👍👍👍

  • @hoochthefireman
    @hoochthefireman Před 2 lety +5

    I have installed this on my Ryobi 2300 inverter generator. I actually run it off natural gas. Installing a gasoline shut-off valve to the generator was the only extra step I had to do. It runs well. They say you lose some power with natural gas and propane. Maybe 20%, but I do not know how to test that. Because of my work schedule, I love that I don't have to worry about refueling it. EVER.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Yes on the small gens they want you to run a separate fuel shut off which I have. But because how the larger Honda is you don’t need to.

    • @hoochthefireman
      @hoochthefireman Před 2 lety +1

      I saw that your Honda had its own shut off.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Yea the big one has and the new small 2200 but I think on that model they want you to still use the accessory fuel shut off in a small kit they provide.

    • @juliogonzo2718
      @juliogonzo2718 Před 2 lety +1

      @@hoochthefireman you probably could have just pulled the wires off the existing switch on the valve and ran them to a rocker switch. If I do propane on the little generac I bought (same as the ryobi with different case and control panel and no Bluetooth) that will probably be what I will do. Not sure what to do with the choke then however

    • @hoochthefireman
      @hoochthefireman Před 2 lety +1

      @@juliogonzo2718 I'm not sure what you mean. I put an in-line gas shut off to be safer. Plus I wanted to keep the ability to run gasoline if needed. My generation of the Ryobi 2300 didn't/doesn't have what you're talking about. I appreciate the tip though.

  • @MrUlikemen
    @MrUlikemen Před 2 lety +2

    For those most part.. this looks pretty good.

  • @RatsAndFunTV
    @RatsAndFunTV Před 2 lety +1

    Very usefull video. Thank's.

  • @alexs-zq6ni
    @alexs-zq6ni Před 2 lety +1

    Looks great

  • @dougc190
    @dougc190 Před 2 lety +3

    I have an older us carburation/Moto snorkel propane kit on my Yamaha 2800. I did this back in the early 2000s. I have the block that goes in front of the carburetor instead of the snorkel. With the block at least for mine it will not run on the eco, it's good to see yours will with the snorkel. I plug mine into the house, and with running a swamp cooler refrigerator and freezer TV internet certain led/florescent lights I went 6 hours on a 20 lb 5 gallon propane tank and still had some left in it. It will also run my heater but my heater is propane in the house. Now the 2800 does have a hard time starting to swap cooler you have to do that first and then add everything on. That's cooler has a hell of a starting load
    Anybody cares click on my name I have a couple videos of the generator running with the house.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +2

      Awesome yea they are nice kits and sure opens up options 👍🏼

  • @bassmith448bassist5
    @bassmith448bassist5 Před 2 lety +2

    I would also check for 60 cycles at the outlet as well.

    • @bubbatime
      @bubbatime Před 2 lety

      its an inverter. It will always be at 60 hertz. On a regular generator, sure.

  • @carlocastelli7511
    @carlocastelli7511 Před 3 měsíci

    The modification is shown and executed very well but I have a critical observation to make. You Americans are for functional practicality but we Italians also like (in addition...) a pleasant aesthetic. In short, I don't like seeing the pressure reducer attached to the door and drilling it too! I would have preferred to install it under the generator where there is the basket with the wheels, at the pressure reducer an elbow fitting (90°) for the gas inlet... and a protective casing.. For the rest.. 👍 😊

    • @johnnysweekends
      @johnnysweekends  Před 3 měsíci +1

      I moved mine to the rear bottom right corner. I didn’t like the door either and wished I had looked at it a little longer verses going with the instructions

  • @SeanBaker
    @SeanBaker Před rokem +1

    great video!

  • @aptorres01
    @aptorres01 Před rokem +1

    Great video thank you

    • @johnnysweekends
      @johnnysweekends  Před rokem

      You’re welcome and thanks for watching 😀👍🏼👊🏼

  • @stephenhill6143
    @stephenhill6143 Před rokem +1

    I don't "smash" like buttons, but I enjoyed your video. Thank you.

