How to Use Fieldpiece Wireless Charge and Test Kit

Sdílet
Vložit
  • čas přidán 20. 08. 2018
  • How to use the Fieldpiece JL3KH6 Wireless charge and test kit on #ToolboxTuesday. Want to run tests on a system while you are NOT out in the heat? This is a system that is capable of just that with the Job Link app.
    Take a full system snapshot quickly and easily with the JL3KH6 Charge and Air Test Kit. This kit consists of 2 pressure probes, 2 pipe clamps, and 2 psychrometers in a quick access padded case. All measurements can be sent up to 350’ away directly to your mobile device with the Job Link app.
    Buy a Fieldpiece JL3KH6 today at:
    bit.ly/2BEym7E
    Toolbox Tuesday covers how to use tools, accessories, tips, hacks and best practices of the HVAC industry. Learn about HVAC, duct, coil, flame sensor, sequence of operations, electrical, condensate lines, ohms law, air distribution tools and more.
    Learn more about how to become an HVAC Tech, BuildATech class, HVAC training and HVAC tips and tricks at:
    www.lennoxpros.com/hvac-training
    Audio licensed through: www.audioblocks.com
    Video produced through: www.ellevengroup.com
  • Jak na to + styl

Komentáře • 62

  • @fromdowntown2963
    @fromdowntown2963 Před 2 lety +2

    I know that guy. He, was Senior instructor, at the Hvac school I attended back in 2015. Wow that's crazy.

  • @alangivens7983
    @alangivens7983 Před 3 lety +5

    Great video and very professional. Looking forward to seeing more of your content.

  • @jaytide6742
    @jaytide6742 Před rokem +2

    Thanks for taking the time to post this for us. Nice work.

  • @mychoclabwinston
    @mychoclabwinston Před 4 lety +1

    Love mine so far, need to get the adapters to charge with, pain in the ass taking on and off, but the complete report is amazing

  • @rubenarteaga7701
    @rubenarteaga7701 Před 3 lety

    Excellent presentation! Great job thank you

  • @larryseibold4287
    @larryseibold4287 Před 3 lety +2

    good video and demonstration. I think you need one more temperature probe to get the outdoor DB for supper heat calc, unless it is built in to one of the outdoor clamps, but i think you have to measure this on your own and manually enter it in the app??

  • @carloscantarero1
    @carloscantarero1 Před 2 lety

    Great video. Great explanation. Thank you.

  • @4xprops457
    @4xprops457 Před 5 lety +1

    Great video!these probs are awesome!!!

  • @christophersharp1884
    @christophersharp1884 Před 3 lety +12

    Now they need to include all of these measuring tools pre installed in units so you can just connect an app to the unit and its good to go.

    • @seanmathews1826
      @seanmathews1826 Před 2 lety +5

      Carrier does with the VNA4 Series condensers.
      you can do exactly that. Link with Bluetooth and bam you have pressures super heat and sub cooling.

    • @murkyturkey5238
      @murkyturkey5238 Před rokem

      @@seanmathews1826 wow that’s insane, I’ve never seen that 😂

  • @kenmoses8
    @kenmoses8 Před 3 lety +14

    Does anyone add a T fitting to the suction probe so you can charge when needed?

  • @thecreativehuman75
    @thecreativehuman75 Před rokem

    First time viewer, new subscriber. Great video. Thanks!

  • @eyayouestifanos9746
    @eyayouestifanos9746 Před měsícem

    Thank you sir

  • @Aprillex
    @Aprillex Před 2 lety +1

    Need to be able to input model numbers on systems in the app for all info.

  • @JessYalyson
    @JessYalyson Před 3 lety

    Hey I work for a community that's 8 story. Will the interior signal probes reach out to the roof where my condensers are? Thanks!

  • @STS4747
    @STS4747 Před 4 měsíci

    Would you say these are better then the digital field price gauges?

  • @kevinharris3327
    @kevinharris3327 Před 2 lety

    Anyone have trouble linking the large pipe clamp , we do commercial and need that we have 3 and none are linking up

  • @victorvillafane252
    @victorvillafane252 Před 5 lety

    I got mine today let’s see what’s gonna look good to me thank you sir

  • @pedrocervantes7561
    @pedrocervantes7561 Před 6 lety +8

    Error because condenser coil is not getting proper airflow to repel heat you have your service panel off.

