  • Hi friends today I am going to show Automatic Water level Controller for your water tank at home .
    It is very easy to make and low costing You can control up to 1hp motor by it.
    Thank you for watching .
  • Věda a technologie

Komentáře • 188

  • @jagrutbhatt3301
    @jagrutbhatt3301 Před 3 lety +3

    Useful project in a simple way.

  • @yashdahibhate7517
    @yashdahibhate7517 Před 5 měsíci +3

    Very amazing bro i try this.. 100% worked.. 💯🔥👌🏻

  • @jpscafe7648
    @jpscafe7648 Před 3 lety

    Mas o projeto é show de bola!

  • @mofa3754
    @mofa3754 Před 4 lety

    Wonderful!

  • @kishorekumarrrrrrrrrrrrrrrr

    I made the exact circuit works very accurate thanks for the circuit

  • @biproantukabiraj6226
    @biproantukabiraj6226 Před 4 lety

    Fantastic idea

  • @isaacsmandigo9179
    @isaacsmandigo9179 Před 3 lety +2

    Interesting circuit system. Can please do one that pumps water out when the tank is full please

  • @ejtrejos
    @ejtrejos Před 4 lety +9

    A greeting from Mexico. Thank you for your contribution to knowledge. It would be good to make a video where you indicate the control of the tank. This is to prevent the bomb from burning. In other words, to protect the pump in the absence of water. (empty tank). Thank you very much.
    When the tank runs out of water, the pump will not activate by asking for water (pump protection).

    • @carloscesarTHEBEST
      @carloscesarTHEBEST Před 3 lety

      Excelente ideia. Otima sujestão.

    • @gopalshekar986
      @gopalshekar986 Před 11 dny

      Great point! Greetings from India. We do have level controllers that detect dry run of the pump; that is, after several seconds of start up of pump, if there is no water flow at the outlet, there would be an alarm and the motor is turned off. We then have to manually inspect and resolve the issue.
      We could add more sensing too - motor temperature, abnormally long run (due to water being continually emptied) etc.!

  • @satishyadav-rv9iz
    @satishyadav-rv9iz Před 4 lety +6

    Can u tell where to fix led for low medium and full connection

  • @kanikasvlog
    @kanikasvlog Před 4 lety +1

    Very usefull for practical life... 😮

  • @pssuresh1
    @pssuresh1 Před 4 lety +1

    Good work, please tell 5v supply circuit ,cable maximum length ,can add water level indicator to this circuit.

  • @diyexplorer8728
    @diyexplorer8728 Před 4 lety +3

    Good one! I can use this on my water tank.

  • @joserivas7251
    @joserivas7251 Před 3 lety

    Hola disculpa esa corriente que pasa por el agua afecta al cuerpo humano ? en caso que se conecte a un tanque de agua para baño ?

  • @javierrd7818
    @javierrd7818 Před 4 lety +1

    Excelente.Favor el plano del Circuito

  • @Lovetolivetruely
    @Lovetolivetruely Před 4 lety

    How can I make this for one way with a sensor or a switch?
    Maybe you can help me with what I'm looking for. I'm buying a 129v electric water dispenser. However it doesn't come with and automatic shut off valve. I am hoping to find something automatic that has an automatic switch or sensor that will allow the water to pump and stop. Kind of like how alarm system sensors or a type of toggle that when something is moved or a door is opened it activates.
    I hope I'm clear...
    Would you happen to know what I could buy that would do that that I could connect to the water dispenser and have it automatically activate and deactivate?
    I'm open to suggestions. Also must be a very small application that I can mount to a wall or pole or rod... Thank you and anyone who can help.

  • @vijayendirangiridharan6113

    Can this system work on 5 volts?

  • @sujitmazumder1255
    @sujitmazumder1255 Před 2 lety

    Thank you very much for uploading this circuit! I have tried your circuit, unfortunately when the tank is full, circuit doesn't cut off the power, hence the relay being on! All the parts were checked and they are found ok.
    Please give me way how to overcome this problem. Thank you.

  • @jadielmonja9385
    @jadielmonja9385 Před 4 lety

    Excelente

  • @drv.ramanathannadella561

    Super. Simple and best. Where can we get the kit?

  • @virusdetected4539
    @virusdetected4539 Před 3 lety

    Good one but if i use long wire around 15 m it's not working.
    Can u help me out?

  • @vigneshm348
    @vigneshm348 Před 3 lety +2

    can i use 12 volt 1 amp adapter?

