Anode Rod Replacement on a Bradford White Water Heater - Water Heaters Now

Sdílet
Vložit
  • čas přidán 29. 09. 2020
  • How to change an anode rod on a Bradford White water heater.
    For more information on repairing or replacing your water heater, check out our blog post here:
    www.waterheatersnow.com/blog/...
  • Jak na to + styl

Komentáře • 174

  • @JnrInd
    @JnrInd Před 8 měsíci +25

    Finally a video showing the anode rod on the hot water line. I must have watched 100 videos of anode rod replacements trying to find one with it in the hot water line. So thank you!

  • @johngori6518
    @johngori6518 Před 3 lety +95

    I think this might have missed a few key points - securing the cold water supply (you can see he did it because the ball valve is off at the start of the video, but it wasn't mentioned). Shouldn't you also move the gas reg valve to either "low" or "pilot" setting so it doesn't try to heat the tank while you are working, and then release the pressure on the tank before breaking the hot water union?

    • @eegg6954
      @eegg6954 Před rokem +10

      If you need someone to show you this you shouldn't be permitted to own tools.

    • @subinct
      @subinct Před rokem +31

      @John Gori
      Very Good Point, to people who searched anode rod and found this video.
      The reason he didn't mention it is because this Video is a second part of a two part Annual Water Tank Maintenance. In the first part, where he flushes the tank, he does mention all of this. A quick summary of the previous video would be nice next time.

    • @Lyod13
      @Lyod13 Před rokem

      ​@@eegg6954 stfu gatekeeper

    • @WillDesigned
      @WillDesigned Před 10 měsíci +3

      Yes he should of mentioned that you should turn the water heater off so you don’t burn up the heating elements. But as far as turning off cold feed/partially draining hot side if needed, if you don’t realize that then you probably shouldn’t be working on your water heater & should just call a plumber. Lol

    • @woodstream6137
      @woodstream6137 Před 8 měsíci +32

      ​@@WillDesignedpeople come to YT to learn. Your plumbers weren't born knowing this either and had to be told at some point.

  • @glendareeves2317
    @glendareeves2317 Před 3 lety +25

    thank you thank you thank you! Most of the other videos had the anode rod in a different location. You were the first to show the Bradford White under the hot water outlet which made things so much easier

  • @grimma1965
    @grimma1965 Před 3 lety +8

    Terrific and informative videos on how to consistently maintain a Bradford White water heater, and how to change the anode rod. So clearly and well explained, very well done! Thank you so much!

  • @PearComputingDevices
    @PearComputingDevices Před 3 lety +6

    Thank you very much for your guide, I couldn't find it on my water heater, now I can. Thanks!

  • @ernestns
    @ernestns Před 2 měsíci +1

    Thank you for the demonstration, this was very useful!
    Side note, applying both thread compound and Teflon tape can result in too much material on the threads, which can lead to improper threading or a seal that is actually less effective. The excess material might also clog the system downstream. Some manufacturers specify not to use both, as it can void warranties or lead to failures in the system due to incompatible materials.

  • @StevePowers-kv2zx
    @StevePowers-kv2zx Před 3 měsíci

    Your excellent video confirmed what my local contractor proposed here in Pennsylvania, regarding how to change the anode.

  • @markoflaplata2347
    @markoflaplata2347 Před 11 měsíci +5

    Good video thanks for creating. One note I would add. When ordering your new Anode Rode be sure to include a new heat trap. Mine was so corroded I was not able to transfer and reuse. You would think Bradford White would have included in the replacement rod.

  • @TheSod70
    @TheSod70 Před 3 lety +1

    Thank you for posting this!!

  • @williamscott6291
    @williamscott6291 Před 3 lety +20

    One complication stopped me and made me call the plumber to do this. The anode rod is torqued to a very high degree. I torqued on it until the entire tank moved and it would not break free. I was worried that I may break something so I stopped. The plumber used a hefty pipe wrench and really leaned into it. It took a good size man with a lot of muscle to unscrew it. Next time I will use my pipe wrench with a handle extender to get the leverage I need.
    He also said any pipe thread sealer that says TFE is suitable to seal the threads.

    • @_1ben
      @_1ben Před 9 měsíci +2

      possible put a back up wrench on the cold nipple

    • @woodstream6137
      @woodstream6137 Před 8 měsíci +8

      I've seen one recommendation of not draining the tank completely first but do turn the heater off so it has mass to stay put.

    • @jamesrecknor6752
      @jamesrecknor6752 Před 3 měsíci +2

      Impact wrench

    • @rolig3518
      @rolig3518 Před měsícem +1

      @@jamesrecknor6752 You can't use an impact wrench on the Bradford White setup. It's different from the standard setup on other water heaters.

    • @Vincerama
      @Vincerama Před 27 dny

      @@rolig3518 Is it because the impact wrench will unscrew the connector instead of the rod?

  • @ajg2558
    @ajg2558 Před 2 lety

    Excellent tutorial!!!

