Safe Isolation - Don’t FAIL Your AM2 or AM2S

Sdílet
Vložit
  • čas přidán 26. 07. 2024
  • During AM2 or AM2S or AM2E you will be expected to remove the cover of a 3 phase distribution board. It is important this is done correctly by asking for permission before staring the isolation procedure next all MCB's need turning off followed by the main switch. Many leaners when under the pressure of the end point assessment forget to isolate the main switch before removing the distribution cover.
    🔔 Subscribe for more free electrical training videos czcams.com/users/GSHElectrical?s...
    🔵 AM2, AM2S and AM2E Electrical Apprentices End Point Assessment Playlist
    • AM2, AM2S and AM2E Ele...
    == 🕐 Time Stamps - Cut to the action 🕕 ==
    00:00 - Removing the cover
    00:40 - Turn OFF all the MCBs
    00:55 - Fail the assessment
    01:11 - Locking off
    ➡️ NET - For the latest on AM2, AM2S and AM2E
    www.netservices.org.uk/
    Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
    You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical.
    ▶️ FACEBOOK / gshelectrical
    ▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
    ▶️ TWITTER / gsh_electrical
    ▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
    #GSHElectrical #Electricaltrainingvideos #am2 #electricalwiring

Komentáře • 11

  • @joannamaciejewska869
    @joannamaciejewska869 Před 3 měsíci +1

    Fantastic. Many thanks.

  • @sergiofernandez3725
    @sergiofernandez3725 Před rokem +2

    Great advice as always team eFixx

  • @aw5026
    @aw5026 Před 9 měsíci +1

    Good job

  • @djfs69
    @djfs69 Před rokem +2

    The difference of what you should do.
    I’ve never seen it done like that in the real world.

  • @asp217
    @asp217 Před 7 měsíci

    That isn't safe isolation as there could be exposed copper on the incoming side of that switch disconnector. I would isolate upstream of that DB as it is much safer. I can't tell you the amount of domestic CUs I have inspected where the installer had not terminated the line conductor properly and there is exposed copper to touch

  • @johnwaby4321
    @johnwaby4321 Před rokem +1

    And don't leave the pad lock keys lying around..keep them in your pocket 😮

  • @Lucas-rh8sw
    @Lucas-rh8sw Před 11 měsíci

    'Promo sm' 🤭

  • @montystelevision3238
    @montystelevision3238 Před 9 měsíci

    If people are failing on this rudimentary school boy stuff, I assume they all failed their driving tests by neglecting to put in their seat belts 😖

    • @carlnash5736
      @carlnash5736 Před 7 měsíci

      Under pressure most people will not be able to concentrate Mr perfect parallel park.