  • @NarinderSingh-ys9qz
    @NarinderSingh-ys9qz Před 4 lety

    Is work for top water tank
    Tank on 3rd floor is it work

  • @rahulkrishnantr5345
    @rahulkrishnantr5345 Před 2 lety +1

    220 v comea as output so how you used small water pump? Please replay its for a project

  • @shylendranponnani
    @shylendranponnani Před 2 lety

    Haii hello ican help you? How built in 24volt adaptor usage to automatical waterlevel control

  • @shamzaarvideos8750
    @shamzaarvideos8750 Před 4 lety

    hai sir, 1m resistance kithina wats 1k resistance kithina wats pls bathaya...

  • @bhasvataprajapati2449
    @bhasvataprajapati2449 Před 4 lety

    Good Very good

  • @yuvrajparge9769
    @yuvrajparge9769 Před 3 lety

    Sir can you tell me which motor yiu have used?

  • @Educare94
    @Educare94 Před 4 lety +4

    Please draw the DC connection on relay

  • @aualtinarama3262
    @aualtinarama3262 Před 4 lety +2

    hello is it possible to do the opposite of this circuit?
    So when the tank's full, the engine's going to work, and it's empty.

    • @ji8in
      @ji8in Před 4 lety

      Ofcourse .... Connect the motor to the normally closed pin of the relay. Thus when the tank is full the pump will start working... When the water level drops below the threshold level it stops

  • @piotrwilk8772
    @piotrwilk8772 Před 4 lety +1

    I would like the pump to turn off in the LOW position and turn on in the HIGH position. Is it enough to swap the relay contacts?

  • @rajkumartamang6462
    @rajkumartamang6462 Před 3 lety

    What is the specification of dc adapter you use

  • @shinchan2934
    @shinchan2934 Před 4 lety

    Is there current flowing in bucket ???

  • @johanrynjah8241
    @johanrynjah8241 Před 4 lety +1

    Using relays with bigger amperes , this design can be used for bigger or heavy duty AC water pumps. .

  • @michaeldominiccruz8678
    @michaeldominiccruz8678 Před 4 lety +2

    Can I use 9v battery instead of 220v, for a 12vpump?

  • @raimundoporesrgp3698
    @raimundoporesrgp3698 Před 3 lety

    Sr i can't get the resistor 1m so how can i change that resistor pliss🙏

  • @technicaliticlass1597
    @technicaliticlass1597 Před 4 lety

    Sir rely contion

  • @anandhavignesh1578
    @anandhavignesh1578 Před 4 lety

    Whats that yellow and red wires are for? Kindly answer.....

  • @nileshsutar9020
    @nileshsutar9020 Před 2 lety

    Can use any IC other than 555IC

  • @vinaykale9262
    @vinaykale9262 Před 2 lety

    can some give the name which equipment used in this??

  • @mohamedabrar7868
    @mohamedabrar7868 Před 4 lety

    what is that sensor wire. please send the name of that wire and photo

  • @RuralFoodsLifestyle
    @RuralFoodsLifestyle Před 4 lety

    Great video!

  • @RohitGupta-wv5ct
    @RohitGupta-wv5ct Před 4 lety +1

    How to eliminate problem of electrolytic corrosion of sensor wires

  • @user-ph7ju4tt8s
    @user-ph7ju4tt8s Před 3 lety

    جميل جدا

  • @anikbanerjee1531
    @anikbanerjee1531 Před 4 lety +1

    I can use the battery of 12 volt please give me the diagram of the circuit minus plus

  • @RK_Patnaik
    @RK_Patnaik Před 2 lety

    Is it shock proof , shock neni lagega ya lagega

  • @raimundoporesrgp3698
    @raimundoporesrgp3698 Před 4 lety

    Can i use motor listrik i didn't see it thas why i still confuse

  • @doobuu2999
    @doobuu2999 Před rokem

    I bought bc548 instead of 547 and dont have enough time to change it. Can you suggest any alternatives to make it work?

  • @dhirenpasman4936
    @dhirenpasman4936 Před 3 lety

    Power Supply kitna volt diye ho?

  • @Hrithikdas999
    @Hrithikdas999 Před 2 lety +2

    I've made this with 230v ac pump but can this circuit work on 12v dc pump

    • @rajasidhu268
      @rajasidhu268 Před rokem

      you can use 12v relay and control any 220 device

  • @GULSHANKUMAR-ox6rm
    @GULSHANKUMAR-ox6rm Před rokem

    agar auto start na lagaye only Off lagaye to chalegaa?