  • @Vincerama
    @Vincerama Před 27 dny

    Thanks for the video! I'm so tempted to buy a pair of Knipex slip joint pliers!

  • @jonnycromwell3042
    @jonnycromwell3042 Před 3 lety +3

    Thank you for the video assist. I has able to replace my magnesium anode rod with an aluminum rod quickly.

    • @vinista256
      @vinista256 Před 2 měsíci

      Aren’t magnesium rods better?

    • @jonnycromwell3042
      @jonnycromwell3042 Před 2 měsíci

      @@vinista256 I have hard water and it was recommended to swap the magnesium for aluminum by my FIL. He was a plumber. I’m not an expert so I took him at his word.

  • @Joseph-xt2qg
    @Joseph-xt2qg Před rokem

    Thanks! Great video!

  • @TLMuse
    @TLMuse Před 2 lety +6

    Thanks for this very clear description. My Bradford White TTW1 is in an unfinished partial basement, with only 23" clearance from the top of the heater to the bottom of the 1st-floor floorboards above it. Is there a way to replace the anode in this situation without disconnecting everything (including the propane line) and tilting it? Is that clearance enough to allow inserting a standard anode, at an angle? -Tom

    • @ullrsdream
      @ullrsdream Před 2 lety +6

      Some of the other anode rod replacement videos show or describe a bendable rod that has sections cut of the primary sacrificial metal with the central connecting element remaining stiff but flexible enough for low overhead clearance areas. I haven't seen one for the Bradford Whites specifically (or on the parts list I browsed for mine), so that would be a special case. Hopefully there is one available for yours or you might have to drain the H2O and disconnect the gas/electric line and pull it out to a space you can slide in the non flexible one as shown in this video.

  • @pipertoplay
    @pipertoplay Před 10 měsíci +2

    I have an electric Bradford White water heater, ( 50 gal. ), and need to change out the anode............how do you know which rod to get to replace the existing rod ?.......is aluminum better or is magnesium....does it matter ? .....any help would be greatly appreciated, thank you !

  • @denniss1211
    @denniss1211 Před 3 lety +2

    Good video ... you did not explain the regulator inside the tube and what is the white opening below the threads. Please explain the cold water anode rod. Thanks.

  • @jeremyregnerus4681
    @jeremyregnerus4681 Před 6 měsíci

    Is there any way to use a Corro-Protec anode rod with this style water heater? This is what was in our house. It's definitely due to be replaced, and we have fairly heavy sulfur smell.

  • @michaelmeandros551
    @michaelmeandros551 Před rokem

    Can an eroded rod/threads cause water to leak out onto the top and down the unit? Im near certain the old threads are the culprit of my leak, but since its the threads its below the top metal plate and cant get a visual like an exterior leak.

  • @Jeffstorm78
    @Jeffstorm78 Před rokem +2

    I have two follows up to a question below: If the rod is 3' long and is only corroded approximately 6" from top down and 6" from bottom up, that leaves 24" (2/3) of remaining consumable magnesium before replacement is needed, correct? Hypothetically, if this check was done 3 years after new installation and the corrosion rate is constant, the rod should last another 6 years before needing replacement, correct? If the first inspection was done only one year after new installation, I might replace the rod if they are only $40 and check it again in two years expecting to have approximately one more year of life left in it. Also, I'm not clear on the horizontal electrolysis explanation - I don't understand how the corrosion only took place reverse tapering from the top and bottom and not in the middle unless there is a less corrosive "wrap" around the entire magnesium center of the rod with the magnesium exposed at the ends. Is that a correct guess or am I completely misunderstanding horizontal electrolysis? Thanks!

  • @oskarpuka6037
    @oskarpuka6037 Před 2 lety +1

    Your content is so touching

  • @castercyrus9076
    @castercyrus9076 Před 2 lety

    Im not a plumber but what is the blue thing you applied on the thread?thank you

  • @Addicted2outdoors
    @Addicted2outdoors Před 3 lety +1

    This is a great channel. I look forward to seeing more videos. Can you do a video on how to install all of the components around a Navien for a radiant floor heat application?

  • @charl1em0uze89
    @charl1em0uze89 Před rokem +1

    Good Day. Thanks for the instructional video. I have a Bradford White M250S6DS-1NCZZ which is about 15 years old and we have lived in this house for 8 years. I know the anode has not been touched in those 8 ears but have no idea before then, so it could be 15 years old. It is not so easy to inspect the anode because the hot and cold water lines are normal copper (not flexible) and are soldered onto the inlets. I have purchased new parts (including a flexible line) to swap out. Just wondering if you have any special tips for removal of an anode that could be 8-15 years old?.... thanks very much in advance.

