How to wire a distribution board with two neutral rails - tutorial (South Africa)

Sdílet
Vložit
  • čas přidán 24. 07. 2024
  • How to wire a distribution board with two neutral rails - tutorial

Komentáře • 89

  • @alexwonner7469
    @alexwonner7469 Před 2 lety +7

    Could spend the all day watching your tutorials... not an electrician and won’t venture there but it’s simply so interesting and at last I do understand something...

  • @phalengholdings8239
    @phalengholdings8239 Před 3 lety +7

    This guy is very clever, I normally put earth leakage just after double pole circuit breaker then put my bridges the other way round but I make sure that my lights are not under earth leakage,,,,,,, ur explanations are so useful bro

  • @zzvannie
    @zzvannie Před 2 lety +8

    Wow I always thought the db boards were so complicated but your video makes everything so simple to understand. Thank you!!!

  • @jeremiegibangokantin1941

    so genius, born to teach …you have gained all my respect sir

  • @eastomega
    @eastomega Před rokem +2

    this channel has helped me a lot , I wish I had enough to buy you a drink every time you teach😊

  • @glendagorogokunia9442
    @glendagorogokunia9442 Před rokem +2

    Best explanation and tutorial.. Straight Outer from Papua New Guinea 🙏💥

  • @dmr9042
    @dmr9042 Před 3 lety +4

    if you are a teacher, I will not hesitate to go to school. you explain so well. Thanks fr sharing the skill. highly appreciated.

  • @danielfadd
    @danielfadd Před 2 lety +6

    You do realize that you were born to teach other's -dont you? Top class tutoring,straight to the point with no confusing bs and just very easy to follow while being very informative and interesting .Nothing but respect and gratitude my fellow South African..Kwaai lappies my Broer .☺

  • @PanjiThame
    @PanjiThame Před rokem +2

    Excellent video. I learn from your technique and i will apply it. Keep up your good job sir. Thanks.

  • @paddajunior744
    @paddajunior744 Před 3 lety +7

    This gent really explains things so nicely, for anyone to understand. Thank you for such informative topics.

  • @ThembaVundla-iu3ug
    @ThembaVundla-iu3ug Před rokem +1

    Oh how I love these tutorials❤️❤️ please loop a 3 phase db board, very much informative sir.

  • @SnowyPe
    @SnowyPe Před 3 lety +2

    Great explanation..100% understand what to do now wiring a db board to an inverter supply

  • @maximumrespect1997
    @maximumrespect1997 Před 2 lety +3

    Excellent..... thank you sir.....very informative and deadly accuracy.

  • @roderickjohnson1677
    @roderickjohnson1677 Před rokem

    This is how I was been trained on distribution boards 9 out of 10 score for you Mr electrician

  • @roryfreeman9433
    @roryfreeman9433 Před 3 lety +3

    That double green lever switch is an isolator and can not trip on short circuit or over load. The white and green of the earth leakage switch on the other hand is an isolator, short circuit and overload protection as well as earth leakage protection.

  • @stevensseagull
    @stevensseagull Před 3 lety +6

    Thank you for the quality of your content, truly amazing. Best South African DIY channel I've ever seen, didn't know we got such here!

  • @entlungwini2570
    @entlungwini2570 Před 2 lety +2

    Teach me teacher!!!, great lecture thank you sir 🙌👌👍

  • @mapoletswele8174
    @mapoletswele8174 Před 2 lety +1

    Great demonstration, thank you 🙏🏿🙏🏿🙏🏿.

  • @wilsonokibe8431
    @wilsonokibe8431 Před 2 lety +1

    I just learned what seems so difficult like an easy task. God bless you real good. This task is amazing. I trust that God will continue to use you to educate minds and prevent hazards. From this lesson, I can carefully examine a DB and wire a building. I believe so. But the issue now is how to handle multiple plugs or lights. Hope to find another link.

    • @thee_crocodile3270
      @thee_crocodile3270 Před rokem

      You need to bond you need a fish line you need a multimeter yes

  • @ndlovubhekimpilo7619
    @ndlovubhekimpilo7619 Před 3 lety +1

    All answered wonderful explanations

  • @FynbosGarden
    @FynbosGarden Před 3 lety +1

    crystal clear. man is a credit to CZcams

  • @thulanijohn620
    @thulanijohn620 Před 3 lety +1

    Thank you so much Sir.
    Please assist me also on 3phase New DB
    Thanks you are a life saver

  • @QuestionHartmann
    @QuestionHartmann Před 2 lety +1

    Nice demonstration!