    • @johnnysweekends
      @johnnysweekends  Před rokem

      I’m glad you enjoyed the video and hope it helped you out. And it’s ok you don’t have to smash 💥 the like button. But it is fun 😂😉👍🏼

  • @thereisnotry1386
    @thereisnotry1386 Před 2 lety +1

    Good job, "for the most part".

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      😂😂😂😂👍🏼 between that and one other word I use a lot.
      Better then saying ummmmm all the time and like….🤣

  • @jimderksen1653
    @jimderksen1653 Před 2 lety +1

    I like this video...for the most part.

  • @davidhodge3894
    @davidhodge3894 Před 2 lety +2

    Very nice

  • @stonewall6551
    @stonewall6551 Před 2 lety +2

    its always good to have backup choices LPG has 38% less energy thn gasoline propane is normally alot higher cost per gallon 4.6 gallons should be a full fill on a 20lb cylinder but many underfill only way to know is weigh it propane is 4.24 lbs per gallon weigh cylinder then subtract tare weight of cylinder ( stamped on cylinder) i find alot only fill 15lbs of propane
    propane is better overall for engine because it goes in as a gas and dont have cylinder/piston
    wash down caused by gasoline

  • @mikecon7634
    @mikecon7634 Před 2 lety +1

    Tks JW

  • @zalsweadi
    @zalsweadi Před rokem +1

    Brilliant

  • @__WJK__
    @__WJK__ Před rokem

    Great channel. So, is the reg orientation specific or could it maybe be mounted horizontally/flat beneath the generator(?)

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      I don’t think it matters to be honest but you could do a temporary mount and then fire it up and run small loads. If it works then great but may be subject to dirt and debris more like that..
      And thank you..😀👍🏼

  • @mwapetembo697
    @mwapetembo697 Před 2 lety

    How do i determine the type and kind of fuel conversion kit for my RYOBI RG-7900K generator?

  • @usphisics
    @usphisics Před rokem +1

    Hahahah, I like the piano part..... Your comments are the best

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      😂😂 yea I throw little things in here and there to see if anyone picks it up or how much they are paying attention. 😂👍🏼

  • @MrPatdeeee
    @MrPatdeeee Před rokem

    Your Title said "TRI" Fuel. And you sure made it use Propane perfectly. Great!. But I want ONLY NG in my home when; we lose power.. So why didn't you show us how; it works when using NG? Huh?
    I NEED it! Thanks.

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      You need to ask a little more politely.
      I didn’t receive a NG connection kit. Which can vary depending on your home. Which you should have someone hook up if you T off a line from the gas feed. I’m not going to show you because I don’t know what your doing or your hookups. So liability wise it’s not in my best interest.
      And NG has a lot less btu’s then propane and even more so then gas. It’s like 5 gallons of NG to every 2 of gas and 3.5 ish for propane…… roughly.
      I showed how to install the kit and that it works on gas and propane and NG won’t be much different but a adjustment will be needed depending.

  • @calvingreene90
    @calvingreene90 Před 2 lety +2

    Holy crap! He found his 10mm socket.

  • @chesterfranklin2642
    @chesterfranklin2642 Před 2 lety +1

    Finally got my kit. After watching the video, there are some parts that I don't know their use. There are two short bolts. What are they used for? There is a tiny screw (Bolt) that I don't know its use either. I noticed you did not use the flat washers. Where exactly are they supposed to go? My kit did not come with a grommet, but I have one. Your advice is appreciated, before I start this project.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Sometimes they do give you extra parts for different mounting areas.
      Did you lay everything out. There really isn’t a whole lot of parts needed. I used a few of my own because I mounted the big regulator on the gen on the door but actually removed it and mounted it on the rear right side kinda low. Took the back panel off. But tubing is ran the same.

    • @chesterfranklin2642
      @chesterfranklin2642 Před 2 lety +1

      @@johnnysweekends Got it. Thanks.

  • @kennedy67951
    @kennedy67951 Před 2 lety +1

    I'd like to see you put this Regulator through another test using GASOLINE VAPOR, BUTAIN, CARBIDE GAS and HYDROGEN GAS if possible. Would you do these test using these types of Fuel? Thanks for the upload.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Would be a good test but I don’t think the regulator is designed for those types of fuels. Would have to see what the density is of NG and propane and compare I guess to see. Not to familiar with burning carbide gas.