    • @_1ben
      @_1ben Před rokem +1

      On your own home you have the luxury of using a solvent like wd 40 multiple times, I would use pipe wrenches at least an 18" on the hot and use a back up pipe wrench on the cold nipple ,the back up wrench will help to give you leverage the bigger the wrench the easier the twist, stay away from channel locks on your project, one more tip double check that YOUR anode is on the hot water side, some are independent under a large nut on the top, if you still have a problem moving the nipple or nut with solvent and back up, possibly use heat (torch)

  • @jonharder6710
    @jonharder6710 Před rokem

    Thany you very much sir

  • @bassilbayazed3942
    @bassilbayazed3942 Před 2 lety +1

    What are the symptoms if the Anode vale is out

  • @rudy-vp2wg
    @rudy-vp2wg Před 7 měsíci

    How I know when my heater was installed. And where do I find the rod?.

  • @watteau6646
    @watteau6646 Před 9 měsíci +1

    What kind of channel-lock is that? I need to get one. Also, I'm going to have to use a hacksaw on the OEM anode rod I bought, because it's 5' long (even though it's the exact part-number on the BW heater I have), so I'll have to trim it a bit. Important tool to have if you have everything undone already, but your rod is too long for the tank.

    • @Vincerama
      @Vincerama Před 27 dny

      Knipex... supposed to be the king of slip-joint pliers! I need to get one too! But they are SOOO expensive! Probably worth it!

  • @peterhandelson1193
    @peterhandelson1193 Před 9 měsíci +1

    Do both sides have a rod, or just one?

  • @JeffBorger
    @JeffBorger Před 3 lety +2

    Thanks! This helps. My issue is that the union piece connecting the current anode piece to the copper pipe doesn't have a spinning bolt, but instead the copper pipe looks to be crimped into a joint which is screwed directly into the union piece. The copper pipe is then connect to PEX. Could I just unscrew the copper pipe from the PEX and union piece, or would I need to actually cut it? Thanks!

    • @Sxjones3
      @Sxjones3 Před 4 měsíci

      Curious if you ever got this figured out. I have the same issue.

    • @JeffBorger
      @JeffBorger Před 4 měsíci

      @@Sxjones3Never moved past this step. I still have the same anode rod in place. If I perform this myself, I assume I'll try and unscrew the copper pipe from the PEX and union piece.

  • @fisherbrown903
    @fisherbrown903 Před 2 měsíci

    How much average plumber charge To changr anode rod in bradfort white in nj?

  • @mcdevious2229
    @mcdevious2229 Před 3 lety +2

    Thanks!! Any idea if I can find a zinc replacement rod? (Smelly hot water.)

    • @ChiCan76
      @ChiCan76 Před 3 lety +4

      In case you are still experiencing smelly hot water, there is a service bulletin by Bradford White on this issue: www.bradfordwhite.com/forthepro-bulletins/hydrogen-sulfide-odor-rotten-egg-smell-and-chlorinating-water-heaters/

    • @mcdevious2229
      @mcdevious2229 Před 3 lety +1

      Thanks! I put in a powered rod. Problem solved.

  • @rocketstar9067
    @rocketstar9067 Před rokem +4

    I wish bradfordwhite would come up with a better design for anode rod, kinda like AO Smith so you don't have to remove the copper pipe. I come across alot of water heater that are hard piped in with no union so now it takes longer to swap out these anode rods on bradfordwhite they are the only manufacturer that has the anode rod built into the hot side connection.

    • @Btu555
      @Btu555 Před rokem +1

      I think I rather deal with open the hot water line than open the hex type since most connection is flex hose.

  • @tomking7367
    @tomking7367 Před 7 měsíci

    It was tough and I felt like giving up but for some reason I kept thinking about the first Rocky movie with Apollo Creed vs the Italian Stallion. Mickey said stuff like; “Keep hittin' 'em in the ribs ya see? Don't let that bastard breathe!” and “You're gonna eat lightnin' and you're gonna crap thunder!”

  • @dougwurtz2894
    @dougwurtz2894 Před 2 lety

    nice video...i have to take anode rod out, water has terrible oder if i don't.. is there anyway to fix that?

    • @watteau6646
      @watteau6646 Před 9 měsíci

      I heard that letting the rod get eaten up too much will start to create odors, so replacing it should help with that.

  • @whoknows4756
    @whoknows4756 Před 8 měsíci

    Rheems are easier to do then?

  • @randywl8925
    @randywl8925 Před rokem

    I have one of these, but only threaded part is above the tank.

  • @PendeltonWhiskey
    @PendeltonWhiskey Před 6 měsíci +1

    Rumor has it that the newer Bradford White water heaters no longer have a removable anode rod. Is this true?

  • @spacecoastz4026
    @spacecoastz4026 Před rokem +2

    Wonderful if you have a long pipe that can move away from the connection. Most don't. Just make the rod separate like it should be.

  • @MarkoSpeaks
    @MarkoSpeaks Před 3 lety

    so did you unscrew the hot or cold water pipe? cant tell in the video. whats under the other one?

