3 Phase Capacitor calculation

Sdílet
Vložit
  • čas přidán 4. 03. 2022
  • Dear Viewers,
    In this video, i described capacitor bank calculation.
    Harish sharma
  • Věda a technologie

Komentáře • 69

  • @parveenpanchal5608
    @parveenpanchal5608 Před 2 lety +2

    Very detailed information, Thanks for such good video.

  • @kamlakarnaik8806
    @kamlakarnaik8806 Před rokem

    Excellent 👍 HAT'S OFF 🙏SIR

  • @IndrajeetPatel-j7f
    @IndrajeetPatel-j7f Před 2 dny

    Sir mere karkhane me 2kw load ka 3 phase capacitor bank laga hai jiska ampere 2.78 hona chahiye lekin ab check karne per 1.4 aa raha hai isase kya fark padega
    Kya isase fuse kat sakta hai

  • @abhaybajpai8898
    @abhaybajpai8898 Před 9 měsíci

    Shandar 😊

  • @sarikajeswal6016
    @sarikajeswal6016 Před rokem

    बहुत खूब 🥰🥰🥰🥰🥰🥰

  • @pinku5940
    @pinku5940 Před rokem

    Gajab sir main pura clear ho gaya thank!

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem

      Tup clear ho gaye ya tumhara funda?
      Ok just joking thanks for watching my videos.

  • @sabirhussain3385
    @sabirhussain3385 Před rokem

    Thanks 🙏 sir

  • @satendrajaat657
    @satendrajaat657 Před 2 lety

    Good sir 👍

  • @vipulpanchal9852
    @vipulpanchal9852 Před 5 měsíci

    Sir mera 10hp moter 1400 rpm three phase hai to muje kitne kvar ka capacitor lagana hoga

  • @satendrasharma9069
    @satendrasharma9069 Před 2 lety

    Pranaam karta hu sir jis junoon k saath aap teaching karte hain

  • @kubercontrols7562
    @kubercontrols7562 Před rokem

    Nice explanation sir ji.kindly make video on cable calculations.

  • @gunvantgotmare7515
    @gunvantgotmare7515 Před 7 měsíci

    Thank you sir

  • @sartajsingh7301
    @sartajsingh7301 Před 11 měsíci

    How to determine of substation. kWh se nikaale kya ? I mean jitna kWh hoga utna kw multiplication kre.

  • @adeshkumar199
    @adeshkumar199 Před 11 měsíci

    Sir ji Namaste🙏.
    mere yha par 800 kw load chal rha h. Aur P. F= 0.996 chal rha h. Isme 575kvar capacitor bank laga h. Muje apna p.f 1 karna h. Aur kitna kvar add karna padega.

    • @BuildingSanchalan
      @BuildingSanchalan  Před 11 měsíci +1

      No need to add KVAR only set your APFCR. And .996 is treated like 01.

  • @sopandagalbaj5002
    @sopandagalbaj5002 Před 2 měsíci

    Sir Transfarmer 1500kw kahai aur load 1600kw ka hai to capicitar kitneka lagega

  • @premvigneshappiya9583
    @premvigneshappiya9583 Před 2 lety

    Hi Sir, I watch all your videos it's really interesting and informative. Could you please clarify that the load value 4850kw is included all types of load (resistive+cap+inductive) or only inductive load we need to consider?

    • @BuildingSanchalan
      @BuildingSanchalan  Před 2 lety

      Connected load

    • @premvigneshappiya9583
      @premvigneshappiya9583 Před 2 lety

      Hi Sir, Thank you for your reply. But still I didn't get clarity. In general capacitor bank is making newly against only considering inductive and capacitor load or including resistive load? Please clarify sir..

    • @BuildingSanchalan
      @BuildingSanchalan  Před 2 lety

      @@premvigneshappiya9583 Dear thanks for watching my videos,
      Connected load of a building is always any type of electricity load ,doesn't matter it is resistivity, capacitive or inductive.

    • @premvigneshappiya9583
      @premvigneshappiya9583 Před 2 lety

      @@BuildingSanchalan OK sir.. Understood.. Thank you..

    • @BuildingSanchalan
      @BuildingSanchalan  Před 2 lety

      @@premvigneshappiya9583 मोस्टली यह लोड उतना ही होता है जितना बिजली का कनेक्शन लेते हैं

  • @hengineeringmind9871
    @hengineeringmind9871 Před 2 lety

    Sir 50 Questions M.S.T. Interview ke liye banaiye na

  • @shyamjeetyadav2305
    @shyamjeetyadav2305 Před rokem

    1125kw ki sleepring motor ko kitna kvar lgega

    • @BuildingSanchalan
      @BuildingSanchalan  Před 11 měsíci

      Power capacitor ke liye motor ke type ki jarurat ni hoti. tum 1125 kw per calculate karo.