  • @johnr5545
    @johnr5545 Před 2 lety +2

    Nice job god bless

  • @rupe53
    @rupe53 Před 2 lety +16

    Interesting and easy to install. Overall, a nice job. Yes, you will use more propane / NG than gasoline and that's because those fuels have less BTUs by volume. OTOH, those fuels do burn cleaner and don't go bad with time. (stale gasoline anyone?) That said, my primary concern with any of these conversions is invalidating the gen set's warranty (your call there) and the UL listing. Basically, the UL listing is about the unit being tested as "safe for it's intended purpose, as designed by the mfgr" You make changes / modifications on the unit and the factory's liability is no longer there. (I.E. burn the house down, blow yourself up, etc)

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +3

      Agree but much better then the kill your self DIY videos going around for NG. Straight line to the green and no regulator. Meaning if the gen shuts off, the gas still flows and if your asleep or not around your creating a bomb for you and your neighbors.

    • @rupe53
      @rupe53 Před 2 lety +2

      @@johnnysweekends .... all UL approved gen sets have a second means of automatic fuel shut off via an electric gas solenoid AND a demand regulator. If the engine dies (low oil?) the gas is also shut off. The demand regulator you have *SHOULD* shut the gas off if the engine dies but this does NOT have a secondary safety.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      The DIY videos that are going around for converting a gen to NG is a valve on the outside of the house. Then a extension line ran directly to the generator air box in front of the carb throat. Your turn the gas on by the valve then the generator on and control the mixture at the hand valve. That’s it. That’s what people are doing. There is no safety there. So if the gen shuts off for any reason the gas supply is free will. It will bleed out of the air box and everywhere.
      This is what is going around on other videos.

    • @rupe53
      @rupe53 Před 2 lety +2

      @@johnnysweekends ... I serviced gen sets for 25 years and have seen many (bad) things, but that's insanity! The style you feature has been around for decades and at one time was approved, but that was before people got law suit happy.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      It’s true. No one is liable for there own stupidity anymore lol. But yea the conversion set has been around I guess a long time. They work good though. But maybe install after warranty is up 🤷‍♂️
      But yea you should look for the video. I may even make one on saying “don’t do this” lol before we see people on the news.

  • @bjty5615
    @bjty5615 Před 2 lety +1

    New at this can you add a gauge to indicate how much is left in your propane tank?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Yes you can and there are a couple different types. Now for the most part they are not super accurate but can give you a idea. Like for instance you may have a 1/4 tank left but the gauge will read empty.

  • @patriotone755
    @patriotone755 Před 2 lety +1

    Great install video. Where did you get the handle/wheel kit for your eu3000is? I need to purchase one.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      They are not cheap…
      amzn.to/3Bpqimz

    • @patriotone755
      @patriotone755 Před 2 lety +1

      @@johnnysweekends wow! they are expensive. Thank you for the suggestion and video.

  • @michaelgarrett8104
    @michaelgarrett8104 Před 11 měsíci

    Thank you, one quick question.... Would this work for wood gas ? From a gasifier system.

    • @johnnysweekends
      @johnnysweekends  Před 11 měsíci

      Honestly I dont know. It’s not designed for that.

  • @frrapp2366
    @frrapp2366 Před 11 dny

    something most people dont know is that propane burns dry they used to have to replace the valves in converted vehicles because the factory valves we not hardened i think pretty much all valves are hardened now, but if you start to have trouble (low compression) or have an older unit might check

    • @johnnysweekends
      @johnnysweekends  Před 10 dny +1

      I don’t think out door power equipment like lawn mower engines are going to have hardened valves. Maybe the newer dual fuel units but a true propane unit or NG with have better valves.

    • @frrapp2366
      @frrapp2366 Před 10 dny +1

      @@johnnysweekends i think with the advent of low lead fuels they had to go to a harder type valve but yes probably not like in a car , truck or gas tractor

  • @dontbanmebrodontbanme5403

    While this is an awesome video, one should point out that if you don't already have this generator, Duromax has their XP4500iH generator. As the name implies, it has 4,500 starting watts (1,500 more than the Honda) and 3,600 running watts (800 more than the Honda), runs on both gas and propane (I don't know anyone who hooks up a permanent gas line to a portable generator, but I guess some do), all for less than half the price. While everyone knows just how outstanding Honda generator engines are, the Duromax comes with a 3 year warranty. I guess my point is, if you don't already have the generator, you might want to consider the many dual fuel options out there.