    • @mattk6101
      @mattk6101 Před 3 lety +1

      It's the hot. You can see it at 0:45 if you look at the letters stamped into the tank

  • @joseartiaga3048
    @joseartiaga3048 Před 3 lety +1

    Best video... can I use brass nipples instead of those galvanized insolated ones and go directly to the flex supply lines instead is using unions

  • @jrboy2266
    @jrboy2266 Před 2 lety +2

    So do you do both cold and hot sides or just the cold side? Great video

    • @_1ben
      @_1ben Před 2 lety +2

      on a bradford and white the anode is on the hot side only

  • @stephen2220
    @stephen2220 Před 9 měsíci

    I noticed that you didn't use a Heat Trap? Is this not needed?

  • @RichardKuivila1947
    @RichardKuivila1947 Před 5 měsíci

    So that's why the warm water tastes funny ! (dissolved Anode Rod)

  • @robertlewis307
    @robertlewis307 Před rokem +2

    QUESTION: at the 2:40 mark you indicate the electrolysis goes flat ways, not up and down. Are you inferring that when the anode rod has a corroded section (in the video the top and bottom portions of the rod) that the corresponding level on the tank will no longer be protected...??
    The degradation of your anode rod didn't look to be that substantial. Are anode rods solid aluminum / magnesium, or just an outer layer... it was my understanding the rods were solid and even the "crusty" looking part was still protective aluminum / magnesium...

    • @ivanvarela3215
      @ivanvarela3215 Před rokem +2

      Yes yes you're mostly right, so long as there's some metal (>50%) left it'll still be doing its job.

    • @Jeffstorm78
      @Jeffstorm78 Před rokem +1

      I have two follow up questions to yours for clarification: If the rod is 3' long and is only corroded approximately 6" from top down and 6" from bottom up, that leave 24" (2/3) of remaining consumable magnesium before replacement is needed, correct? Speaking purely hypothetically, if this check was done 3 years after install and the corrosion rate is constant, the rod should last another 6 years before needing replacement, correct? If the check was done only one year after new install, I might replace it if they are only $40 and check it again in two years expecting to have approximately one more year of life left in it. Als, I'm not clear on the horizontal electrolysis explanation - I don't understand how the corrosion only took place reverse tapering from the top bottom and not in the middle unless there is a less corrosive "wrap" around the entire magnesium center of the rod with the magnesium exposed at the top end and the bottom ends. Is that a correct guess or am I completely misunderstanding horizontal electrolysis? Thanks!

  • @SpeedRobertson
    @SpeedRobertson Před 23 dny

    What is the regulator for?

  • @fishin360
    @fishin360 Před 8 měsíci

    How come no water didn’t come out of the copper pipe? Unless the tank was completely drained along with the plumbing?

  • @cohen860
    @cohen860 Před 3 měsíci +1

    Ok, folks, here's a question. Just learned all these water heater maintenance ideas for my 20-year-old heater! [New homeowner in brand new home 20 years ago, wth did I know!?] Anyhow, wondering if it's worth messing around with this now. No problems with the water heater. Maybe just wait 'til it doesn't work and buy a new one? Or, try this to get another 5-10 years out of the heater and if it doesn't go ok, buy the new heater? 🙂

    • @gaviomen
      @gaviomen Před měsícem +1

      Either do this, or just proactively change out the tank. The issue is that, when the tank fails due to corrosion, it's going to leak and get water EVERYWHERE.

  • @merseybeat1963
    @merseybeat1963 Před 7 měsíci

    I have a large Bradford White Water Heater it was installed 9 years ago..I never knew about this rod replacement. Is it too late to do it now ? One guy at Heating Oil place said forget it by now it's fused together. Let it run it's course and replace.

    • @joeyoungs8426
      @joeyoungs8426 Před 4 měsíci +1

      For what it’s worth, I finally did mine after fifteen years. The old one wouldn’t come out so I had two choices, cut it off and let it drop or what I ultimately did was tie a string through the outlet hole, cut it off above it and lower it in. Then used a file to get the crust around the base of the threads and then used the string to pull the old one out. The new one corrected the issue of the original having only threads exposed to remove it thereby definitely ruining it. So once the new one was in I had to cut the copper and re-sweat to be shorter. While I was at it I drained the tank and used one of those hose attachments to clean the base of the tank and installed an electronic scale blaster. Everything worked out fine and the scale blaster has helped to radically reduce the scale. It doesn’t necessarily eliminate it but it’s now a wipeable powder rather than a had crust.

  • @MakeMeThinkAgain
    @MakeMeThinkAgain Před 3 lety +1

    Anyone happen to know of a replacement ARTICULATED anode that will fit on a Bradford White URG 2100 H6N? I'm having a hard time finding this information and my plumber is not being helpful.

    • @ullrsdream
      @ullrsdream Před 2 lety +1

      Interested for a follow up post, was one available? I called the manufacturer for a part number since my unit was super old. One person in the comments also wanted a flexible rod for a BW unit.

