How to install and plumb bath tub waste with overflow taps and bath trap
Vložit
- čas přidán 3. 03. 2018
- Hi a Big Thanks for watching my channel and likes . In this video I'm showing how to install bath tub including plumbing waste with overflow fitting taps , bath trap and sealing gap between bath and a wall. For taps to mains connection I'm using flexi hose 3/4 to compression joint 15mm pipe, shallow bath trap that fits 40mm solvent waste pipe
- Jak na to + styl
This was great. Explained very clearly and very good camera angles to understand the process. Thank you!
Thank you, used this video to replace a leaking P trap, I was having trouble with the replacement not attaching correctly, your video showed the correct ends for the different rubber seals.
Thanks buddy, just sitting in the front room and drip drip drip. bath tap trap seal broke . saw halfway in your vid how easy it is to install £3.99 later all sorted . thanks.
good job..tq for the tips..
Another great video!👍
Good video and demonstration!!
i took my bath trap of to clean it as it was clogged up after some diy and when i put it back on it leaked in 3 places it has 2 connector tubes NIGHTMARE. After watching this video i realised i put the black rubber rings in the wrong place After some patience and a sore hands its fixed whithout this video i would have had to call a plumber im so very thankful
Another good Vid, your on a role.
Well done!!! Thank you!!!
Put a big thick line of silicon along the outside edge or the bath 'before you push it against the wall, then you'll have two layers of water protection
Thanks for the video 👍👍
loved the video.
Very informative video as most of yours are.
~Thanks; your video was very clear and helpful.
Great video. I've followed all your instructions and all is fine, except one of the plastic pipes underneath has a little leak at the join. Should I put plumbers putty inside or around the outside of the plastic pipe to seal it? Thank you.
Nice job mate
Tanx plz keep uploading videos 👍
great video and really helpful. thanks
Got a small bathroom I'm doing can I fit the bath level it then tile bath upwards .
I love this video thanx for sharing yr work . But how i chang my old tap please and from wher i can close th water befor i work
nice work
Very informative video and great explanation
Very informative video, thank you. One thing is that the wall looked likely to allow your silicone seal to fail because its adherence is best on non-porous surface.
Maybe install tiles below below rim line before fixing bath?
Johnny Wilkinson I’m assuming it will be tiled over and sealed once more between tile and bath
Helpful video thank you
Weldone.....
Very good, keep the good work/video's..
Hi I have an identical bath with the same fittings for the leg supports. The bracket and the bolt that goes on first, it says from my diagram that you pull the bolt up to raise the leg. Or do you pull the bolt, to the right and then to the left to get the bracket in the upright lock position.
Bath needs to be fitted on barrears. Battens across lenght and width on the wall to stop moviment breaking your silicone beads, no matter how many you put. People step on the edges to wipe the Tiles!. It also needs full tanking before tiling to stop condensation damage entering the substructure or in this case the brickwall. Enjoyed the video anyway!
Thank you! xxx
it's a very useful video
Very nice bro thank u
Do I need to hook up the overflow?.im putting a tub in my cabin and will be using a bucket of water @ a time to bathe and a bag shower to shower...I have a vent about 4 feet ahead of the tub...thanks
I have a lot thank you
Supper
Great thanks for the video excellent.
I am tiling my bathroom floor, I wondered if its better to tile underneath the bath or is it not necessary?
Thanks.
for future reference it is not necessary to do this. fit the bath before tiling and tile to the bath x
@@OllieCraigBloxham you would get a better seal if you push the bath upto the tiles, rather than tile onto the bath.
great video bro. i have a question, 6:52 can you connect this to a metal waste pipe ? thanks for your vids !
I like the silicon behind the tiles. Would you ever get any mould issues though? Thanks
yes. even the mould resistant silicones are useless if there is no proper ventilation in a bathroom.
Hi mate. Theoretically if the overflow pipe fell off the fitting at the top of the bath because it wasn't connected securely and its now laying on the floor. Could emptying a full bath of water down the waste hole and filling the pipes cause a lot of the bath water to leak out of the overflow pipe that is no longer connected to the bath and soak the floor?
Thank you.
You reduced 22mm bath taps flexes to 15mm,
Is that no going to affect the water pressure especially if you have loft water tank ?
Like like 👍
no waterproof plasterboard installed?
Bathatap Kasa fiting Karaycha te shiklo... Outlet 1 1/2..pvc pipe.. Hot and cold weather inlet outlet... Bandhakam... Hight...... Etc....
Where can I purchase a tub similar to this one in the video? I'm located in N.W. Indiana. My sewer piping is not accessible from below so being able to make the connections from the side of the tub would be helpful.
Uk
Hi i was told by a plumber you should apply silicon to the bath waste washers to get a good seal otherwise after some time water will seep through is this true in your experience?
The only washer that I apply silicone on is a basin waste rubber washer , 50% are leaking between washer and a tread no matter how strong you tight it
Hej. Mam pytanko. Czy te dziury w wannie na oddzielne krany nadają się również do instalacji bath Shower Mixer? tzn nie wiem czy te odległości między nimi są uniwersalne również do wymianki na pojedynczy kran z prysznicem. Dzięki. pozdro
tak. one glownie sa pod mixer a jak ktos chce osobno ciepla zimna to instaluje kurki
How2D2 Dzięki za szybką odpowiedź. P.S. super kanał. Oglądam regularnie. pozdro
why did you change the bath trap and fit a different one that didn't have the inspection hole?
You noticed it ! the first one was faulty, couldnt tight it properly.
For a bath, should it not be 22 mm pipe for speed of fill?
Yeah and there should be brackets on the side fixed to the wall silicone is no good right angle tile trim should be used under the tile with silicone
Those white washers go in between the bath and taps. That’s why they’re white. Should have black ones underneath.
Am sure the washer should go at the top not the bottom
You don’t use wood battens to support the bath . I was told to give the bath stability.
I use wooden battens for plastic bath tubs but not for metal
How much does a plumber charge for fitting a bath?
I got quoted £300-£400 just to install a toilet & told me it would take half a day, little did the plumber know my brother is actually a plumber & installs bathrooms for a living unfortunately he was just way to busy to install ours as he's self employed. Some plumbers can really take the Mick out of people.
Why didn't he use PTFE tape on those bath fittings?
You don't need it, the rubber seal does the sealing not ptfe. You only need ptfe when you have no other sealing method (e.g. radiator tails)
Nice vids .... but pipes for bath should be 22. 15mm is bad practice.
Not if fed from a combination boiler. In fact it is advisable to use 15mm
Who can teach me i am 18 years old i am in a professional school and this is my job but i dont know so much so ho can teach me
Your waste pipe is going uphill lol 🤣😂 that won’t drain properly,also your supposed to fill the bath with water before you silicone,then empty once it’s cured.
The steel bath, taps & overflow waste looks very cheap quality!
I think I would buy slightly better quality, Ideal Standard acrylic bath with mixer taps & metal overflow waste.
Those white things are 'tap cushions' which should be above the bath, the black rubber, or nylon washers that should be below are missing.☺
Yee Ha! Where are we tying our horses? 😂
I don't believe in taro waste you didn't use any PTFE or cord ...always leak when is water stop run ...you should leave birdie longer when you stop water :)
Rough
UPPSC. Point and stop UPPSC point and connection and drank UBC track
You are def not a plumber
Worst job ever lol it’s slanting to the opposite way
thats is terrible terrible plumbing, oh dear! which is why I wont hire anyone else to fit my bespoke bathrooms