Motor Control Circuit with Trip Auto Start and time Delay | Logic Control Wiring Class 6

Sdílet
Vložit
  • čas přidán 21. 08. 2024
  • Electrical Logic Control Wiring Class - 6
    In this video, we will learn how to make a circuit diagram for two motor to make than ON & OFF by using a Float Switch and Selector Switch and we will use Time delay in Overload trip to make the second motor Auto Start when first motor trip
    Logic Used in this Video
    ✅ 2 water pump motor
    ✅ auto manual selector switch Connection
    ✅ Float Switch Connection
    ✅ motor selection for pump by using selector Switch
    ✅ interlocking of contactors
    ✅ Second motor ON when Running motor TRIP
    Thank You
    Electrical Technician
    Electricaltechnician02@gmail.com
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    My gadgets for CZcams 📺
    Camera 📸 For video Recording
    amzn.to/3z3W9XM
    Mic 🎤 For Sound Recording
    amzn.to/3kpUyaK
    My Laptop For Video Editing
    amzn.to/3imBuqU
    Tripod Stand
    amzn.to/3BajZmn
    Overhead Stand For Recording
    amzn.to/3z1rzhm
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    Some Electrical Product For Your Home
    Programmable Daily/Weekly Digital Timer
    amzn.to/3z4tBgF
    Wifi Control Smart Plug top
    amzn.to/3dAZrJA
    amzn.to/3hcO6Sr
    Multimeter for electrician
    best - amzn.to/3w7Vbry
    Low Price - amzn.to/3wfF1MC
    Water Level Controller
    Single Tank - amzn.to/3xdcrwY
    Double Tank - amzn.to/2UnvJAX
    Motor Starter
    2 HP Motor Starter - amzn.to/366AlhL
    2 HP Motor Starter - amzn.to/3xhVtxw
    Toolkit For Electrician
    amzn.to/3AmK1T5
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    Download PDF from telegram Channel
    telegram.dog/El...
    👉 Follow us on Facebook :-
    / electricaltechnical
    ══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
    Related Video Which you must watch
    How Float Switch Work
    • Float Switch कैसे पानी...
    Electrical Logic Control Wiring Class 1
    • Motor Auto Start And N...
    Electrical Logic Control Wiring Class 2
    • Motor OFF By Using Tim...
    Electrical Logic Control Wiring Class 3
    • Timer Auto Reset Conne...
    Electrical Logic Control Wiring Class 4
    • Motor Starter With Sel...
    Electrical Logic Control Wiring Class 5
    • Motor On & OFF by Usin...
    All Video of Electrical Logic Control Wiring 👇👇👇
    • Logic Control Wiring
    All Video of Electrical Drawing 👇👇👇
    • Electrical Drawing in ...
    #wiring
    #electricalDrawing
    #class6
    #logicControl
    Keyword for this Video
    Electrical Circuit Diagram
    circuit diagram of logic
    how to read schematic diagrams
    electrical wiring class 6
    how to read schematic diagrams hvac
    how to read schematic diagrams pdf
    electrical drawing kaise samjhe
    how to read electrical drawing
    electric drawing
    motor starter connection
    dol starter
    motor starter

Komentáře • 46

  • @syedhassanali9330
    @syedhassanali9330 Před 7 měsíci +1

    Thank you very much sir very informative video

  • @gowthampavanaskar1889
    @gowthampavanaskar1889 Před 3 lety +1

    Very Good 👌👌

  • @HarishChandra-ex8vw
    @HarishChandra-ex8vw Před 3 lety

    All types of video bana liya,ek video transformer ke bare me banaye sir

  • @kishansingh4103
    @kishansingh4103 Před rokem

    Sir your video is vary nice
    Sir dc induction ke upper ek video banao

  • @manojkuaarkushwaha
    @manojkuaarkushwaha Před 2 lety

    👍 Electrical components agar khrab ho jaye to unko repair kr sakte hai agar nhi to kya kya kr sakte hai.