    • @MakeMeThinkAgain
      @MakeMeThinkAgain Před 2 lety

      @@ullrsdream I gave up. My plan now is to simply replace it when it gets past 10 years of age. I'm hoping that by that time there will be non-steel tank options on the market.

  • @cjrwacatak2
    @cjrwacatak2 Před rokem

    Curious, do you have to drain the tank before this process?

    • @watteau6646
      @watteau6646 Před 9 měsíci +1

      I've seen other videos that say drain only a couple gallons. You'll need the rest of the "weight" of the water to keep the tank steady when you start cranking the wrench.

  • @johnstrupeck4668
    @johnstrupeck4668 Před 2 lety +7

    Video was informative, but replacement not so easy. We have a two story house with the water heater in the basement. Shut off the house water and the inlet to the water heater. When I started to loosen the union, water started flowing. Need to open a faucet on the second floor ( be sure to remove the aerator, then replace later.) then drain some of the water in the hot water tank. This allows the water in the house pipes to drain into the tank. So I loosened the union, and tried to remove the anode rod with the bottom part of the union as one unit as the video shows. No luck as the union came off easy. Now the old anode rod is stuck and the only gripping surface is the threads. If I damage the threads and cannot get the old anode rod out, I am in trouble. Nothing in the video about what to do in this case, which is probably more likely.
    So I put it back together and decided to replace the unit at the 10 year mark. Currently at 7 years.
    Replacement will not be a Bradford White, but a unit with a separate anode rod. I had previously changed out the anode rod every 5 years. Took me an extra 2 years to figure out the integrated anode rod - water supply thing.

    • @windsurfertx1
      @windsurfertx1 Před 2 lety

      I'm with you on that John, mine also only has about a 1/4 to 3/8 inch of threads exposed. I could use a pipe wrench on those threads but if it doesn't come out its a thousand plus bucks to replace the entire water heater. maybe I could remove all inlet, outlet, and over pressure device then remove the top cap on the heater (small sheet metal screws) to gain access to the unthreaded part of the rod. the more I think about it putting a pipe wrench on the last 1/4 inch of the threads would likely crush the pipe. that's a bad, bad idea, bad.

    • @billlee3069
      @billlee3069 Před 2 lety +2

      When doing a fixture repair, particularly in the basement, you are almost ALWAYS going to get water. The best thing to do is shut the main to the house off and open whatever water fixture is lowest in the house (a basement faucet or an outdoor garden hose bib) and allow the water to drain down. You will almost always still have water on the hot side so when working on the water heater, make sure it is powered off and drain water for the heater itself. Once done, be sure the water heater is completely full before turning the power back on or you will be replacing heating elements next. This is the life of a plumber.

    • @bob_frazier
      @bob_frazier Před rokem

      Quote "Now the old anode rod is stuck and the only gripping surface is the threads. If I damage the threads and cannot get the old anode rod out, I am in trouble. Nothing in the video about what to do in this case, which is probably more likely." EXACTLY. What to do?

  • @royf.2471
    @royf.2471 Před rokem +1

    so it looks like I would need at least three feet of clearance above the heater in order to do this, is that correct?

  • @Bendc1970A1
    @Bendc1970A1 Před 3 lety

    how is a powered anode rod installed into this type of tank?

    • @ullrsdream
      @ullrsdream Před 2 lety

      powered? Please explain. These parts function solely on chemical processes that happen between H2O and the metal of the anode rod. I think the youtuber mentions a powered exhaust venting set up rather than a passive chimney, but I'm not familiar with a powered setup for venting. Probably like a bathroom exhaust fan, it will force air to exit the pipe and water heater area than simply letting heat rise and carry the gases away. Cheers.

  • @cdays01
    @cdays01 Před rokem +1

    I wish I would have done my homework on the Bradford white prior to installing it for a customer. I told them how great powered anode rods are. I put them in every water heater on a well system.
    With this Bradford white I’m going to have to charge a customer every 4-5 years to put a new rod in. I have never seen this type of design before but that’s what I get for being in a rush to get a customer up and running.
    I was debating if I could put a rod on the cold side as well but I feel like the water would “short cycle” without going to the bottom of the tank.

    • @eegg6954
      @eegg6954 Před rokem

      Unless the water's really hideous, that heater should get you 12 years without ever touching the rod.

    • @jbroadbelt6
      @jbroadbelt6 Před 7 měsíci

      We are on year 11 same water heater.. water is still hot as balls

  • @am44_67
    @am44_67 Před 3 lety +2

    Unsure how I feel about pipe dope inside my water heater, will water come into contact with the lower portion where you applied teflon tape and pipe dope?

  • @zheng1987
    @zheng1987 Před rokem

    What’s the part number for this?

  • @Fluterra
    @Fluterra Před 3 lety +8

    You missed the initial part - how much water do you need to drain first??

  • @annonemus21
    @annonemus21 Před rokem

    is it necessary to drain the tank a little?