  • @user-cz2fp7pt7q
    @user-cz2fp7pt7q Před 3 měsíci

    Thank you sir. I appreciate

  • @tshepomashabelangatane7960

    im perfect now. thanks for detailed info

  • @jmunshi
    @jmunshi Před 2 lety +3

    Great video, very well explained.
    How does one identify the neutral wire for a circuit once the db board is complete should there be a need to move circuits to EL or direct supply?

  • @BERichProjects
    @BERichProjects Před 3 lety +2

    Thanx for the info. It helps alot. Can u tell me what size breaker I shoud install for a borehole pump and if it should be wired to an earth leakage breaker. Thanx

  • @sivapillay8206
    @sivapillay8206 Před 3 lety +2

    In detail and understanding.

  • @nathimngadi764
    @nathimngadi764 Před 3 lety +1

    One of the best videos in south africa thank you very much 💙💚💜💜🧡 🤍🖤 l wish one day you can teach us about lights using contactors single phase

  • @Admimistrator
    @Admimistrator Před 3 lety +1

    Great explanation on how this works.

  • @isaacbusinge7509
    @isaacbusinge7509 Před rokem +1

    Sincerely there are mistakes I have been making but am gonna correct them now🤝👏

    • @ecologicaltime
      @ecologicaltime  Před rokem

      thank you. Please just note that the main breaker must have over current protection. See example here: czcams.com/video/VHyFl-y7XCA/video.html

  • @isaacngigi4946
    @isaacngigi4946 Před 2 lety

    informative.. educative i like it

  • @martinkotze7258
    @martinkotze7258 Před rokem

    Thanks very much, your video's have helped me a lot so far.
    What will happen if I put everything on earth leakage? Putting some stuff not on it will complicate things too much because I'm planning 2 rows of modules: top row for ONLY Escom, and bottom row for EITHER Escom OR Inverter via change over switch. (The bottom row will have its own neutral bar.)
    Furthermore, do I have to have 2-pole breakers (L+N) that lead to subpanels in my lapa and garage? The subpanels have their own L+N main switches.

  • @denzelm1000
    @denzelm1000 Před 3 lety +1

    Great explanation

  • @mysteriousgamer4463
    @mysteriousgamer4463 Před 3 lety +1

    Thanks for the info.

  • @Collinnaidoo5276
    @Collinnaidoo5276 Před 5 měsíci

    Hi thank you for the video its very informative. I have a question can i use a 4mm wire for a 20 amp breaker for my gyser. My gyser has a 30amp breaker now it has to be replaced. Thanks

  • @littlepeoplesmontessoripre5564

    very informative

  • @musasamatheus1726
    @musasamatheus1726 Před 3 lety +1

    It help alot... thanks

  • @clementbanda9775
    @clementbanda9775 Před rokem

    Thanks for your help me

  • @maxhofmann6993
    @maxhofmann6993 Před 5 měsíci

    I just recently upgraded my geyser element to 4000W and had to upgrade the breaker as well. My db still uses the old breakers and I discovered my geysers breaker had an in built isolater switch. However my geyser has an isolater in the roof about a meter away from it. Was it illegal for me to change the setup?

  • @BartholomewOpara
    @BartholomewOpara Před 2 měsíci

    Yes Thank you 😊

  • @JohnAlexanderramboparyjrthe3rd

    Can all 2 pol breakers be used for live and neutral ? Iv got a 2 pol 100Amp main switch and I’m a bit confused as many people
    Say you don’t put them both into the same breaker but in that case what’s the piont of 2 pols?

  • @joziboy8673
    @joziboy8673 Před rokem

    Can one use 2 single pole MCBs instead of a double pole main circuit breaker? I have a old jhb house with a faulty 80amp main supply cb and cannot get a 2p 80amp mains breaker, i can only find 2 80amp single pole breakers.
    Most houses are 63 amps can one step down to a 63amp supply from the original 80amps or does one need to keep the 80 amp breaker in place?

  • @skunkle100
    @skunkle100 Před 3 lety +1

    good, thanks

  • @ASHRAFALI-br7iq
    @ASHRAFALI-br7iq Před 3 lety +1

    Thank you

  • @mooningrelaxation5480
    @mooningrelaxation5480 Před 3 lety +1

    very nice

  • @TrevorKhathi-gu1tu
    @TrevorKhathi-gu1tu Před 28 dny

    Thank u sir🙏

  • @thabisomodisane1435
    @thabisomodisane1435 Před rokem

    Is it wrong if i install everything in sequence double pole breaker next to it earth leakeage breaker then stove geyser and other loads?