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      Yes there many options out there now to get a dual fuel and much cheaper. Which I always recommend if you are going to buy a generator look into a dual for due to its many advantages.

    • @tomtee4442
      @tomtee4442 Před 11 měsíci

      ​@@johnnysweekendsI watched all the TV ads during your video to help you out. Every little bit helps.

    • @troy3456789
      @troy3456789 Před 10 měsíci +1

      I buy something like this based upon its country of origin: not from CCP

  • @6Sally5
    @6Sally5 Před 2 lety +3

    Great video! How long will a 20lb tank run? Of course, what you run in the trailer will be a variable .

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      So a 20lb tank is almost 5 gallons of usable fuel. The Honda 3000 has 3.4 gallon tank. And will run 20 hrs on 1/4 load according to specs. Which with the propane bottle holding about 4.5-4.7 usable gallons of fuel I would assume almost the same amount of time for that amount of propane or close.

    • @Bwanar1
      @Bwanar1 Před 2 lety +4

      @@johnnysweekends No...not pretty close. Depends what generator your running for actual time, but Propane is 27% less efficient than gasoline, so figure about 25% min. less time.

    • @leguirerj
      @leguirerj Před 2 lety +3

      Gasoline has 116000 btu's per gallon. Propane has 92500 btu's per gallon. You will have to consume the equivalent of 1.25 gallons of propane for every gallon of gasoline. The honda eu3000is has a 3.4 gallon tank, therefore you would need 4.26 gallons of propane to provide the equivalent amount of energy. Which is a little less of the 4.7 gallons in a full 20 lb tank of propane.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +2

      So then I was close enough for a guesstimate 😂👍🏼

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Thanks…👍🏼😀

  • @keithmanningbocodjkaraoke7259

    I need to do my older Honda EG 3500x for my gen needs do u know if that one will work on mineas well ?I have 10 gallon gas tank causei dont use the lil 2 gallon factory tank at all cause I'm in the woods .Looks great thanks for any help you can info me on .

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      I’m not a hundred percent sure if this kit will fit. But Honda did use the same carb for a lot of models. May have to call and double check

  • @4x4le
    @4x4le Před 2 lety +3

    Does this adjust the fueling level to demands, or does it just allow a set amount of gas through even when the demand is low?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      The load regulator does exactly that. Adjusts to the demand of the load while the load block is like a fuel adjustment screw to fine tune and then your good. 👍🏼

    • @MittyNuke1
      @MittyNuke1 Před 2 lety +1

      Like Johnny said that’s the exact purpose of this kit. Also this will shut down the gas flow when the generator shuts down which is very important. There are some videos on CZcams showing how you can run a generator by taking the gas line to your stove and manually dialing the air to fuel ratio. That works if the load is constant, but if you’re actually using the generator to power anything , the load is almost never constant, and also, the gas flow will not stop unless you manually shut it off in that case. That’s why a zero demand regulator like the one in this kit is very important.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Very and good point! With out a regulator you are letting gas virtually flow freely which is extremely dangerous for you and your neighbors. Unfortunately not everyone is safe and uses Good judgment.
      The cost for a kit is worth it verses a diy job that could kill you and others…

  • @slyerit
    @slyerit Před rokem +1

    Very nice
    Do that kit work on EU7000IS
    and what kit is it please
    Thank you

    • @johnnysweekends
      @johnnysweekends  Před rokem

      I haven’t done it on the 7000. Is yours fuel injection? Carb model will work.
      In the description should have all the parts.
      Let me know 👍🏼

  • @hokehinson5987
    @hokehinson5987 Před 2 lety +1

    Can you use gas in an emergency if you remove the tube from behind air box?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Gas can still be used in your generator. This only adds the ability to run the generator on propane or natural gas. So now you can run all three fuels when ever you choose.
      Obviously one at a time.