  • @satyadeosingh3684
    @satyadeosingh3684 Před 10 měsíci

    Thanks.

  • @shahidakhtar9756
    @shahidakhtar9756 Před 3 lety

    single timer hone se circuit thoda complex ho gaya hai but bahot Sahi video hai sir Ji mere bahot se concept clear ho gaye
    thank you very much, sir. Huge compliment for you're effort sir really appreciate you're hard work

    • @ElectricalTechnician
      @ElectricalTechnician  Před 3 lety

      Isi liye two timer ka use kar ke pahle explain kar diya tha
      By the way thanks 😊

  • @vaibhavdjgaming8044
    @vaibhavdjgaming8044 Před 3 lety

    Jay Maharashtra

  • @yellamgopi6172
    @yellamgopi6172 Před rokem

    Hi..brother...
    In the end of this video you explained aux-2 relay is turn On and NC becomes NO ,then how motor-1 runs

  • @AJAYKUMAR-pw1uk
    @AJAYKUMAR-pw1uk Před 3 lety

    Sar is per video jarur banaye please sir

  • @manojkuaarkushwaha
    @manojkuaarkushwaha Před 2 lety

    Electrical panel me ACB ke sath tripping circuits explain kre

  • @musarazabakaralijalali1720

    Thanks sir ji 🙏

  • @khalidraja7127
    @khalidraja7127 Před 3 lety

    Sir aaj ka mera sawal hai?
    2 Building hai aur do he ATS hai aur ek generator hai. Inka control circuit banana hai
    (1) Building no 1 ke supply line cut ho jaaye to generator on ho jaaye
    (2) Isi tarah building number 2 ki supply line cut ho jaaye to be generator on ho jaaye
    (3) Jab to donow building ki supply line cut jaaye to generator fir bhi on ho jaaye
    (4) Power supply transformer elada elada hai.
    Please yah circuit jarur banega
    Thanks. Love from Pakistan 🇵🇰🇵🇰

  • @SJ-op6wc
    @SJ-op6wc Před 3 lety

    Sir plz Forward reverse automatic contractor ka control and power wiring ka video banao sir plzz

  • @manzooryatooyatoo3570
    @manzooryatooyatoo3570 Před 3 lety

    Very nice

  • @fromhome9186
    @fromhome9186 Před 3 lety

    Time ke sath

  • @chanakyadinesh
    @chanakyadinesh Před 3 lety +2

    Thanks sir but, I would like to know which software is this? Expecting your good response sir.

  • @mahadevmandal681
    @mahadevmandal681 Před rokem

    Distribution panel ka video house wiring ke liye PDF ke sath aur Kaya kya lagana chahiye,kitne amp ka lagana chahiye .
    Plzz ek video banaye Bhai atyant abasyak hai plzz answer dena main app ka aavari rahunga.Plzzz.....

  • @hrhorrorgamer078
    @hrhorrorgamer078 Před 6 měsíci

    Sir star delta Wale motor ko reverse forward karen

  • @ankitsinhchauhan2559
    @ankitsinhchauhan2559 Před rokem

    Timer ke sath banaye

  • @electro-mechanic2906
    @electro-mechanic2906 Před 2 lety

    Sir (Semi star delta ka control wiring) kijie please

  • @user-to8sq4fh2d
    @user-to8sq4fh2d Před 9 měsíci

    Contactor ko jalne se rokane ke liye kya kiya jaaye

  • @ranjeetprasadpaswan103

    Sir...... Ji
    CT K uper koi video banaye Sir......
    Jaise ki
    CT ka
    Class kya hota hai
    Class accha kon sa hota hai
    Kabhi CT purchase karne jata hun to
    Bahut confused ho jata hun... Dukandar
    Ye accha
    Koi dukan wala dusra kuch bolta hai.. Plz
    CT K upper kuch gyan dijye

  • @jagarnathyadav8768
    @jagarnathyadav8768 Před 3 lety

    Sir Namaste 🙏 main nepal se hu mere liye v ek video banadijiye, industry me single phasing ho to alarm baje, koi v phase me problem ho toh alarm baje

  • @mitubarik3361
    @mitubarik3361 Před 2 lety

    Sir jo aux 2ka nc no use kiahai uske jagha hum k1 ka nc and k2 ka nc use kar sakte hai kya?

