If Span is 8 Meters b/w Two Columns Than what should be the depth of Beam?How to Find Depth of Beam?

Sdílet
Vložit
  • čas přidán 3. 07. 2020

Komentáře • 59

  • @hoangkybactien7207
    @hoangkybactien7207 Před 3 lety +14

    L/20 is for steel beams such as I/H beams. For steel-reinforced concrete beams, it should be L/12 or L/15 as minimum. I am not a civil engineer, but that is what I've come up.

  • @isaacfrimpong92
    @isaacfrimpong92 Před 3 lety

    thanks for the support and education

  • @civilengineeringtolifeengi3333

    HELLO FRIENDS & ENGINEERS , IT IS A GOOD AND HELPFUL VIDEO .

  • @qasimalibadi1302
    @qasimalibadi1302 Před 2 lety

    You deserve super like & admire

  • @Boss-gk8kc
    @Boss-gk8kc Před 4 lety

    How about length of beam is 8m but existing column is flush in the wall size 20*60. Is the column ok?

  • @josephoyek6574
    @josephoyek6574 Před 4 lety

    Is this formula used in the actual job setting? You said the final depth will still depend on the loading carried by the beam. Won't this require software like etabs or staad?

  • @md.mizanurrahmanaru3128
    @md.mizanurrahmanaru3128 Před 4 lety +1

    ♥ U Sir,,,,, From Bangladesh,,

  • @noliwenceslao2996
    @noliwenceslao2996 Před 2 lety

    Good morning Engr. Is it possible to construct a beam, 12 meters in length between two columns using I-beam for a two storey house?

  • @ayoubenaciri
    @ayoubenaciri Před 4 lety

    Thank you Sir so much 🙏🙏

  • @manisharma1831
    @manisharma1831 Před 4 lety +1

    sir can you please explain singley and doubley reinforced beam.. and also axial and biaxial column...

  • @sa-xc4lj
    @sa-xc4lj Před 3 lety +1

    hello sir If my span is 10 meters between two columns can I use trussed beams ?

  • @mithunprince9501
    @mithunprince9501 Před 2 lety

    For 10 meter span ,what will be the depth and width...??? Is it possible to make beam for 10 meter length ( simply supported)....???

  • @civilengineeringtolifeengi3333

    This is very basic but helpful video ...Good Explanation .

  • @fayazfaizan5070
    @fayazfaizan5070 Před rokem

    Does it apply in drop beam also r only great beam

  • @saeddnafee5820
    @saeddnafee5820 Před 3 lety

    Salam , can we mix between column for example en the center diffrent from the other.

  • @stanzingurmat3824
    @stanzingurmat3824 Před 2 lety

    If d distance between two columns 6mtr
    What should d columns size is

  • @apurbadatta2485
    @apurbadatta2485 Před 2 lety

    Sir , this 600 mm beam that you said,, is it including slab or excluding slab ??

  • @m.v.b1
    @m.v.b1 Před 4 lety +2

    Hi bro make a video on 30 foot span for commercial building
    With column size and etc

  • @sushilrajput3047
    @sushilrajput3047 Před 4 lety

    Sir issme modification factor use
    nahi hoga kya

  • @apurbadatta2485
    @apurbadatta2485 Před 2 lety

    Dir, you said the beam depth is 8000/20= 400mm,, my question is ,,
    Is this 400 mm beam including with slab thickness ?? or it is excluding slab thickness...

  • @mcan-piano4718
    @mcan-piano4718 Před 3 lety

    I am confused cuz in other codes it says the depth of beam should be for simply supported SPAN/12 instead of SPAN/20

  • @dilshikadilshi8103
    @dilshikadilshi8103 Před 4 lety +1

    Super... you are my favourite teacher sir...

  • @mib9550
    @mib9550 Před rokem

    When do you use D=L/16? You have used this in previous videos.

  • @dfnskJDmfbksdcj
    @dfnskJDmfbksdcj Před 13 dny

    Can I have 8 meter long slab without beam?
    I mean - slab will be resting on columns which are apart from each other by 8 meters, and no beans between columns

  • @diamondbracelette
    @diamondbracelette Před 2 lety

    Using what material?

  • @rozayhomesdesign301
    @rozayhomesdesign301 Před 2 lety

    Please what do you mean by depth of beam.

  • @interiordesign4650
    @interiordesign4650 Před rokem

    His value is bottom size or including ( Lenter ) RCC slap

  • @mmmmmmmmmmmm672
    @mmmmmmmmmmmm672 Před 2 lety

    A good soil condition..I have to built a 4 story house...my architect designed 20feet beam ...our constructor planning to use 20mm 4 steel bars...also colum with 16mm 4 steel bars and 10mm 4 steel bars..is it safe..

  • @nafeedhnaina5064
    @nafeedhnaina5064 Před 4 lety +1

    What about the steel size, number of rods, cover & stirrups Spacing & dia

    • @nafeedhnaina5064
      @nafeedhnaina5064 Před 4 lety

      Can u plz do this video once again with examples for each condition(cantilever beam & continues beam) for easier understanding?

