ACS Gas Training - Installation Faults Q&A
Vložit
- čas přidán 4. 08. 2024
- Gas Training. Help and Advice for your Gas Assessments.
★☆★ Thank you for watching my video! Hope you enjoyed it, make sure you like, comment, share and SUBSCRIBE to my channel and click the 🔔 icon for notifications when I post a new video. If you have questions please feel free to leave them in the comments section below.
⚡️ Subscribe to Allen Hart on CZcams
☆ Check out more useful videos:
► TB118 ELECTRICAL SAFE ISOLATION - Boilers - ACS Gas Training • TB118 ELECTRICAL SAFE ...
► Gas Training: www.youtube.com/watch?v=QiMDh...
► Underfloor Heating Tutorials: www.youtube.com/watch?v=R1axD...
► How To Build A Man Cave: www.youtube.com/watch?v=8a4hL...
► DIY At Home: www.youtube.com/watch?v=06j48...
#plumber #boiler #GasTraining
Thank you for watching my video: Gas Training - Jak na to + styl
TB118 ELECTRICAL SAFE ISOLATION - Boilers - ACS Gas Training czcams.com/video/5mIb8p3mYlQ/video.html
TB118 Electrical Safe Isolation - When Things Go Wrong czcams.com/video/m7ffKTYo7Jk/video.html
New Gas Boiler Installation - Benchmark Code of Practice czcams.com/video/Lf87taSzaIA/video.html
Absolutely bloody brilliant, please keep up the good work.
Allen your a GEM thanks for posting these sort a videos, god bless you 🙏
Thank you so much Allan these videos helps a lot.👍
Very helpful video Allen, thank you. Thumbs up from me, and this is the comment 😃
Hi Allen I'm really happy you make these videos and go out your way to help others become successful.
Just one correction because I'm preparing for the test soon and going through past papers. After the ECV it's the regulator that reduces the gas. They try to trick us by putting governor as one of the answers.
I m very satisfied your video.
Thank you very much
Great Video Allan. 👍🏿
Another great video and helpful ,
You don't look a day over 30 Allen 😎
Here is another thumbs up 👍
Thanks.
Thanks Allan
Love your channel
Always great videos cheers al and Elliot
Thank you Jack
Great video. I have my acs in 2 weeks time
Tanx for the upload good of you both to do questions answer video's would be valuable for people coming in to this trade keep up the good work👍
Thanks. Did you spot all the faults?
@@AllenHart999 yes Allen pretty much straight away👌
E K but you didn’t add any comments 😂 My plan Didnt work then😂 I was hoping we would get loads of answers in the comments. Thanks
@@AllenHart999 sorry to busy talking on the mobile while watching your video
@@ek6868 Thank you.
Awesome!!
Did you spot all the faults?
@@AllenHart999 I think so?!
Mi's need to be easier to find important information.
As a new gas engineer or an old one like me with bad memory, I can't always remember how to put a boiler in high/low mode to run tests. And it's not always easy to find the optimum gas ratios in the mi either. Worcester are good in this case. Easy to put into service mode and easy to find correct readings also
Nice one Al!
Did you spot all the faults?
@@AllenHart999 got the electrics too close to the pipe. that pipe teeing up through the ceiling should be clipped/supported too right? what would happen with those wires in the end? either the pipe or the wires need to be moved? would end up quite a job?
Good
Did you spot all the faults?
👌
11:57 that pipework reminds me of that Windows 95 pipe screensaver with pipes everywhere
👍👍👍👍
Hi Allen, I passed my gas right out of college which has expired 2 years ago... used to have vast experience on gas works but been on site now for 2 years... do you have any advice as I want to renew my gas but feel I have forgotten a shed load
Elliot said “gas rate the meter” would you not be gas rating the appliances?
👍👍👍👍👍👍
💝💝💝
Looked at this one phone need to get on the laptop to have a look at the benchmark.
Great videos thanks,Regards the Baxi service manual is this only issued by Baxi if ive been on Baxi training course ?
can only see installation manuals on baxi website .
You can read the installation instructions, I got my manual from Baxi, Thanks.
Tightness Test - Low Pressure Gas Installation - Gas Training czcams.com/video/l_m3QwJKnhE/video.html
Brilliant video ....
Clipping distance
Clips required on boiler pipework
Too close to electric wire
Think I spotted flux residue on meter pipework
Sleeve / sealed
Was that earth 6mm
Pipe sizing looked correct
AR flue seal
Bench mark & cp12 incorrectly filled out
Dont think the condense pipe should be open ....surely should be sealed !
DLM looks ok @ 4ohms
Final Flue integrity test with case on
Wonder what cooker was like lol.
Have you got any videos on when you would ID a cooker Allen.
Thanks for your time doing these videos. 👍👏👌
Merry Christmas
@@AllenHart999 Merry Christmas 🎄 to you and family 🌲🌲🌲🌲
Absolutely brilliant video! I only got these because I’ve had my face in the viper gas books for the past couple of months.
The other two things that I thought might be an issue is where the earth cable for the meter comes through the wall it has to be sleeved / sealed. The clips look like steel on the copper gas pipe, I might be wrong but doesn’t that cause corrosion?
Adjust gas valve then test with case on I always analyze with case off test the flue seals and burner seals then I will test with the case on
You don’t need case off to do gas valve 👍
0.4 good ;) as blue screen 👌
What do you mean
I get you now. DLM PRO 😂
@@AllenHart999 haha that's it 😉
🔵 Good or check
🔴 fault
Great bit of equipment for engineers
@Viper Gas I cannot afford one lol.
@@AllenHart999 🤣🤣
Allen on a separate note, what's your opinion on Heatline Capriz 2?
Customer wants the cheapest boiler can get but still wants something decent. What you reckon?
Main eco compact is a budget price but it’s a Baxi 800. That would be my choice
I got clips and electric wires.
Well done
Bonding also
What size should the bonding be? Thanks.
@@AllenHart999 no more than 600mm from first tee
Clipping?
Yea i notice that too, and gas pipe going to the boiler to far from wall without clips.
Close to electric cable gas pipeline running
Boiler flue pipe not sealed properly
Surely electricians shouldn't be fitting stats to condensing boilers as their breaking a combustion seal on positive pressure case seals 😳
Inappropriate clips on gas pipe
👍👍👍👍
Wouldn’t gas boilers be banned by 2025 sir?
No
So what year would they ban gas boilers????
Gas boilers are not getting banned, but as from 2022 I believe all new build properties will not be allowed gas installed, they will need to be electric heating, however there are trials as we speak in the midlands area where hydrogen is being introduced into the gas supply to ascertain whoever we can switch to a mixture of gas and hydrogen for the remaining millions of boilers out on the patch. Hope this helps
@@kevincranfield5235 thank you it does
@@kevincranfield5235 so whats going to happen to the gas engineers when they start putting in electric heating in new homes?
J
Thanks for the comment.
You could try speak up that guy is not speaking loud enough I'm on bus with earphones in and cannot hear him as he's whispering
Great Video Allan. 👍🏿