  • @ramgopal-ex1uf
    @ramgopal-ex1uf Před rokem

    Sir very nice
    Please tell that how much energy store a capaciter

  • @dineshgohil4784
    @dineshgohil4784 Před 2 lety

    CT PT meter related ,MF,HT conection related, videos plz exam in meter testar Pgvcl

  • @mukeshkumaryadav-dn1xt

    Dear sir HT Dg hota he kiya, agr hota he to sir please make video

  • @premshilakushwaha1683

    7.5 hp 1440 RPM motar me kitana kvar lagana parega

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem

      3 phase capacitor= 4.3 KVAR, if u select 1 phase then = 4.3/3=1.4 kvar each phase.

    • @beatboy9392
      @beatboy9392 Před 3 měsíci

      Sir ji 🙏 m Panipat Haryana se hu maine 10hp ki three phase motor (7.5kw) ki motor h jiska (pf 0.85) h or mujhe ye nhi pta k (pf.0.99 ) kaise ho sakta hai h sir btaye kitne kvar Ka capacitor lagana pdega 🙏 sir reply fastley

  • @hengineeringmind1647
    @hengineeringmind1647 Před rokem

    Sir ji DB and SDB me kiya Antar Hai

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem

      DB= distribution board
      SDB= sub distribution board

    • @hengineeringmind1647
      @hengineeringmind1647 Před rokem

      @@BuildingSanchalan Kaun Sa Kaha pr use HOTA hai

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem +2

      @@hengineeringmind1647 according to use, jese three phase k liye DB aur single phase distribution k liye SDB

  • @AshishSingh-zo6qm
    @AshishSingh-zo6qm Před 7 měsíci

    Three phase 7.5hp 960 rpm
    Connection 6kw
    Power factor 0.788 aur 4kvar ka capicitor lagane ke bad bhi power factor 0.788
    Sir kitne kvar ka capicitor lagaye ki pf 0.99 ho jaye

    • @BuildingSanchalan
      @BuildingSanchalan  Před 7 měsíci

      4 KVAR ka 3 phase capacitor is OK not single phase please check.

    • @BuildingSanchalan
      @BuildingSanchalan  Před 7 měsíci

      if you ask the shopkeeper then ask 7.1 KVA or 4 KVAR

  • @pawansarswat5662
    @pawansarswat5662 Před rokem

    Sharma ji थ्री फेज कनेक्शन ह लेकिन बिल्डिंग में सिंगल फेज उपकरण अलग-अलग लोड दिया जा रहा है तीनों फिजो में सामान लोड कभी कभी नहीं रहता है, ट्रांसफार्मर में 30 एंपियर की एमसीबी लगी हुई वह कभी कभी गिर जाती है , कृपया यह बताएं कि पावर फैक्टर सिंगल फेज में अलग-अलग लगेगा ,या थ्री फेस में? Total load=30 AMP ह तो पावर फैक्टर कितने का लगेगा?🙏🙏 मार्गदर्शन जरुर देवें 🙏

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem

      single phase upkaran ke liye power factor ki jarurat ni padti kyonki aajkal single phase upkaran rasistive ya capacitive ha. yadi tum alag alag lagana chahte ho to single phase lagega.

  • @dineshlamrod9484
    @dineshlamrod9484 Před 8 měsíci

    3 face 52 h.p. par kitna lagega

  • @ASHOKSHARMA-nl1zx
    @ASHOKSHARMA-nl1zx Před 10 měsíci

    सर इसका कोई थंब रूल भी होता है

  • @GauravKumar-bb3ts
    @GauravKumar-bb3ts Před rokem

    Sir capacitor Bank ka connection digram bato kese connect hota hai load me please sir

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem +1

      will try

    • @GauravKumar-bb3ts
      @GauravKumar-bb3ts Před rokem

      @@BuildingSanchalan thank sir g

    • @sartajsingh7301
      @sartajsingh7301 Před 11 měsíci

      Sir substation mei three phase connection kaise kare. And mathematical kaise calculate kare kitne cap. Lgane honge 3 phases mei. Sab phases mei same rehte hai but kitne kre connect. kWh se nikale kya ?

  • @balchandgendale344
    @balchandgendale344 Před rokem

    Sir ji apko PTA nhi hai ki dg me power bank ka use nhi kia jata hai.

    • @BuildingSanchalan
      @BuildingSanchalan  Před rokem

      Dost, HT generator per kiya jaata h jab bulk generation hota h.
      Thanks for commenting me.

  • @hengineeringmind9871
    @hengineeringmind9871 Před 2 lety

    Taki Jo M.S.T.hai wah Supervisor Bansake