  • @anikbanerjee1531
    @anikbanerjee1531 Před 4 lety

    Bhi ham esh mein Kitna w or Kitna ampere ka supply de

  • @GULSHANKUMAR-ox6rm
    @GULSHANKUMAR-ox6rm Před 4 měsíci

    Can i use this for auto Off Only ....
    i do not want this to turn ON automatically

  • @acevikki
    @acevikki Před 4 lety +1

    Sir pura circuit bataiye na kis kis jagah connection Kiye Hai

  • @irfanshafiq1353
    @irfanshafiq1353 Před 4 lety

    Bro kia ye revers me kam krega mtlab k me chahta balti se pani full hote e pump use khali krde?

    • @sanjoymondal1658
      @sanjoymondal1658 Před 4 lety

      Yes..
      Motor ka power supply NC( normaly close) pe connection kar dije relly pe..

  • @user-xj1tc8id1r
    @user-xj1tc8id1r Před 8 měsíci

    I made the circuit. But when the motor starts the base register of bc547 and 555 ic gets very hot. What to do ?????

  • @simranmoraes3260
    @simranmoraes3260 Před 20 dny

    It’s working very fine I liked but can you do other way around motor stays off and when reaches high it turns on and off when reaches low point please 🙏

  • @thereeler3633
    @thereeler3633 Před 3 lety

    Nice, #ENGINEERBACCHA

  • @ManishPrajapati-zm2cs

    Bhai iss project me banane ke liye iska equipments kha pe milega or motor kon sa hai

  • @ntpawar1982
    @ntpawar1982 Před 4 lety

    Dear sir please that how to 1 hp sumrsible pump with stater conection

  • @timkishelov9489
    @timkishelov9489 Před 3 lety

    Two level switches and a relay will do the pump automation.

  • @siri77954
    @siri77954 Před 4 lety +1

    Sir i have open well in my farm field that well will fill once in a 2/3 day's and it is far away from home and i want to wait for power supply (supply provided by electricity board in shift wise)it's difficult to go and come plz kindly give modified circuit for operating irrigation pump when well is full and off when well getting empty .sir i am waiting for you replay kindly help to this former.

    • @embeededtinker7005
      @embeededtinker7005 Před 4 lety

      Srikantha M.B , I've a solution for you problem...!
      whatsapp me @ 9989800949

  • @GULSHANKUMAR-ox6rm
    @GULSHANKUMAR-ox6rm Před 9 měsíci

    Will it work With 1000 litre Tank and A Submersible Motor ?

  • @laurenceblaurence9972
    @laurenceblaurence9972 Před 9 měsíci

    Hey! Sorry tell me the name of that black devices.

  • @shivalikenviro7207
    @shivalikenviro7207 Před 3 lety

    Hi, if I want to purchase this circuit, what will be cost???

  • @anandhavignesh1578
    @anandhavignesh1578 Před 4 lety

    My circuit is not switching off....its continuously in on state...pls help

  • @MAKERWORLD14407
    @MAKERWORLD14407 Před 9 měsíci

    May i use 5 volt realy

  • @rakesh4188
    @rakesh4188 Před 3 lety

    Can you please tell the components name

  • @anikbanerjee1531
    @anikbanerjee1531 Před 4 lety

    I can use battery of 12 volt

  • @rajdeepbarman7861
    @rajdeepbarman7861 Před 4 lety

    Sir mera Tanki Motor se 12-13 meter dur hai, motor automatic off hone ke 20 minute bad firse automatic on ho raha hai. Aisa continue hota ja raha hai. Please help me!

  • @pvkexperiments.4476
    @pvkexperiments.4476 Před 8 měsíci

    What is the adapter rating is 500milli amps or 1 amps
    Because i tried this with 500 milli amps it works but in 1 a it wont work

  • @Raj-pk4ey
    @Raj-pk4ey Před rokem

    How can I use this for 1HP motor ?

  • @BandaMethoDBR
    @BandaMethoDBR Před 4 lety

    this can be upgraded for a small house pump?

  • @subashj5089
    @subashj5089 Před 3 lety

    But good

  • @vennela27c.8th4
    @vennela27c.8th4 Před 3 lety +1

    Can u plz say how much does it cost?