  • @AJAYKUMAR-pw1uk
    @AJAYKUMAR-pw1uk Před 3 lety

    Sar auto forward , reverse starter mein motor connection is prakar se ho ki motor ekadam se Na rivers Ho Na kadam forward Ho kuchh samay ke liye hold hokar reverse forward Ho sarasi video banaya kar dikhaiye please sir motor reverse forward ekadam hogi to uski Puli per asar padega jisse motor per or gearbox per dikkat hogi isliye sar usmein kuchh hold time ho aisi video banaen please sar

  • @ashishswain3567
    @ashishswain3567 Před 3 lety

    sir ye konsa softwer he...

  • @linettefletcher5164
    @linettefletcher5164 Před 3 lety

    vae.fyi
    gratifying

  • @gowthampavanaskar1889
    @gowthampavanaskar1889 Před 3 lety

    Hi,
    If we reset the First motor Fault while Motor 2 is in running, then motor 2 will switch off, because selector switch is kept in position 1, so circuit is incomplete. If we want Motor 2 to be running ,then need to change the selector switch position to Motor 2, this makes the circuit complete and motor won't switch off.
    Please correct me if a am wrong.
    Can we hold the current motor running circuit after the fault reset, without changing the selector switch?

    • @ElectricalTechnician
      @ElectricalTechnician  Před 3 lety

      Circuit will be continued.......

    • @ElectricalTechnician
      @ElectricalTechnician  Před 3 lety

      Yes in the circuit in which i have used two timer in that Circuit when we reset the overload relay the motor will turn off
      But in one Timer Circuit i have solve that problem watch the video till end

    • @gowthampavanaskar1889
      @gowthampavanaskar1889 Před 3 lety +1

      @@ElectricalTechnician In Single Timer circuit,
      During the Motor M1 Over Load Relay Trip, Motor M2 will switch ON but it will ON and OFF continuesly because when Motor M2 is ON, Aux 2 Relay NC will become NO which was holding the Motor M2. This will break the circuit and Motor M2 will turn OFF. Again Aux 2 NO will be NC and Motor M2 will turn ON and this will continue . This means Motor will switch ON & OFF continuesly.
      During the Motor M2 Over Load trip, this is also the same Situation where Motor M1 wil ON and OFF continuesly because when Motor 2 OLR trip, M2 Contactor NC contact will turn into NO, powering up the Aux 2 Relay . This will convert Aux relay NC contact to NO of motor M1 , thus motor will turn OFF. During this time Aux relay will switch on and off due to M2 NC.
      This will make M1 to ON and OFF continuesly.
      So while Motor is switching due to OLR trip, The motors will not be continuesly ON. For this problem need solution.
      Also we cannot hold the same motor circuit ,after OLR trip reset even in single timer circuit. While resetting the olr, even running motor will switch OFF.

    • @ElectricalTechnician
      @ElectricalTechnician  Před 3 lety +1

      Good analysis keep it up all the problems will save in the next video

    • @gowthampavanaskar1889
      @gowthampavanaskar1889 Před 3 lety

      @@ElectricalTechnician Thank you ji.. All your videos are excellent and we get to learn lot of things especially in control circuits wiring..👌🙏🙏

  • @brajendrasingh2226
    @brajendrasingh2226 Před 2 lety

    Sir offline nahi sikhate ho

  • @marlockflein1287
    @marlockflein1287 Před 3 lety

    it`s wrong,you have to review something,when you add tha aux 2,it never changes,it always stays the same because of that it is incorrec for me,thanks.

  • @pazhmalai
    @pazhmalai Před rokem

    Pls 3xplain in english bro or just tell Conditions in english

  • @gauravchaudhari9689
    @gauravchaudhari9689 Před 2 lety

    Background music band karo plz ..