  • @zubairally7625
    @zubairally7625 Před 3 lety

    Could you do a 3 lever switch to 3 lights...please

  • @trentjoel7901
    @trentjoel7901 Před 9 měsíci +1

    Good

  • @lechzekjacobs2752
    @lechzekjacobs2752 Před 3 lety

    Great video, very well explained. I had no idea that added neutral bar fits perfectly into a samite rail. I've always just screwed them to the board. A quick glance at your main switch seems to indicate that it's an isolator (2 green toggles = no overload protection) instead of a circuit breaker (white + green = overload protection) in which case, your main switch won't trip on a fault. I suppose you were just using it for illustrative purposes?

    • @ecologicaltime
      @ecologicaltime  Před 3 lety +1

      I have contacted CBI and they confirmed the details on their website was wrong. Many merchants have wrong details: 1drv.ms/b/s!AnwSVs2Nl8dGltpb9pAEsawaRr5ekg?e=BFxVk8
      Will have to fix this video

    • @ecologicaltime
      @ecologicaltime  Před 3 lety +1

      The lab had the wrong stock, will redo this video. thanks for your comment.

    • @lechzekjacobs2752
      @lechzekjacobs2752 Před 3 lety +1

      Happy to help

  • @mirriamsinkala2644
    @mirriamsinkala2644 Před 10 měsíci

    In place of a earth leakage , can we use a lightening arrester

  • @michaelcostello6991
    @michaelcostello6991 Před 3 lety +1

    This was really helpfull. Thank you

  • @gaminggaminglast2723
    @gaminggaminglast2723 Před 3 lety

    What is better
    Earth leakage protection breaker
    Or
    Rccb

  • @bonganimokoena8328
    @bonganimokoena8328 Před rokem

    What's the again of not protecting the lights?

  • @ashwinshadygold6277
    @ashwinshadygold6277 Před 2 lety

    I'm using new brain cells thanks man ....can you wire a Sam surge protector please

  • @mkululigqamane4252
    @mkululigqamane4252 Před 3 lety +1

    👏👏👏

  • @Choosen87
    @Choosen87 Před 3 lety

    Nice stuff bro ! Please explain how when any switch is down you say it's open? Is because it's not connected to make it a full circuit?

  • @lesibanahopekolobe2292
    @lesibanahopekolobe2292 Před 3 lety +2

    Nice Content 🚀👍
    Quick question, where can I get the specifications of cable sizes and current carrying capacity? 🇿🇦

    • @ecologicaltime
      @ecologicaltime  Před 3 lety +1

      Thank you. Cable manufacturers specify these things. The only issue is current spec changes depending on how the cable is run. www.cse-distributors.co.uk/cable/technical-tables-useful-info/table-4e1a/
      Generally its: 1mm=14A; 1.5mm=19A; 2.5mm=26A; 4mm=35A

    • @lesibanahopekolobe2292
      @lesibanahopekolobe2292 Před 3 lety +1

      @@ecologicaltime Thank you for the update 🙂 keep going strong 🇿🇦🚀

  • @ridoois6698
    @ridoois6698 Před 2 lety

    When do we have to bond neutral and earth?

  • @luckyboysen5169
    @luckyboysen5169 Před 2 lety +1

    Super

  • @thandekamalaba2301
    @thandekamalaba2301 Před rokem

    Great

  • @elishatech4600
    @elishatech4600 Před 3 lety +1

    Here in Zambia the Neutral Wire and Earth Wire are Connected together for bonding purpose. Is that correct Or a mistake?

    • @ecologicaltime
      @ecologicaltime  Před 3 lety +1

      the Neutral is also there to assist with protection. It depends where in the system they are bonded.

    • @elishatech4600
      @elishatech4600 Před 3 lety

      Thanks.

  • @langarock5883
    @langarock5883 Před 2 lety

    Please sir tell me why did you put earth leakage among breakers

  • @brightsideofsaturn
    @brightsideofsaturn Před 3 lety

    What is this db board used for

    • @ecologicaltime
      @ecologicaltime  Před 3 lety

      teaching students. You can use this for outbuildings and small homes

  • @leonfroos
    @leonfroos Před 3 lety

    Wrong main switch. It doesn’t have overload protection . 5.3.5

    • @ecologicaltime
      @ecologicaltime  Před 3 lety

      Thanks. But this one is listed as having overload and short circuit protection: www.voltex.co.za/product/cbi-isolator-63a-2pole-3ka-qal20063/ I think they have the wrong details for this isolator. Will have to change the video.

    • @ecologicaltime
      @ecologicaltime  Před 3 lety

      the video is being filmed again. New one to be uploaded. thank you

    • @leonfroos
      @leonfroos Před 3 lety

      Yes must be a mistake. I work for the electrical inspection body. Here to help

  • @cyruskidstvgamesshow2967

    Thank you