  • @tommyhummer2762
    @tommyhummer2762 Před 4 lety +1

    Any videos on recovering refrigerant with these?

    • @kenmoses8
      @kenmoses8 Před 3 lety

      Tommy Hummer adding a T to the service port for charging and recovery? Haven’t tried yet. Still have sman480

  • @bestiekena842
    @bestiekena842 Před 3 lety +1

    does it automatically convert super heat sub cooling?

  • @WreckingCr3W2
    @WreckingCr3W2 Před 4 lety

    So you just use these tools for system diagnostics, and then use your regular guages for charging? Is there any way to charge a unit with this kit?

    • @ericlarson8489
      @ericlarson8489 Před 4 lety +3

      You get a T adapter.

    • @TheRealoldcar
      @TheRealoldcar Před 4 lety +2

      Yes, use a tee adapter on the LP side, control the charge amount with a ball valve or you can also attach your manifold especially if you are using blends and need to attach a vaporizer, just one example. You will also find measure quick with these sensors a game changer.

    • @dburks1273
      @dburks1273 Před 2 lety

      Yes use a charging tee

  • @tonybarra6
    @tonybarra6 Před 4 lety

    If the unit is low in refrigerant. How you add it.. Too fancy tools. I prefer the sman480

    • @michaelcooper9475
      @michaelcooper9475 Před 4 lety +3

      By using a Tee in line with the probe you can charge with refrigerant. Appion and Yellow Jacket sell valve core removal tools that have a side port and valve that can be used to charge. Out of the box, you cannot charge with this tool. With either of the previously mentioned valves you can. This makes data processing and customer service a breeze, no more writing everything down! You simply have to send it to the customer's email. Hope this helps!

    • @jasonreitz6049
      @jasonreitz6049 Před 3 lety

      @@michaelcooper9475 hey my question is, if you use a core removal tool, wouldn’t you have to pull the shrader on the service valve since the core tool won’t depress the schrader? Unless they make a different tee just for that purpose..

  • @1CHILOMAN
    @1CHILOMAN Před 6 lety

    This is the exact copy of the I manifold

  • @angelojed2196
    @angelojed2196 Před 2 lety +1

    Are they low loss fitting

    • @mjohnson6703
      @mjohnson6703 Před rokem

      I believe he said they are in the video.

  • @mercuryhvactechnic2530

    This is a only iPhone Use or Android phone tel me

  • @alicepet1994
    @alicepet1994 Před 5 lety

    I didn't see how you do refrigerant charge while the set is on.

    • @BKWhite07
      @BKWhite07 Před 5 lety

      😆😆 right. It'd be a tough task

    • @toddo.7819
      @toddo.7819 Před 5 lety +4

      Easiest way is with a valve core remover, know your tools 😉

    • @ericlarson8489
      @ericlarson8489 Před 4 lety +3

      Just get a T adapter

    • @TheRealoldcar
      @TheRealoldcar Před 4 lety

      Yes, use a tee adapter on the LP side, control the charge amount with a ball valve or you can also attach your manifold especially if you are using blends and need to attach a vaporizer, just one example. You will also find measure quick with these sensors a game changer.

  • @jonstebbins5115
    @jonstebbins5115 Před 2 lety

    You would have better reading if you closed the door on the condenser. Other than that nicely done.

  • @Captain_Kdawg
    @Captain_Kdawg Před 3 lety

    Dannng cool your not supposed to take pressure reading with that door off cat daddy !!!

  • @DrAtefman
    @DrAtefman Před rokem

    🤓Hi, it's a nice video and methodical, but don't forget to wear protective gloves and goggles for God's sake

  • @714chucky
    @714chucky Před rokem

    Great video! Friendly tip don’t suck your teeth when talking.

  • @frankl6684
    @frankl6684 Před 5 lety +1

    This system is nice in a lab. Try to use it in real life now with walls in the way. You will lose your indoor readings because the range on this system SUCKS. I have the sm460 system with the jl transmitter and by the time I get back to my manifold outside I loose the indoor readings. Don’t waste your $$$ on this stuff.

    • @MrBdogg317
      @MrBdogg317 Před 4 lety

      Frank L you don’t need the jl transmitter anymore. With the probes

    • @caligarcia87
      @caligarcia87 Před 4 lety

      @@MrBdogg317 how far can I use them

    • @Papasquatch73
      @Papasquatch73 Před 3 lety

      I used these with zero issues on a 2 story hotel. Range is great