    • @cpd969
      @cpd969 Před rokem

      Releasing the tank pressure is more important

  • @ministryofdesignarizonarep3667

    I have to cut mine down about 1 foot.
    Yeah good point don’t forget the breaker and turn it off then the water supply. Drain a bit also. Open the hot water downstairs and drain a bit.

    • @davidkunces9266
      @davidkunces9266 Před 7 měsíci

      mfg do make a bendable anode rod now home depot sell it

  • @Itsme-jv4cd
    @Itsme-jv4cd Před rokem +3

    Oh man, I don't have room above my hot water heater to remove the anode rod

    • @watteau6646
      @watteau6646 Před 9 měsíci +1

      use a hacksaw. Cover the hole so no metal shavings get in. Then replace it with a segmented rod.

  • @mitchcollins7232
    @mitchcollins7232 Před 7 měsíci

    I need this exact replacement rod where and how do I get it?

    • @velcrofishsticks6002
      @velcrofishsticks6002 Před 7 měsíci

      Amazon sells them or a plumbing supply store that sells their water heaters should have them. BW doesn't sell to the public so your hardware store usually won't have them

  • @russbonneau9152
    @russbonneau9152 Před 2 lety +4

    how often should this be done?

    • @notny41
      @notny41 Před rokem

      The manual says ever 2 years

    • @watteau6646
      @watteau6646 Před 9 měsíci

      3-5 years I keep hearing. We have a water softener, and after 5 years (last year) the rod was corroded about halfway. Replacing it this year. They say soft water makes it more necessary to replace the rod more frequently, but 6 years isn't too bad! Most water heaters last about 10 years, but with good maintenance (like this, flush/drain, inspections, etc) it can last 20 years or more.

  • @brianbaweja7441
    @brianbaweja7441 Před 3 lety

    Can i add an electric anode to this?

  • @ronb8052
    @ronb8052 Před 2 lety +1

    I may be incorrect, but I was told there should be continuity between the threads on the anode rod and the water heater....so...don't use a lot of pipe tape...only teflon pipe dope.

  • @castercyrus9076
    @castercyrus9076 Před 2 lety

    Does all bradford have aluminum anode rod?

    • @TheLosiracer
      @TheLosiracer Před 2 lety

      Could also be magnesium. Look at the model number on your water heater to see which one you need.

    • @watteau6646
      @watteau6646 Před 9 měsíci

      mine has magnesium. Magnesium is also recommended if you have soft water.

  • @billlee3069
    @billlee3069 Před 2 lety

    Is that on the hot or cold side?

  • @furyofbongos
    @furyofbongos Před 11 měsíci +1

    "Regulator?" Did you mean heat trap? I didn't see any heat trap in that new rod/outlet.

    • @watteau6646
      @watteau6646 Před 9 měsíci

      I think he meant heat trap. I ordered mine separately from my rod so I'd have it just in case.

  • @bob_frazier
    @bob_frazier Před rokem +1

    Mine is NOT as shown. The old anode rod is stuck and the only gripping surface above the tank is the threads. If I damage the threads and cannot get the old anode rod out, I am in trouble. Nothing in the video about what to do in this case. HELP!

    • @ivanvarela3215
      @ivanvarela3215 Před rokem +2

      Just get a solid grip on it, wd-40 the hell out of it, get a long pipe for more leverage, and PUUUUSH

    • @ivanvarela3215
      @ivanvarela3215 Před rokem +2

      The whole tank may move a bit before you break it free. Don't worry, it's a big ol' thread, it won't break and leave you stranded.

    • @bob_frazier
      @bob_frazier Před rokem +1

      @@ivanvarela3215 Yep, it all went just like you said. They really could put more of it above the tank though. Thanks.

    • @177BCardinal
      @177BCardinal Před 8 měsíci +1

      Excellent Point! Threads only above the top necessitate REPLACING the anode rod instead of inspecting it and putting it back in if it's got life left in it. NOT GOOD, BW! Butcher your threads.

  • @mikezieg80
    @mikezieg80 Před rokem

    Power turned off?
    No draining?

    • @watteau6646
      @watteau6646 Před 9 měsíci +1

      He left this stuff out. Yes, you should turn the power off (on electric), or turn the gas to pilot or vacation, then turn off the cold water inlet, open a tub faucet, and drain a couple gallons from the tank. Perhaps even wait an hour or two so the tank is cooler.

    • @cohen860
      @cohen860 Před 3 měsíci

      @@watteau6646 Thanks

  • @agentmango
    @agentmango Před 2 lety +13

    Nothing against this video, thank you for making it.
    But how did the engineers remotely think this was a good design choice?? What a headache (and opportunity to introduce leaks) it is to have to disconnect the hot water outlet. I'm disappointed my house came with this model.

    • @powerbeast5691
      @powerbeast5691 Před 2 lety +12

      Bradford White do not want you to change the anode rod. They prefer that you buy a new water heater sooner. Thats why they designed it in this matter.