  • @RanjithKumar-di6tk
    @RanjithKumar-di6tk Před 3 lety

    Fixed beam?

  • @jerrychibunna1892
    @jerrychibunna1892 Před 3 lety +4

    My question is for span of 7.6m in your earlier tutorial you said for span of 7.6m beam btw two columns the column size will be 400mm x 400mm and that the depth of beam is 7.6m/16. How come in this tutorial you said the depth of beam will be span/20 instead of span over 16. And if 7.6m span the column size is 400 x 400 I am thinking 8m will be 421mm x421mm taking reference from your previous lecture on 7.6m span

    • @michaelacheampong2869
      @michaelacheampong2869 Před 3 lety +1

      These ratios are the "span to depth ratios" are the minimum required so that the beam does not deflect based on it's own self-weight as such whatever depth you get from the basic ratios add say 150mm or 200mm to it to improve the moment resistance capacity of the section else depending on the load applied the beam might fail or require more require rebar ,in which case you will have to widen the width of the beam so that you arrange bars and still have adequate space around them for concrete .

    • @saleemqazi6242
      @saleemqazi6242 Před 2 lety

      I have also noticed the same case which you mentioned above.....

  • @udayam77
    @udayam77 Před 3 lety

    I was wondering if you could do a video on depth of continuous beam. Thanks.

  • @mubashirbashir8214
    @mubashirbashir8214 Před 4 lety

    Assalamualaikum sir can u teach us the surveying also please

  • @merchanthandson5271
    @merchanthandson5271 Před 11 měsíci

    Please tell where you are getting formula? Because i seen a formula...
    Depth of beam=L/10 ; Width of beam=L/12. For a 2 floor building but the L should not be greater than 6meters.

  • @SANJADHAV475
    @SANJADHAV475 Před 3 lety

    अगर ग्राउंड फ्लोअर के हॉल की साईज 21 बाय 10 हे तो कॉलम और बीम की साइज क्या होनी चाहिये

  • @avdheshbodhidharma8790

    hello
    sir
    sir kiya aap autocad complete tutorials series bana shakte hooo please
    thank you

  • @mohanakrishnan1150
    @mohanakrishnan1150 Před 2 lety

    Good👍

  • @FoodforThought-Plus
    @FoodforThought-Plus Před 2 lety

    as a general rule divide the span by 15

  • @hafizadnan592
    @hafizadnan592 Před 3 lety

    Asalamualaikum brother..
    It is Hafiz Adnan from Kashmir (Jammu and Kashmir)
    Hope u will be doing fine
    Firstly u used L/d formula for calculation of effective depth of beam
    Then u said I can bet that it will fail in very first trial...
    Then how can i myself decide

  • @Boss-gk8kc
    @Boss-gk8kc Před 4 lety

    How about the width of the beam? You only discussed depth

  • @sso-m-ai
    @sso-m-ai Před rokem

    I am looking for someone who can provide full report for Steel Structure - 700 sq Feet G + 3 Storey

  • @IbrahimKhan-gd1df
    @IbrahimKhan-gd1df Před 3 lety

    I need sami sir's mail il, plz

  • @ramakantsalam6132
    @ramakantsalam6132 Před 4 lety +1

    Why it is not 400 mm depth according to d formula......

    • @civilengineeringtolifeengi3333
      @civilengineeringtolifeengi3333 Před 4 lety

      can be used , it is just example . all other reality factors are also count . Like steel quality , workmanship and site conditions etc. , So depth was taken little more .

    • @maheshpratapsingh4049
      @maheshpratapsingh4049 Před 4 lety

      @@civilengineeringtolifeengi3333 little more?? It's almost double. Ratio should be taken span / 10 for simply supported beam...

    • @mcan-piano4718
      @mcan-piano4718 Před 3 lety

      @@maheshpratapsingh4049 yess, cuz actually in other codes or videos that ı watched or website, its mostly taken as SPAN/10-12 . I suggest u to use SPAN/10 if u wanna be safe OR SPAN/12 if u want adequate and SPAN/16 if u want it to be just okay

  • @bhabajitbarman653
    @bhabajitbarman653 Před 2 lety

    if is code is not safe for 8m span.. who the hell designed this is code

  • @arfatullah5632
    @arfatullah5632 Před rokem +1

    On which basis you say that..? What types of code you are following..?? Also mention the code.. It is just only time wasting

  • @saleemqazi6242
    @saleemqazi6242 Před 2 lety

    Dear admin I thing you have not enough capability to answered all the comments give below 👇👇👇👇

  • @Kpraveen1407
    @Kpraveen1407 Před 11 měsíci

    Hindi mai banao iss video ko

  • @pong3753
    @pong3753 Před 2 lety

    Bobo

  • @seksantipapala1878
    @seksantipapala1878 Před měsícem

    ขอบคุณมากครับ