  • @n.b.p.davenport7066
    @n.b.p.davenport7066 Před 2 lety +1

    Any other settings for the Natural Gas?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      If you hook up NG you would adjust the load block to adjust fuel mixture. But I guess once set NG will run very similar to propane so no adjustment may be needed. Altitude could change things a little.

  • @manofmanyhats142
    @manofmanyhats142 Před 2 lety +2

    I've installed a few propane kits. I will not use another motor snorkel kit out of WV. Didn't fit motor snorkel rubbing the fuel bowl and had to remove then engine didn't want to run. Also down the road if the motor snorkel rubber piece falls in the engine it could damage and lock up the motor. Hutch mountain, synergy, century fuels and a few others have propane kits that are a lot better than the motor snorkel deal. And when I talked to motor snorkel they just wanted to sandwich out the motor snorkel with longer bolts. That's not good as small as these bolts are that are holding the air filter on and with time good chance to strip or break off even with loctite on bolts.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Interesting. I know this is a updated snorkel from years past but I don’t have any experience with those.
      Thanks for the feedback.

    • @chucknetzhammer9489
      @chucknetzhammer9489 Před 2 lety

      I just put one on a 3500 predator. it would only run 700 watts before stumbling on gasoline. the rubber snorkel looked like it covered holes on carb. took it off.......ran fine.

  • @bobbyb7127
    @bobbyb7127 Před 12 dny +1

    What's the thread sealer you are using? So much better the Teflon tape.

  • @ronsmith6233
    @ronsmith6233 Před 2 lety +3

    Interesting, would like to have seen it go back to gas after install. Can you switch between gas and propane on the fly?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +2

      Yup you can, tried it a couple times but I didn’t do it on the video, sorry. But yea nothing changed. Just turn on gas and pulled choke and go.
      Only thing is don’t slam or pull hard on the choke as you can feel the snorkel give a little resistance. So just pull easy and it fired right up. Obviously your generator should be in good running condition.
      But yea so far so good. Super easy and love the options. A little spendy for the kit I guess but it’s the safe way to do it and honestly it couldn’t be a easier install.
      Glad I had the opportunity to get one to try.
      👍🏼😀

    • @ronsmith6233
      @ronsmith6233 Před 2 lety +1

      @@johnnysweekends Thank for the feedback.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      👍🏼😀

  • @2000freefuel
    @2000freefuel Před 2 lety +2

    Is there a kit for a Harbor Freight 79cc engine? or perhaps those 35cc 4 stroke weed eater engines?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      You would have to call the company direct and they maybe able to help.

  • @TheDefenderSisu
    @TheDefenderSisu Před 2 lety +1

    John do you know of a propane kit for the champion 4650 remote start generator?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      I think they have a lot. It’s the same kit darn near, I think the snorkel mount may just be slightly different. I would contact them direct and ask. So many of these generators use the same carb and same mounting so I’m sure they have something.
      You just don’t want to use remote start and stop with propane. You want to shut it off at the bottle or where ever the source is.

  • @CHICAGODUMB
    @CHICAGODUMB Před rokem +1

    awesome video

  • @xyksnk2390
    @xyksnk2390 Před rokem +1

    I like this. The only thing of consern to me is gas leakage either through the intake air filter or the exhaust.
    In a scenario where the generator for some reason shuts off. Will the propane escape through the intake filter?
    Also, in a scenario where we have low load or varying load. Since the propane provides constant flow and gas pressure, will unburnt gas be pushed right out the exhaust?
    The generator will vary the gasoline consumption depending on the load. The modified system, I'm guessing from what I saw, doesn't. Gas leaks can be pretty dangerous specially around electric systems.
    Lastly, the plunger style bleeder could start to leak overtime.
    Overall I like this conversion. But understanding the risks and the system limitations is a must.

