DIGITEN DFC15 FLOW LIQUID CONTROLLER OPERATION VIDEO

Sdílet
Vložit
  • čas přidán 22. 01. 2019
  • Set K value, Quantitative, change volume unit, change temperature unit, run stop

Komentáře • 39

  • @xsuala
    @xsuala Před 4 lety +2

    how do you determine the right k value? do you have to constantly be calibrating it?

  • @HawkeyesClub
    @HawkeyesClub Před 4 lety +1

    Can this be connected to a float switch? I need a controller that has a manual run/stop button but can also be connected to a float switch so it automatically stops the flow when water reaches a certain level in my container.

  • @mattwanasek6660
    @mattwanasek6660 Před 4 lety

    will the seals hold up to hot water, strait from a hot water heater?

  • @l.kupczyk8681
    @l.kupczyk8681 Před 4 lety

    Can I set a date and time when it shuld fill up my tank ?

  • @mathewjacob8527
    @mathewjacob8527 Před 3 lety

    Does it measure Imp.gallons or US Gallons

  • @fagan316
    @fagan316 Před 5 lety

    This product looks awesome.....
    Quick question once I set it to flow 300 gallons, when its done do I have to set 300 every time I want to use it or do I just hit run? Will I have to program it every time the power goes out or is the information stored?

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      The setting value will be stored when power off, You only press the RUN/STOP button to deliver 300 gallons automatically.

  • @mcreixell1
    @mcreixell1 Před 5 lety

    Does someone know if the sensor and solenoid valve can withstand use with corrosive liquids? Thanks!

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      In general, some sensor and solenoid valve work with the liquid of weak acid and weak salt.

  • @therealMFfeelyaheard
    @therealMFfeelyaheard Před 3 lety

    Hello I have been using these now a couple years. I think they are great. But now I have an issue where one of my units is not measuring any water flow. I need help please. I cannot call the number from the USA - is there a manual or do you have an answer? I replaced the plug. I replaced the flow sensor. It worked briefly but now all numbers are 0. When water runs through it it does not sense any flow at all.

  • @yadiraserrano8142
    @yadiraserrano8142 Před 4 lety

    the flow of my system is throttled when I occupy the controller. Does the K have something to do? I already changed the valve and nothing ..

    • @digitenvictor1532
      @digitenvictor1532  Před 4 lety

      K value is different for different flowmeters, if you have any questions, please contact us with email: service@digit-en.com

  • @marcosalamino9192
    @marcosalamino9192 Před 22 hodinami +1

    E possível definir vazão em litros por minuto?

  • @therealMFfeelyaheard
    @therealMFfeelyaheard Před 5 lety

    For some reason my unit ( I use gallons instead of liters) is off by a value place. 5.00 gallons is half a gallon 50.00 is 5 gallons 500.00 is 50 gallons and etc. is there a fix for this?

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      Hi, what is your flow sensor? I think you need to increase the K value according to your description.

    • @therealMFfeelyaheard
      @therealMFfeelyaheard Před 5 lety

      DIGITEN Victor thank you for the quick response. I purchased 5 dc15 units for my business. I would greatly appreciate some detailed instructions on how to adjust the k value and calibrate. I have large tanks I fill with these units and so far I love the product. I have filled a 200 gallon tank. I have to enter 2000.00 to do so. It is very close but delivered about 180 gallons when I entered 2000.00 - I pressed the up and down buttons simultaneously to change to gallons successfully. I would like to be able to enter 0200.00 for 200 gallons and it deliver the 200 at least closer to it. Right on spot would be great too. Thank you

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      Hi @@therealMFfeelyaheard​, You can reduce the K value by 10 times(may be 9 times).

    • @therealMFfeelyaheard
      @therealMFfeelyaheard Před 5 lety

      DIGITEN Victor my current k value is 1.98 which is what it came at so 9.00 ? I filled 300 gallons last night (entered 3000.00) and the system delivered 275 gallons. So does the k value at 0009.00 sound about right ?

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      Please contact DIGITEN customer service, thanks@@therealMFfeelyaheard

  • @ivanzinho1995
    @ivanzinho1995 Před 4 lety +1

    what is the thread of the temperature sensor?
    what is the thread of the temperature sensor?

  • @WeitangChen110
    @WeitangChen110 Před 5 lety

    Hi, can I connect more than one water flow sensors to this unit?

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      Sorry, it only connect a water flow sensor.

    • @WeitangChen110
      @WeitangChen110 Před 5 lety

      @@digitenvictor1532 do you have any device which can connect more than one sensors?

    • @digitenvictor1532
      @digitenvictor1532  Před 5 lety

      Please tell me the function, may be we will design new one in the future. but now we have not the one you want. sorry!@@WeitangChen110

  • @burkitbayevarman5435
    @burkitbayevarman5435 Před rokem

    What if in display, it is showing "ERR" instead of temperature. what is wrong?

    • @digitenvictor1532
      @digitenvictor1532  Před rokem

      Don't connect to temp sensor, or the temperature sensor is damaged

  • @LokiGro
    @LokiGro Před 4 lety

    how do I get my K value ? I have 4 and none are accurate. I've emailed support I've got zero support

    • @digitenvictor1532
      @digitenvictor1532  Před 4 lety

      Please tell me the model of flow sensor. in fact, you can ask for the manufacturer of flow sensor.

    • @LokiGro
      @LokiGro Před 4 lety

      DIGITEN Victor Digiten FL-408

    • @digitenvictor1532
      @digitenvictor1532  Před 4 lety

      @@LokiGro The K value is 7.5, you can adjust it according to the accuracy of discharge.

    • @LokiGro
      @LokiGro Před 4 lety

      DIGITEN Victor how Do I determine accuracy? If the water pressure changes will the k Value also need to be changed ? Thank your for responding I was loosing my mind

    • @digitenvictor1532
      @digitenvictor1532  Před 4 lety

      @@LokiGro If the water pressure changes, the accuracy will be changed, but the affect is small

  • @warunagayashan689
    @warunagayashan689 Před 6 měsíci

    is this suitable for 50ml per minutes?

    • @digitenvictor1532
      @digitenvictor1532  Před 6 měsíci

      Yes, it can monitor it. but the rate depend on the flow sensor.

  • @rinconmike
    @rinconmike Před 4 lety

    What is the difference between this and the one in this video: