How Power plant Safe shutdown carried out

Sdílet
Vložit
  • čas přidán 20. 08. 2024
  • How Power plant Safe shutdown carried out
    SADC control
    Boiler windbox DP
    • Actions after Boiler t...
    • Boiler follow mode in ...
    • Hydrogen (H2) filling ...
    • How Boiler PA Fan & FD...
    / @kpatelbla
    SADC control & Flame stability
    SADC modulating
    • Stalling of Primary ai...
    • Boiler follow mode in ...
    @Power Plant discussion
    @Power Plant guide
    Planned shutdown safety
    Safety during shutdown
    Power Plant practical knowledge
    • How much air needs for...
    -HUrFuRJ1Hd
    • Boiler SADC control in...
    Power Plant technical pratyush
    / @kpatelbla
    ‪@PowerPlantDiscussion‬

Komentáře • 11

  • @worldinstrumentationengineer

    बहुत अच्छा गुरू जी प्रणाम 🙏🙏

  • @akashpatel1547
    @akashpatel1547 Před 8 měsíci +1

    Great explanation..... thank you sir

  • @motive0507
    @motive0507 Před 7 měsíci

    Could you please make a video on the display board of DC,SG,AGC,AG/SG,instantaneous,Average frequency etc.... which is displaying on a screen(about all the things displaying on the screen) in control rooms of power plants.
    It is helpful to lots of people

  • @ashutoshkumarpandey3099
    @ashutoshkumarpandey3099 Před 6 měsíci +1

    Sir, Shutdown ke time me BCP kab start karenge....

    • @kpatelbla
      @kpatelbla  Před 6 měsíci

      For which unit asking about means 660 MW or 600 MW, for both it is different?

    • @ashutoshkumarpandey3099
      @ashutoshkumarpandey3099 Před 6 měsíci +1

      660 MW

    • @kpatelbla
      @kpatelbla  Před 6 měsíci +1

      During shutdown when wet mode activated and levelling vessel level showing more than 4500mm.

  • @motive0507
    @motive0507 Před 8 měsíci +1

    Could you please tell me about
    mechanical over speed trip at 112% of 3000rpm means 3360rpm
    Electrical overspeed trip at 110% of 3000rpm means at 3300rpm

    • @kpatelbla
      @kpatelbla  Před 8 měsíci +1

      It is given because of safety it over speed of turbine occurred so first Electrical over speed occurred by means of remote trip solonoid of governing system if it fails to operate the final one is mechanical over speed by means of spring force which extend the fly bolt outward by centrifugal force consequently hit the pawl and drain Aux trip oil of mechanical trip device.

  • @motive0507
    @motive0507 Před 8 měsíci +1

    Could you please tell me that why spiral water walls are used in super critical boiler(from bottom ring header to intermediate header)

    • @kpatelbla
      @kpatelbla  Před 8 měsíci

      It is provided to enhance flow and avoid film boiling.