    • @johnnysweekends
      @johnnysweekends  Před rokem +2

      This type of regulator works more opposite. Flow from the bottle closes the diaphragm. Vacuum then opens it to allow flow of the propane. So when generator shuts off the flow stops.
      Now sure over some years that back primer button could possibly start to leak. But like anything prechecks should be done like most things once in a while. Hope this helps

  • @jenyooin
    @jenyooin Před 2 lety +2

    Would this work with a 2 stroke engine generator ?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Well yea but in all honesty no.
      The generator could burn the propane or even natural gas, but neither will have oil in the mixture. When you run the 2 stroke engine you have a premix fuel say 50:1 which lubricates the engine. Or fuel and oil are separate which then you would have oil injection.
      So the option would be to run a oil injection system which you would have to setup and find the right oil injection rate. Which all in all would be a cool project but a pain in the rear for the most part.
      So for a plug and play kit…. No unfortunately.
      Hope this helps….👍🏼

  • @bazza2825
    @bazza2825 Před 2 lety +1

    Nice one, so how does it work on NG connected to the house, also I have a Korean brand generator is the kit the same for most genies. cheers.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Yes the kit is mostly the same you just have to get the correct snorkel. That’s the only part that would be a little different. But a lot of gens runs very similar carbs and bolt patterns but still need to find the correct for your gen. You may have to email them.
      As for NG it’s almost identical to running propane only you get a little less btu’s so slightly less power. So the load block may have to be adjusted slightly different.

    • @Pk3_Garage
      @Pk3_Garage Před rokem +2

      This kit works great on NG. There is minimal power loss when running on NG, from my experience. The key is setting up the regulator on low, medium and large loads. The engine should be running smooth. (Use a wattage meter to see the hertz)
      Once it's set up, you will be fine and won't have to make any adjustments. Also, you have to have the correct size gas pipes and NG pressure and volume being delivered to the generator.

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      Yea I didn’t notice any loss on Lpg so that was nice. I would have thought a little on NG though.

  • @DM-fp8uw
    @DM-fp8uw Před rokem +1

    How do you switch from propane back to gasoline? What makes this kit different from those that only use one or the other?

    • @johnnysweekends
      @johnnysweekends  Před rokem

      On the generator turn fuel switch off and run till empty. Or open side panel and just use the drain screw. Then turn on propane.

  • @trustme7731
    @trustme7731 Před 2 lety

    Interesting but what made you think you made and installed that meter box cord correctly?

  • @bobbo1946
    @bobbo1946 Před 4 měsíci +1

    newbie w questions...are there any out of the box smaller, say 2500-3500 watt tri fuel inverter generators out there..just went thru an ice storm with a week of 0° wind chills and only relying on mr buddy heaters..it got old pretty fast..
    another question, how can you tell if the propane tank is old and purged of air?
    last question..some sites say that a 20lb propane won't vaporize enough in cold weather to run at higher loads..?? they suggest using 2 30lb tanks..??? thx for the video

    • @johnnysweekends
      @johnnysweekends  Před 4 měsíci

      Most times you wont see a NG generator that small since BTU output is so low. You would have a 2500 start 1800 run on gas, 1600ish on propane and NG would be like 1200 maybe. I would take the propane tank to a service center if it’s old and have inspected, and they can also answer the other question better. And yes smaller tanks can freeze the regulators quicker in cold temps. Normally from my reading a higher flow regulator is needed and say a 40lb tank.

  • @dedwin8930
    @dedwin8930 Před rokem +1

    Great video,well done! How about high elevation like 7,000 to 9,000 ft.? thanks from Dennis

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      It will also work at elevation to but really cold temps could cause some freezing issues.
      And thank you..😀👍🏼

    • @dedwin8930
      @dedwin8930 Před rokem +1

      @@johnnysweekends Thank you for your fast response!

    • @johnnysweekends
      @johnnysweekends  Před rokem

      👍🏼😀

  • @danielsmith2447
    @danielsmith2447 Před 2 lety +1

    I'm going to have to rewatch this and count how many times he said 'go ahead'

    • @Jack-ng1su
      @Jack-ng1su Před 2 lety +1

      He says "for the most part" about 84 times!