    • @ivanvarela3215
      @ivanvarela3215 Před rokem

      ​@@powerbeast5691 shit...ima make a point of getting this sac. anode replaced

    • @Prosecute-fauci
      @Prosecute-fauci Před 10 měsíci +3

      Bradford whites are the easiest water heater models to change the anode on. I’m not sure what you are complaining about.

    • @agentmango
      @agentmango Před 10 měsíci +4

      @@Prosecute-fauci my complaint is that a well-designed water heater (which Bradford White isn't) wouldn't incorporate the anode into the hot water connection, it would have an anode that can be replaced without disconnecting any water connections.

    • @Prosecute-fauci
      @Prosecute-fauci Před 10 měsíci +1

      @@agentmango the reason I am saying that it’s actually the most convenient method is because the other brands require you to completely disassemble the top of the water heater to get to the anode rod. This includes both the cold and hot water connections.

  • @billysmith5721
    @billysmith5721 Před 3 lety

    i have a gas bw hw heater

  • @miguelcolon8929
    @miguelcolon8929 Před rokem

    Can I was any name brand anode rod?

    • @miguelcolon8929
      @miguelcolon8929 Před rokem

      Use

    • @watteau6646
      @watteau6646 Před 9 měsíci

      I was going to do that, but because there could be issues with the fittings/threads, etc. I bit the bullet and ordered the correct part number from supplyhouse.

  • @corymiller7481
    @corymiller7481 Před 3 lety +4

    I tried to change out my B-W anode rod yesterday. When I got the hot water outlet pipe disconnected, the only thing above the top of the water heater itself was the threads--no grip surfaces were exposed. There's no outlet nipple. How do I get the anode rod out?

    • @Vl7248
      @Vl7248 Před 3 lety

      Sounds like it broke off. Replace the hot water heater entirely. Especially if it’s 10+ years old. They rarely last much past 15

    • @davidshreve8368
      @davidshreve8368 Před 3 lety +2

      @@Vl7248 No! It did not break off. Ive seen two of these, cause I've got one. Only the the threads are above the top of the metal cabinet. can you remove the top cap on the metal cabinet after removing the 5 short screws that holds it to the main top part of the outside cabinet? Im having trouble doing that.

    • @kurtvonfricken6829
      @kurtvonfricken6829 Před 3 lety +1

      @@davidshreve8368
      BW doesn't give you much nipple to grab. Some people suggest dropping a 5/8” bolt into the nipple. You have to grab the threads with the pipe wrench. It sucks that you have to destroy the nipple to get it out.

    • @MarkoSpeaks
      @MarkoSpeaks Před 3 lety +3

      I have the same problem! cant remove the rod itself, impossible to grip onto a round pipe and twist!! never buying BW again...

    • @MarkoSpeaks
      @MarkoSpeaks Před 3 lety +1

      were you ever able to remove it btw??

  • @nevose9046
    @nevose9046 Před 2 lety +1

    Just a common sense point out before you get someone killed or burned with hot water. The water should be turned off and the boiler off or set to a very low temp so it doesn't initiate. Also pressure from any hot water faucet should be opened to relieve pressure..

    • @watteau6646
      @watteau6646 Před 9 měsíci +2

      Yes, and a couple gallons drained from the top as well.

  • @RichardKuivila1947
    @RichardKuivila1947 Před 5 měsíci

    A lot of western states have basement floors that can Rise/Fall by 2-3" so DON"T have solid copper pipes !

  • @angelmtzmtz8799
    @angelmtzmtz8799 Před 11 měsíci

    I bought this water heater czcams.com/users/postUgkx8G49mV71sAzUl9shXyLW-r3XgHH9EVh1 for use in my bus conversion. I installed it under my kitchen sink and it is fed by a high efficiency on-demand LP water heater. It is both a backup hot water source as well as a water saving device since we have hot water on demand rather than having to wait for the gas on demand water heater to finish its ignition cycle. I decided on this water heater due to the fact that it only draws 1300watts when it's ON instead of the 1500 watts that most Water heaters this size draw. In an RV a couple hundred watts can be a big deal. With very low standby losses, I don't have to worry about excessive power consumption. When propane is not available for our gas water heater, in conjunction with our low flow shower head there is enough hot water available to shower, albeit we won't be taking "hotel showers." Also very happy with the recovery rate of this water heater. Granted, it is quite small, but it does exactly what we need it to do.

  • @waynetcampbell
    @waynetcampbell Před 4 měsíci

    Has anyone ever installed a plug in anode rod on a Bradford White (power pack to AC outlet)? It looks like a long term solution, but at $180.00 I want to ask first! Thanks!

  • @michaelfriedman2221
    @michaelfriedman2221 Před 2 lety +4

    Unfortunately for me, my hot water copper pipe does not have a free spinning union junction to the outlet pipe. It has a hard soldered copper connection. I would have to call a plumber to disconnect the pipe 😒 I guess this is done to discourage DIY maintenance and to shorten the life span of the tank generating more revenue for the plumbers.