  • @bobbysingh7799
    @bobbysingh7799 Před 2 lety

    Sir mene yes project work tyar karna hai

  • @NorthZoneEdits
    @NorthZoneEdits Před 9 měsíci

    Can we use 9v instead of 220v ac for 6v pump

  • @LAMPUDPN
    @LAMPUDPN Před 4 lety

    Can i use other transistor besides bc 547

  • @faizanbukhari9334
    @faizanbukhari9334 Před 4 lety +1

    I want to run 220v motor through it how can i do that?

  • @mohanrajselvaraj4831
    @mohanrajselvaraj4831 Před 3 lety

    Wat if lower tank has no water

  • @laurenceblaurence9972
    @laurenceblaurence9972 Před 9 měsíci

    Sorry,tell me the name of that black devices.

  • @sudheertantapureddy6827
    @sudheertantapureddy6827 Před 4 lety +1

    Sir , can I use diode in4004 instead of in4007 please relay me fast

  • @sandipoob3610
    @sandipoob3610 Před 3 lety

    project to accha he lekin isme ak dikkat he..ye to only uppar ki tank ka project he agar iske sath under ground tank ka system hota to or bhi accha ho jata..or isme agar full tank hone par buzzer add hota ho to vo bhi kar dena....
    try to upgrade your system with second under ground tank ...

  • @Sri20.96
    @Sri20.96 Před 3 lety

    2hp moter also same circuit working

  • @padmarekha9572
    @padmarekha9572 Před 2 lety

    Sir I am doing project
    My project name is water level controller by using pic micro controller
    In our project we use two pics sir
    First pic is 16F54
    Second pic is 12C508
    The first pic is giving connection between sump tank and water tank.(overhead tank)
    The second pic is only used in overhead tank
    I want circuit diagram for both pics and also I want code .

  • @indiangmv3180
    @indiangmv3180 Před 2 lety +1

    What is voltage rating of the water pump?? that you are using

  • @dhruviachaudhari875
    @dhruviachaudhari875 Před rokem

    full of details this model like cost, components, minimum & maximum price etc.

  • @sasthamoorthi-gt1id
    @sasthamoorthi-gt1id Před rokem

    Bro work aagala bro 12 volt supply poga kooda mattukkudhu

  • @rjgalz8043
    @rjgalz8043 Před 2 lety

    Do yo have Arduino code for this?

  • @ninyomansuhargayasih1458

    Sensor ke kaki no 6 IC tdk bekerja,apa yg salah?

  • @tejaskansara2276
    @tejaskansara2276 Před 4 lety

    Ye dc motor keliye hai ?

    • @creativeetc
      @creativeetc  Před 4 lety +1

      the circuit is a switch , you can use it for both dc and ac motor

    • @ajayyadav3602
      @ajayyadav3602 Před 4 lety +2

      electrolysis will take place,
      is there any way to prevent it??

  • @JigneshPatel-jc6ki
    @JigneshPatel-jc6ki Před 4 lety

    upar ki tanki me bich ka wire he voh pani me rhetahe jab pani voh wire se niche jatahe tab moter start hotihe jab pani bich vala wire ko tuch hotahe to moter off hojani chaiye parantu kyu nahi hotti????.

  • @sudheertantapureddy6827

    It worked but my ic is burning always

  • @sandeepvishwakarma4177

    Good sir

  • @mamidivasudev5988
    @mamidivasudev5988 Před 3 lety +1

    Sir the ic used in this circuit is
    NE555 or any other ic sir and the relay is 12v how many amps we use sir ?? Please reply

    • @NarinderSingh-ys9qz
      @NarinderSingh-ys9qz Před 3 lety

      I am using circuit is good for upper tank now it is requested to give circuit for lower tank such as upper tank working is good i used bigger relay instead of small working is good

  • @ridabest5426
    @ridabest5426 Před 2 měsíci

    Hello, I tried but it didn't work. I used exactly the same components except that the water pump on my side is 220v

  • @mayurkhan7.8.6
    @mayurkhan7.8.6 Před 3 lety +1

    Sir mujhe es project ki pdf file chahiye thi plz aap avelable krwa do

  • @luqmanmpm
    @luqmanmpm Před 2 měsíci

    It turns off automatically but does not turn on automatically what was the reason

  • @KrishnaKulal-lj5vt
    @KrishnaKulal-lj5vt Před 24 dny

    Bro I did this but relay bar bar fuse ho raha he heat hoke melt ho raha he kya kare😢

  • @sairamtechtelugu6744
    @sairamtechtelugu6744 Před 4 lety

    Bro Circuit board Diagram kavali broo

  • @danielferrari1141
    @danielferrari1141 Před rokem

    fantastic