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Wow really ??? I though it was high 50s
      🤣🤣🤣👍🏼

  • @chesterfranklin2642
    @chesterfranklin2642 Před 2 lety +1

    Us Carbonation no longer shows a kit for the Honda EU-3000is on their web site. Also, on hold forever on the phone. The ease of the kit you have is what got my attention.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Interesting not sure why they would discontinue but maybe it’s just not listed.
      I don’t know keep trying I know tons of places are short staffed so maybe try again

    • @chesterfranklin2642
      @chesterfranklin2642 Před 2 lety +1

      @@johnnysweekends Finally got an email response from the company. The kit doesn't show up on their web site, but they claim to still sell it. Looks like I'll be buying one.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Oh nice…. Glad you got one..👍🏼

  • @cheaptick
    @cheaptick Před 10 měsíci +1

    I did this... The gen had problems starting and running. What nobody stressed is that the gas fuel requires a hotter spark and you may have to close down the spark gap. So that got it running on LP gas although it sputters on sudden load increases. Then I tried to run on NG and it is total crap. Now I have a high performance kart racing coil coming to see if I had a marginal ignition system. Also I have heard that these engines can have too tight of valve lash making the compression marginal. For me this hasn't been as easy as the videos.

    • @johnnysweekends
      @johnnysweekends  Před 10 měsíci

      Propane I didn’t have a issue. But yea close the gap if you need to and sometimes one hotter plug depending where you might be. I dont do NG much because I dont have outages for days on end.

    • @cheaptick
      @cheaptick Před 9 měsíci +1

      I just gapped the standard plug down to .018" and on LP found it now will pick up a sudden load from no load nicely. Even ECO mode. I have a hot coil and plug for when I resume testing with NG.

    • @johnnysweekends
      @johnnysweekends  Před 9 měsíci

      @cheaptick yes a tighter gap for propane helps 👍🏼

  • @dedwin8930
    @dedwin8930 Před 9 dny

    Can you shut off using only the key? Or do you have to turn off propne tank valve? Thanks

    • @johnnysweekends
      @johnnysweekends  Před 9 dny

      Yes key but only if you plan to use it again later. If not running For the rest of the day shut it off at the tank first. Then key.

  • @thomasmiller2089
    @thomasmiller2089 Před 2 lety +1

    Do you mind sharing what wheel kit you have for your EU3000 please?

  • @jr-pl9kj
    @jr-pl9kj Před rokem +1

    a choke is used as a way so suck more liquid fuel (gasoline) out of a carburetor from low engine vacuum and is not required for gaseous fuels.

  • @n.b.p.davenport7066
    @n.b.p.davenport7066 Před 2 lety +1

    I haven't seen a choke on a small engine and years, the older stuff yes it's the newer stuff

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Yea depends on brand and model. Honda still uses a choke 👍🏼

  • @Veritas-invenitur
    @Veritas-invenitur Před 2 lety +1

    My sister bought an old house last year. For Christmas, my parents and I are buying her a Generac 5500E and having a transfer pannel installed. Since all her yard equipment is battery powered I am concerned about the gasoline situation. I am considering doing a trifuel conversion on the generator to prevent future problems. What does everyone think?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Is just really adds options and if the carburetor gums over basically a jet gets plugged the propane snorkel still works. Propane stores allot longer and normally has less running issues. Only thing is you burn more propane because it’s not as efficient. Again the options are nice to have.

    • @Veritas-invenitur
      @Veritas-invenitur Před 2 lety +1

      @@johnnysweekends Ultimately, I am worried about bad gas. She doesn't use gasoline, so I'm thinking that it wouldn't be unrealistic to have a situation where the power goes out and the gas she has at the house or in the tank is 2 years old. Atleast with propane that is not much of a problem. Another thing is that she does have natural gas going to her garage. It might be worth having a quick connect hookup Installed. That way she never has to worry about fuel. Ultimately, she lives near downtown, the power might go out once every couple of years. The problem is that her basement has a parameter drain with a subpump pit. If those pumps loose power her basement will flood.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Yea the propane or NG seems like a better way to go. I also recommend it for people who only have there power go out once in a while and have that available at there home. Or just grab a 5g bottle or two.
      All depends what they wanna run.

  • @irokpe6977
    @irokpe6977 Před rokem

    Perhaps, the feul regulator is too open? You could have tried tightening it a little to see when the gen set will stop producing full power. This process might help you save some gas.