    • @jeffirish7236
      @jeffirish7236 Před 2 lety +5

      Just cut the pipe 12” or so above connection to water heater and buy a shark bite connector to put it back together. The plumbing fittings now days are meant for DIYers.

    • @eegg6954
      @eegg6954 Před rokem +1

      It's done by a plumber who didn't want to spend $5 for a union. But don't worry, you'd never wrench that anode rod out of a Bradford White after five years anyway.

    • @MS-ze2xm
      @MS-ze2xm Před rokem +1

      Same here. I will look for a different brand once this one is done for. I understand wanting to keep sales up, but these manufacturers need to considered DIYers. I have mouths to feed, cannot keep hiring "professionals" to do simple household maintenance.

  • @aceyorba
    @aceyorba Před 2 měsíci +1

    Just hope you have 4 feet of space over your water heater to pull the rod. I'm sure the new rod is 150 bucks from the manufacturer .

    • @davidpreece5824
      @davidpreece5824 Před 2 měsíci +1

      You can lean the heater if you drain it down.

  • @billywill903
    @billywill903 Před 3 lety +4

    This is the worst design and a real pain in the A$$ to deal with.

  • @jameszhao6628
    @jameszhao6628 Před 2 lety +1

    TFE tape is not recommended. Because it’s non-conductive, if you apply too much and the thread won’t crash it then the anode rod and the tank body won’t contact. The anode rod doesn’t work. So cream style sealer is better.

  • @douglaswindsor120
    @douglaswindsor120 Před 2 lety

    Used to be plumbers didn't use dielectric couplers because of ignorance of how electrolysis works after the learned they knew most people don't know they need replacement at regular intervals most won't tell as they know that soon after they are used up your tank develops a pinhole and starts to leak a hole that gradually increases meaning you need a new tank sometimes in less than 5 years and that is covered under warranty they must be hurting bad now that pex is the new normal tanks properly installed with dielectric couplers will regularly last 30 years or more before sucoming to the other killer of gas hot water tanks sentiment on the bottom of the tank another unit causing tank replacement is the dip tube wearing out and when you ask a plumber why you only get 5 gallon of hot water they tell you it needs to be replaced an expensive cost when a 100 dollars max replacement of dip tube will fix the problem you're the first utube video I've seen on fixing the problem of tank corrosion so maybe there are still some good plumbers out there although one thing I never did was leave a tank hooked up without dielectric couplers installed

    • @eegg6954
      @eegg6954 Před rokem

      All Bradford Whites have dielectric couplings now.

    • @Jeffstorm78
      @Jeffstorm78 Před rokem

      Douglas - OMG this sounds like you really know what you are talking about but I can barely follow most of it because it's one loooooooooooooooooooooooong sentence with not one period!

  • @incognitotorpedo42
    @incognitotorpedo42 Před měsícem

    Kinda unrealistic to have the anode come out this easily. Mine was really hard; I really had to lean on it, and barely managed to get it off. Some people recommend impact wrenches.

  • @MichaelMantion
    @MichaelMantion Před rokem

    tape and liquid??? why both?? that is silly

  • @randyvfromtheperch
    @randyvfromtheperch Před 5 měsíci

    OK overall but you wrapped the teflon tape onto the anode rod threading BACKWARDS.
    .Also, you didn't sho0w shutting off the water or draining the tank as part of this procedure.

  • @sov19871987
    @sov19871987 Před 6 měsíci +1

    Bro missed like 10 other steps 😂

  • @Corinthians--nx4oz
    @Corinthians--nx4oz Před 2 měsíci

    I’ve been plumbing for over a decade I never seen anyone put dope on the threads then tape. Usually tape then dope. Interesting I guess haha
    1 Corinthians 15:1-4
    King James Version
    15 Moreover, brethren, I declare unto you the gospel which I preached unto you, which also ye have received, and wherein ye stand;
    2 By which also ye are saved, if ye keep in memory what I preached unto you, unless ye have believed in vain.
    3 For I delivered unto you first of all that which I also received, how that Christ died for our sins according to the scriptures;
    4 And that he was buried, and that he rose again the third day according to the scriptures:

  • @ChildrensBibleStories
    @ChildrensBibleStories Před 2 lety

    TURN OFF THE WATER FIRST!!!!

  • @topduk
    @topduk Před 2 lety +1

    Horrible system, and the anodes are almost double the price too.

  • @noneintel2119
    @noneintel2119 Před 2 lety +4

    I would never buy this company's product because it is too much work to change an anode on it.

    • @djintence
      @djintence Před 4 měsíci +1

      I don't blame you but they are the BEST HOT WATER HEATERS in the market... GIVE N TAKE...

  • @daltonhewitt7380
    @daltonhewitt7380 Před 7 měsíci

    what the fuck, why not just have a normal anode rod not this proprietary one. ugh