    • @johnnysweekends
      @johnnysweekends  Před rokem +1

      You don’t want to run the unit to lean or could burn up so a little extra is better then not enough.

  • @angelresto2567
    @angelresto2567 Před 2 lety +1

    Nice jod.

  • @leguirerj
    @leguirerj Před 2 lety +1

    Was your EU3000is out of warranty at the time you did this? I installed the Hutch Mountain propane kit, mine is still in warranty. I violated mine. it's been two years. I can get rated running watts on both propane and natural gas.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      This one is 4 years old I think so yes.
      I don’t think is should void warranty from what the instructions say but that may be of a dealer installs it.
      But yes I was getting full power as well. Plus just smells nicer. Although you will burn more fuel over all. But the options are nice.

  • @craigcook1571
    @craigcook1571 Před 2 lety +1

    Will the conversion work with fuel injected generators?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Maybe, I’m sure there could be a way to make it work. You should call the company directly and ask.

  • @timbeach2409
    @timbeach2409 Před 2 lety +1

    How long does a full propane tank last compared to a full tank of gas ?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      The Honda tank is 3.4 gallons and will run 20 hrs at 1/4 load. A 20lb or 5 gallon propane bottle holds about 4.7 gallons of usable fuel. The run time is almost the same for both. I think the propane last a extra 30 minutes but you are using more fuel over all.

  • @bertkelly7650
    @bertkelly7650 Před 2 lety +2

    Nice, but can you go back to gas w/o changing what you did for propane?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Yes !!!! Just switch the gas valve back on and fire it up..👍🏼
      Already did it a few times to check.

    • @bertkelly7650
      @bertkelly7650 Před 2 lety +1

      @@johnnysweekends Cool. Conversion kit is almost as much as what I spent for my 3500 Champion tho.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      $189?

    • @bertkelly7650
      @bertkelly7650 Před 2 lety +1

      @@johnnysweekends $325 New.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      Got ya. Just don’t do the diy home valve thing with no regulator. Those are the people you see dead on the news.

  • @mafosa8519
    @mafosa8519 Před 2 lety +1

    yup.. hz n volts where dead on!..
    great share!
    larry

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Thank you, and thanks again for watching 👍🏼😀

  • @carlpettit1567
    @carlpettit1567 Před rokem +1

    "For the most part!"

  • @LORFCASTER
    @LORFCASTER Před 2 lety +1

    Is the same amount of propane flowing out of the tank regardless of engine RPM ? If yes, is this ok ? Does the engine run rich at low RPM and lean at high RPM ? Maybe im not understanding something but it seems like there is no physical connection between any fuel regulators and the actual generator. Just that bolt that got 5 or 6 turns.
    Also, that fuel supply snorkel that went behind the airbox looks like thin / unprotected material that could easily get a hole vibrated into it over time.

    • @johnnysweekends
      @johnnysweekends  Před 2 lety +1

      There are two regulators. One on the tank, and the load regulator on the generator. The load generator has a diaphragm in it to open and close a valve to allow for more gas flow. Then it goes past the load block…. Which is the bolt you turn which acts kinda like a jet for fine tuning.
      So yes it is fully regulated verses some diy tricks that can and will possibly kill you.

  • @InfantryGeek
    @InfantryGeek Před 2 lety +1

    So this device will work with any generator or are their different parts that i need for my generator?

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      Will work on most any small one yes. But you wanna buy a kit that will work with your specific generator. Go online to USsnorkel.com and they have a lot of kits. If you don’t see what ya need email or call them.

  • @CaryOutArk
    @CaryOutArk Před 4 měsíci

    could this be used on a smaller Honda gx35 engine? For a bushtrimmer

    • @johnnysweekends
      @johnnysweekends  Před 4 měsíci

      I don’t think it would have any power. The btu amount for NG is already so bad. That would have no power. Especially at elevation

  • @timothyjalbert9253
    @timothyjalbert9253 Před 2 lety +1

    If this is natural gas or propane how is this 3 type of file if you are removing the carburetor for regular gas

    • @johnnysweekends
      @johnnysweekends  Před 2 lety

      You are not removing the carb. It stays in place. You add a additional piece. This allows you to run 3 types of fuel.
      👍🏼😀